HomeMy WebLinkAbout5052REF-15. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS
- AND PROCEDURES DESCRIBED IN THE STATE OF CAUFORNIA MANUAL OF TRAFFIC
CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY
TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH
WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE
DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED
MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY
OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE
GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVE
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY
WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE
CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600
TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT LIMM TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE
NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE CITY ENGINEER
TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT
TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A
REGISTERED CML ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS
THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE
REPLACED. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER ONE WEEK PRIOR
TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES
AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN
THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST
CONTROL. INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND
VELOCITIES EXCEED 25 MILES PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR
DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE
RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY
INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO
OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF
THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY
ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING
IMPROVEMENTS.
25. LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE DETERMINED AT
THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA
STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH
TO MATCH EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN 'S'IN THE FACE OF THE CURB AT THE
LOCATION OF THE SEWER LATERAL
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE
BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO
PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR
TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION
AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN
AFTER POMPLETION OF ROUGH GRADING.
- • BENCH MARK I BASIS OF BEARING
SAN BERNARDINO BOUNTY BM 8-179
NEAR HIGHLAND AVENUE & SAN SEVAINE AVE,
343' NORTH OF HIGHLAND AVE, & 0.20 MI
WEST OF SAN SEVAINE AVE, 265 MI WEST
ALONG HIGHLAND AVE. FROM SIERRA AVE
ELEV.= 1428.609
THE CENTERLINE FROM AMERICA AVE. TO
THE BC WEST OF CHERIMOYA AVE
BEING NORTH 89'42'20' E PER RICK
ENGINEERING AUTOCAD DRAWING.
CITY OF FO TA A
SOUTH HIGHLAND AVENUE STREET IMPROVEMENT PROJECT
PHASE 11
FROM CHERRY AVENUE YO SAN SEVAINE ROAD
GENERAL NOTES CONTINUED:
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR
STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL
REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON
COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO
FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING,
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE
SATISFACTION OF THE CITY TRAFFIC ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND
SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY
ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY.
O
D 0,Aka
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
I�.T:7:3.`�a:3:r.>i:ii►,:`�:d::r::1...�I fru o�
I INDICATES PROPOSED A.C. PAVEMENT
i///////� INDICATES RE]WOVE EXISTING > >
INDICATES GRIND AND OVERLAY
INDICATES CENTERUNE
INDICATES ' 1
INDICATES EXISTING IMPROVEMENTS
INDICATES EXISTING/ /
q
GENERAL NOTES:
ROW
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA
LT
STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS
RT
FOR PUBLIC WORKS CONSTRUCTION -GREEN BOOK ALL REFERENCE
_
SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE
EC
NOTED.
PRC
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS
EX
THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE
PT
'GREEN BOOK% THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO
TC
THE CITY ENGINEER FOR RESOLUTION.
PLANS STA
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY
.. _
ENGINEER.
SOUTH
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA
AVENUE
COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START
IMPROVEMENT
OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO
14+00
WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY
5.
WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS
- AND PROCEDURES DESCRIBED IN THE STATE OF CAUFORNIA MANUAL OF TRAFFIC
CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY
TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH
WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE
DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED
MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY
OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE
GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVE
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY
WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE
CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600
TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT LIMM TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE
NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE CITY ENGINEER
TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT
TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A
REGISTERED CML ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS
THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE
REPLACED. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER ONE WEEK PRIOR
TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES
AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN
THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST
CONTROL. INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND
VELOCITIES EXCEED 25 MILES PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR
DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE
RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY
INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO
OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF
THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY
ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING
IMPROVEMENTS.
25. LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE DETERMINED AT
THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA
STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH
TO MATCH EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN 'S'IN THE FACE OF THE CURB AT THE
LOCATION OF THE SEWER LATERAL
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE
BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO
PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR
TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION
AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN
AFTER POMPLETION OF ROUGH GRADING.
- • BENCH MARK I BASIS OF BEARING
SAN BERNARDINO BOUNTY BM 8-179
NEAR HIGHLAND AVENUE & SAN SEVAINE AVE,
343' NORTH OF HIGHLAND AVE, & 0.20 MI
WEST OF SAN SEVAINE AVE, 265 MI WEST
ALONG HIGHLAND AVE. FROM SIERRA AVE
ELEV.= 1428.609
THE CENTERLINE FROM AMERICA AVE. TO
THE BC WEST OF CHERIMOYA AVE
BEING NORTH 89'42'20' E PER RICK
ENGINEERING AUTOCAD DRAWING.
CITY OF FO TA A
SOUTH HIGHLAND AVENUE STREET IMPROVEMENT PROJECT
PHASE 11
FROM CHERRY AVENUE YO SAN SEVAINE ROAD
GENERAL NOTES CONTINUED:
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR
STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL
REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON
COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO
FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING,
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE
SATISFACTION OF THE CITY TRAFFIC ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND
SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY
ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY.
O
D 0,Aka
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
I�.T:7:3.`�a:3:r.>i:ii►,:`�:d::r::1...�I fru o�
I INDICATES PROPOSED A.C. PAVEMENT
i///////� INDICATES RE]WOVE EXISTING > >
INDICATES GRIND AND OVERLAY
INDICATES CENTERUNE
INDICATES ' 1
INDICATES EXISTING IMPROVEMENTS
INDICATES EXISTING/ /
q
CENTERLINE
ROW
RIGHT OF WAY
LT
LEFT
RT
RIGHT
BC
BEGIN CURVE
EC
END CURVE
PRC
POINT OF REVERSE CURVE
EX
EXISTING
PT
POINT
TC
TOP OF CURB
UTLITY NOTMATION
CITY OF FONTANA
ATTN : ENGINEERING
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-7610
SO. CALIF. GAS COMPANY
ATTN: TIEPREE LEE
1981 W. LUGONIA AVENUE
REDLANDS, CA 92374
(909) 335-7756
(6
EMERGENCIES. (800) 427-2200
SO. CALIF. EDISON COMPANY
ATTN: TIM KEETLE
300 N. PEPPER AVENUE
RIALTO, CAL 92376
(909) 631-3817
CRAWFORD CANYON MUTUAL WATER CO.
ATTN: BASIL J. FABRIZIO
6101 CHERRY AVE. SUITE 109
FONTANA, CA 92336
(909) 463-9580
REV19011 0E5DW IW DATE UM CRY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS
TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
ATT
ATTN: JASON PARK
3939 E CORONADO STREET
ANAHEIM, CA. 92807
(714) 666-5415
UNDERGROUND SERVICE ALERT
(800) 227-2600
TIME -WARNER (CABLE TV)
ATTN: LEWIS McDONALD
1500 ALTO CENTER DRIVE
ONTARIO, CA 91761
(909) 975-3343
(888) 892-2253
FONTANA WATER COMPANY
ATTN: BRENDA FOWLER
15966 ARROW ROUTE
FONTANA, CA 92335
909) 822-2201
AX: (909) 823-5046
r
D6469606 30 11
u
LOCA
t r`
INDEX OF SHEETS
1.
SOUTH HIGHLAND AVE
WALNUT AVE
'<
FCWANA
x
U
2.
TYPICAL
m
BASELINE AVE
1.
TITLE SHEET
2.
TYPICAL
SECTIONS, DETAILS AND INDEX MAP
3.
SOUTH
HIGHLAND
AVENUE
STREET
IMPROVEMENT
PLANS STA
10+00
TO STA 14+00
4.
SOUTH
HIGHLAND
AVENUE
STREET
IMPROVEMENT
PLANS STA
14+00
TO STA 22+00
5.
SOUTH
HIGHLAND
AVENUE
STREET
IMPROVEMENT
PLANS STA
22+00
TO STA 30+00
6.
SOUTH
HIGHLAND
AVENUE
STREET
IMPROVEMENT
PLANS STA
30+00
TO STA 36+00.97
7.
CHERRY
AVENUE
STREET IMPROVEMENT PLANS STA 6+89.71
TO STA
13+36.98
8.
SOUTH
HIGHLAND
AVENUE
STREET
IMPROVEMENT
STRIPING PLANS STA 10+00 TO STA 30+00
9.
SOUTH
HIGHLAND
AVENUE
STREET
IMPROVEMENT
STRIPING PLANS STA 30+00 TO STA 36+00
PRIVATE ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES
SHOWN ON THESE PLANS WERE OBTAINED BY SEARCH OF THE AVAILABLE RECORDS.
THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR,
SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF
THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER
LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS.
CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY- THAT THIS
REQUIREMENT SHALL BE MADE TO APPLY C0I4TIN000SLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO
DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL
LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON
THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN
PROFESSIONAL
UNAUTHORIZED CHANGES do USES: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE
PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY
THE PREPARER OF THESE PLANS.