Loading...
HomeMy WebLinkAbout2290-230 nRAvvNr- Ivo_ 224 o SHEF_T ` NO. 23 OF 23 O � _ V • _ GENERAL LEGEND U� SYMBOLS DESCRIPTIONS MANUFACTURER A -PART NO. REFERENCE - ' OUKyC VALVE < t\\ PAC. f2 PONT OF CONNECTION SPECIFICATION SET FLUSH WITH FINISH GRADE W LAWN AREA BOX TO BE PLACED SIDEWALK 3" ABOVE FINISH GRADE SIDEWALK CURS ••^• PRESSURE SUPPLY LINES & SIZE 2-12' & LGR P.V.C. CLASS 315 SPECIFICATION A. SIDEWALK,CURB, ETC. AT RIGHT ANGLE TO CURB, ETC- HARDSCAPE EDGE �- ' ' IN OTHER AREAS PRESSURE SUPPLY LINES & SIZE 2' & SML SCHEDULE 40 P.V.C. SPECIFICATION o a. m FINISH GRADE - .)j' •• - LAWN AREAS NON -PRESSURE LINES & SIZE P.V.C. CLASS 200 - SPECIFICATION rOR w N R � �,� 1L ° LOW VOLTAGE WIRE CONOIAT P.V.C. SCHEDULE 40 SPECIFICATION BOX TO BE PLACED AT RIGHT ANGLE TO 12 HARDSCAPE EDGE _ - :. 4 Vol 12"x IB" PLASTIC Bot a COVER w/ ° LOCK TOP '.' .� FINISH GRADE // t t « SHRUB AREAS 8 I CONTROLLER SEQUENCE GALLONS PER MINUTE • REMOTE CONTROL VANE SIZE 12"x 18"PLASTK: BOX AND COVER WITH -' :•'• CURL TYPE EXP#NSIO �• N - •� +*«+r / : + t t r t r LOCK 70P :. . • • • 0 ° °. .. LOOP( MIN. 24) --• -. •. ' + ?r++ +tom+ 12" ROUND PLASTIC AUTOMATIC CONTROLLERS EXISTING :° •� i * CURL TYPE EXPANSION LOOP (MIN. 24") = : � - •- °• � ' •A: • K"�' ' .. ' � ^ .. WATERPROOFED WIRE CONNECT •_ - : • �y - �j + . • • r * BOX 5 COVER .. , J t+ + +t r Q REMOTE CONTROL VALVES 2" S1`tiAL.LER GRISWOLD GP SERIES DETAIL NO. 1 ° « WATERPROOFED WIRE CONNECTION ,; „ C C � .... � � - .� '.: ; � - ; ; : ; : ;, : f � � - NON -PRESSURE CKRISTY S ID. TAG (STANDARD) •' - .� • STAINLESS STEEL CLAMP ,, / REMOTE CONTROL VALVES S1zi= y2- GRISWOLD 2000 SERIES DETAIL' NO. > • . - "` ` °";'` ' " CHRISTY S I.D. TAG ( STANDARD i f ` ` " .,Z- r �'� ` " NON -PRESSURE " � • •` • ` � ` ' _ SEGi1RE TO SOLENOID PIGTAIL " `��' LINE FITTING - , • • f., . ; • 0 QUICK COUPLING VALVES RAIN BIRD 33RC DETAIL NO.3 SECURE TO SOLENOID _ PIGTAIL ,• LINE dO 3 f �9 SIZE A LENGTH AS REO -D ® BACKFLOW PREVENTION ASSEMBLY FEBCO 825Y DETAIL NO.4 • FINISH GRADE �'� t FINISH GR LAWN A - - SCH. 80 PVC NIPPLE GATE VALVES -LINE SIZE HAMMOND 1B631 (3-b SMALLER) DETAIL NO.5 L1gAM AREA ' =- rt • 3 w �' EA GRAVEL HAMMOND IR1144 (4' 3 LARGER) DETAIL N0.6 PVC LME PIPE r. FINISH GRADE PVC LINE PIPE SHRUB AREAS � , •: • •'' S i� SCH. 40 PVCsii t! •; �. DOMESTIC PIPING SCHEDULE 40 BRASS SPECIFICATION i FINISH GRADE SHRUB AREA • .��, ,. SOLENOID ® , ELBOW �� ,' �,fr'�. •i,►_ ,. SCH. 40 PVC STREET ELBOW ® BOOSTER PUMP FREDERICK NO. FPEH-115S- 70F DETAIL NO.7 - ... •.: -': SOLENOID •• - - rT; - - .�:•. + ;.. 1' +�• •• -•. FLOW ADJUSMEI�fT ' -� ` , •.ti« '� • STRAINERS (GENERAL) WATTS 777 40 MESH DETAIL N0.4 a `� r �' : OW ADJUSTMENT 1� : SST' PEA GRA VEL IOP E 4 \:' SUPPLY PAS i DENOTES EXIST. REMOTE CONTROL VALVE �.'- •. � : .��. , • DENOTES EXIST QUICK COUPLER Q -PEA GRAVEL 5F ''y ( MIN. 3 CU. FT:) H. .. M PVC SC 4.. ALE ADAPTOR (TYP, 2 PLACES) LINE SIZE A LENGTH REO D FITTING .T'w DENOTES EXIST. BACKFLOW Y" 4 P� SCH � MALE �� - ' (TYP. 2 PLACES)PVC 11.0 �1 /J� LINE PIPE I d I S DENOTES EXIST. WATER METER T. -• PVC SUPPLY LINE DENOTES EXIST. SUPPLY LINE ~ a ,• : U -PVC LINEVC PELBOW PIPE ITTING(S x S x S) PVC SUPPLY UNE 2 ELECTRICAL PEDESTAL A CONTROLLER MYERS MEUG-1 -��0 8�a DETAIL A DIN LD•2 �S . PVCLINELINE PIPE COMMON WIRE 3g AUTOMATIC CONTROLLER W17H et4CLoSURE TORO 8000�NO. 132-56-08) DETAIL NO. 10 PVC SUPPLY LINEFITTNG(S:SxS) -COMMON WIRE CONTROL WIRE NOTEA _ _ _-- SLEt=VES FOR MAlk-41-wE P%VC. SCH.s}O SLF_EV)W DETAIL Kok LD- I �`�1 •„ �P CONTROL WIRE' [)VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE APPROVED. SCH. 40 PVC STREET ELBOW Gp L,A-TERALS CON?ROC h11RES NOTES:2)WHEN --/ MORE THAN ON VALVE IS LOCATED IN THE SAME AREA. PROVIDE A SPACE F. VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNOTHERWISE NOTED. LESS A MIN. 3 FT. APAR'd 2. WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAYE AREA. PROVIDE A SPAM A MN. OF 3)USE TEFLON TAPE ON ALL THREADED FITTINGS. NOTE: USE TEFLON TAPE (-W PVC PIPE STAxE ON ALL THREADED (SCH.40)cy � 3. USE TEFLON TAPE ON ALL THREADED FITTINGS- FITTING MIN. 36" LONG OR AS SITE w U $ . REQUIRES N :If uj co z _.. M Q �y 04 N gT 3 z a. _ -- r n .. TMP. REMOTE CONTROL VALVE ASSEMBLY (2-" sM.ALLEFZ) TYP. REMOTE CONTROL VALVE ASSEMBLY (2/z" S IZ>=� TYP. QUICK COUPLING VALVE ASSEMBLY 4c, �' q - • -FLANGED GNEVALVE BRASS NIPPLE) SPRINKLER HEAD LEGEND (TYP. 7REDUCED PRESSURE BRASS ELBOW SYMBO ARG RAO TRJ DESCRIPTION PSI GPM MFG. BODY NOZ. PCS REFERENCE • 3600 0' 0 FLOOD BUBBLER PIC 30 .25 TORO 570-S FB -25 -PC DETAIL NO.8 BACKFLOW PREVENTION/ BRA NIPPLE ROUND PLASTIC BOX • FLANGED GATE VALVE BRASSi UNION Ji AND COVER (COVER ■ 360' 0' 0 FLOOD BUBBLER P/C 30 .50 TORO 570-S FB -50 -PC DETAIL NO.8 F -� u BRASS PIPE �. - 1 MARKED: IRRIGATIONO GATE) m 0° T 5 5 FLAT LAWN HEAD 30 0.26 TORO 570C -6P -CV FSG -LA DETAIL NO.9 / ,/ I . • !"� 180• T 5 5° FLAT LAWN HEAD 30 0.50 TORO 570C -6P -0V FSH -LA DETAIL NO.9 o " $ • ROUND PLASTIC BOX sCOVER - • COVER MARKED: RRI GATE- FINISH GRADE LAWN AREAS Q) 90• 10' 5 LOW ANGLE LAWN HEAD 30 0.50 TORO 5700 -6P -CV 100 -LA .50 DETAIL NO.9 Z 0 M y % /RELIEF `x alew sic%c FINISH GRADE (�� 180° 10 15 LOW ANGLE LAWN HEAD 30 1.00 TORO 570C -6P -CV 1OH-LA 1.0 DETAIL NO. O >~ STRAINER /40 / PORT MESH MONEL • • • ' ✓r I 99 - x -" Ip " sc LAWN AREAS - x � � x � FINISH GRADE 360• 10' 15 LOW ANGLE LAWN HEAD 30 2.00 TORO 57OC-6P-CV 10F -LA 2.0 DETAIL NO.9 w �% / ' 15 �/ j / M(� CONC . R ASE -3250 - x as •. as �. FINISH GRADE " �" SHRUB � - SHRUB AREAS m ® 90° 1800 15' 15' 30 STANDARD LAWN HEAD 30 1.00 30 STANDARD LAWN HEAD 30 2.00 TORO 570C -6P -CV 150 1.0 DETAIL NO. TORO 570C 15H 2.0 DETAIL NO.9 ,.� y > p 't_ Z BRASS EL$4� / .� (5(.0-C - .' -6P -CV O BRASS NIPPLE � �:;.�� � 2 " OPERATING NUT W 3600 15' 30 STANDARD LAWN HEAD 30 4.00 TORO 5700 -6P -CV 15F 4.0 DETAIL NO.9 � Q a LOOSE KEY HOSE BIBS •'"�� �a 900 50 25 INTER. LAWN ROTOR HD 50 6.70 TORO 640 #40 DETAIL NO.9 �1 to O Q �''� U BALL VALVEt _-- / PLASTIC PIPE ERTEN - 180• 55 25 INTER LAWN ROTOR HD 50 10.20 TORO 640 #41 DETAIL N0.9 y N C '�, O BRASS NIPP •� I \ 1 HANDWHEEL 10 TION LENGTH AS REG D (MN. 6" I.D.)rr �' 90° 59 25 MED. LAWN ROTOR HD 50 12.90 -TORO 640 #42 DETAIL NO.9 H Q 0 U v ll ►r� •.• :C I • 180• 59 25 MED. LAWN ROTOR HD � 14.50 TORO 640 , #43 DE (AIL NO. _ V U II JJ BRASS E[90W / 3 PVC SUPPLY LINE 360• 59 1 25 MED. LAWN ROTOR HD 50 14.50 TORO 640 #43 DETAIL NO. `. 3 • �� r • •�/ UNC SIZE x 8 PVA SUPPLY -�--' - • _::: �h 90° 35 25 SMALL LAWN ROTOR HD. 35 1.43 TORO XP -300 #7 DETAIL NO.9 a c a SCH. 80 PVC TOE NIPPLE 6 P 1 - - > GATE VALVE �{p 1800 35' 25 SMALL LAWN ROTOR HD. 35 2.83 TORO XP -300 7 DETAIL NO. `+ [� In O o y PVC FEMALE ADAPTOR PEA GRAVEL = • v 360"' 35! 25 SMALL LAWN ROTOR HQ 35 5.70 TORO XP -300 #7 DETAIL N0.9 C-' OLL {� N Z TYP. THRUST BLOCK PRESSURE SUPPLY _ (MIN. CU. FT)�� VALVE END SHALL INE -DISCHARGE (SEE SPECIFICATION) ! + • : - GATE HALVE '^ •-:.:. • .� ' - ::;; , BBEE�INNG SSE��DD� HUB, . .• • .� FLANGED, ADAPTOR •• !!� NOTE:BACKFLOW ENCLOSURE -LE MEUR WIRE MESH I �RASS ELBOW 30% 12" 48" 8 HINGEP,A ,ONE END. SECURE ,fit DOMESTIC TO 6 zS-FOOTINGW/4, J BOLTS.(EOUIPMENT 18 °• PVC MALE W ADAPTORS • ••: _; . • ' • ;' . ' R . '�'.. , • • �• : / • PRESSURE TO BE CENTERED INSIDE HOUSING) E i • GRAVEL SUMP / /-NOMi -JSEE SPECIFICATION) ��i - 10 NOTE •.• ~i• .. j~ •• �• : •• (MIN. 3 CU. FL) NO"(� : �oR -THRUST P LOCK ASSEM$Li , -- 1) EOUIPMENT TO BE INSTALLED AT A MINIMUM OF 18' FROM WALLS,BLDG.,ETC. GATE VALVE SHALL BE INSTALLED N SHRUB AREAE • UNLESS OTHERWISE APPROVED. THRUST BLOCK WITH 2) WHEN UNIT IS NEXT TO BUILDING, WALLS. ETC.. TEST COCKS ARE TO BE ON OUTSIDE. • USE TEFLON TAPE ON ALL THREADED FITTINGS. REBAR STRIPS O 3 ALL UNDERGROUND PIPES SHALL BE DOUBLE WRAPPED WITH APPROVED TAPE WHEN USING GALVANIZED STEEL PIPE. NOTE: IF VALVE OCCURS IN PAVED AREA, BOX SHALL 8E CONCRETE WI7TH CAST-IRON COVER cJ.0 ui w 4) INSTALL THRUST BLOCKS ON UNITS 2 V21I AND, LARGE R. I ? 2 c� r _ . S) REPUCEP PRESSURE PRINCIPLE ASSEMBLY 70 BE THE SAME SIZE z AS METER. O 6) CONTACT CCWD, (70q)483-7440, MR. PETE PETERS, COW CERNINC-� � - U_ CC MATERIALS, LOCA?IONS ANIS 'TESTINCa REQUI(ZEMEIJTS - ` W o Z_ LL O Z O ami TYP. BACKFLOW PREVENTION ASSEMBLY - REDuCF-D TYP. GATE VALVE ASSEMBLY (3" & SMALLER) � TYP. GATE VALVE ASSEMBLY (4" & LARGER) w a E a PRESSURE PRINCIPLE PER CCW D STP. DWG- No. 2A • U U Lu - W 0 ^^ F� _• a / Q V =6' (D PUMP t MOTOR ASSEMBLY r----------------------------- S 16 ' ♦ 0 FLANGED BUTTERFLY VALVE (4!') IA - • .TA COLOR COOED MAP FOR VALVE - PEDESTAL P4=(ERS CUla • VANDAL R1CONTROLSIS ENCLOSURE A1ITDMATIC CONTROLLER UMT _- " t ► NO SLAM CHECK VALVE ( 4 ) SIDEWALK, CURB, .'�' ETC. LIGATION INSIDE (SEE SPECS) ISING ON CRETE SECU(FOCI 6 t! 14 i 6 i 7 11 ELBOW (REDUCING) ( ) O w 2 OR AS NOTED SIDEWALK CUtB FOOT WG WITH GAZV. J` BOLTS CFS 1 � 1 1 3 ' s TEE( 4") ' 0 ETC. BUBBLER HEAD � - • - SPRINKLER NOZZLE ° .. i i © ► _ i O NIPPLE (LENGTH AS REQUIRED) , ( INSTALL FLUSH WITH HARDSCAPE ' �,' • •, !•""1 I O7 ELBOW (LONG SWEEP) OR 2-45• ° �- - - • POP -LIP BODY ASSEMBLY D ALL t �R� SHALL BE TIED INSIDE O Z ' I ' e ELECTRICAL PANEL (NEMA 3) MOUNTED TO FRAME WITH to O LOCKABLE DOOR IN DOOR. DEADFRONT ENCLOSURE 2 1� S, 7 ..••' r i-• • INISH GRADE �• I (INSTALL I/2"ABOVE I FINISH GRADE) ON-OFF SWTTCH TO BE PROVIDED w cn BY CONTRAG-IDR (!F B�AMCE.R !S N O 13 4----------- -- ----------------- .� TED HEAR CONTROLLER LDU ) W � � W W 1/2' 'J' BOLT (4 PLACES) CALV. -MIN. SUCTION LINE BACKFLOW ( 4") CRETE FOOTING ( INSTALL 3 0 >41z U z H A�37VE GRADE AND SLOPE CONCRETE O • PtWP SINGLE ST SINGLE SUCTION BRONZE FITTED. UNiPUMP, CLOSED COUPLED it DISCHARGE TO S�►STEM (4 ) i + - � 1< H 1-4 U � TO A5MP., RP.M, 230 V_L_PHASE• 60 CYC. HORIZONTAL 12 FINISH GRADE 116 PVC SCH. 80 NIPPLE FINISH GRADE 6 Lu C) BALL BEARING„ DRIP PROOF MOTOR HAVING A CAPACITY OF C.P.M. a< TOTAL DYNAMIC MEAD OF 70 FT. t3 METAL ENCLOSURE (14 GAUGE). POWDER COATED (LENGTH AS REQUIRED) I i W CU C] H H E+ �O1 U • ALL FITTING TO BE OTHER SCH 40 CALV. SCREWED OR 125 lbs CLASS CAST O SECURE To FOOTING USING FLAT WASHERS SI NUT 4 PLACES) SIDES ( ), PVC SCH. 80 NIPPLE , ; ; FINISH GRADE < a < H H W `.i L) IRON FLANGED FITTING. ALL ABOVE GRADE MATERIAL SHALL BE CLEAN t PRIMED, TE AL EQ IP. AND (2) COATS OF RUSTOtiUM PAINT. SIZE 70 ACCOMMODATE ALL EQUIP. AS ILLUSTRATED. SIZE AS REQUIRED I , `• H w a U a H H � LLI 1t COMPANION FLANGE IF SCREWED FITTINGS ARE USED. PVC SCH. 40 STREET ELBOW • 6 `�� ELECTRICAL CONDUIT TO SOURCE O Gr [� U a 0 (INDEPENDENT SERVICE) Q C) 1 � C3' Q O CONCRETE FOOTING (6- THICK W/12 GAUGE WIRE MESH 6' SO-) • 8 u) W z 0 W a- PROVIDED BY CGI.ITRACTOFL . 1= H� 12 J OR /3 REPAR 12- O.C. AS REO'D 13 tc PROVIDE GALV. FITTING DOWN A THROUGH 90' ELBOW THEN LATERAL LINE PVC TEE PVC SCH. 40 ELBOW H a D LD W ELECTRICAL T (TAPE WiRlNG AT x z z a z H W . 1 _ I • PROVIDED ADAPTOR TO P.V.C.L FITTINGS SHALL BE SCH 40 SxSxT ( ) O TERVALi•OF 12 O.C.) H H • 0 O � c_==== 2 GALV.• WRAP 2 WRAPS OF PLASTIC TAPE. _ » c_- _ t 7 OR ELBOW 12 " PVC NIPPLE (SIZE AS " C LONG 3 z CG a >+ U � \ AS REO'D 17 4' SANG UNDER CONCRETE FOOTING • ., r;r ,: I REQUIRED) IN FINAL POSITION PVC TEE REQUIRED) RISER SHALL BE AT A SWEEP ELBOW 1 COMMON WIRE TO ALL R-GY S � W H 0 o ff H z w o 1 j r I to we -sal TO BE COMPACTED To 9sx COMPACTION. 1e' 22 1 12 6 S SxSxTOR • ELBOW 45 ANGLE G'40LINOING ROD (5/8": 8-O" COPPER 44U�>w I CONTROL WIRE TO EACH R.C.V.V� H � O ►-� a w E • 19 SEALTITE FLEX CONDUIT HOUSING ELECTRICAL WRING. CLAD) H W '� Z •--�- 20 GLYCERINE FILLED. 2 1/2- DIA. GAUGE WITH SHUT OFF COCK. I, IS 2t 9 0 w t' ADDITIONAL- COMMON WINE Ta ALL H � � ° a W _ I r O PUMP/PANEL SKID, SIZES AS REQUIRED. .........: i PVC SC1:.40 STREET PVC SCH. 40 STREET ELBOM NOTE:z W O W ►� COMMON WIRE TD BE WHITE AND CONTROL WIRE TO BE BLACK IN COLOR UNLESS O m U a o 22 ENCLOSURE MOUNTED TO FRAME IMP. 4 PLACES ( ) . . • t•: r : :::=:: 7 1j a 17 23 MOUNT PRESSURE SWATCH IN ELECTRICAL ENCLOSURE ELBOW �' OTHERWISE NOTED. as z H LY 1-1 z • NO SPUJCES SHALL BE MADE BETWEEN CONTROLLER AND REMOTE CONTROL 0 0 tn 0 Z U- 4 z W < z I\ AS REO'D. \61LVE UNLESS OTHERWISE APPROVED. W O z z rA SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. \\� ONDUUT To STUB-rueTI-IRouGI-{ CoNc• PAo USE TEFLON TAPE ON ALL THREADED FITTINGS LATERAL LINE (SIZE AS NOTED ON DRAWING) $ < M LL O W • CONTROL WIRING SEQUENCE CQ�€SPONDS TO OPERATING SEQUENCE OF REMOTE z A � <n H W � az wHcnx CONTROL VALVES AND AUTOMATIC CONTROLLER UNIT. (AS ON DRAWING)O) W � goTToM OF PANEL_ NOTE ELECT. PROVIDED BY CONTRACTOR O 0 < 0 % U rZ' E' H > E-1 �Y\ P.O.C. TO EXIST. EL ECT. PED. -MINIMUM ELECT. NOTE : USE TEFLON TAPE ON ALL THREADED FITTINGS • WHEN USING RAIN GUARD LOCATE CONTROLLER IN A WAY NOT TO BE L- j SERVICE REQUIRED 23W.,60AMP,SINGLE PHASE. SPRAYED BY SPRINKLER aHarxow� -Icwr� N ' CONTRACTOR TO VERIFY PRIOR TO INSTALLATION AND NOTrIFY OWNER IF MINIMUM REQUIREMENTS UWxOZC]�� � W J ARE NOT EXIST. Qw', E-4 0 a4i ►--1 0 Z E-4 0 Z d O � Q RECORD - DRAWING TYP. BOOSTER PUMP ASSEMBLY TYP. BUBBLER HEAD ASSEMBLY TYP. SPRAY HEAD ASSEMBLY TYP. AUTOMATIC CONTROLLER ASSEMBLY .. .. 19 o 0 nRAvvNr- Ivo_ 224 o SHEF_T ` NO. 23 OF 23