HomeMy WebLinkAbout4866-4,
,
.,I
CONSTRUCTIONNOTES
!.I.$,
F-11 EX/S71NG SlX (6) 1 1/2" HIGH DENS/TY POL METHYLENE (HDPE CONDUITS.
F21 EX/SANG 2" CONDUIT.
F41 EX/S17NG TRAFFIC SIGNAL CONTROLLER.
R,5 EXlS77NG P48 PULL BOX.
F6 EX/SUNG P48 SPLICE VA UL T PULL BOX.
�7 EX/SUNG 6 PAIR 122 AWG COMMUN/CA 110N /NTERCONNECT CABLE TO REMAIN /N PLACE.
F81 FURNISH AND INSTALL ONE (1) 96 -STRAND SMFO CABLE /N THE BLUE 1 1/2" HDPE CONDO/T.
WHERE CABLE PASSES THROUGH SPL/CE VAULT, COIL 50' OF 96-S77?AND SMFO CABLE. SEE
SPEC/AL PROWS/ONS FOR DETAILS.
F,91 FURNISH AND INSTALL 12 -STRAND SMFO CABLE /N EX/SUNG COMMON/CA 170N CONDUIT.
Fl-ol FURNISH AND INS TALL WALL /NTERCONNECT CENTER (WC) AND SPL /CE TRA Y/N EX/SUNG 7RAFF/C
CONTROLLER CAB/NET. INSTALL AND TERM/NATE 12 -STRAND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE.
F111 FURNISH AND INSTALL SPLICE SNCL OSURE AND FUS/ON SPLICE SIX (6) STRANDS OF 96 -STRAND
SMFO CABLE TO THE APPROPRIA TE STRANDS OF 12 -STRAND SMFO CABLE PER FIBER ASSIGNMENT
SCHEDULE. COIL MINIMUM OF 16' OF 12 -STRAND SMFO AND 50' OF 96 -STRAND SMFO CABLE FOR
SLACK IN SPLICE VA UL T.
F121 FURNISH AND INSTALL F/BER OP77C MODEMS IN TRAFFIC CONTROLLER CAB/NET. COMPLETE
CONNECTION BETWEEN WIC, CONTROLLER MODEM, AND i/IDEO DETECTION MODEM.
TO SOU 1
AUTOCAD FILENAME: S:\TRAFFIC\Lauren\Summit Ave Fiber Installation\basemopkdwg