GENERAL NOTES
24.
GUARANTEE: THE ENTIRE IRRIGATION SYSTEM INCLUDING ALL
A.
TWO SETS OF SPECIAL TOOLS REQUIRED FOR
WORK DONE UNDER THIS CONTRACT, SHALL BE GUARANTEED
TYPE OF IRRIGATION HEAD AND VALVE SUPPLIED.
B.
AGAINST ALL DEFECTS AND FAULT OF MATERIAL AND
1.
BIDDING: IT SHALL BE THE OWNER'S RESPONSIBILITY IN
C.
WORKMANSHIP, AND SHALL MAINTAINED IN PREFECT
INVITING AND OBTAINING BIDS, SETTING ITS PROVISIONS AND
WORKING ORDER FOR ONE OF
(1 YEAR FROM DATE
D.
INSTRUCTIONS TO BIDDERS, SECURING THEIR BONDS AND
COMPLETION BY THE CONTRACTOR WITHOUT EXPENSE TO
WORKERS COMPENSATION INSURANCE CERTIFICATES, ETC. TO
THE OWNER ALL MATERIALS USED SHALL CARRY A
FULLY ENSURE THE QUALITY AND TIMELY COMPLETION OF THE
MANUFACTURER'S GUARANTEE OF MINIMUM ONE (1) YEAR. ANY
PROJECT.
SETTLING OF BACKFILLED TRENCHES WHICH MAY OCCUR
DURING THE ONE YEAR PERIOD FINAL ACCEPTANCE SHALL BE
2.
SCOPE OF WORK: CONTRACTOR SHALL PROVIDE ALL LABOR,
REPAIRED TO THE OWNER'S SATISFACTION BY THE
MATERIALS, EQUIPMENT AND SERVICES NECESSARY TO
CONTRACTOR WITHOUT EXPENSE TO THE OWNER - INCLUDING
FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM AS
THE COMPLETE RESTORATION OF ALL DAMAGED PLANTING,
PER THE DRAWINGS AND SPECIFIED HEREIN.
PAVING OR OTHER IMPROVEMENTS OF ANY KIND.
3.
PLAN VERIFICATION THESE DOCUMENTS MAY CONTAIN
ERRORS, OMISSIONS, CONTRADICTIONS, ETC. THE
B
FIELD OBSERVATIONS
CONTRACTOR SHALL REVIEW ALL DOCUMENTS THORUGHLY
.
AND SHALL NOTIFY THE LANDSCAPE ARCHITECT AND OWNER
1.
REQUIRED FIELD OBSERVATION WORK: THESE PLANS WERE
IMMEDIATELY UPON ANY SUCH DISCOVERY OF DISCREPANCY.
PREPARED WITH THE UNDERSTANDING THAT THE OWNER OF
GOVERNING CODES SHALL THEN APPLY.
SAID PLANS WILL USE PROFESSIONAL DESIGN ASSOCIATES TO
PROVIDE "FULL" CONTRACT SERVICES INCLUDING FIELD
4.
LICENSE: THE CONTRACTOR SHALL BE A C-27 CALIFORNIA
OBSERVATION SERVICES DURING CONSTRUCTION. FAILURE TO
STATE LICENSED IRRIGATION CONTRACTOR.
USE PROFESSIONAL DESIGN ASSOCIATES TO PROVIDE AND
5.
ORDINANCES AND REGULATIONS: ALL IRRIGATION WORK
COMPLETE THE FIELD OBSERVATION SERVICES SET FORTH
HEREIN WILL SIGNIFICANTLY INCREASE THE
WITHIN THESE DRAWINGS AND SPECIFICATIONS SHALL
MISINTERPRETATION OF THE INTENT OF THE DESIGN. ANY
CONFORM TO ALL APPLICABLE GOVERNING CODES AND
UNAUTHORIZED MODIFICATIONS THERETO, AND FAILURE TO
ORDINANCES (LOCAL, COUNTY & STATE).
DETECT ERRORS AND OMISSIONS IN THE PLANS AND
SPECIFICATIONS CAN BECOME COSTLY MISTAKES BUILT INTO
6.
PERMITS AND INSPECTIONS: THE CONTRACTOR SHALL
THE PROJECT. THEREFORE, IN THE EVENT THAT PROFESSIONAL
OBTAIN, COORDINATE AND PAY FOR ALL PERMITS, FEES AND
DESIGN ASSOCIATES IS OTHERWISE PRECLUDED FROM
AGENCY INSPECTIONS AS REQUIRED.
COMPLETING THE FIELD OBSERVATION SERVICES SET FORTH
HEREIN, THE OWNER, OR SUBSEQUENT OWNER (INDIVIDUALS
7.
FIELD VERIFICATION: CONTRACTOR SHALL VERIFY ALL
OR CORPORATIONS WHO HAVE PURCHASED THESE PLANS
DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK.
WITH THE PROJECT), AGREES TO HOLD HARMLESS, INDEMNIFY,
THE CONTRACTOR SHALL NOT WILLFULLY INSTALL THE
AND DEFEND PROFESSIONAL DESIGN ASSOCIATES AND THEIR
IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS
CONSULTANTS FROM AND AGAINST ANY AND ALL CLAIMS.
OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS,
GRADE DIFFERENCES OR DISCREPANCIES IN AREA DIMENSIONS
2.
FIELD OBSERVATION COORDINATION: THE FOLLOWING
EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN IRRIGATION
OBSERVATIONS SHALL BE INITIATED BY THE CONTRACTOR AND
DESIGN. THE LANDSCAPE ARCHITECT AND OWNER SHALL BE
COORDINATED THROUGH THE OWNER (JOB SUPERINTENDENT).
NOTIFIED IMMEDIATELY UPON ANY DISCOVERY OF
THE CONTRACTOR SHALL NOTIFY THE OWNER (JOB
DISCREPANCIES. IN THE EVENT THIS NOTIFICATION IS NOT
SUPERINTENDENT) AND LANDSCAPE ARCHITECT NOT LESS
PERFORMED, THE IRRIGATION CONTRACTOR SHALL ASSUME
THAN FORTY-EIGHT (48) HOURS IN ADVANCE OF ANY
FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY.
OBSERVATION. CONTINUED WORK WITHOUT OBSERVATION OF
THESE PHASES OF WORK IS AT THE CONTRACTOR'S RISK, WITH
8.
LIABLE FOR ENCROACHMENT: THE CONTRACTOR SHALL BE
ANY REQUIRED CHANGES OR MODIFICATIONS TO BE AT THE
RESPONSIBLE FOR ANY ENCROACHMENT ONTO ADJACENT
CONTRACTOR'S EXPENSE. THE OWNER (JOB
PROPERTY, RIGHT-OF-WAYS, EASEMENTS, SET -BACKS OR ANY
SUPERINTENDENT) SHALL INFORM THE LANDSCAPE ARCHITECT
OTHER LEGAL PROPERTY RESTRICTIONS EITHER MARKED OR
AS TO THE PURPOSE AND TIME OF THE OBSERVATION FORTY -
UNMARKED.
EIGHT (48) HOURS IN ADVANCE.
9.
METHODS OF CONSTRUCTION: THE CONTRACTOR IS SOLELY
3.
CLOSING OF NON INSPECTED WORK THE CONTRACTOR SHALL
RESPONSIBLE FOR ALL CONSTRUCTION METHODS, MEANS,
NOT ALLOW NOR CAUSE ANY OF THE WORK TO BE COVERED
SEQUENCES, PROCEDURES AND TECHNIQUES. THE
OR ENCLOSED UNTIL IT HAS BEEN INSPECTED, TESTED AND
LANDSCAPE ARCHITECTURAL FIRM IS NOT LIABLE FOR
APPROVED BY THE CONSULTING ENGINEER OR AUTHORIZED
CONSTRUCTION METHODS.
REPRESENTATIVE AND/OR GOVERNMENTAL AUTHORITY HAVING
10.
SAFETY: THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
JURISDICTION OVER THE WORK. SHOULD ANY OF THE WORK
BE ENCLOSED OR COVERED BEFORE SUCH INSPECTION AND
INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY
TEST, HE SHALL UNCOVER HIS WORK AT HIS OWN EXPENSE.
PRECAUTIONS AND PROGRAMS DURING CONSTRUCTION.
AFTER IT HAS BEEN INSPECTED, TESTED AND APPROVED, THE
CONTRACTOR SHALL MAKE ALL REPAIRS NECESSARY TO THE
11.TU
ILITIES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR
OWNER'S SATISFACTION.
VERIFYING THE LOCATION OF ALL UNDERGROUND UTILITIES,
ELECTRICAL CABLES, CONDUITS, AND EXISTING IRRIGATION
4.
JOB SITE MEETINGS AND REQUIRED INSPECTIONS:
LINES PRIOR TO ANY CONSTRUCTION, SO THAT PROPER
PRECAUTIONS MAY BE TAKEN NOT TO DAMAGE SUCH
A. PRE -JOB MEETING ON SITE - PRIOR TO
IMPROVEMENTS.
COMMENCEMENT OF WORK
12.
LIABLE FOR DAMAGE: THE CONTRACTOR SHALL BE
B. IRRIGATION MAINLINE AND EQUIPMENT LAYOUT.
RESPONSIBLE FOR ANY DAMAGE CAUSED BY ITS OPERATIONS
TO UTILITIES, PLANTING, CONSTRUCTION, PERSONS,
C. PRESSURE TEST IRRIGATION, MAINS AND LATERALS
PROPERTY, ETC. AND SHALL PROVIDE PROTECTIVE MEANS TO
GUARD AGAINST DAMAGE.
D. IRRIGATION COMPLETION / COVERAGE TEST
13.
COORDINATION: CONTRACTOR SHALL COORDINATE ALL
UPON COMPLETION OF THE IRRIGATION SYSTEMINSTALLATION
CONSTRUCTION WITH APPROPRIATE TRADES THROUGH THE
AND PRIOR TO ANY PLANTING,
OWNER BEFORE STARTING WORK.
THE CONTRACTOR SHALL ADJUST SPRINKLER
HEADS TO EVENLY AND PROPERLY DISTRIBUTE
14.
IRRIGATION PLANS: THE IRRIGATION PLANS ARE GENERALLY
THE RATE OF PRECIPITATION OF THE WATER
AND SHALL DETERMINE IF THE COVERAGE OF THE
DIAGRAMMATIC AND INDICATIVE OF THE WORK TO BE
PLANTING AREAS IS COMPLETE AND ADEQUATE.
INSTALLED. THE CONTRACTOR SHALL MAKE MINOR
CONTRACTOR SHALL MAKE ADJUSTMENTS TO PROVIDE
ADJUSTMENTS DURING INSTALLATION TO AVOID CONFLICTS
OPTIMUM PERFORMANCE AND PREVENT UNNECESSARY
BETWEEN, PLANTING, ARCHITECTURAL FEATURES AND
OVER SPRAY ON ALL WALKS, ROADWAYS AND BUILDINGS.
EXISTING UTILITIES. INTENT OF IRRIGATION DESIGN IS FULL
THE CONTRACTOR SHALL FURNISH ALL MATERIALS AND
COVERAGE, BALANCED SYSTEM.
PERFORM ALL WORK REQUIRED TO CORRECT ANY
15.
DIMENSION: ALL SCALE DIMENSIONS ARE APPROXIMATE.
INADEQUACIES OF COVERAGE DISCLOSED BY THE
WRITTEN DIMENSIONS ON DETAILS AND PLANS TAKE
COVERAGE TEST.
PRECEDENCE OVER SCALED DIMENSIONS.
16.
IRRIGATION NOTES: SEE GENERAL NOTES ON THE DRAWINGS
C.
MATERIALS NOTES
FOR ADDITIONAL WORK REQUIRED, BUT NOT SPECIFICALLY
MENTIONED IN THESE SPECIFICATIONS. ALL WORK CALLED FOR
1.
GENERAL: THE FOLLOWING LIST COMPRISES THE PRINCIPLE
ON THE DRAWINGS BY NOTES SHALL BE FURNISHED AND
MATERIALS BUT DOES NOT SET THE LIMITATION FOR MATERIALS
INSTALLED WHETHER OR NOT SPECIFICALLY MENTIONED IN THE
REQUIRED. IT SHALL BE UP TO THE CONTRACTOR TO SHOW
SPECIFICATIONS AND/OR DETAILS.
THAT AMPLE QUANTITIES OF THE REQUIRED MATERIALS WERE
17.
POINT OF CONNECTION (P.O.C.) VERIFICATION: LOCATION
USED AND INSTALLED IN ACCORDANCE WITH THESE PLANS AND
OF THE POINT OF CONNECTION SHOWN ON THE DRAWINGS
SPECIFICATIONS.
MAYBE APPROXIMATE ONLY. THE CONTRACTOR SHALL
2.
PRESSURED MAINLINE: PIPE FROM SOURCE OF SUPPLY TO
APPROVE FINAL (P.O.C.) LOCATION WITH THE OWNER (JOB
CONTROL VALVES AND HOSE BIBS 2" OR LARGER SHALL BE
SUPERINTENDENT) THE CONTRACTOR SHALL VERIFY THE
CLASS 315 SDR 13.5 TYPE 1220 P.V.C. CONFORMING TO ASTM
STATIC PRESSURE, METER SIZE AND SIZE OF SERVICE TO THE
D2241, ASTM D1784 EXTRUDED FROM VIRGIN MATERIALS. ALL
METER (P.O.C.) AT EACH POINT OF CONNECTION.
PIPE LESS THAN 2" SHALL BE SCHEDULE 40 TYPE 1220 P.V.C.
18.
MATERIALS: ALL MATERIALS AND EQUIPMENT SPECIFIED IN
CONFORMING TO ASTM D1785, ASTM D1784 ALL PLASTIC PIPE
THESE DRAWINGS SHALL BE NEW AND IN PERFECT CONDITION
SHALL BE MARKED SHALL A EXTRUDED FROM VIRGIN
MATERIALS WITH THE MANUFACTURER'S NAME TYPE AND
WHERE INSTALLED AND SHALL BE INSTALLED IN ACCORDANCE
CLASS OF PIPE, SIZE AND NSF APPROVAL.
WITH THE MANUFACTURER'S SPECIFICATIONS.
19.
SUBSTITUTIONS: DESIGN, MATERIAL, EQUIPMENT AND
3.
LATERAL LINE BELOW GRADE: NON -PRESSURIZED LATERAL
PRODUCTS OTHER THAN THOSE DESCRIBED OR INDICATED ON
LINE PIPE SHALL BE CLASS 200 SDR 21 TYPE 1220 P.V.C.
CONFORMING TO ASTM D2 D1784. P.V.C. PIPING SHALL BE
DRAWINGS MAY BE CONSIDERED FOR USE. WRITTEN APPROVAL
EXTRUDED FROM VIRGIN MATERIALS. ALL PLASTIC PIPE SHALL
FOR SUBSTITUTIONS SHALL BE OBTAINED FROM THE OWNER
BE MARKED WITH THE MANUFACTURER'S NAME TYPE AND CLASS
AND LANDSCAPE ARCHITECT. ALL SUBSTITUTIONS SHALL
OF PIPE, SIZE AND NSF APPROVAL.
CONFORM TO LOCAL CODES AND ORDINANCES. ANY
EQUIPMENT OR MATERIALS INSTALLED WITHOUT APPROVAL BY
4.
LATERAL LINE ON GRADE: NON -PRESSURED LATERAL LINE
THE OWNER OR LANDSCAPE ARCHITECT MAY BE REJECTED AND
PIPE ON GRADE SHALL BE SCHEDULE 40 U.V.R. CONFORMING
REMOVED AT CONTRACTOR'S EXPENSE.
TO ASTM D1785, ASTM D1784 AND ASTM G-53. MANUFACTURED
20.
FITTING : DUE TO THE SCALE OF DRAWINGS, IT IS NOT
BY BROWNLINE PIPE COMPANY OR AS INDICATED ON LEGEND.
POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, SLEEVES, ETC.,
P.V.C. PIPING SHALL BE EXTRUDED FROM VIRGIN MATERIALS.ALL PLASTIC PIPE SHALL BE MARKED WITH THE
WHICH MAYBE REQUIRED. THE CONTRACTOR SHALL
MANUFACTURER'S NAME TYPE AND CLASS OF PIPE, SIZE AND
CAREFULLY INVESTIGATE THE STRUCTURAL AND FINISHED
NSF APPROVAL.
CONDITIONS AFFECTING ALL OF THE WORK AND PLAN THE
WORK ACCORDINGLY, FURNISHING SUCH FITTINGS, ETC.,
5.
PLASTIC PIPE FITTINGS: SHALL BE SCHEDULE 40 P.V.C.
AS MAY BE REQUIRED TO MEET SUCH CONDITIONS.
(CONFORMING TO ASTM D1785, D2466) TAPERED SOCKET TYPE,
21.
NOTICE OF COMPLETION: THE COMPLETION OF THE
SUITABLE FOR EITHER SOLVENT WELD OR SCREWED
CONTRACT SHALL BE ACCEPTED, AND NOTICE OF COMPLETION
CONNECTIONS, FLANGE AND SADDLE TEES WILL NOT BE
ALLOWED SOLVENT SHALL BE AS RECOMMENDED BY THE PIPE
RECORDED ONLY WHEN THE ENTIRE CONTRACT IS COMPLETED
AND FITTING MANUFACTURER.
TO THE SATISFACTION OF THE OWNER'S AUTHORIZED
REPRESENTATIVE.
6.
BRASS PIPE AND FITTINGS: BRASS PIPE SHALL BE RED BRASS,
22.
OPERATING INSTRUCTIONS: AFTER THE SYSTEM HAS BEEN
SCHEDULE 40 SCREWED PIPE CONFORMING TO FEDERAL
COMPLETED, THE CONTRACTOR SHALL INSTRUCT THE
SPECIFICATIONS NO. WW - P-351. FITTINGS SHALL BE RED
BRASS CONFORMING TO FEDERAL SPECIFICATION
OWNER'S AUTHORIZED REPRESENTATIVE IN THE OPERATION
N0. WW -P-460.
AND MAINTENANCE OF THE SYSTEM AND SHALL FURNISH A
COMPLETE SET OF OPERATING INSTRUCTIONS.
7,
COPPER PIPE AND FITTINGS: COPPER PIPE SHALL BE TYPE K
23.
SITE MAINTENANCE: CONTRACTOR SHALL KEEP THE PROJECT
(HARD -DRAWN) CONFORMING TO ASTM 688. FITTING SHALL BE
WROUGHT SOLDER JOINT TYPE IN ACCORDANCE WITH ANSI
SITE CLEAN AND FREE FROM RUBBISH AND DEBRIS. ALL DEBRIS
B JOINTS SHALL SOLDERED IN ACCORDANCE TO ASTM
SHALL BE REMOVED FROM SITE PER LOCAL CODE AND
B-206206 AND FEDERAL SPECIFICATIONS QQB 00655.
ORDINANCES.
REVISION DESCRIPTION
2ND CITY SUBMITTAL
3RD CITY SUBMITTAL
DATE ENGR. CITY
0.28.1
.13.17
DATE
SHOULD CONSTRUCTION OF REQVIgEO
IMPROVEMENTS NOT COMMENCE WITHIN
TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A
DILIGENT MANNER, THE CIN ENGINEER MAY
REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH
CONDITIONS AND STANDARDS IN EFFECT
PREPARED FOR:
STRATHAM HOMES, INC
2201 DUPONT DRIVE, SUITE 300
IRVINE, CA 92612
TEL (949) 833-1554
8. STEEL PIPE: GALVANIZED STEEL PIPE SHALL BE ASA SCHEDULE
40 MILLED STEEL SCREWED PIPE WITH MEDIUM GALVANIZED
SCREWED BEADED MALLEABLE IRON FITTINGS. STEEL PIPE
SHALL BE INSTALLED ON GRADE SECURED TO SURFACE PER
DETAIL.
9. BALL VALVES: SHALL BE BRONZE OR PLASTIC BODY AS
INDICATED ON DRAWINGS. 125 P.S.I. MINIMUM, HEAVY DUTY,
FEDERAL SPECIFIED, CROSS HANDLE. INSTALL WITH N.D.S. TYPE
PLASTIC OR EQUAL ACCESS BOX AND LID.
10. CONTROL VALVES: SHALL BE AS INDICATED ON THE
DRAWINGS WITH FLOW ADJUSTMENT AND MANUAL BLEED
DEVICE, INSTALLED, UNLESS OTHERWISE INDICATED, IN ONE
OF THE FOLLOWING TYPE BOXES AS INDICATED ON THE
DRAWINGS. CONNECT TO CONTROLLERS IN THE OPERATING
SEQUENCE INDICATED ON THE DRAWINGS.
11. CONTROL WIRE: CONNECTIONS BETWEEN THE AUTOMATIC
CONTROLLERS AND THE ELECTRONIC CONTROL VALVES SHALL
BE UF, SOLID COPPER WIRE, VINYL INSULATED 600 V. RATING,
FOR DIRECT BURIAL INSTALLATIONS. CODING SHALL BE
COLOR WIRE FOR PILOT WIRE. WHITE FOR COMMON GROUND
WIRE. MINIMUM WIRE SIZES SHALL BE 14 GAUGE BURIED 18"
BELOW GRADE. USE APPROVED WATER PROOF WIRE
CONNECTORS AND SEALER ON ALL SPLICES. A 24"
EXPANSION PIG TAIL COIL SHALL BE PROVIDED AT EACH
CONTROL VALVE AND AT EACH CHANGE IN DIRECTION OF THE
WIRE RUN. WIRING SHALL OCCUPY THE SAME TRENCH AND
SHALL BE INSTALLED ALONG THE SAME ROUTE AS PRESSURE
12. AUTOMATIC CONTROLLER: SHALL BE AS INDICATED ON
THE DRAWINGS, COMPLETE WITH ELECTRICAL HOOKUP AND
PROPER MOUNTING. ANY CONTROL WIRE EXPOSED AT THE
CONTROLLER SHALL BE ENCASED IN ELECTRICAL CONDUIT OF
THE SIZE REQUIRED. OUTDOOR CONTROLLERS SHALL BE
WITHIN A VANDAL RESISTANT ENCLOSURE AND EQUIPPED WITH
AN ON/OFF SWITCH FOR 110 VOLT POWER SUPPLY TO
CONTROLLER.
13. IRRIGATION HEADS: SHALL BE OF THE TYPES AND SIZES
INDICATED ON THE DRAWINGS. ALL HEADS SHALL BE
ADJUSTABLE, RISER NIPPLES SHALL BE THE SAME SIZE AS THE
RISER OPENING IN THE BODY.
14. BACKFLOW DEVICES: BACKFLOW PREVENTORS AND/OR
VACUUM BREAKERS SHALL BE AS INDICATED ON THE DRAWINGS
AND AS APPROVED BY AUTHORITIES HAVING JURISDICTION.
INSTALLED TO MEET LOCAL CODES. ALL IRRIGATION SYSTEMS
USING POTABLE WATER SOURCE REQUIRE BACKFLOW
PREVENTION.
15. CHECK VALVES: CONTRACTOR SHALL INSTALL ANTI -DRAIN
VALVES AS REQUIRED TO PREVENT LOW HEAD DRAINAGE. ANY
HEAD THAT DRAINS FOR MORE THAN ONE MINUTE REQUIRES AN
ANTI -DRAIN VALVE.
16. ATMOSPHERIC VACUUM BREAKERS: SHALL BE HEAVY DUTY
BRASS AND FEDERAL SPECIFIED. INSTALL ON NON -CONSTANT
PRESSURE LINES (LATERAL LINE) PER MANUFACTURE'S
SPECIFICATIONS. LOCATION PER DRAWINGS.
17. PRESSURE REGULATORS: SHALL BE BRONZE OR PLASTIC
BODY AS INDICATED ON DRAWINGS. FACTORY SET P.S.I. AS
SPECIFIED PER DRAWINGS.
18. QUICK COUPLERS: SHALL BE HEAVY DUTY BRASS WITH
COLORIZED RUBBER COVER AND TWO (2) PIECE BODY
DESIGN. LOCATION PER DRAWINGS.
19. RISERS: ALL RISERS TO QUICK COUPLERS AND BACK FLOW
DEVICES SHALL BE SCHEDULE 40 BRASS OF THE REQURED
SIZES, RISERS TO IRRIGATION HEADS SHALL BE SCHEDULE 80
TYPE 1220 P.V.C. CONFORMING TO ASTM 2464.
20. VALVE BOXES: INSTALL ALL VALVES, EXCEPT ANTI -SIPHON
VALVES, IN PREMOLDED HIGH IMPACT PLASTIC VALVE BOX. USE
ROUND BOX FOR QUICK COUPLERS AND RECTANGULAR BOX
FOR ALL OTHER VALVES. N.D.S (OR APPROVED EQUAL) WITH
GREEN LID. LOCATE IN SHRUB PLANTING AREAS WHENEVER
POSSIBLE.
D. PLASTIC PIPE NOTES
1. HANDLING: THE CONTRACTOR SHALL EXERCISE CARE IN
HANDLING, LOADING AND STORING P.V.C. PIPE AND FITTINGS.
ALL P.V.C. PIPE SHALL LIE FLAT SO NOT TO SUBJECT IT TO
NDUE BENDING OF CONCENTRATED EXTERNAL LOAD AT ANY
POINT. P.V.C. PIPE AND FITTINGS SHALL NOT BE STORED IN
DIRECT SUNLIGHT. ANY SECTION OF PIPE THAT HAS BEEN
DENTED OR DAMAGED WILL BE DISCARDED.
2. LOCATIONS: PIPE LINES SHALL BE INSTALLED IN THE
LOCATIONS AND OF THE SIZES SHOWN ON THE DRAWINGS OR
HEREIN SPECIFIED. WHERE PIPING ON THE DRAWINGS IS
SHOWN UNDER PAVED AREAS BUT RUNNING PARALLEL AND
ADJACENT TO PLANTING AREAS, THE INTENT OF THE DRAWINGS
IS TO INSTALL THE PIPING IN THE PLANTING AREA.
3. PIPE CLEARANCE: UNDERGROUND LINES UP TO 2" INCLUSIVE
SHALL HAVE A MINIMUM HORIZONTAL CLEARANCE OF 12" FROM
LINES OF OTHER TRADES. THIS REQUIREMENT DOES NOT
APPLY TO ANY LINES CROSSING AT ANGLES FROM 45'
WITH EACH OTHER. A MINIMUM 2" VERTICAL CLEARANCE SHALL
BE MAINTAINED BETWEEN LINES WHICH CROSS BETWEEN
THESE ANGLES. NO LINE SHALL BE INSTALLED PARALLEL TO
AND DIRECTLY OVER ANOTHER LINE.
4. ASSEMBLY: ALL PIPE SHALL BE ASSEMBLED FREE FROM DIRT.
THE MAIN LINE SUPPLY SHALL BE FLUSHED OUT AND TESTED
FOR LEAKS BEFORE BACK FILLING AND WITH CONTROL VALVES
IN PLACE AND BEFORE LATERAL PIPES ARE CONNECTED TO
VALVES. EACH SECTION OF LATERAL PIPE SHALL BE FLUSHED
OUT BEFORE SPRINKLER HEADS ARE ATTACHED,
5. UNDER CONCRETE: GENERALLY, PIPING UNDER CONCRETE
SHALL BE DONE BY JACKING, BORING OR HYDRAULIC
DRIVING. WRITTEN PERMISSION TO CUT OR BREAK SIDEWALKS
AND/OR CONCRETE MUST BE OBTAINED FROM THE OWNER'S
AUTHORIZED REPRESENTATIVE. NO HYDRAULIC RIVING WILL
BE PERMITTED UNDER ASPHALTIC CONCRETE PAVING.
6. INSTALLATION PROCEDURES: EXCEPT AS NOTED IN OTHER
PARTS OF THIS SPECIFICATION OR IN THE DRAWINGS,
INSTALLATION OF PIPE AND FITTINGS SHALL BE AS OUTLINE IN
MANUALS AS FURNISHED BY PIPE MANUFACTURER WHICH SHALL
BE DEEMED AND CONSTRUED AS PART OF THIS SPECIFICATION.
PLASTIC PIPE SHALL NOT BE LAID WHEN THERE IS WATER IN
TRENCH.
7. PIPE DEPTH: PROVIDE A MINIMUM 24" OF EARTH COVERAGE
FOR ALL PRESSURE MAINLINE PIPE 3" AND LARGER. PROVIDE A
MINIMUM 18" OF EARTH COVERAGE FOR ALL PRESSURE
MAINLINE PIPE UP TO AND INCLUDING 2 1/2 PROVIDE A MINIMUM
OF 12" OF EARTH COVERAGE FOR ALL NON PRESSURE LATERAL
LINES.
8. SITE MAINTENANCE: ALL LUMBER, RUBBISH AND LARGE
ROCKS SHALL BE REMOVED FROM THE TRENCHES. PIPE SHALL
HAVE A FIRM, UNIFORM BEARING FOR THE ENTIRE LENGTH OF
EACH PIPE LINE TO PREVENT UNEVEN SETTLEMENT. PAD THE
TRENCHES WITH DIRT OR SAND IF THE SOIL IS EXTREMELY
ROCKY.
9. TREE LOCATIONS: TREE LOCATIONS TAKE PRIORITY OVER
IRRIGATION PIPING. STAKE TREE LOCATIONS PRIOR TO
TRENCHING PIPE.
10. EXPANSION: PLASTIC PIPE WILL EXPAND APPROXIMATELY SIX IN.
(6") PER THOUSAND FT. (1000') BETWEEN DAY AND NIGHT
TEMPERATURES IN HOT CLIMATE. THEREFORE, PIPE SHALL BE
SNAKED FROM SIDE TO SIDE OF TRENCH BOTTOM TO ALLOW
FOR EXPANSION AND CONTRACTION.
I
11. PIPE MAINTENANCE: ALL FOREIGN MATTER OR DIRT SHALL BE
REMOVED FROM THE INSIDE OF THE PIPE BEFORE IT IS
LOWERED INTO POSITION IN THE TRENCH AND IT SHALL BE
KEPT CLEAN BY APPROVED MEANSi DURING AND AFTER LAYING
OF THE PIPE.
12. SLEEVING: IRRIGATION LINES THAT ARE UNDER STREETS AND
PAVING OVER SEVEN (7) FEET WIDE SHALL BE INSTALLED BY THE
OWNER. SLEEVES UNDER PAVING AND STREETS SHALL BE
SCHEDULE 40 AND TWO TIMES THE DIAMETER OF THE PIPE AND/
OR ADEQUATE FOR INSTALLATION OF WIRE. SLEEVING SHALL
BE COORDINATED WITH IRRIGATION CONTRACTOR PRIOR TO
BEGINNING OF WORK.
13. JOINT : JOINTS ON RISERS SHALL BE AS SHOWN ON DETAILS.
I
14. THREADED CONNECTIONS: ON PLASTIC TO STEEL
CONNECTIONS, THE CONTRACTOR SHALL WORK THE STEEL
CONNECTIONS FIRST. NON -HARDENING PIPE PERMATEX #2
TEFLON TAPE SHALL BE USED ON 'ALL THREADED PLASTIC TO
STEEL JOINTS, AND LIGHT WRENCH PRESSURE IS ALL THAT
SHALL BE USED, I
15. SOLVENT CONNECTIONS: FOR P.V.C. PIPE CONTRACTOR
SHALL USE SOLVENT PRIMER AND .SOLVENT CEMENT
RECOMMENDED BY THE MANUFACTURER AND CONFORMING TO
ASTM D-2564. FOR UVR-P.V.C. SOLVENT CEMENT SHALL BE
BROWNLINE BOND -TITS CEMENT (CONFORMING TO THE
REQUIREMENTS OF ASTM D-2564) APPLY WITH AN APPROVED
PRIMER PRIOR TO APPLICATION OF: CEMENT. ALL PIPE AND
FITTINGS SHALL BE THOROUGHLY CLEANED OF DIRT, DUST AND
MOISTURE BEFORE APPLYING SOLVENT. THE CONTRACTOR
WILL MAKE SOLVENT WELD JOINTS.WITH NON -SYNTHETIC
BRISTLE BRUSH IN THE FOLLOWING SEQUENCE:
A. APPLY A LIBERAL, EVEN COAT OF,SOLVENT TO THE
INSIDE OF THE FITTING. I
B. THEN APPLY A LIBERAL, EVEN COAT OF SOLVENT TO THE
OUTSIDE OF THE PIPE, MAKING SURE THAT THE COATED
AREA IS EQUAL TO THE DEPTH OF THE FITTING SOCKET.
C. INSERT THE PIPE QUICKLY INTO THE FITTING AND TURN
THE PIPE APPROXIMATELY 1/4 TURN TO DISTRIBUTE THE
SOLVENT AND REMOVE AIR BUBBLES. HOLD THE JOINT
FOR APPROXIMATELY 15 SECONDS SO THE FITTING DOES
NOT PUSH OFF THE PIPE.
D. USE A CLEAN RAG AND WIPE OFF ALL EXCESS SOLVENT
TO PREVENT WEAKENING THE JOINT.
E. BE SURE THAT IN GOING TO THE NEXT JOINT THAT THE
PIPE IS NOT TWISTED, DISTURBING THE LAST
COMPLETED JOINT.
F. ALLOW AT LEAST 15 MINUTES SET UP TIME FOR EACH.
I
16. PRESSURE LINE TESTING: ALL TESTS ON PRESSURE LINES
SHALL BE COMPLETE PRIOR TO BACKFILLING; HOWEVER,
SUFFICIENT BACKFILL MATERIAL MAY BE PLACED IN TRENCHES
BETWEEN FITTINGS TO ENSURE THE STABILITY OF THE LINE
PRESSURE. IN ALL CASES, FITTINGS AND COUPLINGS MUST BE
OPEN TO VISUAL INSPECTION FOR THE FULL PERIOD OF THE
TEST. NO TESTING SHALL BE DONE UNTIL THE LAST SOLVENT
WELDED JOINT HAS HAD TWELVE (12) HOURS TO SET AND
CURE. PRESSURE LINES SHALL BE TESTED UNDER 150 P.S.I.
WORKING PRESSURE FOR A PERIOD OF FOUR (4) HOURS AND
PROVEN TIGHT. IF LEAKS OCCUR, THE JOINT OR JOINTS SHALL
BE REPLACED AND THE TESTS REPEATED.
17. BACKFILLING OF TRENCHES: BECAUSE OF THE EXPANSION
AND CONTRACTION OF PLASTIC PIPE, BACKFILLING SHALL BE
DONE IN THE COOL PART OF THE DAY, ESPECIALLY IN HOT
CLIMATES. TRENCHES SHALL BE BACKFILLED WITH THE
EXCAVATED MATERIALS APPROVED FOR BACKFILLING, FREE
FROM LARGE CLODS OF EARTH OR STONES. BACKFILL SHALL
BE MECHANICALLY COMPACTED IN THE LANDSCAPED AREAS TO
A DRY DENSITY EQUAL TO ADJACENT UNDISTURBED SOIL IN
PLANTING AREAS. BACKFILL WILL CONFORM TO ADJACENT
GRADES WITHOUT DIPS, SUNKEN AREAS, HUMPS OR OTHER
SURFACE IRREGULARITIES.
18. TRENCHING AND BACKFILLING UNDER PAVING: TRENCHES
LOCATED UNDER WHERE PAVING, CONCRETE OR ASPHALT WILL
BE INSTALLED SHALL BE BACKFILLED IN ACCORDANCE WITH
RECOMMENDATION OF STRUCTURAL SOILS REPORT.
19. PLASTIC PIPE GUARANTEE: SPECIFICATIONS AND LITERATURE
SHALL BE SUBMITTED FOR APPROVAL PRIOR TO SUBMISSION
OF BID. SUBMISSION OF SAMPLES MAY ALSO BE REQUIRED.
PLASTIC PIPE MANUFACTURER'S GUARANTEE SHALL COVER
WORKMANSHIP OF MATERIALS FOR ALL PLASTIC PIPE FITTINGS.
20.ED FECTS: ALL DEFECTS IN INSTALLATION OF PLASTIC PIPE
SHALL BE CORRECTED THROUGH THE GUARANTEE PERIOD
SPECIFIED HEREIN AT THE CONTRACTOR'S EXPENSE TO THE
SATISFACTION OF THE OWNER.
I
E. IRRIGATION EQUIPMENT NOTES
1. IRRIGATION EQUIPMENT: ALL IRRIGATION EQUIPMENT SHALL
BE INSTALLED PER THE SPECIFICATION AND RECOMMENDED
INSTALLATION PROCEDURES OF THE MANUFACTURER AND
CONFORM TO ALL APPLICABLE GOVERNING CODES AND
ORDINANCES (LOCAL., COUNTY & STATE).
1
2. TURF IRRIGATION HEADS: TURF IRRIGATION HEADS IN OPEN
AREAS SHALL BE INSTALLED AT LEAST 2" ABOVE FINISHED
GRADE AT THE TIME OF INSTALLATION. WITHIN FIVE DAYS OF
NOTIFICATION BY THE OWNER'S REPRESENTATIVE,
CONTRACTOR SHALL MAKE WHATEVER ADJUSTMENTS OF PIPE,
FITTINGS, VALVES OR SPRINKLER HEADS NECESSARY TO BRING
THE SYSTEM TO THE PROPER LEVEL OF THE PERMANENT
GRADE. TURF IRRIGATION HEADS ALONG WALKS AND
DRIVEWAYS, WHERE THE FINISHED GRADE LEVEL IS
ESTABLISHED, SHALL BE SET FLUSH AT THE TIME OF
INSTALLATION. IN NO CASE SHALL THE SPACING OF HEADS
EXCEED THE MAXIMUM RECOMMENDED BY THE MANUFACTURER.
3. SHRUB IRRIGATION HEADS: HEADS IN GROUND COVER AND
PLANTING AREAS SHALL BE INSTALLED ON NIPPLES HIGH
ENOUGH TO BE ABOVE THE SURROUNDING PLANTING AS
DIRECTED, OR AS INDICATED ON THE PLANS. WHERE HIGH
SHRUBS ARE PLANTED, LONGER RISERS SHALL BE INSTALLED
AS DIRECTED BY THE LANDSCAPE ARCHITECT. SHRUB HEADS
ADJACENT TO WALKWAYS OR PARKING SHALL BE INSTALLED ON
AN APPROVED HI -POP HEAD PER PLAN. RISERS SHALL BE
LOCATED AS SPECIFIED PER PLANS ADJACENT TO WALLS AND
BUILDINGS ONLY. IN NO CASE SHALL THE SPACING OF HEADS
EXCEED THE MAXIMUM RECOMMENDED BY THE MANUFACTURER.
4. PRESSURE COMPENSATING SCREENS: CONTRACTOR SHALL
INSTALL PRESSURE COMPENSATING SCREENS IN IRRIGATION
HEADS AS NECESSARY TO ENSURE UNIFORM COVERAGE AND
MINIMUM OVERTHROW OF AREA. I
5. CONTROL VALVES: ALL CONTROL VALVES ON LINE SHALL BE
INSTALLED AS INDICATED ON DETAILS AND BE THE TYPE
SPECIFIED IN THE LEGEND. LOCATE CONTROL VALVES IN
SHRUB PLANTING AREAS WHEREVER POSSIBLE.
6. BACKFLOW DEVICES: LOCATE BACKFLOW DEVICES,
- ATMOSPHERIC VACUUM BREAKERS AND ANTI -SIPHON VALVES
IN SHRUB AREAS ONLY UNLESS OTHERWISE APPROVED BY
OWNER. ii
L A N D S C A P E
ARCHITECTURE
Prepared ;By:
507 30th St.
Newport Beach, CA 92663
9491675.9964
mjs-la.com
7. DEFECTS: ALL DEFECTS IN INSTALLATION OF IRRIGATION
EQUIPMENT SHALL BE CORRECTED THROUGH THE GUARANTEE
PERIOD SPECIFIED HEREIN AT THE CONTRACTOR'S EXPENSE TO
THE SATISFACTION OF THE OWNER.
F. RECORD AND AS -BUILT DRAWINGS
1. ITEMIZED LIST, CONTRACTOR SHALL SUBMIT TO THE
LANDSCAPE ARCHITECT AN ITEMIZED UST OF EQUIPMENT.
2. AS-BUILTS: THE CONTRACTOR SHALL PROVIDE AND KEEP UP -
TO DATE COMPLETE "AS -BUILT" DRAWINGS INDICATING
LOCATIONS, SIZES AND KINDS OF EQUIPMENT INSTALLED.
PRINTS FOR THIS PURPOSE MAY BE OBTAINED FROM THE
LANDSCAPE ARCHITECT AT COST. THIS SET OF DRAWINGS
SHALL BE KEPT ON THE SITE AND SHALL BE USED ONLY AS A
RECORD SET. CONTRACTOR SHALL FURNISH "AS -BUILT"
DRAWINGS TO OWNER UPON COMPLETION OF PROJECT.
3. AS -BUILT FORMAT
SUBMITTAL OF AS -BUILT PLANS SHALL BE AS REQUIRED BY THE
ENGINEERING AND PLANNING DEPARTMENTS. THE FINAL PLANS
SHOULD BE PREPARED BY THE LANDSCAPE ARCHITECT FROM
DIMENSIONS PROVIDED BY THE LANDSCAPE CONTRACTOR. FINAL
AS -BUILT PLANS SHALL BE DRAFTED CLEARLY TO THE SATISFACTION
OF THE CITY, AND THE ORIGINAL MYLARS SHALL BE SUBMITTED TO
THE CITY FOR THEIR KEEPING. FINAL AS -BUILT PLANS WILL BE
REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND FINAL
MYLARS WILL BE REQUIRED TO BE APPROVED AND SIGNED BY THE
CITY PRIOR TO PLANNING DEPARTMENT SIGNING THE PERMIT CARD.
CONTRACTOR TO PROVIDE THE FOLLOWING TO LANDSCAPE ARCHITECT:
A. CONNECTION TO EXISTING WATER LINES.
B. CONNECTION TO EXISTING ELECTRICAL POWER.
C. GATE VALVES, BACKFLOW PREVENTION
UNITS AND CONTROLLERS.
D. ROUTING OF IRRIGATION PRESSURE LINES
(DIMENSION MAX. 100').
E. IRRIGATION CONTROL VALVES.
F. ROUTING OF CONTROL WIRE.
4. G. QUICK COUPLING VALVES.
H. OTHER RELATED EQUIPMENT AS DIRECTED
BY OWNER.
a
CONTROLLER CHARTS: CONTROLLER CHARTS
SHALL BE PREPARED BY THE CONTRACTOR AFTER
APPROVAL OF THE "AS -BUILT". THE CHART SHALL
SHOW BY COLOR CODING THE AREA CONTROLLED BY
EACH AUTOMATIC IRRIGATION CONTROLLER.
CONTROLLER CHART FORMAT: THE CONTROLLER
CHART SHALL BE A XEROX REDUCTION OF THE
"AS BUILT" TO THE MAXIMUM SIZE OF THE CONTROLLER
DOOR WILL ALLOW (CONTROLLER SEQUENCE
NUMBERS MUST BE LARGE ENOUGH TO BE LEGIBLE
AT THE REDUCED FORMAT). UPON COMPLETION THE
CHART SHALL BE HERMETICALLY SEALED BETWEEN
TWO PIECES OF PLASTIC. CHARTS SHALL BE
COMPLETED AND APPROVED PRIOR TO THE FINAL
IRRIGATION FIELD OBSERVATION
G. EQUIPMENT TO BE FURNISHED
1. MAINTENANCE
TOOLS: SUPPLY THE APPROPRIATE
MAINTENANCE
PERSONNEL WITH THE FOLLOWING TOOLS:
A.
TWO SETS OF SPECIAL TOOLS REQUIRED FOR
REMOVING, DISASSEMBLING AND ADJUSTING EACH
TYPE OF IRRIGATION HEAD AND VALVE SUPPLIED.
B.
TWO (2) KEYS FOR EACH AUTOMATIC
CONTROLLER.
C.
ONE (1) QUICK COUPLER KEY AND MATCHING
HOSE SWIVEL FOR EVERY (5) QUICK COUPLING
VALVE INSTALLED.
D.
THE ABOVE LISTED EQUIPMENT SHALL BE TURNED
OVER TO THE OWNER AT THE CONCLUSION OF
WORK AND BEFORE FINAL OBSERVATION CAN
OCCUR.
H. HOMEOWNERS ASSOCIATION (H.O.A.)
RESPONSIBILITY
1 AS-BUILTS: THE CONTRACTOR SHALL PROVIDE
THE H.O.A. ONE (1) SET OF COMPLETE "AS
BUILT" INFORMATION ON AN OZALIO SEPIA MYLAR
PRODUCED FROM THE LANDSCAPE ARCHITECT.
2. (MAINTENANCE PROGRAM: THE CONTRACTOR
SHALL PROVIDE THE H.O.A. ONE (1) SET OF
MAINTENANCE GUIDLINES AS RECOMMENDED BY
THE MANUFACTURER/SUPPLIER.
0 10' 20' 40'
SCALE: III
= 20' NORTH
CITY OF FONTANA, CALIFORNIA
SUMMIT AVENUE MEDIAN WEST C.D. PLANS
DRAWN BY. BJ SCALE.
1"=20'
DESIGNED BY. BJ IRRIGATION SPECIFICATIONS DATE.
- JANUARY 13, 2017
CHECKED BY: MJ APPROVED BY:
DATE. 5564
6
CITY ENGINEER R.C.E. 51152 , 0