HomeMy WebLinkAbout4866-13'' I
r.1
1
•'
v
F-11
F2
F41
F-51
F
F7]
F81
F9]
n
12
CONSTRUCTIONNOTES
EXlS11NG SIX (6) 1 1/2" HIGH DENS/TY POL YElHYLENE (HDPE) CONDUITS
EXISTING 2" CONDUIT.
EXISTING TRAFFIC SIGNAL CONTROLLER.
EXISTING P48 PULL BOX.
EXISTING P48 SPLICE VAULT PULL BOX.
EXISTING 6 PAIR 122 A WG COMMUNICA TION INTERCONNECT CABLE TO REMAIN IN PLACE.
FURNISH AND INSTALL ONE (1) 96 -STRAND SMFO CABLE IN THE BLUE 1 1/2'" HDPE CONDUIT.
WHERE CABLE PASSES THROUGH SPLICE VAULT COIL 50' OF 96 -STRAND SMFO CABLE. SEE
SPECIAL PRO WSIONS FOR DETAILS.
FURNISH AND INSTALL 12-S77?AND SMFO CABLE IN EXISTING COMMUNICA 77ON CONDUIT.
FURNISH AND INSTALL WALL INTERCONNECT CENTER (WIC) AND SPLICE TRA Y IN EXISTING TRAFFIC
CONTROLLER CABINET. INSTALL AND TERM/NA 7F 12-S77?AND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE.
FURNISH AND INSTALL SPL/CE ENCLOSURE AND FUS/ON SPL/CE SIX (6) STRANDS OF 96 -STRAND TO KN
SMFO CABLE TO THE APPROPRIATE STRANDS OF 12 -STRAND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE. COIL MINIMUM OF 16' OF 12 -STRAND SMFO AND 50' OF 96 -STRAND SMFO CABLE FOR
SLACK /N SPL/CE VAULT.
FURNISH AND INSTALL FIBER OP77C MODEMS IN TRAFFIC CONTROLLER CABINET. COMPLETE
CONNECTION BETWEEN WIC, CONTROLLER MODEM, AND I//DEO DETECTION MODEM.
s
i" — 7 n'
2,169" TO MUNFIRD LN
AUTOCAD MENAME: S:\TRAFFlC\Lauren\Summit Ave Fiber Installation\bosemopkdwg