HomeMy WebLinkAbout4866-8. 0
.. .
v
m
r • 1 1
CONSTRUCTIONNOTES
EXIS77NG SIX (6) 1 1/2" HIGH DENS/TY POL METHYLENE (HDPE) CONDUITS
EXISTING 2'r CONDUIT.
EXISTING TRAFFIC SIGNAL CONTROLLER.
EX/S77NG P48 SPLICE VAULT PULL BOX.
EXIS77NG 6 PAIR 122 A WG COMMUNICA TION IN7FRCONNECT CABLE TO REMAIN IN PLACE.
FURNISH AND INSTALL ONE (1) 96-S7RAND SMFO CABLE IN THE BLUE 1 1/2" HDPE CONDUIT.
WHERE CABLE PASSES THROUGH SPLICE VAULT, COIL 50' OF 96-S77?AN0 SMFO CABLE. SEE
SPECIAL PROW9SIONS FOR DETAILS.
FURNISH AND INSTALL 12 -STRAND SMFO CABLE IN EXIS77NG COMMUNICA TION CONDUIT.
FURNISH AND INSTALL WALL INTERCONNECT CENTER (WIC) AND SPLICE IRA Y IN EXIS77NG TRAFFIC
CONTROLLER CABINET. INSTALL AND 7FRM/NA 7F 12 -STRAND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE.
1"=20'
20 10 0 20 40 60
' Tp BEECH AVE
3Z8
[-I1 FURNISH AND INSTALL SPL/CE ENCLOSURE AND FUS/ON SPL/CE SIX (6) STRANDS OF 96 -STRAND
SMFO CABLE TO THE APPROPR/ATf STRANDS OF 12 -STRAND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE: COIL MINIMUM OF 16' OF 12 -STRAND SMFO AND 50' OF 96 -STRAND SMFO CABLE FOR
SLACK. /N SPLICE VAULT. M
EF121 FURN/SH AND /NSTALL F/BER OP11C MODEMS IN TRAFFIC CONTROLLER CAB/NET. COMPLETE
CONNECnON BEIWEEN WIC CONTROLLER MODEM AND l�DEO DETECnON MODEM TO SAN SEI/AINE R�
AUTOCAD FLLENAME S:\TRAFFIC\Loursn\Summit Ave Fier Installation\basemapkdwg