HomeMy WebLinkAbout5512 1 of 2GENERAL NOTES FOR SEWER IMPROVEMENT PLANS
ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS
AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS
AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
1. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY
REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID
CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
2. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
3. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT,
ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO
WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909)
350-7610.
4. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE
STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE
CITY TRAFFIC ENGINEER.
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL
DEVICES AT ALL TIMES.
6. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR
GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
7. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING,
SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL
SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE
POTENTIAL EXISTS FOR GROUND MOVEMENT.
8. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR
THAT PURPOSE.
9. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT
UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
10. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS,
TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER,
SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS
NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
11. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY
AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND
WATER REQUIREMENTS.
12. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
13. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT
THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND
CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
14. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR
NOTIFICATION TO THE CITY ENGINEER.
15. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH
MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL
BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER
ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
16. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT
LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
17. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING,
AT ALL TIMES.
18. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR
PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
19. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
20. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL
REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
21. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON
INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING
IMPROVEMENTS.
22. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
23. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE
PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL
FOR TERMINAL CLEANOUT.
24. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.)
EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P.
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
26. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR
DEFLECTIONS IN ALIGNMENT.
27. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF
CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR
LOCATIONS SHOWN ON THE PLANS.
28. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY
ENGINEER.
29. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE.
WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET
INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
30. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL.
31. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL
NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
32. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND
APPROVED.
33. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
34. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
35. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING
CONTRACTOR UPON COMPLETION OF PAVING.
36. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER
TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
37. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE
RECORD DRAWINGS TO THE CITY ENGINEER.
BASIS OF BEARINGS-
THE BEARINGS SHOWN HEREON ARE BASED ON THE CALIFORNIA STATE PLANE
COORDINATE SYSTEM, ZONE 5, NORTH AMERICAN DATUM 1983, AS DETERMINED LOCALLY
BY THE LINE BETWEEN CSRC CORS STATIONS "SPMS" AND "CRFP", BOTH PUBLISHED ON
CSRC DATA SHEETS, BEING N 85'26'47.3026" E (2011.0 EPOCH).
BENCH MAW --
S
ARK=S. B. CO. PUBLIC WORKS BENCHMARK NO. "774"
P.K. NAIL IN S.C.E. TOWER BASE. AT ETIWANDA AND SLOVER AVENUES, 100 FEET WEST OF
ETIWANDA, 300 FEET SOUTH OF SLOVER, SECTION 29, T. 1 S., R. 6 W., IN NORTHEAST
CORNER OF CONCRETE TOWER BASE NO. 2 S.C.E. NO. 2 VISTA ETIWANDA, "T.B.M. 15" ON
CONCRETE TOWER BASE, SOUTHWEST CORNER OF AIRPORT DRIVE & ETIWANDA AVENUE.
ELEVATION = 969.8480 FEET
SEWER IMPROVEMENT PLAN
SLOVER DISTRIBUTION CENTER
SLOVER AVENUE AND JASMINE STREET
FONTANA, CALIFORNIA
R WT
I
- -�Ilp I!- • � • • \Ili � • it
0
CL L0 EXIST
R/W
a
SL 01/ER
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS,
OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED
TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN ON
THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND
RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN ON
THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT
THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE COUNTY OF SAN
BERNARDINO, THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
LEGEND
A. B.
-AGGREGATE BASE
H. P.
-HIGH POINT
A. C.
-ASPHALT CONCRETE
INV.
-INVERT
B.C.R.
-BEGINNING OF CURVE
M. H.
MANHOLE
BLDG
-BUILDING
N. G.
NATURAL GRADE
B.O.W.
-BOTTOM OF WALL
fl?
-PROPERTY LINE
B.W.
-BACK OF WALK
PB
-PULL BOX
C.L.F.
-CHAIN LINK FENCE
P. P.
-POWER POLE
CONC.
-CONCRETE
R/W
RIGHT OF WAY
C. F.
-CURB FACE
R. D.
-ROOF DRAIN
C. B.
-CATCH BASIN
TRANS PAD
-TRANSFORMER PAD
q
-CENTERLINE
T. B.
-TOP OF BERM
E.C.R.
-END OF CURVE
S =
SLOPE
EXIST.
-EXISTING
S. D.
STORM DRAIN
E. P.
-EDGE OF PAVEMENT
S. L.
-SIGHT LINE
F.G.
-FINISH GRADE
ST.LT.
-STREET LIGHT
F. F.
-FINISH FLOOR
T. G.
-TOP OF GRATE
F. L.
-FLOW LINE
T.C.
-TOP OF CURB
F. S.
-FINISH SURFACE
TOP
-TOP OF SLOPE
F. H.
-FIRE HYDRANT
TOE
TOE OF SLOPE
G.B.
-GRADE BREAK
WM
--WATER METER
H.C.
-HANDICAP
WV
WATER VALVE
BYO
BY OTHERS
TOLL FREE -800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV.
AVENUE-.0,��I''
IT
6.00
i
i
38.00 38.00
CENTERLINE
EX. MANHOLE
EX. 10" V.C.P. SS
5' W/O CENTERLINE
C) a
0
CV
LoC)
0
CV
00
CD
0
po
SHEET 2
INDEX MAP
SCALE: 1 " = 50'
SEWER CONSTRUCTION NOTES QUANTITY
0 INSTALL 8" (EXTRA STRENGTH) VCP SEWER LINE (BEDDING PER CITY OF FONTANA STD. 1008) 422 LF
2O CONSTRUCT 48" SEWER MANHOLE PER CITY OF FONTANA STD. 2001 2 EA
OINSTALL 6" VCP SEWER LATERAL PER CITY OF FONTANA STD. 2005 (COMMERCIAL)
3 AND MODIFIED SADDLE PER DETAIL HERE ON. 48 LF
4O INSTALL SEWER CLEAN-OUT AND CLEAN-OUT BOX PER CITY STD. 2005 & 2006. 1 EA
5O CONNECT TO EXISTING SEWER MANHOLE PER CITY OF FONTANA STANDARDS 1 EA
PREPARED FOR-
ALERE PROPERTY GROUP, LLC
100 BAYVIEW CIRCLE, SUITE 310
NEWPORT BEACH, CA 92660
PHONE: (949) 509-5000
FAX: (949) 509-5001
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
REVISION DESCRIPTION DATE 1 ENGR. CITY DATE STANDARDS IN EFFECT.
SOILS ENGINEER
SOUTHER CALIFORNIA GEOTECHNICAL
SOILS & GEOTECHNICAL CONSULTANTS
22885 SAVI RANCH PARKWAY SUITE 'E'
YORBA LINDA, CA. 92887
PHONE:�71
714) 685-1115
FAX: 4) 685-1118
4TH ST
AIRPOR
SAN BERNARDINO
A VE
15
W
DR Q
'
SL OVER A VE
Z
TITLE SHEET - CONSTRUCTION
NOTES &
QUANTITY ESTIMATES
2
W
STREET -
SEWER PLAN AND PROFILE
0 FESS/ONq
W
CITY OF FONTANA, CALIFORNIA
�
STFFy�
VICINITY MAP
N.T.S.
UTILITY CONTACTS
SAN BERNARDINO COUNTY FLOOD CONTROL
825 E. THIRD STREET, ROOM 140
SAN BERNARDINO, CA 92415-0835
PHONE: (909) 387-8256
ATTN: TOM WILLIAMS
FONTANA WATER COMPANY
15966 ARROW ROUTE
FONTANA, CA 92355
PHONE: (909) 822-2201
ATTN: BRENDA FOWLER
SOUTHERN CALIFORNIA GAS COMPANY
1981 W. LUGONIA AVE.
REDLANDS, CA
PHONE: (909) 335-7965
ATTN: ED SANTILLAN
AT&T
1265 VAN BUREN ST. #180
ANAHEIM, CA 92807
PHONE: (714) 666-5614
ATTN: LEE QUEST
SOUTHERN CALIFORNIA EDISON
7951 REDWOOD AVENUE
FONTANA, CA 92336
PHONE: (909) 549-5345
ATTN: JEFF HUDSON
TIME WARNER
17777 CENTER COURT DR. 8TH FLOOR
CERRITOS, CA 90703
PHONE: (562) 677-0263
ATTN: JOHN CHRISTIANSEN
FONTANA UNITED SCHOOL DISTRICT
9680 CITRUS AVENUE
FONTANA, CA 92335
PHONE: (909) 357-5000 X 29455
ATTN: SHERRI WHITTEN
INLAND EMPIRE UTILITY AGENCY
(FOR SEWER)
6075 KIMBALL AVENUE
CHINO, CA 91708
PHONE: (909) 993-1696
ATTN: LIZA MUNOZ
%il ET INDEX
WD/D#6836C375516 DR
I
TITLE SHEET - CONSTRUCTION
NOTES &
QUANTITY ESTIMATES
2
SLOVER AVENUE AND JASMINE
STREET -
SEWER PLAN AND PROFILE
WD/D#6836C375516 DR
15-020
0,
0 FESS/ONq
Prepared Under The Supervision of
CITY OF FONTANA, CALIFORNIA
v
STFFy�
Thieves Engineering, lrlc.
s
"
SEWER IMPROVEMENT PLAN
i
CIVIL ENGINEERING • LAND SURVEWNG
14349 FIRESTONE BOULEVARD
r
LA MIRADA, CALIFORNIA 90638
DRAWN BY:
GP
13032 SLOVER AVENUE
SCALE:
AS SHOWN
* R.C.E. N0. 56155 r *
PH.(714J521-4811 FAX(714)521-4173
SLOVER DISTRIBUTION CENTER
m s
DESIGNED BY:
DATE:
sp Exp 12-31-16 Q
TITLE SHEET
-3r CIV 1� ��
voqL
GP
TRUCTION TES & QUANTITY ESTIMATES
°'
CHECKED BY:
A P ED /
.
3l /�
DRAWING NO.:X30
O
CA�
te
REINHARD STEN L RCE NO. 56155
MR
DATE:
5512