Loading...
HomeMy WebLinkAbout5439-1CITY OF FONTANA VALLEY BLVD AND OLEANDER AVE TRAFFIC SIGNAL GENERAL NOTES TRAFFIC SIGNAL IMPROVEMENTS. TRAFFIC SIGNAL CONSTRUCTION NOTES 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITH IN THE CITY LIMITS. CALL (909) 350-7610. 2. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE STANDARD PLANS AND SPECIFICATIONS OF THE STATE OF CALIFORNIA, DATED 2015, AND THE CALIFORNIA MANUAL OF TRAFFIC CONTROL DEVICES, DATED 2014. 3. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT 811 TWO (2) WORKING DAYS BEFORE DIGGING. 4. CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT ANY CITY FURNISHED OR PROVIDED AS NOTED IN SECTION E. 5. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 3" RIGID METAL UNLESS OTHERWISE SHOWN. 6. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH SOUTHERN CALIFORNIA EDISON COMPANY FOUR WEEKS IN ADVANCE OF NEED. 7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND SECTION E. 8. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 9. CONTROLLER AND SERVICE CABINETS SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. CONTRACTOR SHALL MODIFY SPRINKLERS SYSTEMS AS NECESSARY. 10. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW TRAFFIC SIGNALS AND LIGHTING. 11. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND,OR SPECIFICATIONS FOR THIS PROJECT. 12. TRENCH REPAIRS SHALL BE PER SPECIAL PROVISIONS, SECTION E AND CITY STANDARD PLAN 1008. 13. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO THE CITY ENGINEER. UNDERGROUND SERVICE ALERT (USA) IT'S THE LAW! DIAL BEFORE ! YOU DIG! CALL AT LEAST o TWO WORKING DAYS Know what's below. BEFORE YOU DIG Call before you dig. LEGEND: -4}— PROPOSED SIGNAL EQUIPMENT OPROPOSED TYPE E LOOP PROPOSED TYPE D LOOP Ceres Ave Merrill Ave Q P N �r ' North Randall Ave >> > Q Q Q > > Q '0cu cm Ca (6 7A U O U � 2E San Bernardino Ave Valley Blvd LZ yj -7- __T SIGN LEGEND: R3-4 36'X36' PROJECT SITE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH REV. REVISION DESCRIPTION DATE ENGR. I CITY DATE STANDARDS IN EFFECT. VICINITY MAP NOT TO SCALE O99.0FESS10,y� _ KOL 1 oRpo noN ,,A0 GU �Fy PLANNING & ENGINEERING ?, 3190 C Shelby Street No. 75793 Ontario, California 91764 Tel: (909) 890-9693 Fax: (909) 890-9694 * EXP. 6/30/18 BENCH MARK:B.M. NO. 274 ELEVATION=1,244.23 aVIL �lgTEOF CAUF���\P DESCRIPTION: BEARINGS SHOWN ARE BASED UPON THE CENTERLINE OF OLEANDER AVENUE AS SHOWN ON RECORD OF SURVEY RECORDED IN RS BOOK 43, PAGE 5, RECORDS OF THE COUNTY OF SAN BERNARDINO, CA. NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT ANDIOR MATERIALS. �1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE `R" CABINET, LOOP DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD PLAN 4001. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. ❑2 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. a FURNISH & INSTALL 2"C, 2#6, 1#8 G.H.C.I. (SIGNAL SERVICE) a FURNISH & INSTALL 2"C, 2#10 (LUMINAIRES) a FURNISH AND INSTALL 3" PVC CONDUIT WITH X" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE PLANNING DEPARTMENT AT 909.357.6116. VERIFY PHONE NUMBERS AT TIME OF CONSTRUCTION ❑6 REMOVE EXISTING LANDSCAPING AND MODIFY IRRIGATION SYSTEM AS NECESSARY. CONSTRUCT 4" THICK PCC PAD ON COMPACTED NATIVE AROUND PROPOSED SIGNAL CONTROLLER AND SERVICE CABINETS. SPRINKLERS SHALL NOT SPRAY ONTO CONTROLLER CABINET OR SERVICE PEDESTAL aj INSTALL CITY -FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, PER DETAIL A THIS SHEET AND AS DIRECTED BY THE ENGINEER ® INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N. ❑9 FURNISH AND INSTALL BATTERY BACK UP UNIT PER MANUFACTURERS REQUIREMENTS. 10 REMOVE STREET LIGHT (BY SCE) AFTER SIGNAL IS ENERGIZED 11 FURNISH & INSTALL P48 SPLICE VAULT WITH SPLIT FIBERGLASS LID. SPLICE VAULT SHALL BE LABELED COMMUNICATIONS. FURNISH & INSTALL SPLICE CANISTER. TERMINATE DESIGNATED FIBERS FROM 6 STRAND SMFO CABLE TO 12 STRAND SMFO CABLE. 12 FURNISH & INSTALL 2"C, 1-6 PAIR #22 SIC, & 1-12 STRAND SMFO CABLE. 13 TERMINATE 12 STRAND SMFO CABLE TO WALL INTERCONNECT UNIT LOCATED IN SIGNAL CONTROLLER CABINET. CITY TO PROVIDE FIBER SPLICE CHART. TERMINATE SIC TO PUNCH DOWN BLOCK 14 FURNISH & INSTALL 1-3" PVC CONDUIT BY DIRECTIONAL DRILL UNDER PAVEMENT OR SIDEWALK CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM OF 10 -FOOT RADIUS. APPROX. 1300' TO EXISTING P48 VAULT ON NORTHWEST CORNER AT CYPRESS/VALLEY. 15 FURNISH & INSTALL 1-96 STRAND SMFO CABLE & 1-6 PAIR #22 SIC APPROX. 1300' TO CYPRESS/VALLEY. TIE INTO EXISTING VAULT ON NORTHWEST CORNER. 16 FURNISH & INSTALL P48 SPLICE VAULT EVERY 400'-500', COIL ADDITIONAL 25' OF 96 STRAND SMFO & 25' OF 6 PAIR SIC IN EACH P48 SPLICE VAULT. LEGEND: REMOVE EXISTING PROPOSED -" TYPE IV (L or R) PAVEMENT ARROW r a ROADSIDE SIGN ------------ TRAFFIC STRIPE OR MARKING Prepared Under The Supervision Of : DATE: R.C.E. INDEX OF SHEETS: 5438 -STREET IMPROVEMENT PLAN 5439 -TRAFFIC SIGNAL PLAN 5440 -SIGNING AND STRIPING PLAN CITY OF FONTANA, CALIFORNIA TITLE SHEET DRAWN BY: VALLEY BOULEVARD SCALE: As Noted DESIGNED BY: AND DATE: OLEAND R AVENUE CHECKED BY:<, -[AP PR D Y: c� DRAWING NO.: X2. DATt3_ ! ' 5439 CI ENGINEER—R.C.E. 51152