HomeMy WebLinkAbout4866-15CONSTRUCTIONNOTES
EX/STING SIX (6) 1 1/2" HIGH DENS/TY POL YEINYLENE (HDPE) CONDU/TS.
EXISTING 2" CONDUIT.
EXIS77NG TRAFFIC SIGNAL CONTROLLER.
EXIS77NG P48 SPLICE VAULT PULL BOX.
EXIS77NG 6 PAIR 122 AWG COMMUNICA77ON IN7FRCONNECT CABLE TO REMAIN IN PLACE.
FURNISH AND INSTALL ONE (1) 96 -STRAND SMFO CABLE IN THE BLUE 1 1/2" HDPE CONDUIT.
WHERE CABLE PASSES THROUGH SPLICE VAULT. COIL 50' OF 96 -STRAND SMFO CABLE. SEE
SPECIAL PRO WSIONS FOR DETAILS.
FURNISH AND INSTALL 12-S77?AND SMFO CABLE IN EXIS77NG COMMUNICA TION CONDUIT.
FURNISH AND INSTALL WALL INTERCONNECT CENTER (WC) AND SPL/CE TRAY /N EXISTING TRAFFIC
CONTROLLER CAB/NET. INSTALL AND TERM/NATE 12-S77?AND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE.
FURNISH AND INSTALL SPLICE ENCLOSURE AND FUS/ON SPL/CE SIX (6) STRANDS OF 96 -STRAND
SMFO CABLE TO THE APPROPRIATE STRANDS OF 12-S77?AND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE. COIL MINIMUM OF 16' OF 12 -STRAND SMFO AND 50' OF 96 -STRAND SMFO CABLE FOR
SLACK /N SPLICE VAULT.
[1-2]
FURNISH AND INSTALL
FIBER OP77C MODEMS IN
TRAFFIC CONTROLLER CABINET. COMPLETE
CONNECTION BETWEEN
WIC, CON7ROLLER MODEM,
AND VIDEO DETECTION MODEM.
r.
~+ 1
CUR-
TO MUIRFIELD LN
ml
1 " = 20'
0 20 40 60
1, 492' TO SIERRA LAKES PKWY
AUTOCAD FlLENAME S:\TRAFFlC\Lauren\Summit Ave Fiber Installation\basemapAdwg