HomeMy WebLinkAbout5597-6DREVEWAY DETAIL
SCALE: 1'=5'
DRIVEWAY DETAIL
SCALE: 1"=5'
4
6
9
m
16
20
DEMOLITION NOTES:
REMOVE EXISTING DRIVE APPROACH.
SAWCUT AND REMOVE EXISTING ASPHALT CONCRETE PAVEMENT,
SUBGRADE, AC CURB, AND/OR AC BERM.
REMOVAL OF EXISTING POWER POLE BY OTHERS. CONTRACTOR TO COORDINATE
WITH SOUTHERN CAUFORNIA EDISON FOR REMOVAL.
REMOVE AND REPLACE EXISTING MAIL BOX, AS SHOWN.
REMOVAL OF EXISTING WATER METER AND RELOCATION PER STREET IMPROVEMENT
PLAN BY OTHERS. CONTRACTOR TO COORDINATE WITH FONTANA WATER COMPANY
FOR RELOCATION.
PROTECT IN PLACE AS NOTED.
REMOVE AND REPLACE EXISTING LANDSCAPE AND IRRIGATION, IN KIND, AS REQUIRED
TO CONSTRUCT IMPROVEMENTS.
REMOVE AND RELOCATE EXISTING LIGHT POST, FOUNDATION, PULL BOXES,
AND CONDUIT SYSTEM.
REMOVE AND REPLACE EXISTING ROD IRON ROLLING GATE, ROLLING GATE TRACK AND FENCE INCLUDING
TRACK AND FENCE POST FOOTINGS, IN KIND AS REQUIRED TO CONSTRUCT IMPROVEMENTS.
STREET IMPROVEMENT CONSTRUCTION NOTES:
0 CONSTRUCT 8" CURB AND GUTTER PER CITY OF FONTANA STD. PLAN NO. 1000.
0 CONSTRUCT SIDEWALK, WIDTH AS SHOWN, PER CITY OF FONTANA STD. PLAN NO. 1006.
0 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY OF FONTANA STD. PLAN NO. 1002, R=12'.
REVISED PER DRIVEWAY DETAIL, SHEET 2 AND 6, UNLESS NOTED OTHERWISE.
0 CONSTRUCT 6" OF ASPHALT CONCRETE PAVEMENT OVER 1.0' OF 95% COMPACTED
NATIVE SOIL.
7O CONSTRUCT 4" ASPHALT CONCRETE PRIVATE DRIVEWAY APPROACH/PRIVATE PARKING
OVER 95% COMPACTED NATIVE SOIL.
11 RELOCATE EXISTING WATER SERVICE BY FONTANA WATER COMPANY. CONTRACTOR TO
COORDINATE WITH FONTANA WATER COMPANY FOR RELOCATIONS.
12 RELOCATE EXISTING POWER POLE. CONTRACTOR TO COORDINATE WITH SCE FOR
RELOCATIONS.
14 CONSTRUCT LANDSCAPE AND IRRIGATION TO MATCH EXISTING.
15 CONSTRUCT CONCRETE CROSS GUTTER TO MATCH EXISTING.
16 RELOCATE EXISTING UGHT POST, FOUNDATION, PULL BOXES, AND CONDUIT SYSTEM.
D
•
••p:..
SECTIONS LEGEND:
EXISTING CURB, GUTTER AND/OR SIDEWALK
PROPOSED CURB, GUTTER AND/OR SIDEWALK
SCALE: 1"=5'
Underground Service Alert
SECTION 4216/4217 OF THE GOVERNMENT
CODE REQUIRES A DIG ALERT IDENTIFICATION
NUMBER BE ISSUED BEFORE A PERMIT TO
EXCAVATE WILL BE VAUD
FOR YOUR DIG ALERT I.D. NUMBER CALL
A . UNDERGROUND SERVICE ALERT
TOLL FREE 811
TWO WORKING DAYS BEFORE YOU DIG
'LIEN I: CI IY Oh FONTANA
TKE JOB #: 101-55
05/16/12
REV.
REVISION DESCRIPTION
DATE
EN GR.
CITY
DATE
TKE ENGINEERING, INC.
2305 CHICAGO AVENUE
RIVERSIDE, CA 92507
(951) 680-0440
ERING FAX (951) 680-0490
TERRY . RENNER R.C.E. No. 69984
EXPIRES: 9-30-18
STREET IMPROVEMENTS
FOOTHILL BOULEVARD
SIERRA AVENUE TO
MANGO AVENUE
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT COMMENCE
WITHIN TWO YEARS OF THE DATE OF
APPROVAL SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER, THE CITY
ENGINEER MAY REQUIRE REVISIONS TO
THE PLANS TO BRING THEM INTO
CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLANS
DRAWN BY:
JAM
DESIGNED BY:
TMR
CHECKED BY:
TMR
FOOTHILL BOULEVARD MEDIAN IMPROVEMENTS
DETAILS 2 OF 2
APPROVED BY:
CITY ENGINEER
Z- 2/. /7
R.C.E. No. 51152
AS SHOWN
DATE:
JULY 2017
DRAWING NO.:
5597