Loading...
HomeMy WebLinkAbout3955-18v .J t:i a C:><( v � I -2 LD CL cry �a Iv E i Mo W U� �w 5 N E LR �a c v aQ �CN 0 co UJ I— ®a Lift hole Hold-down DOItIlz Pull box reinforced with galvanized Z -bar welded frame --. Reinforced 12 mm Min steel plate cover, galvanized after fabrication, See Note 4. - Galvanized Z -bar welded frame Pull box Bonding jumper, 4• r: See No 5 +PCC Jf •o', rte_ -------x--, —r b LI i T I ___-.--'_._J. TOP VIEW 13 mm length Top flush lsleeve nut (( with with brass I finished 1 bolt j 9rode i ns DIMENSION TABLE .CONCRETE BOX NON -PCC BOX CONCRETE OR NON -PCC COVERS BULL '80X. Minimum * Minimum Depth Box WO LO. M(nimum ** Minimum Depth Box L ** W ** R' Edge Edge _Thickness and Extension (mm) (mm) Thickness and Extension (mm) (mm) ;(mm) Thickness Tape No. 3 25 mm I No Extension 1 260 1 510 1 8 mm No Isio 1 390 1 260 1 30 1 45 mm 1 3 mn No. 5 25 mm 560 mm 460 710 _ 8 M_.- _ _510 mm _ J.590_ _ 350 32 _ 5p mm_ 3 mfl No. 6.... 40 mm 600 mm 580 910 10 mm 510 mm 780 450- 32 50 mm 1 3 mo * Excluafng conduit web ** top dimension SYa:+ N CVIfr.NN9 JI R6. x::Ci.'.'. M arls aivi: rw! le resY.v:ei>:Pb lw �Ir. ae'.a.^ 7, gaf M ;1w ralf ans ivpli s'.> po V' * Excluding conduit web ** Top dimension 150 Min of l around \ e - 80 Min f\, Clean crushed . of I around I •e /-Grounding rock sump Orcin hole'�/-Grounding bushing NOTES ON PULL BOXES SECTION A- A 1. Traffic pull box shall be provided with steel cover and special concrete 9)"TOS POWER" TOS power. footing. Steel cover Shall have embossed non-skid pattern. No. 3(/2(T)' NO. 5(T) AND tG) "TDC POWER" telephone demarcation cabinet power. 2. Steel reinforcing shall be as regularly used in the standard products of No. 6(T) TRAFFIC PULL BOX the respective manufacturer. 11) "CCTV" Closed circuit television circuits. 3. Top of pull boxes shall be flush with surrounding grade or top of adjacent 12) "TMS" Traffic monitoring station circuits. LO curb, except that in unpaved areas where pull box is not immediately adjacent to and protected by aconcrete foundation, pole or other 13) "CMS" Changeable message sign circuits. t protective construction, the box shall ploewith Its t3mm above t' surrounding grade. Where practicable, pull boxxess shown in the vicinity of 74) "NAR" Highway advisory radio circuits. R— See Note 2 - curbs shall be placed adjacent to the back of curb, and pull boxes shown adjacent to standards shall be placed on side of foundation facing away 5. Bonding jumper for metal covers shall be 1 In long, minimum. from traffic, unless otherwise noted. When pull box is installed In �P = ? sidewalk area, the depth of the pull box shall be adjusted so that the 6" The nominal dimensions of the opening in which the cover sets shall be II +I top of the pull box is flush with the sidewalk. the some as the cover dimensions except the length and width p dimensions shop be 3 mm greater. s u "•P �� ;/ s 4. Pull box covers shall be marked as follows: "SERVICE" Service circuits u�o \ between service point and service disconnect; "SPRINKLER -CONTROL" 7. Covers and boxes shall De interchangeable with California standard mole Sprinkler cOntr01 Circuits, 50 V or less;'CALTRANS" On at pull boxes, and female gages. When interchanged with o standard mole or female except pull boxes marked SPRINKLER -CONTROL"; and TELEPHONE" .gage, the top surfaces sFtall be flush within 3 mm.. Top outside edge of 70 mm p brass - - - Telephone service. concrete covers and pull boxes shall have a 6 mm minimum radius. or stainless steel `— Letters to be 25 Min I stud bolts, nuts Le to Max high. a) No. 3V2 pull box. S. Pull box shall not be installed within the boundaries of new or existing and washers. Lift holes curb romps. See Note 4. 2 per box, Recess � i) "SIGNAL" Traffic signal circuits with or without street or sign in cover with nut. -1' lighting circuits. 9. Pull boxes for electroliers, post and signal standards shall be located TOP VIEW ± 1.5 in from the station of the adjacent electrolier, post or signal Bonding jumper 2) "ST LIGHTING" Street or sign lighting circuits where voltage standard. Pull boxes shall be placed adjacent to bock of curb or is under 600 V. edge Grounding bushing of shoulder except where this is Impractical, a box may be 20 Max Lipp I Grade (See Note 3) N 5 6 9 r9A If 72 Min ,/r placed in another suitable protected and accessible location. b) CL rr - a o. , , o pu ox. DIMENSION TABLE Grout or sign lighting circuits. CONCRETE BOX Secure ponding jumper 2) "STREET LIGHTING" Street or sign fighting circuits where to grounding bushings NON -PCC BOX CONCRETE OR NON -PCC COVERS PULL BOX Minimum * Minimum Depth Boxf WO LO W1 L7 Minimum ** Minimum Depth Box L ** W ** R Edge Edgl Thickness 1 and Extension `(mm) mm) (mm) (mm) Thickness and Extension (mm) (mm) (mm) Thickness Tape lo. 3' (T) 40 mm 300 mm 430 ± 25 530 ± 370 ± 270 ± 25 Does Not Apply 510 No. 5(T) No 6(T) 45 mm 50 mm 300 mm 1 300 mm 1760 a ± 25 750 ± 1480 t 1330 ± 25 * 25 900 ± 1600 f 1430 * 25 1 Does Not Apply 1 Does Not A 1 690 ± 410 ± 840 * 510 t 0 t3 mm Non1 0 13 mm Nonu V' * Excluding conduit web ** Top dimension 150 Min of l around \ e - 80 Min f\, Clean crushed . of I around I •e /-Grounding rock sump Orcin hole'�/-Grounding bushing NOTES ON PULL BOXES SECTION A- A 1. Traffic pull box shall be provided with steel cover and special concrete 9)"TOS POWER" TOS power. footing. Steel cover Shall have embossed non-skid pattern. No. 3(/2(T)' NO. 5(T) AND tG) "TDC POWER" telephone demarcation cabinet power. 2. Steel reinforcing shall be as regularly used in the standard products of No. 6(T) TRAFFIC PULL BOX the respective manufacturer. 11) "CCTV" Closed circuit television circuits. 3. Top of pull boxes shall be flush with surrounding grade or top of adjacent 12) "TMS" Traffic monitoring station circuits. LO curb, except that in unpaved areas where pull box is not immediately adjacent to and protected by aconcrete foundation, pole or other 13) "CMS" Changeable message sign circuits. t protective construction, the box shall ploewith Its t3mm above t' surrounding grade. Where practicable, pull boxxess shown in the vicinity of 74) "NAR" Highway advisory radio circuits. R— See Note 2 - curbs shall be placed adjacent to the back of curb, and pull boxes shown adjacent to standards shall be placed on side of foundation facing away 5. Bonding jumper for metal covers shall be 1 In long, minimum. from traffic, unless otherwise noted. When pull box is installed In �P = ? sidewalk area, the depth of the pull box shall be adjusted so that the 6" The nominal dimensions of the opening in which the cover sets shall be II +I top of the pull box is flush with the sidewalk. the some as the cover dimensions except the length and width p dimensions shop be 3 mm greater. s u "•P �� ;/ s 4. Pull box covers shall be marked as follows: "SERVICE" Service circuits u�o \ between service point and service disconnect; "SPRINKLER -CONTROL" 7. Covers and boxes shall De interchangeable with California standard mole Sprinkler cOntr01 Circuits, 50 V or less;'CALTRANS" On at pull boxes, and female gages. When interchanged with o standard mole or female except pull boxes marked SPRINKLER -CONTROL"; and TELEPHONE" .gage, the top surfaces sFtall be flush within 3 mm.. Top outside edge of 70 mm p brass - - - Telephone service. concrete covers and pull boxes shall have a 6 mm minimum radius. or stainless steel `— Letters to be 25 Min I stud bolts, nuts Le to Max high. a) No. 3V2 pull box. S. Pull box shall not be installed within the boundaries of new or existing and washers. Lift holes curb romps. See Note 4. 2 per box, Recess � i) "SIGNAL" Traffic signal circuits with or without street or sign in cover with nut. -1' lighting circuits. 9. Pull boxes for electroliers, post and signal standards shall be located TOP VIEW ± 1.5 in from the station of the adjacent electrolier, post or signal Bonding jumper 2) "ST LIGHTING" Street or sign lighting circuits where voltage standard. Pull boxes shall be placed adjacent to bock of curb or is under 600 V. edge Grounding bushing of shoulder except where this is Impractical, a box may be 20 Max Lipp I Grade (See Note 3) N 5 6 9 r9A If 72 Min ,/r placed in another suitable protected and accessible location. b) CL rr - a 1 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV REVISION DESCRIPTION DATE I ENGR. I CITY I DATE u�..u��� uwci sR u� lul HE CALIFORNIA COORDINATE SYSTEM OF 1983 (CCS -83), ZONE 5, EPOCH 1992.88, BETWEEN AN BERNARDINO COUNTY SURVEYOR'S GPS STATIONS 21128 AND 21289, BEING GRID AZIMUTH OF 03'45'29ID. GRID VALUES WERE HELD FOR ALL POINTS, HOLDING SAN BERNARDING COUNTY GPS DINT 21128 AS THE POINT OF ORIGIN. ALL POINTS WERE THEN ROTATED TO HOLD THE GRID AZIMUTH BASIS. ONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD-29) BASED ON SAN BERNARDINO NTY GPS POINT 21129 FOR VERTICAL CONTROL, ELEVATION = 1319.336 AND FLED TO MATCH SAN BERNARDINO COUNTY BENCHMARK 478 (ELEV. 1275.152) PER OF FONTANA CIVIC CENTER PARK - PHASE 1. pF ESS % A No. 64286 M rn Exp. 6/30/09 \�9r„ CIV 1131 W. SIXTH STREET, SUITE 350, ONTARIO, CA. 91762 PHONE: (909) 933-5225 FAX: (909) 933-5228 Prepared Under The Supervision Of : EF NAFTALI n n Date " NO SCALE 4 , �.._._........ MIT ST SCALE ` 1' 1 D PLAN PER I DESIGNED BY: DATE: 3/30/09 .C�4 DRAWING w. _011 f J i ,� • r 51152 Dv o. , , o pu ox. See Note 2 t) "TRAFFIC SIGNAL" Traffic signal circuits with or without street Grout or sign lighting circuits. Secure ponding jumper 2) "STREET LIGHTING" Street or sign fighting circuits where to grounding bushings i . voltage is under 600 V. �.�• 3) "STREET LIGHTING -HIGH VOLTAGE" Street or sign lighting Extension - _ Seal around conduit circuits where voltage is above 600 V. with mortar RE +- � • - �•- Extension when box houses 4) "IRRIGATION" Circuits to irrigation controller 120 V or more. STATE OF CALIFORNIA transformer, ballast, or DEPARTMENT OF TRANSPORTATION when specified 5)"RAMP METER" Romp meter circuits. _ /� `Clean crushed rock sump ,ELECTRICAL SYSTEMS Ground i _ 6) "COUNT STATION" Count or speed monitor circuits. clamp —-=.f_ Grounding electrode when specified or (PULL B O X DETAILS) "COMMUNICATION" Drain hole-' when box houses transformer 7) Communication circuits. SECTION B -B - 8) "TOS COMMUNICATIONS" TOS communications line NO SCALE INSTALLATION DETAILS ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE SHOWN 1 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV REVISION DESCRIPTION DATE I ENGR. I CITY I DATE u�..u��� uwci sR u� lul HE CALIFORNIA COORDINATE SYSTEM OF 1983 (CCS -83), ZONE 5, EPOCH 1992.88, BETWEEN AN BERNARDINO COUNTY SURVEYOR'S GPS STATIONS 21128 AND 21289, BEING GRID AZIMUTH OF 03'45'29ID. GRID VALUES WERE HELD FOR ALL POINTS, HOLDING SAN BERNARDING COUNTY GPS DINT 21128 AS THE POINT OF ORIGIN. ALL POINTS WERE THEN ROTATED TO HOLD THE GRID AZIMUTH BASIS. ONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD-29) BASED ON SAN BERNARDINO NTY GPS POINT 21129 FOR VERTICAL CONTROL, ELEVATION = 1319.336 AND FLED TO MATCH SAN BERNARDINO COUNTY BENCHMARK 478 (ELEV. 1275.152) PER OF FONTANA CIVIC CENTER PARK - PHASE 1. pF ESS % A No. 64286 M rn Exp. 6/30/09 \�9r„ CIV 1131 W. SIXTH STREET, SUITE 350, ONTARIO, CA. 91762 PHONE: (909) 933-5225 FAX: (909) 933-5228 Prepared Under The Supervision Of : EF NAFTALI n n Date " NO SCALE 4 , �.._._........ MIT ST SCALE ` 1' 1 D PLAN PER I DESIGNED BY: DATE: 3/30/09 .C�4 DRAWING w. _011 f J i ,� • r 51152 Dv