Loading...
HomeMy WebLinkAbout5583-8M CL v IRRIGATION SPECIFICATIONS I. SCOPE OF WORK (1) VALVES: 3) AUTOMATIC CONTROLLER INSTALLATION. 3 GATE VALVES. K VERIFICATION OF FINISH GRADE - THE C JOINING OF PIPE - THE CONTRACTOR IS 4) CONTROLLER WIRE INSTALLATION. 4) ROUTING OF SPRINKLER PRESSURE LINES - THE WORK INCLUDED IN THESE SPECIFICATIONS O ( ) 1) PIPING SYSTEMS -SHALL BE SUPPLIED WITH DIMENSION MAX. 100' ALONG ROUTING). SHALL CONSIST OF THE FURNISHING OF ALL CONTRACTOR SHALL VERIFY THE RESPONSIBLE TO BE FAMILIAR WITH ANY AND 5 LATERAL LINE AND SPRINKLER 5 SPRINKLER -CONTROL VALVES. CORRECTNESS OF ALL FINISH GRADES WITHIN VALVES AT ALL POINTS SHOWN ON THE ) LABOR, TOOLS, MACHINERY, MATERIALS, ALL. METHODS OF ASSEMBLING, JOINING AND INSTALLATION. ) THE WORK AREA IN ORDER TO INSURE THE DRAWINGS OR SPECIFIED HEREIN, 6 COVERAGE TEST AND MAINTENANCE APPLIANCES, AND PROCESSES REQUIRED FOR THE INSTALLATION OF .THE VARIOUS TYPES OF 6) ROUTING OF CONTROL WIRING. PROPER SOIL COVERAGE (AS SPECIFIED) OF ARRANGED TO GIVE COMPLETE ) INSTALLATION OF A. COMPLETE LANDSCAPE PIPE TO BE USED. HE WILL ADHERE IN REGULATING CONTROL THROUGHOUT. PERIOD. IRRIGATION SYSTEM HEREIN SPECIFIED AND SHOWN THE SPRINKLER SYSTEM PIPES. STRICT ACCORDANCE WITH MANUFACTURER'S 7) FINAL INSPECTION AND ACCEPTANCE. (E) ON OR BEFORE THE DATE OF THE FINAL ON THE ACCOMPANYING DRAWING(S). III. SUBMITTALS - RECOMMENDED GUIDE. IF DURING ANY PHASE 2) VALVES SHALL BE THE FULL SIZE OF THE BY THE CITY INSPECTOR. INSPECTION, THE CONTRACTOR SHALL OF THE WORK THE OWNER'S REPRESENTATIVE LINE IN WHICH THEY ARE INSTALLED DELIVER THE CORRECTED AND COMPLETED II. GENERAL REQUIREMENTS (A) MATERIAL LIST: (0) COMPLETION - THE WORK WILL BE ACCEPTED MYLARS TO THE CSA. INSPECTOR. DELIVERY FINDS THAT THE CONTRACTOR OR ANY OF UNLESS OTHERWISE INDICATED. (A) INTENT—THE INTENT OF THE DRAWINGS AND 1) THE CONTRACTOR SHALL FURNISH THE HIS WORKMEN ARE NOT FAMILIAR WITH THE IN WRITING WHEN THE WHOLE CONTRACT OF THE MYLARS WILL NOT RELIEVE THE SPECIFICATIONS IS TO INDICATE AND SPECIFY ARTICLES, EQUIPMENT, MATERIALS OR RECOMMENDED PROCEDURES, THE 3) CONTROL VALVES SHALL BE ADJUSTED SO SHALL HAVE BEEN COMPLETED CONTRACTOR OF THE RESPONSIBILITY OF A COMPLETE AND EFFICIENT IRRIGATION SYSTEM. PROCESSES SPECIFIED BY NAME IN THE CONTRACTOR SHALL ARRANGE WITH THE MOST REMOTE SPRINKLER HEADS SATISFACTORILY TO THE CITY INSPECTOR. FURNISHING REQUIRED INFORMATION THAT ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. NO MANUFACTURER OF THE PARTICULAR OPERATE AT THE PRESSURE RECOMMENDED IN JUDGING THE WORK, NO ALLOWANCE FOR MAY BE OMITTED FROM THE PRINTS. THE CITY OF RIVERSIDE CSA 143 LANDSCAPE SUBSTITUTION WILL BE ALLOWED WITHOUT PRODUCT FOR THE SERVICES OF A QUALIFIED BY THE HEAD MANUFACTURER. CONTROL DEVIATION FROM THE ORIGINAL PLANS AND SPECIFICATIONS AND STANDARDS BOOKLET, ANDPRIOR WRITTEN APPROVAL BY THE CSA MANUFACTURER'S REPRESENTATIVE TO VALVES SHALL BE ADJUSTED SOA SPECIFICATIONS WILL BE MADE UNLESS(F) CONTROLLER CHARTS: MEETING THE APPROVAL OF THE CITY INSPECTOR REPRESENTATIVE. INSTRUCT WORKMEN IN THE PROPER UNIFORM DISTRIBUTION OF WATER IS ALREADY APPROVED IN WRITING AT PROPER ( ) SHALL BE COMPLETED WITHOUT FURTHER COST OF 1) AS -BUILT DRAWINGS SHALL BE PREPARED LABOR AND MATERIAL TO THE DEVELOPER/OWNER. 2) COMPLETE MATERIAL LIST SHALL BE RECOMMENDED PROCEDURES. APPLIED BY THERSPRI SPRINKLER H H DS TO TIMES. BY THE LANDSCAPE CONTRACTOR BEFORE TA SUBMITTED PRIOR TO PERFORMING ANY E PLANTING EAS 0REAC SHOULD IT BECOME NECESSARY, DUE TO (B) VERIFICATION OF DIMENSIONS - ALL PLOT WORK. MATERIAL LIST SHALL INCLUDE INDIVIDUAL VALVE SYSTEM. DEVELOPED CONDITIONS, TO OCCUPY ANY CONTROLLER CHARTS ARE PREPARED. DIMENSIONS ARE APPROXIMATE. BEFORE (D) FLUSHING OF SYSTEM: THE MANUFACTURER, MODEL NUMBER AND POSITION OF THE WORK BEFORE THE 2) TWO (2) SETS OF COLOR CODED PROCEEDING WITH ANY WORK, THE DESCRIPTION OF ALL MATERIALS AND 4) QUICK COUPLING VALVES SO INDICATED CONTRACTOR SHALL CAREFULLY CHECK AND EQUIPMENT T U ED. 1) AFTER ALL NEW SPRINKLER PIPE LINES CONTRACT IS FULLY COMPLETED, SUCH IRRIGATION CHARTS INDICATING ZONES TO s TO BE INSTALLED ADJACENT TO WALKS, VERIFY ALL DIMENSIONS AND SHALL REPORT AND RISERS ARE IN PLACE AND OCCUPANCY SHALL NOT CONSTITUTE OF COVERAGE FOR EACH STATION WILL BE. ANY VARIATIONS TO THE LANDSCAPE ARCHITECT. 3) EQUIPMENT OR MATERIALS INSTALLED THAT CONNECTED, CURBS ETC. SHALL BE WITHIN A ACCEPTANCE. REQUIRED FOR EACH CONTROLLER(S). ALL NECESSARY DIVERSION TWELVE 12 � INCH MAXIMUM OF SAME. O�. P - T THE ARE NOT PER THE APPROVED PLANS SHALL WORK HAS BEEN COMPLETED, AND PRIOR C ) (P) INSTRUCTION - AFTER THE SYSTEM HAS BEEN CHARTS WILL BE SEALED IN 10 MIL (C) EXPLANATION OF DRAWINGS DUE 0 MAY BE REJECTED BY THE LANDSCAPE ARCHITECT TO INSTALLATION OF SPRINKLER HEADS, ALL QUICK COUPLING VALVES SHALL BE COMPLETED, THE CONTRACTOR SHALL SCALE OF DRAWINGS, IT IS NOT POSSIBLE TO AND THE CONTRACTOR REQUIRED TO THE CONTROL VALVES SHALL BE OPENED INSTALLED BELOW GRADE IN ROUND INSTRUCT THE CITY INSPECTOR IN THE INDICATE ALL OFFSETS, FITTINGS, SLEEVES, ETC. REMOVE SUCH MATERIALS FROM THE SITE AND A FULL HEAD OF WATER USED TO OPERATION AND MAINTENANCE OF THE AT HIS OWN EXPENSE. PLASTIC VALVE BOX PER DETAIL WITH WHICH MAY BE REQUIRED. THE CONTRACTOR ( � VI. OPERATION AND MAINTENANCE MANUALS SHALL CAREFULLY INVESTIGATE THE STRUCTURAL FLUSH OUT THE SYSTEM. LOCKING COVER. SYSTEM AND SHALL FURNISH A COMPLETE SET A PREPARE AND DELIVER TO THE CSA. AND FINISHED CONDITIONS AFFECTING ALL OF 4) . APPROVAL OF ANY ITEM, ALTERNATE" OR OF OPERATING INSTRUCTIONS. O 2) SPRINKLER HEADS SHALL BE INSTALLED (J) VALVE BOXES: REPRESENTATIVE WITHIN TEN CALENDAR DAYS HIS WORK AND PLAN HIS WORK ACCORDINGLY, SUBSTITUTE INDICATES ONLY THAT THE ONLY AFTER FLUSHING OF THE SYSTEM (Q) GENERAL INSTALLATION -ANY EQUIPMENT PRIOR TO COMPLETION OF CONSTRUCTION, FURNISHING SUCH FITTINGS, `ETC. AS MAY BE PRODUCT OR PRODUCTS APPARENTLY 1) PLASTIC .VALVE BOXES (AMATEK OR REQUIRED TO TO MEET SUCH CONDITIONS. MEET THE REQUIREMENTS OF THE HAS BEEN ACCOMPLISHED TO THE INSTALLED BY THE CONTRACTOR AND DEEMED TWO HARD COVER BINDERS WITH THREE Q APPROVED EQUAL) "SHALL BE INSTALLED DRAWINGS ARE GENERALLY DIAGRAMMATIC AND DRAWINGS AND SPECIFICATIONS ON THE COMPLETE SATISFACTION OF THE TWO 2 INCHES ABOVE FINISH GRADE. - TO BE FOR THE USE OF THE CITY IN VARIOUS RINGS CONTAINING THE FOLLOWING INDICATIVE OF THE WORK TO BE INSTALLED. BASIS OF THE INFORMATION OR SAMPLES CITY INSPECTOR. ONLY ONE I (1) REMOTE CONTROL VALVE SITUATIONS (I.E., GATE VALVES, CONTROL INFORMATION: THE WORK SHALL BE INSTALLED IN SUCH A SUBMITTED. VALVES, ETC.) SHALL BE SO INSTALLED TO . MANNER AS TO AVOID CONFLICTS BETWEEN (E) PRESSURE TEST: MAY BE INSTALLED IN EACH BOX. - BE READILY ACCESSIBLE AND QUICKLY 1) INDEX SHEET STATING CONTRACTOR'S IRRIGATION. SYSTEMS PLANTING AND ARCHITECTURAL 5)_ MANUFACTURERS WARRANTIES SHALL NOT 2 VALVE BOXES LOCATED NEAR WALKS OPERABLE BY THE CITY. EQUIPMENT DEEMED ADDRESS AND TELEPHONE NUMBER, A FEATURES. RELIEVE THE CONTRACTOR OF HIS 1) ALL PRESSURE LINES SHALL BE TESTED ) Q LIST OF EQUIPMENT WITH NAMES AND LIABILITY UNDER THE GUARANTEE. SUCH UNDER HYDROSTATIC PRESSURE OF 160 CURBS AND PAVING SHALL BE INSTALLED BY THE CITY INSPECTOR TO BE INOPERABLE ADDRESSES OF LOCAL MANUFACTURER'S IN SUCH A WAY AS TO ALLOW FOR VALVE FOR ITS INTENDED PURPOSE SHALL BE 1) ALL WORK CALLED FOR ON THE DRAWINGS WARRANTIES SHALL ONLY SUPPLEMENT POUNDS PER SQUARE INCH, AND ALL REPRESENTATIVES. BY NOTES OR DETAILS SHALL BE THE GUARANTEE. NON -PRESSURE LINES SHALL BE TESTED BOXES TO ABUT THOSE ITEMS WITH TOP REINSTALLED BY THE CONTRACTOR IN AN FURNISHED AND INSTALLED WHETHER OR IV. INSTALLATIONUNDER THE EXISTING STATIC PRESSURE SURFACE MATCHING PLANE AS ITEMS OPERABLE POSITION BEFORE APPROVAL WILL 2) CATALOG AND PARTS SHEETS ON EVERY NOT SPECIFICALLY MENTIONED IN THE LISTED ABOVE. BE GIVEN. MATERIAL AND EQUIPMENT INSTALLED SPECIFICATIONS.. (A) STANDARD OF INSTALLATION -MATERIAL AND BOTH BE PROVEN WATERTIGHT. - AND WORKMANSHIP SHALL BE IN ACCORDANCE CONTRACTOR SHALL PROVIDE ALL 3) ALL VALVE BOXES WILL BE MARKED WITH (R) CLEAN-UP - CLEAN-UP SHALL BE MADE AS UNDER THIS CONTRACT. - (D) SITE CONDITIONS — THE CONTRACTOR SHALL WITH LOCAL CODES AND ORDINANCES OF EQUIPMENT FOR HYDROSTATIC TESTS. TWO INCH (2") HIGH BRANDED LETTERS EACH PORTION OF WORK PROGRESSES. 3) GUARANTEE STATEMENT. NOT WILLFULLY INSTALL THE IRRIGATION LEGALLY CONSTITUTED AUTHORITIES, EXCEPT INDICATING THE STATION NUMBER. REFUSE AND EXCESS. DIRT SHALL BE REMOVED 4) COMPLETE OPERATING AND MAINTENANCE SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT WHERE PROVISIONS OF THESE SPECIFICATIONS NOTE: TESTING OF PRESSURE SUPPLY FROM THE SITE, ALL WALKS AND PAVING INSTRUCTION ON ALL MAJOR EQUIPMENT. IS OBVIOUS IN THE FIELD THAT UNKNOWN EXCEED SUCH REQUIREMENT, THESE LINES SHALL BE DONE PRIOR TO SHALL BE BROOMED OR WASHED DOWN, AND OBSTRUCTIONS, GRADE DIFFERENCES OR SPECIFICATIONS SHALL GOVERN. INSTALLATION OF ELECTRIC CONTROL (K) AUTOMATIC CONTROLLER LOCATION AND, ANY DAMAGE SUSTAINED ON THE WORK OF DISCREPANCIES IN AREA DIMENSIONS EXIST VALVES. INSTALLATION: THAT MIGHT NOT HAVE BEEN CONSIDERED IN (B) EXCAVATIONS: OTHERS SHALL BE REPAIRED TO ORIGINAL 1 AUTOMATIC CONTROLLERS SHALL BE CONDITIONS. VII. EQUIPMENT TO BE FURNISHED ENGINEERING. SUCH OBSTRUCTIONS OR 1) EXCAVATIONS SHALL BE OPEN VERTICAL ) IN TH SUSTAINED HA R PRESSUE SHALL BE SUSED E DIFFERENCES SHOULD BE BROUGHT TO THE CONSTRUCTION SUFFICIENTLY WIDE TO 2) INSTALLED AT LOCATIONS SHOWN ON THE DELIVER THE FOLLOWING OPERATING AND ATTENTION OF THE LANDSCAPE ARCHITECT. PROVIDE FREE WORKING SPACE AROUND LINES FOR NOT LESS THAN TWO (2) PLANS. ALL PEDESTAL MOUNTED (S) GUARANTEE THE ENTIRE SPRINKLER SYSTEM MAINTENANCE TOOLS TO THE CITY INSPECTOR IN THE EVENT THIS NOTIFICATION THE WORK INSTALLED AND To PROVIDE HOURS. IF LEAKS DEVELOP, THE JOINTS CONTROLLERS SHALL BE MOUNTED ON A SHALL BE GUARANTEED BY THE CONTRACTOR WHEN WORK IS COMPLETED AND PRIOR TO FINAL IS NOT PERFORMED, THE AMPLE SPACE FOR BACKFILLING AND SHALL BE REPLACED AND THE TEST SUITABLE CONCRETE BASE. AS TO MATERIAL AND WORKMANSHIP, ACCEPTANCE OF WORK: -~-- IRRIGATION CONTRACTOR SHALL ASSUME TAMPING. REPEATED UNTIL THE ENTIRE SYSTEM IS INCLUDING SETTLING OF BACKFILLED AREAS FULL RESPONSIBILITY FOR ANY REVISION PROVED WATERTIGHT. 2) ALL CONTROLLER LOCATIONS ARE BELOW GRADE FOR A PERIOD OF ONE (1) (A) ONE (1) WRENCH FOR DISASSEMBLY AND 2) TRENCHES FOR PIPE SHALL BE CUT TO ESSENTIALLY DIAGRAMMATIC AND SHALL ADJUSTMENT OF EACH TYPE OF SPRINKLER NECESSARY.- � YEAR FOLLOWING THE DATE OF FINAL REQUIRED GRADE LINES, AND COMPACTED 3) TESTS SHALL BE OBSERVED AND BE SPECIFICALLY LOCATED, BY THE ACCEPTANCE OF THE"WORK. IF, WITHIN ONE HEAD SUPPLIED. (E) PERMITS AND FEES THE CONTRACTOR TO PROVIDE AN ACCURATE GRADE AND APPROVED BY THE CITY INSPECTOR OWNER OR HIS REPRESENTATIVE. YEAR FROM THE DATE OF COMPLETION, (B) TWO (2) KEYS FOR EACH AUTOMATIC SHALL OBTAIN AND PAY FOR ANY AND ALL UNIFORM BEARING FOR THE FULL LENGTH PRIOR TO BACKFILL. PERMITS AND ALL INSPECTIONS AS REQUIRED. OF THE LINE. 3) ALL LOCAL AND APPLICABLE CODES SHALL SETTLEMENT OCCURS AND ADJUSTMENTS IN CONTROLLER AND/OR ENCLOSURE. TAKE PRECEDENCE IN THE FURNISHING PIPES VALVES AND SPRINKLER HEADS (C) TWO 2 QUICK COUPLER KEYS WITH SWIVEL (F) MANUFACTURER'S DIRECTIONS - 3) WHEN TWO PIPES ARE TO BE PLACED IN 4) UPON COMPLETION OF EACH PHASE OF FINISH GRADE OR PAVING IS NECESSARY TO HOSE( BIBS. MANUFACTURER'S DIRECTIONS AND DETAILED AND/OR CONNECTING A 110 VOLT THE SAME TRENCH IT IS REQUIRED TO THE WORK, THE CONTRACTOR SHALL ELECTRICAL SERVICE TO THE BRING THE SYSTEM, FINISH GRADE OR (D) TWO (2) KEYS FOR OPENING VALVE BOXES. DRAWINGS SHALL BE FOLLOWED IN ALL CASES MAINTAIN A 6 -INCH SPACE BETWEEN PIPES CHECK AND ADJUST EACH SPRINKLER PAVING TO THE PROPER LEVEL, THE CONTROLLER. THIS SERVICE WILL BE WHERE THE MANUFACTURERS OF ARTICLES AS A MINIMUM. HEAD TO MEET THE SITE REQUIREMENTS CONTRACTOR, AS PART OF THE WORK UNDER (E) TWO (2) SPECIAL WRENCHES SUITABLE FOR USED IN THIS CONTRACT FURNISH AND PLAN. PROVIDED BY THE DEVELOPER. HIS CONTRACT, SHALL MAKE ALL OPERATING EACH TYPE OF SHUTOFF VALVE DIRECTIONS COVERING POINTS NOT SHOWN IN 4) DEPTH OF TRENCHES SHALL BE 4) PROVIDE AN ON/OFF ELECTRICAL POWERADJUSTMENTS WITHOUT EXTRA COST TO THE INSTALLED. THE DRAWINGS AND SPECIFICATIONS. SUFFICIENT TO PROVIDE A MINIMUM (F) BACKFILLING: COVER ABOVE THE TOP OF THE PIPE AS SWITCH FOR EVERY IRRIGATION CSA., INCLUDING THE COMPLETE (G) ORDINANCES AND REGULATIONS - ALL FOLLOWS:,� 1) BACKFILL SHALL NOT BE PLACED UNTIL CONTROLLER AT EACH CONTROLLER RESTORATION OF ALL DAMAGED PLANTING, LOCAL, MUNICIPAL AND STATE LAWS, AND a) 24 INCH OVER MAIN LINE (2 OR THE INSTALLED SPRINKLER IRRIGATION ENCLOSURE. PAVING, OR OTHER IMPROVEMENTS OF ANY KIND. VIII. GUARANTEE RULES AND REGULATIONS GOVERNING OR LARGER) SHOULD ANY OPERATIONAL DIFFICULTIES IN RELATING TO ANY PORTION OF THIS WORK b) 18 INCH OVER MAIN LINE (1 1/2" OR SYSTEM HAS BEEN INSPECTED AND (L) CONTROLLER WIRING -ALL ELECTRICAL (A) THE GUARANTEE FOR THE SPRINKLER APPROVED BY THE CITY INSPECTOR. EQUIPMENT AND WIRING SHALL COMPLY WITH CONNECTION WITH THE SPRINKLER SYSTEM IRRIGATION SYSTEM SHALL BE MADE IN ARE HEREBY INCORPORATED INTO AND MADE SMALLER). DEVELOP WITHIN THE. SPECIFIED GUARANTEE A PART OF THESE SPECIFICATIONS, AND c) 12 INCH OVER NON—PRESSURE LATERAL 2 BACKFILL MATERIAL SHALL BE APPROVED LOCAL AND STATE CODES AND BE INSTALLED ACCORDANCE WITH THE CITY OF RIVERSIDE.. THEIR PROVISIONS SHALL BE CARRIED OUT LINES ) PERIOD WHICH IN THE OPINION OF THE BY THECONTRACTOR. ANYTHING d ALL SLEEVED MAINLINES AT STREET CROSSINGS SOIL. UNSUITABLE MATERIAL, INCLUDING BY THOSE SKILLED AND LICENSED IN THE THE GENERAL CONDITIONS AND ) CLODS AND ROCKS OVER 2 1/2 INCHES TRADE. UNLESS THE GOVERNING CODE CSA., MAY BE DUE TO INFERIOR MATERIAL SUPPLEMENTARY CONDITIONS OF THESE CONTAINED IN THESE SPECIFICATIONS SHALL SHALL BE INSTALLED WITH A MINIMUM COVER IN SIZE, SHALL BE REMOVED FROM THE SPECIFIES OTHERWISE, LOW VOLTAGE AND/OR WORKMANSHIP, SAID DIFFICULTIES SPECIFICATIONS SHALL BE FILED WITH THE NOT BE CONSTRUED TO CONFLICT WITH ANY DEPTH OF 24 TO TOP OF SLEEVE. PREMISES AND DISPOSED OF LEGALLY AT CONTROL WIRE MAY BE INSTALLED BY THE SHALL BE IMMEDIATELY CORRECTED BY THE CITY INSPECTOR PRIOR TO ACCEPTANCE OF THE ABOVE RULES AND REGULATIONS OR 5) WHERE IT IS NECESSARY TO EXCAVATE NO COST TO THE DEVELOPER. CONTRACTOR WHEN CODE ALLOWS. CONTRACTOR TO THE" SATISFACTION OF THE OF THE IRRIGATION SYSTEM. REQUIREMENTS OF THE SAME. HOWEVER, ADJACENT TO EXISTING TREES, THE CSA. AT NO ADDITIONAL COST TO THE WHEN THESE SPECIFICATIONS AND DRAWINGS CONTRACTOR SHALL USE ALL POSSIBLE 3) ALL BACKFILLING SHALL BE DONE 1) PILOT WIRES SHALL BE A DIFFERENT CSA. INCLUDING ANY .AND ALL OTHER (B) A COPY OF THE GUARANTEE FORM SHALL BE CALL FOR OR DESCRIBE MATERIALS, CARE TO AVOID INJURY To TREES AND CAREFULLY AND SHALL BE PROPERLY COLOR FOR EACH AUTOMATIC DAMAGE CAUSED BY .SUCH DEFECTS. INCLUDED IN THE OPERATIONS AND WORKMANSHIP, OR CONSTRUCTION OFA TREE ROOTS. EXCAVATION IN AREAS TAMPED. SANDY SOIL ONLY SHALL BE CONTROLLER, I.E., CONTROLLER "A", MAINTENANCE MANUAL. BETTER QUALITY, HIGHER STANDARD, OR WHERE TWO (2) INCH AND LARGER ROOTS TAMPED AND PUDDLED TO ELIMINATE ANY BLACK, CONTROLLER "B", RED, ETC. V. RECORD AND AS -BUILT DRAWINGS: (C) THE GUARANTEE FORM SHALL BE RETYPED LARGER SIZE THAN IS REQUIRED BY THE OCCUR SHALL BE DONE BY HAND. ALL VOIDS. PROVIDE TWO (2) ADDITIONAL PILOT ONTO THE CONTRACTORS LETTERHEAD AND ABOVE RULES AND REGULATIONS, THE ROOTS TWO (2) INCHES AND LARGER IN (A) THE CONTRACTOR SHALL PROVIDE AND KEEP 4) SURPLUS EARTH REMAINING AFTER WIRES (ORANGE COLOR) FOR EACH CONTAIN THE FOLLOWING INFORMATION: PROVISIONS OF THESE SPECIFICATIONS AND DIAMETER, EXCEPT DIRECTLY IN THE UP TO DATE A COMPLETE AS -BUILT RECORD COMMON WIRES SHALL BE DRAWINGS SHALL -TAKE PRECEDENCE. PATH OF PIPE OR CONDUIT, SHALL BE BACKFILLING SHALL BE DISPOSED CONTROLLER. SET OF BLUELINE OZALID PRINTS WHICH TUNNELED UNDER AND SHALL BE HEAVILY AS DIRECTED BY THE ON—SITE WHITE FOR EACH CONTROLLER. SHALL BE CORRECTED DAILY AND SHOW GUARANTEE FOR SPRINKLER IRRIGATION SYSTEM (H) DISRUPTION OF SERVICES PERMISSION TO WRAPPED WITH BURLAP, To PREVENT SUPERINTENDANT. 2) AN EXPANSION CURL SHALL BE PROVIDED EVERY CHANGE FROM THE ORIGINAL SHUT OFF ANY WATER LINES MUST BE SCARRING OR EXCESSIVE DRYING. WHERE OBTAINED FROM THE OWNER/DEVEOPER, WHO A DITCHING MACHINE IS RUN CLOSE TO 5) WHERE EXCAVATING OR "JACKING" IS IWITHIN THREE FEET (3) FOR EACH WIRE DRAWINGS SAND SPECIFICATION AND EXACT "WE HEREBY GUARANTEE THAT THE SPRINKLER WILL MAKE THE NECESSARY ARRANGEMENTS. TREES HAVING ROOTS SMALLER THAN TWO REQUIRED UNDER ASPHALT PAVEMENT, CONNECTION AND AT EACH CHANGE IN AS -BUILT LOCATIONS, SIZES AND KINDS OF IRRIGATION SYSTEM WE HAVE FURNISHED AND DISRUPTION OF EXISTING SYSTEMS SHALL BE (2) INCHES IN DIAMETER, THE WALL OF SIDEWALKS, ROADS, ETC. CARE SHALL BE DIRECTION, AND PROVIDED EVERY 100 EQUIPMENT. PRINTS FOR THIS PURPOSE MAY INSTALLED IS FREE FROM DEFECTS IN MATERIALS - KEPT TO A MINIMUM. THE TRENCH ADJACENT TO THE TREE TAKEN IN BACKFILLING WITH SAND, FEET ON RUNS OF MORE THAN 100 FEET IN BE OBTAINED FROM THE CSA. AT COST. AND WORKMANSHIP, AND THE WORK HAS BEEN (I) SOURCE OF WATER SUPPLY -THE SHALL BE HAND TRIMMED, MAKING CLEAN TAMPING AND INUNDATING WITH WATER. LENGTH. EXPANSION CURLS SHALL BE THIS SET OF DRAWINGS SHALL BE KEPT ON COMPLETED IN ACCORDANCE WITH THE DRAWINGS CUTS THROUGH ROOTS ONE (1) INCH AND FORMED BY WRAPPING AT LEAST FIVE (5) THE SITE AND SHALL BE USED ONLY AS A AND SPECIFICATIONS, ORDINARY WEAR AND TEAR - CONTRACTOR SHALL VERIFY AND BE LARGER IN DIAMETER. CUTS SHALL BE 6) SAND BACKFILL, WHERE REQUIRED SHALL TURNS OF WIRE AROUND A ONE INCH (1 ") RECORD SET. AND UNUSUAL ABUSE, OR NEGLECT EXCEPTED. FAMILIAR WITH THE LOCATION, SIZE AND PAINTED WITH TWO COATS OF TREE SEAL, BE PER DETAILS) ON PLAN. DIAMETER PIPE THEN WITHDRAWING THE PIPE. WE AGREE TO REPAIR OR REPLACE ANY DEFECTS DETAIL OF STUBOUTS, PROVIDED AS THE OR EQUAL. TRENCHES ADJACENT TO (B) THESE DRAWINGS SHALL ALSO SERVE AS IN MATERIAL OR WORKMANSHIP WHICH MAY SOURCE OF WATER SUPPLY TO THE SPRINKLER TREES SHOULD BE CLOSED WITHIN (G) TEMPORARY REPAIRS - THE DEVELOPER RESERVES (M) COVERAGE TEST - WHEN THE SPRINKLER WORK PROGRESS SHEETS AND THE SYSTEM, AS SHOWN ON PLANS. TWENTY—FOUR (24) HOURS. WHEN THIS IS THE RIGHT TO MAKE TEMPORARY REPAIRS AS SYSTEM IS COMPLETED, THE CONTRACTOR, IN CONTRACTOR SHALL MAKE NEAT AND LEGIBLE DEVELOP DURING THE PERIOD OF ONE YEAR FROM NOT POSSIBLE THE SIDE OF THE TRENCH DATE OF ACCEPTANCE AND ALSO TO REPAIR OR (J) EXISTING UTILITIES AND CONDITIONS - PRIOR ADJACENT TO THE TREE SHALL BE KEPT, NECESSARY TO KEEP THE SPRINKLER SYSTEM THE PRESENCE OF THE CITY INSPECTOR, ANNOTATIONS THEREON DAILY AS THE WORK REPLACE ANY DAMAGE RESULTING FROM THE TO CUTTING INTO THE SOIL, THE SHADED WITH BURLAP OR CANVAS. EQUIPMENT IN OPERATING CONDITION. THE SHALL PERFORM A TEST COVERAGE OF WATER PROCEEDS, SHOWING THE WORK AS ACTUALLY REPAIRING OR REPLACING OF SUCH DEFECTS AT CONTRACTOR SHALL LOCATE ALL CABLES, EXERCISE OF THIS RIGHT BY THE DEVELOPER SHALL AFFORDED THE PLANTING AREAS, COMPLETE INSTALLED. THESE DRAWINGS SHALL BE NO ADDITIONAL COST TO THE DEVELOPER. WE SHALL CONDUITS, SEWERS, SEPTIC TANKS AND 6) PRESSURE MAIN SUPPLY LINES 1 1/2 NOT RELIEVE THE CONTRACTOR OF HIS AND ADEQUATE. THE CONTRACTOR SHALL AVAILABLE AT ALL TIMES FOR INSPECTION MAKE SUCH REPAIRS OR REPLACEMENTS WITHIN A OTHER SUCH UTILITIES AS ARE COMMONLY INCHES OR SMALLER SHALL BE SCHEDULE RESPONSIBILITIES UNDER THE TERMS OF THE FURNISH ALL MATERIALS AND PERFORM ALL AND SHALL BE KEPT IN A SAFE LOCATION ENCOUNTERED UNDERGROUND AND HE SHALL 40 PVC PIPE, AND CLASS 315 PVC PIPE GUARANTEE AS HEREIN SPECIFIED. WORK REQUIRED TO CORRECT ANY ON THE JOB SITE. REASONABLE TIME, AS DETERMINED BY THE LANDSCAPE TAKE PROPER PRECAUTIONS NOT TO DAMAGE FOR 2 INCHES OR LARGER. ALL LATERAL (H) SPRINKLERS: INADEQUACIES OF COVERAGE DISCLOSED. ARCHITECT, AFTER RECEIPT OF WRITTEN NOTICE. IN OR DISTURB SUCH IMPROVEMENTS. IFA LINES SHALL BE SCHEDULE 40 PVC PIPE. (C) BEFORE THE DATE OF THE FINAL THE EVENT OF OUR FAILURE TO MAKE SUCH CONTRACTOR SHALL INFORM THE CITY INSPECTION THE CONTRACTOR SHALL CONFLICT EXISTS BETWEEN SUCH OBSTACLES 1) ALL NOZZLES ON SPRINKLERS SHALL BE REPAIRS OR REPLACEMENTS WITHIN A REASONABLE 7) :ALL IRRIGATION LINES UNDER PAVING INSPECTOR OF ANY DEVIATION TRANSFER ALL INFORMATION FROM THE AND THE PROPOSED WORK THE CONTRACTOR TIGHTENED. AFTER INSTALLATION. ALL TIME AFTER RECEIPT OF WRITTEN NOTICE FROM SHALL BE SLEEVED IN SCHEDULE 40 PVC FROM THE PLAN REQUIRED DUE TO AS—BUILT PRINTS TO A MYLAR SET, SHALL PROMPTLY NOTIFY THE CSA REP. SPRINKLERS HAVING AN ADJUSTMENT THE LANDSCAPE ARCHITECT, WE AUTHORIZE THE WHO WILL ARRANGE FOR RELOCATIONS. PIPE FOR 1 1/2 INCHES OR SMALLER, AND STEM SHALL BE ADJUSTED ON A LATERAL WIND, PLANTING, SOIL OR SITE CONDITIONS, ALL WORK SHALL NEAT AND LEGIBLE DEVELOPER TO PROCEED TO HAVE SAID REPAIRS OR THE CONTRACTOR WILL PROCEED IN CLASS 315 PVC PIPE FOR 2 INCHES OR THAT BEAR ON PROPER COVERAGE. LARGER. SLEEVES SHALL BE AT LEAST LINE FOR THE PROPER RADIUS, DIAMETER PREPARED IN INK. REPLACEMENTS MADE AT OUR EXPENSE AND WE THE SAME MANNER IF ROCK LAYER OR ANY OTHER CONDITION ENCOUNTERED TWICE THE DIAMETER OF THE PIPE OR AND/OR GALLONAGE. (N) INSPECTION OF WORK: WILL PAY THE COSTS AND CHARGES THEREFORE WITH A UNDERGROUND MAKES CHANGES ADVISABLE. WIRE BUNDLE TO BE ENCLOSED, 2) ALL SPRINKLER HEADS SHALL BE SET RIVERSIDE CITY SERVICE AREA:. (D) THE CONTRACTOR SHALL DIMENSION FROMUPON DEMAND." MINIMUM TWO INCH SIZE. PERPENDICULAR TO FINISHED GRADES (951) 600-1314 FOR THE FOLOWING TWO (2) PERMANENT POINTS OF REFERENCE, WHERE INVESTIGATION OF SUBSURFACE CONDITIONS UNLESS OTHERWISE DESIGNATED ON INSPECTIONS 48 HOURS NOTICE BUILDING CORNERS, SIDEWALK OR ROAD HAVE BEEN MADE BY A QUALIFIED BODY IN AREAS 8) ALL PVC IRRIGATION LINES SHALL BE PLANS. REQUIRED: INTERSECTIONS, ETC., THE LOCATION OF WHERE WORK IS WORK IS TO BE PERFORMED OR IN INSTALLED IN TRENCHES WITH IN WHICH LOCAL MATERIALS MAY BE OBTAINED, NOMENCLATURE LETTERING FACING UP. 3) ALL SPRINKLER RISERS SHALL BE 1) PRE -JOB MEETING. (7 CAL. DAYS) THE FOLLOWING ITEMS: LOCAL MATERIALS MAY BE OBTAINED, CONTRACTOR MAY INSTALLED AS INDICATED ON PLANS AND 1) CONNECTION TO EXISTING WATER LINES. SHOWN ON DETAILS. 2) PRESSURE MAIN INSTALLATION AND REQUEST THE USE OF SUCH INFORMATION BUT WILL BE TESTING. 2) CONNECTION TO EXISTING ELECTRICAL POWER. DIRECTLY RESPONSIBLE FOR ITS VERIFICATION AND ACCURACY. REV. REVISION DESCRIPTION DATE ENGR. CITY DATE DN(5 tOOAF4., FRANK £SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT BENCHMARK: CITY BM#536 CITY OF FONTANA, CALIFORNIA RADMACHER q� ° COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL PK `'� ,�y�SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER�W&T, NORAILINT CUR RETURN AT THE IRRIGATION SPECIFICATION'ASSOCIATES INC. ''� �' THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS NORTHEAST CURB RETURN AT THE INTERSECTION OF MILLER AVENUE DRAWN BY: V.V. SCALE: �gnoture TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND AND JUNIPER AVENUE. CITRUS GROVE NONE 5/31/18 ELEV. =1362.61 TR. 17760 FONTANA, CA 92335 � Re of * DIAL TWO woRKINc STANDARDS IN EFFECT. DATE: 1�13�2017 Landscape Architects s �° Q BEFORE DAYS BEFORE q Dote �� YOU DIG YOU DIG PHONE (714) 832-1774 FAX (714) 832-5721 lroll FREE 1-800-2 27-2600 14841 Yorba Street, Suite 204 Tustin, CA 92780 F OF C A\ \E� A PUBLIC SERVICE BY CHECKED BY: APPROVED BY: DRAWING NO.: 8 UNDERGROUND SERVICE ALERT EMAEL: FRA1110@FRAINC.NET CITY ENGINEER R.C.E. 51152 DATE: 10