Loading...
HomeMy WebLinkAbout5588-1GENERAL NOTES: 1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. w 7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE - DIVISION OF INDUSTRIAL SAFETY. 8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT. 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13 CURVE DATA REFERS TO THE FACE OF CURB. 14 STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 15 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17 REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CML ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20 ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 21 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL 22 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF -THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY w NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 25 THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 26 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 27 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL 28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31 PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. 32 ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 33 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 34 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 35 CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. 36 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. NPDES NOTES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM 1. UNLESS NOTED OTHERWISE, ALL EXISTING SITE IMPROVEMENTS SHALL BE PROTECTED IN PLACE. 2. All EXISTING CONDITIONS ARE TO BE VERIFIED A T THE SITE PRIOR TO BIDDING. 3. CLEAN UP OF WORK AND SUPERVISION IS PART OF THE PROJECT. 4. CONSTRUCTION ACTIVITIES OF ONE ACRE OR MORE SHALL REQUIRE A GENERAL CONSTRUCTION STORMWATER PERMIT. FOR MORE INFORWATION, YOU MAY CALL THE STATE WATER RESOURCES CONTROL BOARD -DIVISION OF WATER QUAULITY AT (916) 657-1146. BENCHMARK: FIELD SURVEY RECORD BOOK 4015 PAGE 979 SET DRIVE PIN AND S.B. CO. SUR. TAG IN CONC. FOOTING AT N/W COR. 6' CLF S/E COR POPLAR AVE AND S.P.R.R., 1' f NO. AND 4f OF P.P. 1389176E. ELEVATION 1063.219 BASIS OF BEARINGS: THE N8746'57" E ALONG CENTERLINE OF BOYLE AVENUE PARCEL MAP 11177 BOOK 124-35, COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA, TAKEN AS THE BEARING FOR THIS SURVEY. w DIGJ A,,E ► T A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT STRE IMPROVEMENT 10407 ELM AVENUE CITY OF FONTANA LOCATION MAP TO LOS ANGELES INTERSTATE 10 QUANTITY O SAWCUT & REMOVE EXISTING AC PAVEMENT WITH GRIND/OVERLAY PER DETAIL W. (423 LF.)= 846 S.F. BOYLE AVE BOYLE AVE 410 LF. 000NSTRUCT COMMERCIAL DRIVEWAY APPROACH PER CITY STD. DWG. NO. 1002. (2 EA).= 810 S.F. O CONSTRUCT 4' SIDEWALK PER CITY OF FONTANA STD. DWG. NO. 1006. SITE O PLACE 8" AC DIKE PER CITY OF FONTANA STD. DWG. NO. 1007. NTS Os PLACE 6 1/2" MIN. AC PAVEMENT OVER 12" MIN. OF 957, COMPACTED NATIVE. (13,813 SLOVER AVE (DGRIND 0.10' MIN EXIST PAVEMENT AND OVERLAY 0.10' Q w O REMOVE EXISTING CHAIN LINK FENCE (REMOVED AS PART OF ON SITE IMPROVEMENTS) W > U 7,200 S.F. r ✓j\r rr1j\4 Q Q 1 EA. t t RELOCATE EXISTING FIRE HYDRANT. = w 1 EA- t2 RELOCATE EXISTING WATER VALVE. Q 3 1 EA. m w a 01 a _ 172 LF. SANTA ANA AVE a v LOCATION MAP CONSTRUCTION QUANTITIES: FOR BONDING - NOT FOR BIDDING QUANTITY O SAWCUT & REMOVE EXISTING AC PAVEMENT WITH GRIND/OVERLAY PER DETAIL W. (423 LF.)= 846 S.F. QCONSTRUCT 8" CURB & GUTTER PER CITY OF FONTANA STD. NO. 1000. 410 LF. 000NSTRUCT COMMERCIAL DRIVEWAY APPROACH PER CITY STD. DWG. NO. 1002. (2 EA).= 810 S.F. O CONSTRUCT 4' SIDEWALK PER CITY OF FONTANA STD. DWG. NO. 1006. 1,605 S.E. O PLACE 8" AC DIKE PER CITY OF FONTANA STD. DWG. NO. 1007. 171 LF. Os PLACE 6 1/2" MIN. AC PAVEMENT OVER 12" MIN. OF 957, COMPACTED NATIVE. (13,813 S.F.)=538 TONS (DGRIND 0.10' MIN EXIST PAVEMENT AND OVERLAY 0.10' MIN. 850 S.F. O REMOVE EXISTING CHAIN LINK FENCE (REMOVED AS PART OF ON SITE IMPROVEMENTS) 490 LF. O REMOVE AND DISPOSE OF EXISTING AC PAVEMENT. 7,200 S.F. G RELOCATE EXISTING WATER METER. 1 EA. t t RELOCATE EXISTING FIRE HYDRANT. 1 EA- t2 RELOCATE EXISTING WATER VALVE. 1 EA. t3 INSTALL OBJECT MARKERS PER MUTCD 3 EA - t4 APPLY 4" WHITE THERMO PLASTIC EDGE STRIPE. 172 LF. is SAWCUT AND REMOVE EXISTING CONCRETE CURB AND GUTTER. 245 LF. G SAWCUT AND REMOVE EXISTING CONCRETE SIDEWALK. 176 S.F. G CONSTRUCT PARKWAY DRAIN PER SPPWC STANDARD PLAN 151-2, TYPE 2 INLET. 1 EA. to FOLLOWING THE PLACEMENT OF AC PAVEMENT PER CONSTRUCTION NOTE 6, 377 S.F. BACKFILL AREA BETWEEN CURB AND DIKE WITH 6" CLEAN SANDAND 2" AC CAP PER SECTION A -A ON SHEET 2. GCONSTRUCT STREET LIGHT PER CITY OF FONTANA STD. NO. 404. 2 EA LEGEND: UTILITIES AC = ASPHALT CONCRETE WATER: BEG = BEGIN FONTANA WATER COMPANY BK = BACK 8440 NUEVO AVENUE BW = BACK OF WALK P.O. BOX 987 C&G = CURB & GUTTER FONTANA, CA 92234 C.L. = CENTER LINE (909) 822-2201 EXIST = EXISTING FG = FINISH GRAGE GAS: FL = FLOW UNE SOUTHERN CALIFORNIA GAS COMPANY FS = FINISH SURFACE 9781 SIERRA AVENUE #C MIN = MINIMUM FONTANA, CA 92335 OM = OBJECT MARKER (800)-427-2000 RT = RIGHT STA = STATION ELECTRICITY: S/W = SIDEWWALK SOUTHER CALIFORNIA EDISON TC = TOP OF CURB P. 0. BOX 600 TD = TOP OF DIKE ROSEMEAD, CA 91771-0001 TB = TOP OF BERM (909) 655-4555 -REMOVE EXIST AC PAVEMENT TELEPHONE: AT&T PROPOSED AC PAVEMENT PAYMENT CENTER SACRAMENTO, CA 95887-0001 CONCRETE COMMERCIAL SERVICE (800) 750-2253 CABLE TV: -0-- WV = WATER VALVE TIME WARNER CABLE 9820 SIERRA AVE #G FONTANA, CA 92335 WM = WATER METER (888) 892-2253 FH = FIRE HYDRANT SEWER: SEPTIC mmm %,LT; SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. T CL S'LY N'LY BOYLE AVE RAW R /W (33) 33 low 11 (22') so 22' 11' 9.5' (0.5' 10.5' & VARIES 10.5' 0.5' (4') (6.5') (12' & VARIES) (12' & VARIES) 6.5' 4' 3 I U SAWCUT REMOVE EXIST Z AC PAVEMENT 1_5 EE DETAIL "A" w -27 (290) 2% & VAR) 2� .�, -� _ &�� 290 �- _ 2:1 MAX T ( SLOPE !PE EXIST AC PAV'T CONSTRUCT SIDEWALK EXIST CURB & GUTTER EXIST SIDEWALK CONSTRUCT CURB & GUTTER BOYLE AVE PLACE AC OVER COMPACTED NATIVE TYP I CAL S ECTI 0 N NOT TO SCALE TI=9.0 I INDEX OF SHEETS SHEET 1 - TITLE SHEET SHEET 2 - PLAN AND PROFILE SHEET BOYLE AVE SHEET 3 - PLAN AND PROFILE SHEET ELM AVE SHEET 4 - STANDARD PLANS STORM WATER POLLUTION PREVENTION PROGRAM SW P P P NOTES BEST MANAGEWENT PRACTICES FOR CONSTRUCTION 1. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON SITE AND MAY NOT BE TRANSFED FROM THE SITE VIA SWALES, AREA DRAIN OR NATURAL DRAINAGE COURSES. 2. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. 3. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIAL MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS, ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM WEATHER, SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. 4. EXCESS OR WASTE CONCRETE WAY NOT BE WASHED IN THE PUBUC RIGHT OF WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO DRAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. 5. TRASH AND OTHER CONSTRUCTION RELATED DEBRIS MUST BE DEPOSITED INTO COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. 6. DEPOSITION OF SEDIWENTS, SOILS OR OTHER MATERIAL BY VEHICULAR TRAFFIC LEAVING THE PROJECT SITE MUST NOT BE ALLOWED. THE CONSTRUCION ENTRANCE ROADWAYS MUST BE STABILZED SO AS TO INHIBIT SEDIMENTS FROW BEING DEPOSITED INTO THE PUBLIC RIGHT-OF-WAY, ACCIDENTAL OR BY OTHER MEANS. 7. ANY SLOPE WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND AND WATER. ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THSE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OR CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY , AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROW ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROW THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. ASP 16-000002 PREPARED UNDER THE SUPERVISION OF: CITY O F- FO NTANA, CALI FO.R N W INLAND ENGINEERS EET IMp OVEMENT PLAN - & STR ASSOCIATES DRAWN BY: 10407 ELM AMEN U E SCALE: P.O. BOX 5485 WCH A.P.N. 0237-043-04 AS SHOWN REDLANDS. CA 92517 DESIGNED BY. TITLE SHEET DATE: (951) 907-9786 WCH CONSTRUCTION NOTES & QU ESTIMATES , A/;5/2017 of NECKED BY. APPR - D BY: DRAWING NO.: JL4 -�;- 17 �,MOHAMMAD SIDDIQUI DATE MSS CITY ENGINEER R.C.E. 51152 DATE5588 TOLL FREE `%66+ 1-800-227-260006, 1