HomeMy WebLinkAbout5583-7....:... .. ..
1
O1 RAIN BIRD RWS-M-B-C-1402 (INCLUDES RETAINER, 18' TUBE,
0.5 GPM BUBBLER & INTEGRATED CHECK VALVE, 4" GRATE,
1/7 NPT INLET SPIRAL BARB ELBOW) .
O BUBBLER: RAIN BIRD 1401 0.25 GPM
4 Z 3 FINISH GRADE/TOP OF MULCH
O 4" LOCKING GRATE (INCLUDED)
O 1/2" SWING ASSEMBLY: RAIN BIRD SA -125050
OR
1/2" SWING PIPE: RAIN BIRD SP SERIES WITH 1/2" MALE NPT
x 0.490" BARB ELBOW: RAIN BIRD SBE -050
1 O PVC SCH 40_TEE OR EL
O PVC OR POLYETHYLENE LATERAL PIPE
O 4" WIDE X 18" LONG RIGID BASKET WEAVE CANISTER (INCLUDED)
5 O9 OPTIONAL SOCK (RWS-SOCK) FOR SANDY SOILS
8
-- 6 7
NOTES:
1. 4" GRATE IS ALSO AVAILABLE IN PURPLE (RWS-GRATE-P).
2.' INSTALL PRODUCT SO THAT THE GRATE IS EVEN WITH FINISH GRADE OR TOP OF MULCH.
3.. OPTIONAL SAND SOCK (RWS-SOCK) IS 34: IN LENGTH. CUT TOAENGTH NEEDED TO COVER MESH
BASKET AREA
4. WHEN INSTALLING IN EXTREMELY HARD OR CLAY SOILS, ADD 3/4" GRAVEL UNDER AND AROUND THE
UNIT TO ALLOW FASTER WATER INFILTRATION AND ROOT PENETRATION.
5.. ONCE RWS-M HAS BEEN INSTALLED FILL THE BASKET WITH PEA GRAVEL BEFORE LOCKING LID.
I A) -.-.TREE BUBBLER..
N.T.S.
I.. 2
INSET B .
1 2 INSET C
NOTES: _
1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED $
ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE . 13
INSTALLATION SPECIFICATIONS ON RAIN BIRD WEB SITE I;
(WWW.RAINBIRD.COM) FOR SUGGESTED SPACING. 1 g
2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE
MAXIMUM SPACING SHOWN IN THE ACCOMPANYING TABLE.
O QF -FLUSH HEADER
O PRE-INSTALLED BARB FITTING
O FLUSH POINT WITH PVC CAP OR OPTIONAL_
PVC BALL VALVE
O PERIMETER OF AREA
OPERIMETER DRIPLINE PIPE TO BE INSTALLED 2" -4".: -
FROM PERIMETER OF AREA
O PVC SUPPLY PIPE FROM RAIN BIRD CONTROL ZONE KIT.
(SIZED TO MEET LATERAL ,FLOW. DEMAND)
OF -SUPPLY HEADER
O RAIN. BIRD XFCV SERIES DRIPLINE (TYPICAL)
O MALE ADAPTER INSERT
O STAINLESS STEEL, OETIKER OR MURRAY CLAMP
1 p OPERATION INDICATOR RAIN BIRD. MODEL: OPERIND.'
11 PVC SCH 40 CAP
12 PVC SCH 40 BALL VALVE
13 RAIN BIRD XF SERIES BLANK TUBING
14 BARB X BARB INSERT TEEN
RAIN BIRD XFF-TEE (TYPICAL)
15 PVC SCH 40 ELL (TYPICAL)
16 PVC SCH 40 RISER PIPE
17 XF SERIES TIE -DOWN STAKES (TDS-050)
REFER TO RAIN BIRD DRIPLINE DESIGN GUIDE FOR .
PROPER SPACING
XFCV Dripline Maximum Lateral Lengths
Inlet Pressure psi
12" Spacing
18" Spacing
Nominal Flow (gph)
Nominal Flow (gph)
0.6
0.9
0.6
0.9
..20
192
136.
254
215..
30
289
205
402
337
40
350
248
498.
416
50
397
281.
573
477 .
.60
436
309
637.
529:.
DATE ENGR. CITY DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT BENCH MARK CITY BM #536
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, PK NAIL IN THE NORTH END OF THE
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS INTERSECTION OF MILLER AVENUE
TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND AND JUNIPER AVENUE.
STANDARDS IN EFFECT. ELEV. =1362.61
i
i
N.T.S.
CITY OF FONTANA, CALIFORNIA
IRRIGATION DETAILS....:
DRAWN BY: V.V.SCALE:. .
CITRUS GROVE NONE
TR. 17760 FONTANA, CA 92335 DATE:
1/13/2017