HomeMy WebLinkAbout3958-19Ul
co
0
cn
CO STRUCTS NOTES
SANDBLAST CONFLICTING
wit
EXISTING STRIPING AND/OR APPLY e -WIDE YELLOW CENTERLINE STRIPING PER
ON SHEET 26,
PAVEMENT MARKINGS SOUTH DETAIL "C'
AND NORTH OF TRAIL
INSTALL SIGN(S) AS SHOWN.
INSTALL 175W MH -240V ERA BELL ®E17 -H2 -HS
ITH FLAT LENS, HAI 2S ARM,
FIXTURE W
L
-4120/LG-P/HF2/DR-GFI NON-TAPERED
±300' FROM EDGE OF TRAJ,� KRSI 6
ROUND STEEL POLE AND FOUNDATION
BY KIM LIGHTING OR APPROVED APN 192",-112EQUAL.
-W
% _4
REFER TO DETAIL ON SHEET 25.
IGROUN
. D 11
45
AIL -L-,
#5 P19 (T) PANEL Ir
PuAILA6-AD RIGHT-OF-VAVAY INSTALL NO. 3-1/2(T) PULL BOX PER CALTRANS
4
STD. PLAN ES®8 (UNLESS OTHERWISE NOTED),
A
RI -1
WAl 1-2 2 W3-11
W16-7 ) C 26 CONSTRUCT CONCRETE PAD PER DETAIL
+
0Er ON SHEET 26.
PACIFIC ELECTRIC RAILWAY R/W
PACIFIC ELECTRIC
•
SERVED
MIT LINE
+
45' RE CD INSTALL 1-1/27- PVC SCH. 40 WITH 5®8 WIRES,
LI
T 2-#8 FOR EACH CIRCUIT, PLUS 1-#8 GROUND PER
CD
WIRING DIAGRAM ON SHEET 26.
LL
155
LU
T1,
-#8 WIRES,
14- -1 PVC SCH. 40 WITH 3
7B INSTALL I
.. .... 287'�
V . . . . . . . . . .
. . . . . . . . . . . LU
. . . . . . . . . .. . . . . . . . . PER WIRING DIAGRAM ON SHEET 26.
. . . . . . . . . . . . . . . . . . . . . .
... ... . LL'O(g CONSTRUCT 5- PVC SCH, 40 PER SCE
..... .......
. . . . . . . . . . . . . . . ... ... Z
low
Lu. REQUIREMENTS. SCE IS TO SUPPLY SERVICE
4UUIUSE TRAIL
R 44A (CA)
WIRES TO NEW SERVICE ENCLOSURE TO MAKE
AN OPERABLE SYSTEM.
4—
U
_77
21-07
+
X 21 _71 R N 192
00 INSTALL CONDUIT SWEEP AND END CONDUIT AT
3—
F 7
<
THE BASE OF EXISTING POLE APPROXIMATELY
V 11 -2 J, ME
CrrY OF-FONTANA
GROUND. SCE IS TO INSTALL RISER AND
16-7 ADD ABOVE
V� P(L RIV4 SANDBLAST CONFLICTING GR 0 V ND J SERVICE WIRING.
I 1_� I DE.NSE
CITY OF FONTAT bR
EST, 0 P# 176460t EXISTING STRIPING AND/
T, SO
R/tY I I y . I -it
, 1 1 4 1 1 AVEMEN _MARK[NGS-,.,, U H I l __. ._� ,, ,,, f � 1. ( 35 INSTALL PAVEMENT MAPVIkM(lRN AS IRWOWN,
AND N0 RTH OF TRAIL GE -Nr L PER CALTRANS STD. PLAN A24C AND A24D.
A ERA , NOTES (APPLICABLE TO SHEETS 19 THROUGH 27)
WHITE, THERMOPLASTIC
FM EDGE OTRAIL I ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN
�6F
Q6)
SHALL CONFORM TO THESE PLANS, CALIFORNIA BARRICADES, DELINEATORS, OR OTHER TRAFFIC CONTROL AT ALL TIMES. INSTALL 15 FT -LONG, 2e CONTINENTAL BAR X -WALK
MUTCD 2006, CITY OF FONTAWS STANDARD SPECIFICATIONS, AND PATTERN AS SHOWN (WHITE,THERMOPLASTIC).
CALTRANS STANDARD SPECIFICATIONS 2006. 7. CONTROL POINTS OR "CAT -TRACKING!' SHALL BE APPROVED BY THE
>
ENGINEER, 2(TWO) WORKING DAYS PRIOR TO PAVEMENT STRIPING 3 INSTALL 12" WIDE SOLID LIMIT LINE 5 FEET BEHIND
2. PAVEMENT MARKINGS SHALL CONFORM TO THE CITY OF FONTANA STANDARD APPLICATION. EDGE OF X -WALK BAR. (WHITE, THERMOPLASTIC)
0
STENCILS AND SHALL BE ALKYD THERMOPLASTIC PER SPECIAL PROVISIONS.
04
0, ALL CONFLICTING STRIPING, MARKINGS SHALL BE REMOVED BY METHOD FURNISH AND CONSTUCT 22,000 LUMENS, MARBELITE
3, TRAFFIC SIGNS SHALL BE CONVENTIONAL UNLESS OTHER -WISE SHOWN ON THE
AS APPROVED BY THE CITYS TRAFFIC ENGINEER. STREET LIGHT POLE OR APPROVED EQUAL, PER
ULI WI
PLANS
CITY OF FONTANA STD. PLAN NO. 1016. COORDINATE
.
9. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT WITH SOUTHERN CALIFORNIA EDISON (SCE).
<
4. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POST, UNLESS
- (800)227-2600 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION. -U2-MPEAI 61 OK-OB1 -VRA
[ _ OTHERWISE SHOWN, PER CITY OF FONT
ANA'S STANDARD DETAIL NO. 139.
THE CONTRACTOR ACCEPTS ALL RESPONSIBILITY FOR ANY AND ALL FURNISH AND INSTALL ESB12
5. CONTRACTOR SHALL COORDINATE AND CONTACT SCE REPRESENTATIVE (909) DAMAGES TO EXISTING UTILITIES. ELEC./00046I SERVICE ENCLOSURE (METERED).
357-6221 PRIOR TO MAKING ANY ELECTRICAL SERVICE POINT CONNECTION. PER SPECIFICATIONS AND DETAIL `E` ON SHEET 27.
."Ic REFER TO INDIVIDUAL PANEL SCHEDULES, AND
ELECTRICAL DIAGRAMS ON SHEET 27 FOR DETAILS.
I f. j
T.
INSTALL 3-#8 SERVICE WIRES TO IRRIGATION
RAILROAD RIGHT-OFT -WAY
R AN -- ---- -- CONTROLLER. CONSTRUCT FOUNDATION COMPLETE.
45' RESERVED
PACIFIC ELECTRIC RAILWAY Rn/.W 0
CCDD SYMBOLS LEG END
+ LIMIT,11]
+
LO
0 (APPLICABLE TO SHEETS 19 THROUGH 2
®
7)
5
c'm
J__
SINGLE PGS SIGN
............. . ...... -------
..........
.......... w
COZ ......... ....... -.�% .. - --11 — 1. 1 1 1.1'.,. 1 L .......... ..
...........
... . ......... ,
........... ............
P-0
9 .......
". 71 LU a)
.......... :1,�,i,.,.",.*.''*-".,.,.,.,Z".,.��"..,.,.,�"", ';'L'. "'.' . j� , ,.'
. . ........
............
Q IN—PAVEMENT WARNING LIGHT
Du........ ... ...
..........
+ . . . . . . . . . . . . . . . .
Eta&
lul ELECTRICAL PULLBOX
_J . . . . . . . .. . . . . . . . ... . . . . . cn
. . . . . . . . . . .
(SIZE PER PLAN CON NOTE)
MULTIUSE TRAIL
ELECTROLIER (LIGHTING STD.)
<
22,000 LUMENS, STREET LIGHT POLE
7
A' 16 -49
21
S-1-- ,
16 A k,-
20, 10, 0 200
SCAU IVI FEET
. .. ........
DIAL
BEFORE
YOU DI
91- �_#2- 7m
..........
REVISION DESCRIPTION DATE ENGR. CITY DATE BASIS OF BEARING
THE CALIFORNIA COORDINATE SYSTEM OF 1983 (CCS -83), ZONE 5, EPOCH 1992.88, BETWEEN SAN
BERNARDINO COUNTY SURVEYOR'S GPS STATIONS 21120 AND 21289, BEING GRID AZIMUTH OF 103,45'25.
GRID VALUES WERE HELD FOR ALL POINTS, HOLDING SAN BERNARDINO COUNTY GPS POINT 21126 AS THE
POINT OF ORIGIN. ALL POINTS WERE THEN ROTATED TO HOLD THE GRID AZIMUTH BASIS
BENCHMARK
NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD-29) BASED ON SAN BERNARDINO
COUNTY GPS POINT 21129 FOR VERTICAL CONTROL, ELEVATION = 1319.336 AND
VERIFIED TO MATCH SAN BERNARDINO COUNTY BENCHMARK 470 (ELEV. 1275.152) PER
MY OF FONTANA CIVIC CENTER PARK — PHASE 1.
AECOM UTY OF FONTRM
ANA, CAUFOA
PACIFIC ELECTRIC INLAND EMPIRE TRAIL IMPROVEMENT
1131 W. SIXTH STRM, SUITE 3W, OWARIO, CA. 91762
PHONE: (909) 933-5225 FAX. (909) 933-5228 DRAWN BY: SCALE:
1 20'
No. 64286 rn LF Prepared Under The Supervision Of - , SIGNING, STRIPING AND j
Exp. 6/30/09 DESIGNED BY: ---- / / L I GHT I NGIP�m 03/30/09 LL F L / , DATE:
/
CHECKED M APP D c DRAWING NO.:
AlL Date
AITIEF NAFTALI LT tITy ENGINEER __lfCE 51152 3956 737