HomeMy WebLinkAbout4866-10,
,
,
,
lk
CONSTRUCTIONNOTESpl,
F-11 EX/SANG SIX (6) 1 1/2" HIGH DENS/N POLYETHYLENE (HOPE) CONDUITS: O
F-21 EX/STING 2" CONDUIT. � O
FJJ EXISTING PULL BOX (16 OR f6EJ.
[-4] EXlS11NG TRAFFIC SIGNAL CONTROLLERR,
Q EXlS11NG P48 SPLICE VAULT PULL BOX.
F-7] EX/SANG 6 PA IR #22 AWG COMMUN/CA710N INTERCONNECT CABLE TO REMA/N /N PLACE.
F-81 FURNISH AND INSTALL ONE (1) 96 -STRAND SMFO CABLE IN THE BLUE 1 1/2" HDPE CONDUIT.
WHERE CABLE PASSES THROUGH SPL/CE VAULT, COIL 50' OF 96-S7RAN0 SMFO CABLE. SEE
SPEC/AL PROMS/ONS FOR DETAILS.
[-9] FURNISH AND INSTALL 12 -STRAND SMFO CABLE /N EXlS77NG COMMUN/CA AON CONDU/T.
F101 FURNISH AND INS TALL WALL /NTERCONNECT CENTER (WIC) AND SPLICE TRA Y /N EX/S71NG 7RAFF/C
CONTROLLER CABINET. INSTALL AND TERM/NATE 12 -STRAND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE.
Fl 1] FURNISH AND INSTALL SPL/CE ENCLOSURE AND FUS/ON SPLICE SIX (6) STRANDS OF 96 -STRAND
SMFO CABLE TO THE APPROPRIATE STRANDS OF 12-S77?AND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE. COIL MINIMUM OF 16' OF 12-S7R4ND SMFO AND 50' OF 96 -STRAND SMFO CABLE FOR
SLACK IN SPL/CE VAULT.
12 FURNISH AND INSTALL F/BER OPAC MODEMS /N TRAFFIC CONTROLLER CAB/NET. COMPLETE
CONNECT/ON BETWEEN WIC, CONTROLLER MODEM, AND W0E0 DETECAON MODEM.
R ►1 ,
►
w +1
TO B,
= 20'
20 40 60
f' TO L YTLE CREEK RD
T AVE
MOW RUD AW-- S-\UWM\Lwren\Siunmit Ave Fber Installation\basemopkdwg