HomeMy WebLinkAbout4866-12v
CONSTRUCTIONNOTES
F1 EX/517NG SIX (6) 1 1/2" HIGH DENS/TY POLYETHYLENE (HDPE) CONDUITS.
F2-1 EX/SANG 2" CONDUIT.
EX/SUNG PULL BOX (16 OR 16'E).
174] EX/SUNG TRAFFIC SIGNAL CONTROLLER.
F5] EX/SANG P48 PULL BOX.
F61 EXlS71NG P48 SPL/CE VAULT PULL BOX.
F7] EX/SUNG 6 PAIR X22 AWG COMMUNlCA710N INTERCONNECT CABLE TO REMAIN /N PLACE.
�8 FURNISH AND INSTALL ONE (1) 96 -STRAND SMFO CABLE IN THE BLUE 1 1/2" HDPE CONDUIT.
WHERE CABLE PASSES THROUGH SPL/CE VAULT, COIL 50' OF 96-S77?AND SMFO CABLE. SEE
SPEC/AL PRODS/ONS FOR DETAILS.
[-9] FURN/SH AND INSTALL 12 -STRAND SMFO CABLE /N EXlS17NG CDMMUN/CA LION CONDUIT.
Fl -0] FURNISH AND INSTALL WALL INTERCONNECT CENTER (WIC) AND SPL/CE TRA Y IN EXlS17NG TRAFFIC
CONTROLLER CAB/NET. INSTALL AND 1FRM/NA 7E 12 -STRAND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE.
F111 FURNISH AND INSTALL SPL/CE ENCLOSURE AND FUS/ON SPL/CE SIX (6) STRANDS OF 96 -STRAND
SMFO CABLE TO THE APPROPRIATE STRANDS OF 12-S77?AND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE. COIL MIN/MUM OF 16' OF 12 -STRAND SMFD AND 50' OF 96-S77?AND SMFO CABLE FOR
SLACK IN SPLICE VAULT.
n12 FURNISH AND INSTALL FIRER OP17C MODEMS /N TRAFFIC CONTROLLER CAB/NET. COMPLETE
CONNECAON BETWEEN WIC, CONTROLLER MODEM, AND NDEO DETECAON MODEM.
r.
r fI,
w
TO L YTLE CREEK RD
SUMMIT
K3
D
m
1"=20'
20 10 0 20 40 60
2, 625' TO Cl TRUS A VE
AUTOCAD FILENAME: S:\TRAFFIC\Lauren\Summit Ave Fiber Installation\basemapA dwg
�
O
9
K3
D
m
1"=20'
20 10 0 20 40 60
2, 625' TO Cl TRUS A VE
AUTOCAD FILENAME: S:\TRAFFIC\Lauren\Summit Ave Fiber Installation\basemapA dwg