Loading...
HomeMy WebLinkAbout5469-1CONDUCTOR SCHEDULE L EXISTING PHASE DIAGRAM AWG. P S E PHASES Q Q Q Q Q Q Q Q 12 WIRE CONDUCTOR CABLE 3WIRE CONDUCTOR CABLE 1 02, 03, 05, 02P, 08PPB 07 1 08 SIG. 35' - LUM. 15' 15' H.P.S.V. 250 W 250 W TYPE B B PHASEI 8 2 QUAD S W 2 07, 08, 08P, 02PPB - MESSAGE Cypress Ave - A B EXISTING EXISTING - F OF CA 3 4 5 6 61A-5-100 15TS 26A-4-100 1A 35' 30' 35' 10' 3 04, 05, 07, 04P, 02PPB 2 B B B B 2 4 4 6 W N N E 2 MAS, SV -1-T SV -2-T MAS, SV -1-T TV -2-T SP -1-T SP -1-T SP -1-T SP -1-T 4 2 6 4 Valley Blvd - Cypress Ave - 4 01, 02, 03, 02P, 04PPB 7 61-5-100(N) 30'(N) 60'(N) �c 15'(N) 250 W(N) 5 01, 06,06P,04PPB - _- -1 1 1 Valley Bivd(R) ' 14 (N) � 7 (N) CANTILEVER SIGN ARM (N) F=18', F1=36 6 03, 04, 05, 04P, 06PPB 10 R - i... - - B(R) 8 S(R) TV-2-T(R) 7 03, 08,08P,06PPB - 14'(N) 4'(N)s 8 05, 06, 06P, 08PPB TOTAL CABLES 2 1 4 2 5 3 7 4 1 1 3 2 4 3 1 8 #10 1 LUMINAIRE 2 2 2 2 2 2 2 - OPTICOM CABLE (M-138) 1 1 2 2 - 1 1 4 01 - - - - - - 2 2 TYPE B DETECTOR LEAD-IN CABLE 02 - 4 4 4 - - - 4 03 - - - - 4 4 4 4 04 - _ - 5 - - - 5 05 - 2 2 2 - - - 2 06 - - - - - - 4 4 07 - - - 2 - - - 2 08 - - - - 4 4 4 4 TOTAL - 6 6 13 8 8 14 27 CONDUIT SIZES (INCHES) 3"(E) 3"(E) 3"(E) -3"(E) 3"(E) 3"(E) 4"J2-4" PERCENT FILL 117.5% 38.8%148.6%135.4%117.3% 33.9% 28.1%136.-971, ALL WNUUI15 & CONDUCTORS ARE NEW, EXCEPT AS NOTED: (E)=EXISTING. CONDUCTOR SCHEDULE IS FURNISHED AS AN INSTALLATION GUIDE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE CORRECT CONDUCTORS REQUIRED FOR THE INTENDED OPERATIONS. EX. R/W SIDEWALK GENERAL NOTES: 1. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL CONFORM TO THESE PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE CITY'S SPECIAL PROVISIONS, SECTION E, THE STANDARD PLANS AND SPECIFICATIONS OF THE STATE OF CALIFORNIA, DATED 2010, AND THE CALIFORNIA MANUAL OF TRAFFIC CONTROL DEVICES, DATED 2014. 2. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 3. CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT ANY CITY FURNISHED OR PROVIDED AS NOTED IN SECTION E. 4. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING FACILITIES WITHIN THE AREA OF CONSTRUCTION. THE CITY ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO COMMENCING WORK. CONTRACTOR SHALL RELOCATE AND/OR REPLACE ANY LANDSCAPING OR SPRINKLERS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURVEY MONUMENTS OR MARKERS DURING CONSTRUCTION. 6. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 3" RIGID METAL UNLESS OTHERWISE SHOWN. 7. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES & UTILIZE PEDESTRIAN COUNTDOWN TIMERS PER SPECIAL PROVISIONS. 8. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW CONSTRUCTION. 9. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND SECTION E. 10. CONTROLLER AND SERVICE CABINETS SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. CONTRACTOR SHALL MODIFY SPRINKLERS SYSTEMS AS NECESSARY. 11. CONTRACTOR SHALL INSTALL CITY -SUPPLIED REINFORCING CABLES AND ASSOCIATED HARDWARE (2 PER SIGN) ON OVERHEAD REFLECTIVE STREET NAME SIGNS IN ACCORDANCE WITH CITY DESIGN STANDARD 4005. 12. THE CONTRACTOR SHALL REPAIR/REPLACE ANY AND ALL DAMAGED LANDSCAPING, IRRIGATION, SIDEWALK, PAVEMENT OR ROADWAY STRIPING TO THE SATISFACTION OF THE ENGINEER. 13. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS FOR THIS PROJECT. CALTRAN S STD. NOTES: AB ABANDON. IF APPLIED TO CONDUIT, REMOVE CONDUCTORS. BC INSTALL PULL BOX IN EXISTING CONDUIT RUN. CC REMOVE EXISTING CONDUCTORS. CONNECT NEW AND EXISTINI_ CONDUIT. PULL BACK IN EXISTING CONDUCTORS. RE -CONNECT IN CABINET. RC EQUIPMENT OR MATERIAL TO BE REMOVED AND BECOME THE PROPERTY OF THE CONTRACTOR. RL RELOCATE EQUIPMENT. RR REMOVE AND REUSE EQUIPMENT. RS REMOVE AND SALVAGE EQUIPMENT. SC SPLICE NEW TO EXISTING CONDUCTORS. CURB/GUTTER---- EX. URB/GUTTEREX. E/P 4 Q BOLB —� 01+06 02+05 03 04 OLA X\ R.S.N.S. ■ PLACEMENT OLA 1 REMARKS 07 1 08 OPERATION: OLA=02+05 OLB=03+08 CONSTRUCTIO — —� 7 - 225' TO 1-W-04 X -WALK I i 1 2-W-04 - EX. R/W EX. CURB/GUTTER LOOPS SC EX. R3 -7R EX. 2"C., REMOVE 2 -DLC, INSTALL 2 -DLC DETAIL "A" VALLEY CURB/GUTTER-\ EX. R/W N SIDEWALK PP#2254702E-= y EX. ...E P ... Ln EX. 6-1.5"C. C-, DUCTS, 6PR #19 SIC PULE SCHEDULE L CI 1 2 STANDARD ARMS X. LUMINAIRE PED PUSH BTN. SIGNAL MOUNTING PED. R.S.N.S. ■ PLACEMENT 41 REMARKS TYPE 24A-4-100 15TS HT. 35' 30' SIG. 35' - LUM. 15' 15' H.P.S.V. 250 W 250 W TYPE B B PHASEI 8 2 QUAD S W VEHICLE MAS, SV -1-T SV -2-T PED. SP -1-T SP -1-T PHASE 2 8 MESSAGE Cypress Ave - A B EXISTING EXISTING ' 2-E-08 F OF CA 3 4 5 6 61A-5-100 15TS 26A-4-100 1A 35' 30' 35' 10' 65' - - 15' 15' - 250 W 250 W 250 W - B B B B 2 4 4 6 W N N E 2 MAS, SV -1-T SV -2-T MAS, SV -1-T TV -2-T SP -1-T SP -1-T SP -1-T SP -1-T 4 2 6 4 Valley Blvd - Cypress Ave - EXISTING EXISTING EXISTING EXISTING 7 61-5-100(N) 30'(N) 60'(N) �c 15'(N) 250 W(N) B(N) 6 E(N) 3 MAS(N), SV-1-T(N) SP-1-T(N) 6 Valley Bivd(R) ' 14 (N) � 7 (N) CANTILEVER SIGN ARM (N) F=18', F1=36 8 Al 1-A(R) 1 rn, nnurur it r-__ 10 R - i... - - B(R) 8 S(R) TV-2-T(R) SP-1-T(R) 8 - 14'(N) 4'(N)s ,11 -9W I mLlI 1 10 LAFJ III\V, LAIiGr 1 MJ IVU ICU: `IV)=NLYY, kK)=KLLUGA IL * = STRAIGHT ARM ■ = CLAMP -ON CANTILEVER SIGN ARM 4.� 12" 1 40' 128' 10' 2"C., 12' 12' 12' 12' 15' EX. CURB/ w GUTTER INSTALL I J 2 -DLC z 3 I IW 04 EX. E/P YEX. R/W Q EX. R/W w z z SCALE 1" = 20' n N U TYPE 'E' X. 2"C., 6PR #19 SIC 06........ BO ULE VARD i� O1 EX. R/W EX. 2"C.1 EX. 2"C., REMOVE 2 -DLC, iol,- --- 5 O2 SC LOOPS RINSOALL 4 -DLC INSTALL 2 -DLC - L - �� CD i 02P SIDEWALK SC LOOPS Q; 05 Tjw� 62+03 ' L r08P 2 -W -07f- IAf 10 ,---r, -- -y 3-E-03 T - 1-E-03 T. VIP 07 /cj - 1 3-W-04 �I�II� EX. R73-3 ,04 C.I 4 -W -041L ' EX. CURB /GUTTER ' r — � I � EX. EVP t _ __ ... ,..: � ......., ... _...... _ `r' 5-W-04 , 1 11 DETAIL „B" 1 04I 03 EX. EVP EX. 2"C., - . REMOVE 3 -DLC 04+05 �Y INSTALL 3 -DLC 04 EX. R73-3 01 DETAIL „C„ 04 5 - - - j ; I +0 \ 06 ,. - - - - SIMULT. DETAIL "B" -TER (NO SCALE) EX. R26S(CA) EX. R/W 6\ 06P`� "' 1' -1' O EX. CURB/GUTTER EX. CURB/GUTTER O �� 01 / EX. R W X. 2 C., 6PR #19 SIC LOOPS SC EX. R3 -7R �>L- --- --- ------ -� EX. R W / 3 n�TAIL 5\ - TO JUNIPER/VALLEY "C" � _ � �� � ~� 1 �{ Q EX. 02P SIGNAL CABINET LOOPS SC 1 CONSTRUCTION NOTES• DETAIL "A" -)1,/ALL I = IU TOLL FREE 'qq=mw" 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT DETAIL "C" (NO SCALE) 2 --_-_ - _-_-_-_ _ _==_� 0 02+03 SC LOOPS ❑ RR EXISTING TYPE R CABINET AND ECONOLITE ASC/3-2100 CONTROLLER TO NEW FOUNDATION EX. 6-1.5"C. DUCTS, I _ j �`�` N / PER CITY SPECIFICATIONS. CONTRACTOR SHALL INSTALL ALL APPURTENANCES TO PROVIDE 1-6PR #19 SIC I DETAIL "C" THE INTENDED OPERATION PER THESE PLANS AND THE SPECIAL PROVISIONS. PP #4736010E ❑ FURNISH & INSTALL TYPE R CABINET FOUNDATION COMPLETE. RC EXISTING FOUNDATION AND EX. 6-1.5"C. DUCTS, I -'�� 1�-- �'� EX. R3 -7R CONDUITS COMPLETE. 1-6PR #19 SIC I "'0413❑ RR EXISTING TYPE III ELECTRICAL SERVICE CABINET TO NEW FOUNDATION. RC EXISTING i I CABINET FOUNDATION COMPLETE. COORDINATE RELOCATION WITH EDISON SERVICE PLANNER. ..1 I U' N, I I EX. 2"C., REMOVE 3 -DLC, M, INSTALL 3 -DLC ❑ RS EXISTING 29-5-100 SIGNAL STANDARD COMPLETE. RC N FOUNDATION COMPLETE. W I 25' 11' 11' 13'' < < ' 5 RR EXISTING 1-A SIGNAL STANDARD AND EQUIPMENTS TO NEW LOCATION. RC 5 14 12 I ❑ ❑ EXISTING SIGNAL nn� EX. CURB I EX. R/W ❑ GUTTER' '; / FOUNDATION COMPLETE. SEE POLE SCHEDULE® FOR LOCATION DETAIL. � � © RL EXISTING COMMUNICATIONS VAULT, INTERCONNECT CABLE, AND 6-1.5" C. DUCTS. N N I EX. CURB/GUTTER 7 RL EXISTING PULL BOX, INTERCONNECT CABLE, AND 2" CONDUIT. N3 EX. R/W ; -;' I I SC LOOPS E] RL EXISTING MAST ARM SIGN. CONTRACTOR TO FURNISH NEW MOUNTING HARDWARE. ____~--_ _ _______ _______ ❑9 RL EXISTING EVP TO NEW SIGNAL MAST ARM PER DETAIL "D". i < " 10 FURNISH & INSTALL 2"C., 2#8(SERVICE , AND 1 C:) ❑ ) #6(GROUND). N X 11 FURNISH & INSTALL 2"C., 2#1O(LUMINAIRE). 1 EX. 6-6PR#19 SIC . DUCTS, 12. SEE SIGNING AND STRIPING PLAN FOR MORE DETAIL. 1-6PR - TO SLOVER/CYPRESS -------------------- EX. 2"C., REMOVE 1 -DLC, EX. CURB/GUTTER INSTALL 1 -DLC Y-� SC LOOPS EX. R/W 41 ' V7' 1-S-02 52' 7' EX. CURB/GUTTER 105' EX. R/W REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. Q'�'pFESS/o/v SC LOOPS EX. R/W X. CURB/GU_ SIDEWALK Z DRAWN BY: ``' No. C 69921 m 41 Ac 350 Fac (909) 605-9311 I DESIGNED BY: DIAMOND BAR, CA 91765 www.advantec—usaxorn PKi sT9r CI V 0- 0��\ Date: 05/19/16 y ' 2-E-08 F OF CA I W 230' TO �y, X-WrLK ,�Ln 1-E-08 .. I 4 to I DETAIL "B" -TER (NO SCALE) EX. R26S(CA) EX. R/W 6\ 06P`� "' 1' -1' O EX. CURB/GUTTER EX. CURB/GUTTER O �� 01 / EX. R W X. 2 C., 6PR #19 SIC LOOPS SC EX. R3 -7R �>L- --- --- ------ -� EX. R W / 3 n�TAIL 5\ - TO JUNIPER/VALLEY "C" � _ � �� � ~� 1 �{ Q EX. 02P SIGNAL CABINET LOOPS SC 1 CONSTRUCTION NOTES• DETAIL "A" -)1,/ALL I = IU TOLL FREE 'qq=mw" 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT DETAIL "C" (NO SCALE) 2 --_-_ - _-_-_-_ _ _==_� 0 02+03 SC LOOPS ❑ RR EXISTING TYPE R CABINET AND ECONOLITE ASC/3-2100 CONTROLLER TO NEW FOUNDATION EX. 6-1.5"C. DUCTS, I _ j �`�` N / PER CITY SPECIFICATIONS. CONTRACTOR SHALL INSTALL ALL APPURTENANCES TO PROVIDE 1-6PR #19 SIC I DETAIL "C" THE INTENDED OPERATION PER THESE PLANS AND THE SPECIAL PROVISIONS. PP #4736010E ❑ FURNISH & INSTALL TYPE R CABINET FOUNDATION COMPLETE. RC EXISTING FOUNDATION AND EX. 6-1.5"C. DUCTS, I -'�� 1�-- �'� EX. R3 -7R CONDUITS COMPLETE. 1-6PR #19 SIC I "'0413❑ RR EXISTING TYPE III ELECTRICAL SERVICE CABINET TO NEW FOUNDATION. RC EXISTING i I CABINET FOUNDATION COMPLETE. COORDINATE RELOCATION WITH EDISON SERVICE PLANNER. ..1 I U' N, I I EX. 2"C., REMOVE 3 -DLC, M, INSTALL 3 -DLC ❑ RS EXISTING 29-5-100 SIGNAL STANDARD COMPLETE. RC N FOUNDATION COMPLETE. W I 25' 11' 11' 13'' < < ' 5 RR EXISTING 1-A SIGNAL STANDARD AND EQUIPMENTS TO NEW LOCATION. RC 5 14 12 I ❑ ❑ EXISTING SIGNAL nn� EX. CURB I EX. R/W ❑ GUTTER' '; / FOUNDATION COMPLETE. SEE POLE SCHEDULE® FOR LOCATION DETAIL. � � © RL EXISTING COMMUNICATIONS VAULT, INTERCONNECT CABLE, AND 6-1.5" C. DUCTS. N N I EX. CURB/GUTTER 7 RL EXISTING PULL BOX, INTERCONNECT CABLE, AND 2" CONDUIT. N3 EX. R/W ; -;' I I SC LOOPS E] RL EXISTING MAST ARM SIGN. CONTRACTOR TO FURNISH NEW MOUNTING HARDWARE. ____~--_ _ _______ _______ ❑9 RL EXISTING EVP TO NEW SIGNAL MAST ARM PER DETAIL "D". i < " 10 FURNISH & INSTALL 2"C., 2#8(SERVICE , AND 1 C:) ❑ ) #6(GROUND). N X 11 FURNISH & INSTALL 2"C., 2#1O(LUMINAIRE). 1 EX. 6-6PR#19 SIC . DUCTS, 12. SEE SIGNING AND STRIPING PLAN FOR MORE DETAIL. 1-6PR - TO SLOVER/CYPRESS -------------------- EX. 2"C., REMOVE 1 -DLC, EX. CURB/GUTTER INSTALL 1 -DLC Y-� SC LOOPS EX. R/W 41 ' V7' 1-S-02 52' 7' EX. CURB/GUTTER 105' EX. R/W REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. Q'�'pFESS/o/v Prepared Under The Supervision Of �o . ESp OS F� ADVANTEC Consulting Engineers Z DRAWN BY: ``' No. C 69921 m 21700 COPLEY DR. Tel: (909) 605-9300 Ac 350 Fac (909) 605-9311 DESIGNED BY: DIAMOND BAR, CA 91765 www.advantec—usaxorn PKi sT9r CI V 0- 0��\ Date: 05/19/16 CHECKED BY: F OF CA MARK J. ESPOSITO R.C.E. 69921 W 01 OR 05 02 OR 04 03 OR 05 A m i ' U o w B.C.R. B' I POLE LOCATION DETAIL U 7 EMERGENCY VEHICLE PRE-EMPTI❑N DETECTOR MOUNTING DETAIL DETAIL "D" (NO SCALE) OR X -WALK DETAIL "E" LOOP PLACEMENT & SAWCUT (SCALE: 1 "=20') TYPE 'E' 'E' 20 10 0 20 40 60 SCALE 1" = 20' CITY OF FONTANA, CALIFORNIA TRAFFIC SIGNAL MODIFICATION PLAN VALLEY BOULEVARD SCALE: AT As Noted CY RESS AVENUE DATE:05/19/2016 AP OVE @Y: DATE: DRAWING NO.: 1 tO CITY ENGINEER -R.051152 5469 1