SYMBOL BOTANICAL NAME COMMON NAME QUANTITY SIZE SPACING REFERENCE DETAILS
I f\CCJ
PYRUS CALLERYANA 'BRADFORD' BRADFORD CALLERY PEAR 1 36" BOX PER PLAN DETAIL STD. 3 AND 4 SEE SHEET 20
5 24' BOX
ALBIZIA JULIBRISSIN SILK TREE 5 15 GAL. PER PLAN DETAIL STD. 3 AND 4 SEE SHEET 20
PISTACIA CHINENSIS CHINESE PISTACHE 1 36' BOX PER PLAN DETAIL STD. 3 AND 4 SEE SHEET 20
8 15 GAL.
SHRUBS
O ANIGOZANTHOS FLAVIDUS RED KANGAROO PAW 333 1 GAL. PER PLAN DETAIL STD. 1 AND 2 SEE SHEET 20
Q PYRACANTHA 'SANTA CRUZ' FIRETHORN 60 5 GAL. PER PLAN DETAIL STD. 1 AND 2 SEE SHEET 20
® RHAPHIOLEPIS INDICA 'BALLERINA' BALLERINA INDIAN HAWTHORN 151 5 GAL. PER PLAN DETAIL STD. 1 AND 2 SEE SHEET 20
® LANTANA M. 'CONFETTI' TRAILING LANTANA 240 1 GAL. PER PLAN DETAIL STD. 1 AND 2 SEE SHEET 20
LANTANA MONTEVIDENSIS TRAILING LANTANA 27 1 GAL, PER PLAN DETAIL STD. 1 AND 2 SEE SHEET 20
O RHAPHIOLEPIS INDICA 'CLARA' CLARA INDIAN HAWTHORN 40 5 GAL. PER PLAN DETAIL STD. 1 AND 2 SEE SHEET 20
VINES
JASMINUM NITIDUM ANGELWING JASMINE 39 1 GAL. PER PLAN DETAIL STD. 1 AND 2 SEE SHEET 20
GRASS
98% CALIFORNIA NATIVE GRASS MIX NO.1— AGRONO TEC SEED CO. 4,641 SF.
2% SOUTHERN CALIFORNIA WILDFLOWER MIX— AGRONO TEC SEED CO.
CONTACT DON ALLISON (714) 719-0250 OR (951) 674-0638
(SEE PLANTING NOTES FOR HYDROSEED SPECIFICATIONS)
TURF (HYDROSEED) 3,305 SF.
III III ij� �`111 111 111
SYMBOL DESCRIPTION QUANTITY REFERENCE DETAILS
0
® o-�oo ° 0 ROCK BLANKET
oao oa 8oe
IN
I i
4 X 6 CONCRETE MOW STRIP
BOULDER SCHEDULE
SYMBOL
KEY
SIZE
QUANTITY
CITY
DATE
18" TO 24" DIA.
4 EA
A►E�O
1131 W. SIXTH STREET, SUITE 350, ONTARIO, CA. 91762
PHONE: (909) 933-5225 FAX: (909) 933-5228
ITY OF ' CALIFORNIA
24" TO 36" DIA.
5 EA
0
36" TO 48" DIA.
5 EA
SHOVEL CUT EDGE— PROJECT EDGE TREATMENT
BIKE TRAIL PAVING (REFER TO CILVIL ENGINEER'S PLANS)
'**' . I
ENHANCED PAVING (REFER TO CIVIL ENGINEER'S PLANS)
BOLLARDS (REFER TO CIVIL ENGINEER'S PLANS)
CONCRETE PAD— LIGHT FIXTURE (REFER TO CIVIL ENGINEER'S PLANS)
(4,547 SF.)
SITE FURNITURE— BENCH, DRINKING FOUNTAIN (REFER TO CIVIL ENGINEER'S PLANS)
PROJECT SIGNAGE (REFER TO CIVIL ENGINEER'S PLANS)
DETAIL 7 SEE SHEET 20
DETAIL 5 SEE SHEET 20
DETAIL 7 SEE SHEET 20
GENERAL PLANTING NOTES:
1) THE SHRUBS INDICATED FOR EACH PLANTING AREA IS TO COMPLETELY COVER ALL PLANTING AREA AT THE SPACING SPECIFIED.
2) REFER TO SPECIFICATIONS FOR STANDARDS TO BE VERIFIED BY THE CONTRACTOR.
3) PLANT MINIMUMS:
1 GAL = 10" MIN. HEIGHT
5 GAL = 18" MIN. HEIGHT
15 GAL = 1 1/47 CALIPER
24' BOX = 2" CALIPER
36" BOX = 3" CALIPER
4) ALL PLANTER AREAS TO BE SURFACED WITH 3" LAYER COMPOSTED ORGANIC MULCH AFTER PLANTING.
5) ROOT BARRIER TO BE INSTALLED FOR ALL TREES WITHIN (5) FIVE FEET OF PAVING EDGE.
6) APPLY APPROPRIATE PRE—EMERGENT HERBICIDE TO ALL SHRUB AND GROUND COVER AREAS AFTER INSTALLATION OF TREES AND SHRUBS AND
PREPARATION OF FINE GRADING.
7) REFER TO SPECIFICATIONS FOR STANDARDS OF MATERIALS AND WORKMANSHIP.
8) CONTRACTOR IS TO REVIEW PLANS. VERIFY SITE CONDITIONS AND PLANT QUANTITIES PRIOR TO INSTALLATION. CONFLICTS BETWEEN THE SITE
AND THESE PLANS OR WITHIN THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO LANDSCAPE INSTALLATION. ANY
DEVIATION(S) FROM THE PLANS OR SPECIFICATIONS IS TO HAVE WRITTEN APPROVAL.
9) THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HIMSELF FAMILIAR WITH ALL UNDERGROUND UTILITIES AND STRUCTURES. THE
CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ANY COST INCURRED DUE TO DAMAGE OF SAID UTILITIES OR STRUCTURES, IF PROPER
VERIFICATION BY CONTRACTOR WAS NOT PERFORMED.
10) DO NOT WILLFULLY PROCEED WITH PLANTING OPERATIONS AS DESIGNED WHEN IT IS OBVIOUS THAT UNKNOWN OBSTRUCTIONS AND/OR GRADE
DIFFERENCES EXIST THAT MAY NOT HAVE BEEN KNOWN DURING THE DESIGN PROCESS. SUCH CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE
ATTENTION OF THE ENGINEER.
11) THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ALL NECESSARY REVISIONS DUE TO FAILURE TO GIVE SUCH NOTIFICATION. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COORDINATION WITH SUBCONTRACTORS AS REQUIRED TO ACCOMPLISH HIS PLANTING OPERATIONS.
12) REFER TO THE SPECIFICATIONS FOR PLANTING REQUIREMENTS, MATERIALS AND EXECUTION.
13) ALL 24" BOX OR LARGER TREES SHALL BE TAGGED BY THE CONTRACTOR FOR APPROVAL BY THE OWNER'S AUTHORIZED REPRESENATIVE.
14) FINAL LOCATIONS OF ALL PLANT MATERIALS SHALL BE SUBJECT TO THE APPROVAL OF THE OWNER'S AUTHORIZED REPRESENTATIVE.
CONTRACTOR IS TO DO THE FOLLOWING BEFORE BEGINNING PLANTING OPERATIONS: A. SHRUBS AND GROUND COVER — LAY OUT THE ACTUAL
CONTAINERS ON—SITE PRIOR TO DIGGING HOLES.
15) THE CONTRACTOR SHALL NOTIFY THE OWNER'S AUTHORIZED REPRESENTATIVE AT LEAST 48 HOURS IN ADVANCE PRIOR TO COMMENCEMENT OF
WORK TO COORDINATE PROJECT OBSERVATION SCHEDULES.
16) IF CONFLICTS ARISE BETWEEN THE ACTUAL SIZE OF AREAS ON THE SITE AND THE DRAWINGS, THE CONTRACTOR SHALL CONTACT THE
OWNER'S AUTHORIZED REPRESENTATIVE FOR RESOLUTION. THE CONTRACTOR SHALL ASSUME FULL RESONSIBILITY FOR ALL NECESSARY REVISIONS
DUE TO FAILURE TO GIVE SUCH NOTIFICATION.
17) IT IS THE CONTRACTOR'S RESPONSIBILITY TO FURNISH PLANT MATERIAL FREE OF PESTS OR PLANT DISEASES. PRE—SELECTED — TAGGED"
PLANT MATERIAL MUST BE INSPECTED BY THE CONTRACTOR AND CERTIFIED PEST AND DISEASE FREE. IT IS THE CONTRACTOR'S OBLIGATION TO
WARRANTY ALL PLANT MATERIAL PER THE SPECIFICATIONS.
18) GROUND COVERS AND SHRUBS ARE TO BE TRIANGULARLY SPACED UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
19) AFTER FINISH GRADES HAVE BEEN ESTABLISHED FOR ALL ON—GRADE PLANTING AREAS, THE CONTRACTOR SHALL HAVE A MINIMUM OF 3 SOIL
SAMPLES TESTED BY WALLACE LABORATORIES, (310) 615-0116 FOR SOIL FERTILITY, AGRICULTURAL SUITABILITY, AND SOIL PREPARATION
RECOMMENDATIONS. THE CONTRACTOR WILL BE REQUIRED TO AMEND THE SOIL TO CONFORM TO THESE RECOMMENDATIONS.
�-
'\_p,NDSCgpF -� O REV.
4+fe W010�1 Ig �\
IEE� D11 110
®LLJ
CANDSCAPE .�. .r Signature +
� iz sa. zoao � � DIAL TWO WORKING
Renewal Date
BEFORE ��«� DAYS BEFORE
f�9 Dat e�P i YOU DIG YOU DIG
Q \F��%' TOLL FREE 1-800-227-2600
\�N A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REVISION DESCRIPTION
DATE
ENGR.
CITY
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN O
YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH !N A DILIGENT
MANNER THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM
'
INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT.
A►E�O
1131 W. SIXTH STREET, SUITE 350, ONTARIO, CA. 91762
PHONE: (909) 933-5225 FAX: (909) 933-5228
ITY OF ' CALIFORNIA
PACIFIC ELECTRIC INLAND EMPIRE TRAIL IMPROVEMENT
DRAWN BY:
K
SEGMENT 3A
TING LEGEND
SCALE:
Prepared Under The Supervision of
Date
DESIGNED BY:
G.O.
DATE:
3/30/09
CHECKED BY:
L.C.
AP VED BY:
�
DRAWING NO.:
4876
4
ARIEF NAFTALI
TTY ENGINEER R.C.E. 51152 DATE: