HomeMy WebLinkAbout5439-1CITY OF FONTANA
VALLEY BLVD AND OLEANDER AVE
TRAFFIC SIGNAL GENERAL NOTES TRAFFIC SIGNAL IMPROVEMENTS. TRAFFIC SIGNAL CONSTRUCTION NOTES
1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT
OF ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN
PUBLIC RIGHT-OF-WAY WITH IN THE CITY LIMITS. CALL (909) 350-7610.
2. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM
TO THESE PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE STANDARD
PLANS AND SPECIFICATIONS OF THE STATE OF CALIFORNIA, DATED 2015, AND THE
CALIFORNIA MANUAL OF TRAFFIC CONTROL DEVICES, DATED 2014.
3. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL
POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE
JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE
UNDERGROUND SERVICE ALERT AT 811 TWO (2) WORKING DAYS BEFORE DIGGING.
4. CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT
THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT ANY CITY
FURNISHED OR PROVIDED AS NOTED IN SECTION E.
5. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 3" RIGID METAL UNLESS
OTHERWISE SHOWN.
6. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH
SOUTHERN CALIFORNIA EDISON COMPANY FOUR WEEKS IN ADVANCE OF NEED.
7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND SECTION E.
8. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
9. CONTROLLER AND SERVICE CABINETS SHALL NOT BE SUBJECTED TO WATER FROM
SPRINKLERS. CONTRACTOR SHALL MODIFY SPRINKLERS SYSTEMS AS NECESSARY.
10. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL
REPLACED WITH NEW TRAFFIC SIGNALS AND LIGHTING.
11. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR
POTENTIAL CONFLICT WITH THESE PLANS AND,OR SPECIFICATIONS FOR THIS PROJECT.
12. TRENCH REPAIRS SHALL BE PER SPECIAL PROVISIONS, SECTION E AND CITY STANDARD
PLAN 1008.
13. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO
THE CITY ENGINEER.
UNDERGROUND SERVICE ALERT (USA)
IT'S THE LAW!
DIAL BEFORE !
YOU DIG!
CALL AT LEAST o
TWO WORKING DAYS Know what's below.
BEFORE YOU DIG Call before you dig.
LEGEND:
-4}— PROPOSED SIGNAL EQUIPMENT
OPROPOSED TYPE E LOOP
PROPOSED TYPE D LOOP
Ceres Ave
Merrill Ave
Q
P
N
�r '
North
Randall Ave
>> >
Q
Q Q >
>
Q '0cu cm
Ca (6
7A
U O U � 2E
San Bernardino Ave
Valley Blvd
LZ yj
-7- __T
SIGN LEGEND:
R3-4
36'X36'
PROJECT SITE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
REV. REVISION DESCRIPTION DATE ENGR. I CITY DATE STANDARDS IN EFFECT.
VICINITY MAP
NOT TO SCALE
O99.0FESS10,y� _ KOL 1 oRpo noN
,,A0 GU �Fy PLANNING & ENGINEERING
?, 3190 C Shelby Street
No. 75793 Ontario, California 91764
Tel: (909) 890-9693 Fax: (909) 890-9694
*
EXP. 6/30/18
BENCH MARK:B.M. NO. 274 ELEVATION=1,244.23
aVIL
�lgTEOF CAUF���\P DESCRIPTION: BEARINGS SHOWN ARE BASED UPON THE CENTERLINE OF OLEANDER AVENUE AS
SHOWN ON RECORD OF SURVEY RECORDED IN RS BOOK 43, PAGE 5, RECORDS OF
THE COUNTY OF SAN BERNARDINO, CA.
NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT ANDIOR MATERIALS.
�1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING
TYPE `R" CABINET, LOOP DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER
CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD PLAN 4001.
CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED
TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN.
❑2 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA
AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS.
a FURNISH & INSTALL 2"C, 2#6, 1#8 G.H.C.I. (SIGNAL SERVICE)
a FURNISH & INSTALL 2"C, 2#10 (LUMINAIRES)
a FURNISH AND INSTALL 3" PVC CONDUIT WITH X" POLY PULL ROPE PER SCE
REQUIREMENTS. COORDINATE SERVICE WITH SCE PLANNING DEPARTMENT AT 909.357.6116.
VERIFY PHONE NUMBERS AT TIME OF CONSTRUCTION
❑6 REMOVE EXISTING LANDSCAPING AND MODIFY IRRIGATION SYSTEM AS NECESSARY.
CONSTRUCT 4" THICK PCC PAD ON COMPACTED NATIVE AROUND PROPOSED SIGNAL
CONTROLLER AND SERVICE CABINETS. SPRINKLERS SHALL NOT SPRAY ONTO CONTROLLER
CABINET OR SERVICE PEDESTAL
aj INSTALL CITY -FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR,
PER DETAIL A THIS SHEET AND AS DIRECTED BY THE ENGINEER
® INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N.
❑9 FURNISH AND INSTALL BATTERY BACK UP UNIT PER MANUFACTURERS REQUIREMENTS.
10 REMOVE STREET LIGHT (BY SCE) AFTER SIGNAL IS ENERGIZED
11 FURNISH & INSTALL P48 SPLICE VAULT WITH SPLIT FIBERGLASS LID. SPLICE VAULT SHALL
BE LABELED COMMUNICATIONS. FURNISH & INSTALL SPLICE CANISTER. TERMINATE
DESIGNATED FIBERS FROM 6 STRAND SMFO CABLE TO 12 STRAND SMFO CABLE.
12 FURNISH & INSTALL 2"C, 1-6 PAIR #22 SIC, & 1-12 STRAND SMFO CABLE.
13 TERMINATE 12 STRAND SMFO CABLE TO WALL INTERCONNECT UNIT LOCATED IN SIGNAL
CONTROLLER CABINET. CITY TO PROVIDE FIBER SPLICE CHART. TERMINATE SIC TO PUNCH
DOWN BLOCK
14 FURNISH & INSTALL 1-3" PVC CONDUIT BY DIRECTIONAL DRILL UNDER PAVEMENT OR
SIDEWALK CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM OF 10 -FOOT RADIUS.
APPROX. 1300' TO EXISTING P48 VAULT ON NORTHWEST CORNER AT CYPRESS/VALLEY.
15 FURNISH & INSTALL 1-96 STRAND SMFO CABLE & 1-6 PAIR #22 SIC APPROX. 1300' TO
CYPRESS/VALLEY. TIE INTO EXISTING VAULT ON NORTHWEST CORNER.
16 FURNISH & INSTALL P48 SPLICE VAULT EVERY 400'-500', COIL ADDITIONAL 25' OF 96
STRAND SMFO & 25' OF 6 PAIR SIC IN EACH P48 SPLICE VAULT.
LEGEND:
REMOVE EXISTING PROPOSED
-" TYPE IV (L or R) PAVEMENT ARROW
r a ROADSIDE SIGN
------------ TRAFFIC STRIPE OR MARKING
Prepared Under The Supervision Of :
DATE:
R.C.E.
INDEX OF SHEETS:
5438 -STREET IMPROVEMENT PLAN
5439 -TRAFFIC SIGNAL PLAN
5440 -SIGNING AND STRIPING PLAN
CITY OF FONTANA, CALIFORNIA
TITLE SHEET
DRAWN BY: VALLEY BOULEVARD SCALE:
As Noted
DESIGNED BY: AND DATE:
OLEAND R AVENUE
CHECKED BY:<, -[AP PR D Y: c� DRAWING NO.: X2.
DATt3_ ! ' 5439
CI ENGINEER—R.C.E. 51152