HomeMy WebLinkAbout5485-1w ♦
TRAFFIC SIGNAL GENERAL NOTES
1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT
OF ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN
PUBLIC RIGHT-OF-WAY WITH IN THE CITY LIMITS. CALL (909) 350-7610.
2. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM
TO THESE PLANS, THE ' CITY OF FONTANA STANDARD SPECIFICATIONS, THE STANDARD
PLANS AND SPECIFICATIONS OF THE STATE OF CALIFORNIA, DATED 2010, AND THE
CALIFORNIA MANUAL OF TRAFFIC CONTROL DEVICES, DATED 2014.
3. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL
POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE
JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE
UNDERGROUND SERVICE ALERT AT (800) 227-2600. TWO (2) WORKING DAYS BEFORE
DIGGING.
4. CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT
THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT ANY CITY
FURNISHED OR PROVIDED AS NOTED IN SECTION E.
-5., ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 3" RIGID METAL UNLESS
OTHERWISE SHOWN.
6. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH
SOUTHERN CALIFORNIA EDISON COMPANY FOUR WEEKS IN ADVANCE OF NEED.
7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND SECTION E.
8. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
9. CONTROLLER AND SERVICE CABINETS SHALL NOT BE SUBJECTED TO WATER FROM
SPRINKLERS. CONTRACTOR SHALL MODIFY SPRINKLERS SYSTEMS AS NECESSARY.
1 d. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL
REPLACED WITH NEW TRAFFIC SIGNALS AND LIGHTING.
11. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR
POTENTIAL CONFLICT WITH THESE PLANS AND,OR SPECIFICATIONS FOR THIS PROJECT.
12. TRENCH REPAIRS SHALL BE PER SPECIAL PROVISIONS, SECTION E AND CITY STANDARD
PLAN 1008.
13. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO
THE CITY ENGINEER.
CITY OF FONTANA
SIERRA AVE AND RIVERSIDE AVENUE
TRAFFIC SIGNAL IMPROVEMENTS
PROJECT SITE
VICINITY MAP
NOT TO SCALE
TRAFFIC SIGNAL CONSTRUCTION NOTES
NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS,
a1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET,
LOOP DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL
BE INSTALLED PER CITY STANDARD PLAN 4001. CONTRACTOR SHALL FURNISH AND INSTALL ANY
ADDITIONAL EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN.
INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN
CALIFORNIA EDISON COMPANY REQUIREMENTS.
a FURNISH k INSTALL 2"C. 216, 1#8 CONDUCTORS (SIGNAL SERVICE)
FURNISH do INSTALL 2"C. 2#10 CONDUCTORS (LUMINAIRES)
FURNISH AND INSTALL 3" PVC CONDUIT WITH Um POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE
SERVICE WITH SCE PLANNING DEPARTMENT AT 909.357.6116. VERIFY PHONE NUMBERS AT TIME OF
CONSTRUCTION
E6 REMOVE EXISTING LANDSCAPING AND MODIFY IRRIGATION SYSTEM AS NECESSARY. CONSTRUCT 4" THICK PCC
PAD ON COMPACTED NATIVE AROUND PROPOSED SIGNAL CONTROLLER AND SERVICE CABINETS. SPRINKLERS
SHALL NOT SPRAY ONTO CONTROLLER CABINET OR SERVICE PEDESTAL
�j INSTALL CITY -FURNISHED UNI -DIRECTIONAL. SINGLE CHANNEL OPTICOM DETECTOR, PER DETAIL B
ON SHEET 2 AND AS DIRECTED BY THE ENGINEER
® INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N.
❑9 FURNISH AND INSTALL SIGN ON SIGNAL POLE AS SHOWN. MOUNTING SHALL BE PER
CALTRANS STD. PLANS RS4.
10 FURNISH AND INSTALL DIMENSION BATTERY BACK-UP SYSTEM PER MANUFACTURERS
REQUIREMENTS.
LEGEND:
A*�-- PROPOSED SIGNAL EQUIPMENT
OPROPOSED TYPE E LOOP
f
PROPOSED TYPE D LOOP
LEGEND: SIGN LEGEND
REMOVE EXISTING PROPOSED
INDEX OF SHEETS:
TYPE IV (L or R) PAVEMENT ARROW
DRAWING NUMBER
5484 -STREET IMPROVEMENT PLAN
ROADSIDE SIGN 5485 -TRAFFIC SIGNAL PLAN
- R3-4 R3-18 OM1 -3 R9_3
5486 -SIGNING AND STRIPING PLAN
------------ TRAFFIC STRIPE OR MARKING 36 X 36 36 X 36 .18' X 18'
CITY OF RIALTO DEPARTMENT OF PUBLIC WORKS
APPROVED BY:
Y74/017
ROBERT EISENBEISZ, PUBLIC WORKS DIRECTOR/CITY ENGINEER, RCE 54931 DATE
UNDERGROUND SERVICE ALERT (USA)REV. REVISION DESCRIPTION DATE ENGR. CITY DATE Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA
SHOULD CONSTRUCTION OF THE REQUIRED QapFESS/04 KOA COPA30RArnON
IT'S -THE LAW! IMPROVEMENTS NOT COMMENCE WITHIN TWO ���� ANG GU4��Ey PLANNING & ENGINEERING TITLE SHEET
YEARS OF THE DATE OF APPROVAL SHOWN HEREON 3190 C. Shelby Street DRAWN BY: SIERRA AVENUE SCALE:
DIAL BEFORE ! y ti `y
YOU DIG! ! Ontario, California 91764 AND As Noted
AND CARRIED FORTH IN A DILIGENT MANNER, THE Na 75793 Tel: (909) 890-9693 Fax: (909) 890-9694
CITY ENGINEER MAY REQUIRE. REVISIONS TO THE �• 6/30/18 DESIGNED BY: DATE:
CALL AT LEAST a * BENCH MARKalv&: FONTANA BM8-17 ELEV 1428.609 RIALTO BM042-88 ELEv 1924.262 RIVE DE AVENUE
TWO WORKING DAYS Knowwhaftbelow. PLANS TO BRING THEM INTO CONFORMANCE WITH sT7TfOFCAI�Fp��\P DESCRIPTION: CITY OF FONTANA BM #8-17: BRASS CAP IN CONCRETE BASE OF SOUTH LEG OF AN i CHECKED BY: PP VE B DRAWING NO..-
BEFORE
O..-
BEFORE YOU DIG Call before you dig. SCE TOWER, 343' NORTH OF HIGHLAND AVE AND 0.2 MILES WEST OF SAN SEVAINE ROAD. ` n .�. 1
STANDARDS IN EFFECT. CITY OF RIALTO BM #042-88 :BRASS DISK IN TOP OF SOUTHERLY CURB RIVERSIDE AVENUE 0.25 DATE: I �F/11 DATE` 5485 2
MILES SOUTHEAST OF SIERRA AVENUE. MING UAN. R.C.E. 75793 N ANA ENGINEER 11
t