HomeMy WebLinkAbout5540-1STORM DRAIN GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS
AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (-GREEN BOOK-). ALL REFERENCE SPECIFICATIONS AND
STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVEDBY REFERENCE
TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY
ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
,
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING
DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING
DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALLBE REQUESTED AT LEAST TWO WORKING DAYS
PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE
OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY
TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL
DEVICES AT ALL TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN
DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING,
SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL
SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL
EXISTS FOR GROUND MOVEMENT.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR
THAT PURPOSE.
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILMES; AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT
UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS,
TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO
WORK AROUND THEIR FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY
AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER
REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE
WORK' TO, THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND
CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR
NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH
MARKS, SHALL BE DONE BY A REGISTERED CML ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE
DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE
WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE
SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
r•
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT
ALL TIMES.
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR
PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL
REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON
INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING
IMPROVEMENTS.
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF
CONNECTIONS., CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY -CORRECTNESS OF ELEVATIONS OR
LOCATIONS SHOWN ON THE PLANS.
27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL
NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
,
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING
CONTRACTOR UPON COMPLETION OF PAVING.
32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES AND OTHER TRAFFIC
CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD
DRAWINGS TO THE CITY ENGINEER.
IMPORTANT NOTICE
SECTION 4212/4217 OF THE GOVERNMENT
CODE REQUIRES A DIG ALERT IDENTIFICATION
NUMBER BE ISSUED BEFORE A PERMIT TO
EXCAVATE WILL BE VALID.
II I SHEET 4
p
I
LAT B-1 - - - - - - - - Q L
-- I SEB --
----- ---- ;I - ----------------------------------------�
----- ----- --,------- ----- - -
---------------SIERRA-LAKES-PARKWAY IL�
LOT 0
55 56 57 58 59 60 61 62 63 64 65 0 1
I� n -I
54
w
w
_ ( f 53 \
I
W
I, i 52
nQ
IaY ' R/W R/W
Z : U I51
Q I i , I
34ALI'
I ;12 i I 50 ' 22' 12'
i I FUTURE CURB AND
I,f ,
AC PAVEMENT 69
') T 2.0% ,
49 LAT A-3 - 5' 6'
i
III EXISTING GRADE STORM DRAIN
N I.
(SIZE PER PLAN)
48
w I SANITARY SEWER
w I (PER SEPARATE PLAN)
ILO
HEMLOCK AVENUE
LAT A-1 N.T.S.
"�4LAT A-1 R/W
52' 1 22'
ABBREVIATIONS
AC
ASPHALT CONCRETE
BW
BACK OF WALK
C.L.
CENTERLINE
EX.
EXISTING
FF
FINISHED FLOOR
FG
FINISHED GRADE
FS
FINISHED SURFACE
FH
FIRE HYDRANT
FL
FLOW LINE
G
GAS
GB
GRADE BREAK
HP
HIGH POINT
LF
LINEAL FEET
MAX
MAXIMUM
MH
MANHOLE
MIN
MINIMUM
PL
PROPERTY LINE
ROW
RIGHT OF WAY
S=
SLOPE OF PIPE
SD
STORM DRAIN
SWR
SEWER
SS
SANITARY SEWER
TC
TOP OF CURB
R TF
TOP OF FOOTING
TG
TOP OF GRATE
TW
TOP OF WALL
TYP
TYPICAL
10' I W
WATER
_ WM
WATER METER
WV
WATER VALVE
( 1 i
12' 40' '
I I I
PROPOSED CONNECTION TO SBCFCD
HIGHLAND CHANNEL
- 0/ \/ \\\ - _`-"-�" \ �. � `ice/ "�:� �/ �/'� �� / \�s~y ` ��~\ ,/•
V-------- _ 15' FUTURE CURB AND
------- AC PAVEMENT
HIGHLAND CHANNEL
36" SD
SIERRA LAKES PARKWAY
N.T.S.
INDEX MAP
onuiftwunt 01!
rv.
04 but b"ge a xx
Oval a)
SCALE: 1"=1009
>Iqzlclr rmme:
iawsdoenmts pip's aet�'�a>:.t M
r rodius tWJ
Supe ro it wt11 W. of pipe
bw nm a d
Tt pleal we"to 1
a;4 a rah. ._
r�~o
*atnt�enln� ..
SECS
PAN 0=1 Dow-W.80sastwepipe,
pie ora mmene:an
a to M a "own ae
` ' * tie p 1«i..
CONCRETE PIPE SAN
CONNECTION DETAIL CW CONTRsLDISTAXT
......
,Als!! a_3 0"t"
TE
R.Lx S-ffi
�_�� 3D31Lt _ . -3itr t�►Oil--
TRAPEZOID CHANNEL JUNCTION
STRUCTURE DETAIL (NOT TO SCALE)
TOLL FREE "-"1-800-227-2600
A PUBLIC SERVICE BY UNDERGRIAM SERVICE ALERT
r:
=wag a1 OW of pips
I
.--$t+iNt mid lesptiat�
acrd �trortarsd
=WWF a aof ww of Ii
t brokm)
ww Cam
mkir cbw e
PIPE CLOSURE -TYPE_ NBN
DOUBLE BRICK AND MORTAR BULKHEAD
DETAIL NOT TO SCALE)
REMSION DESCRIPTION
.CC.
VICINITY MAP
N. T. S.
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA FONTANA WATER COMPANY
8583 SIERRA AVENUE 909.822.2201
FONTANA, CA 92335
909.350.6632 SOUTHERN CA EDISON COMPANY
800.655.4555
CITY OF FONTANA SEWER SERVICE
8353 SIERRA AVENUE SOUTHERN CA GAS COMPANY
FONTANA, CA 92335 800.427.2200
909.350.7670
TIME WARNER CABLE
9280 SIERRA AVENUE #G
FONTANA, CA 92335
888.892.2253
LEGEND
BASIS OF BEARINGS: TRACT BOUNDARY
THE BEARING NORTH 89'3642" WESTON THE PROPOSED R/W
CENTERLINE OF HIGHLAND AVENUE AS SHOWN LOT LINES
ON RECORD OF SURVEY FILED IN BOOK 111
PAGES 99-106, IN THE CITY OF FONTANA, PROPOSED LOT NUMBER
COUNTY OF SAN BERNARDINO, STATE OF STREET LIGHT (S.L.)
CALIFORNIA, WAS USED AS THE BASE OF
BEARINGS. FIRE HYDRANT
EXISTING STORM DRAIN
BENCHMARK PROPOSED STORM DRAIN
BK 4016 f 1806 S. BER.CO.
FOUND CHISELED "+"AT THE SOUTH WEST
CORNER OF FLOOD CONTROL HEADWALL ON
THE EAST SIDE OF BEECH AVENUE 900'±
NORTH OF SOUTH HIGHLAND AVENUE.
5
ELEVATION: 1473.52' ENGINEER'S NOTICE TO CONTRACTOR
CONSTRUCTION NOTES:
NO.
DESCRIPTION
UNIT
Ol
CONSTRUCT TRAPEZOID CHANNEL JUNCTION STRUCTURE PER S.B. CO. STD. 200A.
EA
1
OINSTALL
18 RCP - D LOAD PER PROFILE AND REPAIR TRENCH PER CITY STD. NO.
1008.
LF
42
OINSTALL
11008-
24 RCP - D LOAD PER PROFILE AND REPAIR TRENCH PER CITY STD. NO.
LF
21
01008-
INSTALL 36 RCP - D LOAD PER PROFILE AND REPAIR TRENCH PER CITY STD. NO.
LF
533
OINSTALL
42 RCP - D LOAD PER PROFILE AND REPAIR TRENCH PER CITY STD. NO.
LF
378
OINSTALL
48 RCP - D LOAD PER PROFILE AND REPAIR TRENCH PER CITY STD. NO.
1008,
LF
483
7
CONSTRUCT JUNCTION STRUCTURE WITH MANHOLE PER CITY STD. NO. 3012.
EA
8
8
CONSTRUCT JUNCTION STRUCTURE PER CITY STD. STD. NO. 3010.
EA
1
9
CONSTRUCT DOUBLE BRICK AND MORTAR BULKHEAD PER PIPE CLOSURE.
EA
4
10
INSTALL 12" PVC SDR -35 AND REPAIR TRENCH PER CITY STD. NO. 1008.
LF
10
11
INSTALL PVC YARD DRAIN OUTLET. CUT PIPE FLUSH WITH INSIDE WALL AND FILL VOIDS
WITH WATERPROOF SILICON CAULK. FURNISH AND INSTALL STEEL RESTRICTOR PLATE PER
DETAIL SHEET 2.
EA
1
12
INSTALL PVC CAP AT END OF PIPE FOR FUTURE CONNECTION.
EA
1
13
CONSTRUCT CURB OPENING CATCH BASIN PER CITY STD. NO. 3004. "W"AND PER
EA
2
14
REMOVE AND REPLACE IN KIND CONCRETE SIDE WALL PANELS.
SF
575
15
LIMITS OF ACCESS ROAD RECONSTRUCTION. CONTRACTOR TO COMPACT TOP 12 INCHES
TO 95% RELATIVE COMPACTION AND REPLACE THE EXISTING STRUCTURAL SECTION'
INCLUDING ASPHALT AND BASE, IN KIND TO THE EXISTING AS MEASURED IN THE FIELD,
BUT AT A MINIMUM OF 3 INCHES OF AC OVER 4 INCHES OF CLASS II BA
SF
585
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
QROf ESS�6N-s
z 61
C 70862
V 1�
Jl CI
9lF OF CAI�F��
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE -
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO
PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR
THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT ON THESE
DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL
DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS
FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY
ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL
REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE
COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DISCREPANCIES. BEGINNING
OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER
VALVE BOXES, UTILITY BOXES, AND LIDS, ETC.
FINAL GRADE CERTIFICATION SHALL BE PROVIDED TO THE BUILDING AND
SAFETY INSPECTOR PRIOR TO FINAL INSPECTION.
SHEET INDEX
TITLE SHEET 1
STORM DRAIN PLAN PROFILES 2-4
STORM DRAIN LATERAL PROFILES 5
AND DETAILS
;
V
BASE. S.B.C.F.C.D. PERMIT: ! W
cn
z
Q
Prepared Under The
Supervision Of: CITY OF FONTANA, CALIFORNIA
�
OFF-SITE STORM DRAIN IMPROVEMENT PLANS IL-1
DRAWN BY: SCALE: �
ADAMS STREETER M: TRACT 18881 AS SHOWN
Civ! I. Engineers TITLE SHEET
15 Corporate Park, Irvine, CA 92606 949.4741Madam�streeeeroom DESIGNED BY: DATE: ~
M� 10/10/2016 Q
�%• Date: 10/10/16 CHECKED BY: APR ED B . / DRAWING NO -: I, Q
NS
DATE: -1G 5540 5 Q
NICHOLAS A. STREETER R.C.E. 70862 CITY ENGINE R.C.E. 51152 U