HomeMy WebLinkAbout5535-101 _.1 R,+ 10+50 SEE SHEET 7 CCI SEWER CONSTRUCTION NOTES: Ol INSTALL 8' V.C.P., C700 EXTRA STRENGTH, SEWER, AND REPAIR TRENCH PER CITY STD. PLAN NO. 1008. O2 INSTALL STANDARD CAST IN PLACE MANHOLE FOR SEWER PER CITY OF FONTANA STD. PLAN NO. 2001 (I.D. = 48"). 4O INSTALL 4- V.C.P., C700 EXTRA STRENGTH, SEWER LATERAL AND CLEANOUT PER CITY OF FONTANA STD. PLAN NO. 2005 & 2006. OINSTALL BACK—WATER VALVE PER CALIFORNIA PLUMBING CODE, LATEST EDITION. SEE SHEET 5 in- ►,'•: 1 F.Al►1 I z Lei 1 Alm SECTION 4212/4217 OF THE GOVERNMENT CODE REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE WILL BE VALID. SEE SHEET 7 SEWER LINE "G" SEE SHEET 5 D', 0,A76F 11D e DIALTWO WORKING ]BEFORE DAYS BEFORE YOU DIG You DIG TOLL FREE —800-227-2600 REV. A PUBLIC SERVICE BY INDERGRMW SERVICE ALERT SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT. Prepared Under The ESupervision Of: ��QROFSS/p�,91 k SLLJ jpE, Fti r c- C 70862 m ADAMS STREETER Civil En gineers35 Corpmat Part, Irvine, U 92606 1 949.474�o � ae���r�l�l CADate: 9/23/16 NICHOLAS A. STREETER R.C.E. 70862 20' 15' 10' 5' d 20' 40' GRAPHIC SCALE. 1'=20' CITY OF FONTANA, CALIFORNIA SEWER IMPROVEMENT PLANS ON—SITE SANITARY SEWER SCALE: IMPROVEMENT PLAN FOR TRACT 18881 AS Noted LINE "G" STA. 10+00 TO 12+94.92 DATE:9/23/2016 APP ED Y: DRAWING NO.: 0 PEP SA OVAL R.C.E. 511 2 /� 5535 11