HomeMy WebLinkAbout3956-30E 0 U) ry W z w ol 3m CD W 00 r SYMBOL MANUFACTURER MODEL # DESCRIPTION GALLONS PER MINUTE VAN F TQ TT H T Q RAD. '6 RAINBIRD 1806 -SAM -PRS -15 6" POP-UP- LAWN SPRAY W/ CHECK VALVE 0 80 3 70 PSI DETAIL, REF. - 1.85 1.23 0.92 15' 30 STD. PLAN NO. 523 FOR LAWN 1812 -SAM -PRS -15 12" POP-UP SHRUB SPRAY W CHECK VALVE 0.80 3.70 - - / 1.85 1.23 0.92 15' STD. PLAN NO. 524 - DETAIL #7 SHEET 35 +V V RAINBIRD 1806 -SAM -PRS -12 6" POP-UP- LAWN SPRAY W/ CHECK VALVE - 2.60 - - 1.30 0.87 - 12' 30 1812 -SAM -PRS -12 12" POP-UP SHRUB SPRAY W/ CHECK VALVE - 2.60 - - 1.30 0.87 - 12' RAINBIRD 1806 -SAM -PRS -10 6" POP-UP- LAWN SPRAY W/ CHECK VALVE - 1.58 - - 0.79 0.52 0.39 10' 30 1812 -SAM -PRS -10 12" POP-UP SHRUB SPRAY W/ CHECK VALVE - 1.58 - - 0.79 0.52 0.39 10' V ® RAINBIRD 1806 -SAM -PRS -5 6" POP-UP- LAWN SPRAY W/ CHECK VALVE - - - _0 _ .20 0.10 5' 30 1812 -SAM -PRS -5 12" POP-UP SHRUB SPRAY W/ CHECK VALVE - - - - 0.20 - 0.10 5' ID RAINBIRD 1806 -SAM -PRS- 1 5SST 6" POP-UP- LAWN SPRAY W/ CHECK VALVE - - - - 1.21 - - 415 30 1812-SAM-PRS-15SST 12" POP-UP SHRUB SPRAY W/ CHECK VALVE - - - - 1.21 - - 405 ® RAINBIRD 1806 -SAM -PRS- 1 5EST 6" POP-UP- LAWN SPRAY W/ CHECK VALVE - - - - - - 0.61 415 30 1812-SAM-PRS-15EST 12" POP-UP SHRUB SPRAY W/ CHECK VALVE _ _ _ - _ - 0.61 415 RAINBIRD 1402 FULL CIRCLE TRICKLE PATTERN BUBBLER 0.50 1' TO 3' 30 DETAIL #2, SHEET 35 (FROM TREE TRUNK, 2 BUBBER HEADS PER TREE) A HUNTER I -20 -ADS -3.0 ADJUSTABLE POP-UP ROTOR 2.40 W/ CHECK VALVE 28' 40 DETAIL #3, SHEET 35 A HUNTER 1-20-36S-3.0 FULL POP-UP ROTOR 2.40 28' 40 W/ CHECK VALVE HUNTER 1 -20 -ADS -6.0 ADJUSTABLE POP-UP ROTOR 4.90 37, 40 W/ CHECK VALVE 8 HUNTER 1-20-36S-6.0 FULL POP-UP ROTOR 4.90 37' 40 W/ CHECK VALVE S T TORO SENTINEL AUTOMATIC CONTROLLER 24 STATION EACH, TORO SENTINEL CONTROLLER INSTALL IN PEDESTAL STAINLESS SEE CIVIL DETAIL SHEET C-805 ESB24-U2-MPEA161 OK- STEEL METER ENCLOSURE MODEL NO, MPEA161-QB1-VRA. BACKBOARD, LEVEL 1 SURGE PROTECTION AND VRA 000 OBI-VRA1-VRA ANTENNA. 120 VOLT POWER SUPPLY NIBCO T-113 LINE -SIZED GATE VALVE STD. PLAN N0. 519 -DETAIL #1 SHEET 36 RAINBIRD GB SERIES BRASS ELECTRIC REMOTE CONTROL VALVE - SIZES NOTED. STD, PLAN NO. 511 - DETAIL #4 SHEET 35 ALL VALVE BOX COVER IS BOLTED BOWN RAINBIRD 33DLRC 3/4" QUICK COUPLING VALVE, WITH RUBBER -LIKE VINYL COVER LOCK. P.V.C. CLASS 315 SOLVENT WELD TYPE FOR 2" OR LARGER MAIN LINE & SCHEDULE 40 P.V.C. FOR MAIN LINE SMALLER THAN 2" - SIZES NOTED SCHEDULE 40 P.V.C. LATERAL LINE - SIZES NOTED 1y" SCHEDULE 40 P.V.C. PIPE SLEEVE - 2X DIA. SIZE OF ENCLOSED PIPES) SCHEDULE 40 P.C.V. WIRE SLEEVE - 2X DIA. OF WIRES TO BE SLEEVED (3/4" DIA. MIN. SIZED SLEEVE) CONTROL VALVE INFORMATION - STATION NUMBER GALLONS PER MINUTE VALVE SIZE WATER STATIC PRESSURE AVAILABLE FOR IRRIGATION = 65-70 P.S.I. PER OF CITY OF FOUNTANA IRRIGATION POINT OF CONNECTION (P.O.C.) SEE IRRIGATION PLAN PER LOCATION. Y1 ) C_.)C_.)Signature 12/31/2010 J e newal Date ate �Q OF CN A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV PIPE SIZING CHART (LATERAL LINE° ONLY) GPM PIPE SIZE 0 - 10 /4': 10 - 16 1" 16 - 26 1y" 26 - 36 1Y" 36 - 50 2" REVISION DESCRIPTION DATE I ENGR. I CITY I DATE STD. PLAN NO. 521 DETAIL #5 SHEET 35 STD. PLAN. NO. 515, 516, 518, & 520 SEE DETAILS, SHEET 36 STD. PLAN. NO. 515, 516, & 518- DETAIL #5, #3,#2 SHEET 36 STD. PLAN. NO. 515, 516, 518 & 520- DETAIL #5, #3,#2, #4 SHEET 36 STD. PLAN NO. 516 - DETAIL #2 SHEET 36 1) DO NOT WILLFULLY INSTALL THE SYSTEM AS DESIGNED WHEN IT IS OBVIOUS THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT WERE NOT KNOW DURING DESIGN. SUCH CONDITIONS SHALL BE BROUGHT UP TO THE ATTENTION OF THE ENGINEER BEFORE WORK IS INSTALLED; OTHERWISE THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY REQUIRED REVISIONS. 2) ALL WIRES FROM THE CONTROLLER TO THE AUTOMATIC VALVES TO BE COPPER, DIRECT BURIAL, MINIMUM #14 GAUGE. INSTALL IN THE SAME TRENCH AS THE MAIN LINE WHERE POSSIBLE. MINIMUM COVERAGE OVER WIRE TO BE 18". COMMON WIRE TO BE WHITE IN COLOR. CONTROL WIRES TO BE A DIFFERENT COLOR FOR EACH CONTROLLER USED. BUNDLE AND TAKE WIRES AT A MINIMUM OF 20 FEET ON CENTER. 3) FINAL LOCATIONS FOR BACKFLOW PREVENTERS AND CONTROLLERS TO BE DETERMINED BY ENGINEER IN THE FIELD BEFORE INSTALLATION. INSTALL ALL EQUIPMENT PER CITY OF FONTANA LIST OF DETAILS REFERENCED TO FONTANAN STANDARD PLANS. 4) PROVIDE A MINIMUM COVERAGE OF 18" FOR PRESSURE LINES AND 12" FOR NON -PRESSURE LATERALS. PROVIDE SCHEDULE 40 SLEEVE AND 24" COVER FOR ALL LINES UNDER PAVING. PIPE SHALL NOT HAVE ANY JOINTS WITHIN SLEEVE. 5) ALL HEADS ADJACENT TO PARKING LOTS OR ALONG ROADS OR WALKS SHALL BE INSTALLED IN HIGH POP-UP BODIES. 6) POP-UP TYPE SPRINKLER HEADS INSTALLED IN SHRUB OR GROUND COVER AREAS SHALL BE INSTALLED SO THAT THE TOP OF THE SPRINKLER HEAD IS 1" ABOVE FINISHED GRADE. 7) THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE MAXIMUM FLOW DEMAND SHOWN ON THE IRRIGATION DRAWINGS AT EACH POINT OF CONNECTION. THE IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. 8) THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS IS FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHERE POSSIBLE. AVOID ANY CONFLICTS BETWEEN THE SPRINKLER SYSTEM, PLANTING AND ARCHITECTURAL FEATURES. 9) THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS, ROADWAYS AND/OR BUILDINGS. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM OPERATING PRESSURE FOR EACH SYSTEM. 10) IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FAMILIARIZE HIMSELF WITH LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS WORK WITH THE GENERAL CONTRACTOR AND OTHER SUB -CONTRACTORS FOR THE LOCATION AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING STRUCTURES, ETC. IN ADDITION TO THE CONTROL WIRE SLEEVES SHOWN ON THE DRAWINGS. 1 1) THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE SLEEVES OF SUFFICIENT SIZE UNDER PAVED AREAS. WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, TREES, LIGHTS, ETC.) INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT PROPER COVERAGE, THE IRRIGATION CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE, HALF CIRCLE OR ADJUSTABLE CIRCLE SPRINKLER HEAD ON EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL ADJUSTMENTS SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. AECOM 1131 W. SIXTH STREET, SUITE 350, ONTARIO, CA. 91762 PHONE: (909) 933-5225 FAX: (909) 933-5228 Prepared Under The Supervision Of ALI Date : CITY OF a CALIFORNIA PACIFIC ELECTRIC INLAND EMPIRE TRAIL IMPROVEMENT DRAWN BY: J.K. SEGMENT 6 SCALE: DESIGNED BY: -- IRRIGATION DATE: G.O. 3/30/09 CHECKED BY: APPIROVED Y: DRAWING NO.: 730 L.C. 3956 C ENGINEER R.C.E. 51152 DATE:57