HomeMy WebLinkAbout5535-8IMPORTANT NOTICE
----------
1 11
SEE SHEET 6
—W
.*mm
w
HORIZ. 1' = 20'
VERT. 1' = 4'
SEWER CONSTRUCTION NOTES:
Ol INSTALL 8" V.C.P., C700 EXTRA STRENGTH, SEWER, AND REPAIR TRENCH PER CITY STD. PLAN NO. 1008. >,
n INSTALL STANDARD CAST IN PLACE MANHOLE FOR SEWER PER CITY OF FONTANA STD. PLAN NO. 2001 (I.D. = 48-).
O4 INSTALL 4' V.C.P., C700 EXTRA STRENGTH, SEWER LATERAL AND CLEANOUT PER CITY OF FONTANA STD. PLAN NO. 2005 & 2006.
O INSTALL BACK -WATER VALVE PER CALIFORNIA PLUMBING CODE, LATEST EDITION. C°
0
N
SEE SHEET 4
SECTION 4212/4217 OF THE GOVERNMENT
CODE REQUIRES A DIG ALERT IDENTIFICATION
NUMBER BE ISSUED BEFORE A PERMIT TO
EXCAVATE WILL BE VALID.
SEE SHEET 6
D_?
A JD
.c7'4hz' T
C-23
DIALTWO WORKING
BEFORE—('DAYS BEFORE
YOU DIG IG
DIG
TELL FREE -800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
SEWER LINE °E"
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
SEE SHEET 4
Prepared Under The
QROFESS/pSupervision Of:
PS k ST,p�, F�
F_ y ADAMS STREETER FCHECKEED
Z C 70862 Civil Engineers
y y 15 Corporxe Part, Imne, G 92606 1 949.47+2330 1 a��*-=
Date: 9/23/16
NICHOLAS A. STREETER R.C.E. 70862
U
O
_O
CL
CD
O
N
N
Q
N
Q)
a
a
Q
3
0
I
r7
w
w
cn
I
cn
w
Z'
O
mmm�
x
a�
3
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
SEE SHEET 4
Prepared Under The
QROFESS/pSupervision Of:
PS k ST,p�, F�
F_ y ADAMS STREETER FCHECKEED
Z C 70862 Civil Engineers
y y 15 Corporxe Part, Imne, G 92606 1 949.47+2330 1 a��*-=
Date: 9/23/16
NICHOLAS A. STREETER R.C.E. 70862
U
O
_O
CL
CD
O
N
N
Q
N
Q)
a
a
Q
3
0
I
r7
w
w
cn
I
cn
w
Z'
O
0
GRAPHIC SCALE. 1'=20' I Q
/
>
CITY OF FONTANA, CALIFORNIA
SEWER IMPROVEMENT PLANS
Ln
ON—SITE SANITARY SEWER SCALE: o
IMPROVEMENT PLAN FOR TRACT 18881 As Noted N
DATE: `n
LINE E STA. 10+00 TO 12+69.62 9/23/2016
LI;
D DRAWING NO.: 8 ED
• DATE: 1/0 �(�' �� 5535 /
RI .ARM SANF)nVAI R.C.E. 51152 11
x
a�
3
a>
Cn
O
Q)
20'
15'
10'
5'
0'
20'
40'E
0
GRAPHIC SCALE. 1'=20' I Q
/
>
CITY OF FONTANA, CALIFORNIA
SEWER IMPROVEMENT PLANS
Ln
ON—SITE SANITARY SEWER SCALE: o
IMPROVEMENT PLAN FOR TRACT 18881 As Noted N
DATE: `n
LINE E STA. 10+00 TO 12+69.62 9/23/2016
LI;
D DRAWING NO.: 8 ED
• DATE: 1/0 �(�' �� 5535 /
RI .ARM SANF)nVAI R.C.E. 51152 11