Loading...
HomeMy WebLinkAbout5478-1SIERRA AV. / CB 0 -_ — -- ---- EX RJW----- ----w - APPROX. 900' FROM P48 PB AT NEW CONTROLLER TO EXISTING PB AND APPROX. 2100' SOUTH OF P48 AT BASELINE AVE. (SEE NOTE 7). 1 e _ E_X. Rl_W_ PROP. CURB &GUTTER CONDUCTOR SCHEDULE AWG SIZE OR CABLE TYPE POLE OR CIRCUIT POLE SCHEDULE z POLE DATA LUMINAIRE SIGNAL MOUNTING PED. PUSH BUTTON POLE LOCATION STREET NAME SIGN REMARKS N0. TYPE HEIGHT SIG. M.A. LUM M.A. L.E.D. VEHICLE MAST ARM PEDESTRIAN PHASE QUAD. A B C PHASE 5 PHASE 6 QO 29-5-100 30' 55' 15' 138W SV - I -T 3 MAS SP - I -fS 4 N 10' Ml 4' San Jacinto AVE 16800 F = 14, F = 5', F = 16' 1 AM AV p © I -A 10' - =1 Ap TV - I -T MMMMMMIA SP -I -CS 6 E 10' 4' MIAVIAVI © 19-3-100 30' 20' 15' 138W SV_ I MAS SP- 6 E 10' 4' Sierra AVE 7400 " 1 AM Ml AM O I -A 10' H Apv WAV PAV TV - I -T SP - I -CS 8 S 10' 4' O 29-5-100 30' 50' 15' 138W SV - I -T 3 MAS SP I CS 8 S 8' 4' San Jacinto AVE 16900 F = 16', F = 16' TYPE "B" DLC O I -A 10' TV - I -T SP - I -CS 2 W 8' 4' - - cr © 19-3-100 30' 20' 15' 138W SV - I -T I MAS SP - I -(S 2 W 8' 4' Sierra VE 7500 a "U' H I -A 10' TV - I -T SP - I -CS 4 N 8' 4' I CURB/BERM FLOW LINE EXACT POLE LOCATIONS TO BE DETERMINED BY ENGINEER IN THE FIELD OPTICOM CABLE OR EDGE OF SHOULDER ALL EQUIPMENT SHALL BE NEW ==mamma== w �\ W % FILLS ALL SIGNAL POLES SHALL BE DECORATIVE � m S O O /Gf z ~� W a BCR BEGIN CURB RETURN QUADRANT TYPICAL SIGNAL POLE PLACEMENT UNLESS DIMENSIONED ON PLANS - -- - - ------- �. �.... --.—. w— w■ aA-MMM Wu! IWO AM ruP I^LlP SIERRA AV. / CB 0 -_ — -- ---- EX RJW----- ----w - APPROX. 900' FROM P48 PB AT NEW CONTROLLER TO EXISTING PB AND APPROX. 2100' SOUTH OF P48 AT BASELINE AVE. (SEE NOTE 7). 1 e _ E_X. Rl_W_ PROP. CURB &GUTTER CONDUCTOR SCHEDULE AWG SIZE OR CABLE TYPE POLE OR CIRCUIT o -fl z PHASE 1 PHASE 2 PHASE 3 PHASE 4 7� i —.500100 /l/l/1104 0/1 00/ 40000, oo 3 z z CC PHASE 5 PHASE 6 PHASE 7 PHASE 8- MIAM PAM I AM p Apv FAV MIAV Ml AM I AM 1 AM AV p NA A =1 Ap MMMMMMIA MIAVIAVI Apv VA ME M p Apv I AM PAP V FAV 1 AM Ml AM VA Ml AM H Apv WAV PAV TYPE "B" DLC a a OPTICOM CABLE ==mamma== % FILLS ALL CABLES, CONDUCTORS, AND CONDUIT SHALL BE NEW. — I PROP. CURB & GUTTER STOP BAR OR LEADING EDGE OF CROSSWALK SCALE: 1" = 20' 0 10 20 40 60 80 NOTE: THIS PLAN IS ACCURATE FOR ELECTRICAL WORK ONLY. A EQUIPMENT LOCATIONS ■ Q PROP. CURB & GUTTER O Z K Va Q a a c PHASE DIAGRAM t7 o -fl z PHASE 1 PHASE 2 PHASE 3 PHASE 4 z z CC PHASE 5 PHASE 6 PHASE 7 PHASE 8- I1-04 PROP. BERM .4 L L, L-trlU 1LfUn11nU) 1" = 10'-0" SIERRA AV. 2" C, 246 (SIGNAL SERVICE, GFCI) SPECIAL BOLT DRILL & TAP 5/8" HOLE IN MAST ARM IODEL 711 iPTICAL DETECTOR SCREWS >T ARM _ .....P/CLAMP EVP DETECTOR MOUNTING DETAIL N.T.S. SIERRA EX. CURB &GUTTER _F PROP. CURB & GUTTER Ag EX. CURB &GUTTER CB EX. 6 1.5' C, W/ 96 -STRAND SMFO _ _ III IIS 8 9 11"A SEE SIGNAL CABINET DETAIL APPROX. 1200' FROM P48 PB AT NEW 7 9 CONTROLLER TO EXISTING PB TO REJOIN EXISING 96 -STRAND SMFO CABLE. 1 PROP. CURB & GUTTER TRAFFIC SIGNAL CONSTRUCTION NOTES GENERAL TRAFFIC SIGNAL NOTES 1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, LOOP . CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA DEPARTMENT OF ENGINEERING PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION DETECTORS, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED SHALL BE REQUESTED AT LEAST TWO DAYS 'PRIOR TO THE START OF ANY WORK IN PER CITY STANDARD DRAWING 4001. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC PUBLIC RIGHT-OF-WAY WITH IN THE CITY LIMITS. CALL (909) 350-7610. EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. 2. TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE FURNISH AND INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND THE CALIFORNIA EDISON COMPANY REQUIREMENTS. STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 (DATED 2010) AND STANDARD PLANS (DATED 2010), THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE CONTROL DEVICES FOR STREETS AND HIGHWAYS, 2014 EDITION. SERVICE WITH SCE PLANNING DEPARTMENT AT 909-357-6116. SEE GENERAL NOTE 5. 3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE AND C0 LOCATION OF ALL UTILITIES AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR I a. ® INSTALL CITY FURNISHED UNI—DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR APPROVED SHALL BEAR THE TOTAL EXPENSE OF ANY REPAIR OR REPLACEMENT OF ANY UTILITIES EQUAL) PER DETAIL ON THIS SHEET AND AS DIRECTED BY THE ENGINEER. DAMAGED BY HIS OPERATIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 2" C, I DLC 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 1 FURNISH AND INSTALL STREET NAME SIGN ON STRAIGHT ARM PER CITY STANDARD PLAN 4005. 4. ALL PULL BOXES SHALL BE No. 6 AND CONDUIT SHALL BE 3" RIGID METAL UNLESS OTHERWISE SHOWN. © FURNISH AND INSTALL SIGN (NOTED) ON SIGNAL MAST ARM PER CALTRANS STANDARD PLAN ES -7N DETAIL "U". 5. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH SOUTHERN CALIFORNIA EDISON COMPANY FOUR WEEKS IN ADVANCE OF NEED. DISCONNECT 96 STRAND SMFO CABLE FROM EXISTING SPLICE ENCLOSURE AND PULL CABLE OUT OF EXISTING 6. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT 6—PACK CONDUIT TO P48 PULLBOX APPROXIMATELY 2100' SOUTH. LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND SECTION E. 74,0100 ® FURNISH AND INSTALL SIX (6) NEW 1.5" HIGH DENSITY POLYETHYLENE (HDPE) CONDUITS. FURNISH AND 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND INSTALL P48 PULL BOXES AT A MAXIMUM OF 400' BETWEEN PULL BOXES. SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY REINSTALL EXISTING 96 STRAND SMFO CABLE IN NEW 6—PACK CONDUIT BACK TO EXISTING P48 PULLBOX AND SPRINKLER SYSTEM IF NECESSARY. 1" C, I DLC TERMINATE ALL 96 FIBERS TO EXISTING SPLICE ENCLOSURE. (INSTALL NEW SPLICE ENCLOSURE IF NECESSARY) g ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES & UTILIZE PEDESTRIAN 10 FURNISH AND INSTALL P48 PULL BOX WITH SPLIT LID. COUNTDOWN TIMERS PER SPECIAL PROVISIONS. ai jj FURNISH AND INSTALL 2" CONDUIT AND 12 STRAND S.M.F.O. CABLE. 10. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW CONSTRUCTION. CL FURNISH AND INSTALL SPLICE ENCLOSURE. FUSION SPLICE DESIGNATED FIBERS FROM EXISTING 96 -STRAND 11. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT 12 THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY S.M.F.O. TO 12 -STRAND S.M.F.O. PER SPLICE SCHEDULE. COIL AN ADDITIONAL 25' OF 12 -STRAND S.M.F.O. FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. CABLE IN THE P48 PULL BOX. 12. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR 13 TERMINATE DESIGNATED FIBERS FROM 12—STRAND S.M.F.O. CABLE TO WALL INTERCONNECT UNIT LOCATED POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. INSIDE SIGNAL CABINET. SPLICE SCHEDULE WILL BE PROVIDED BY CITY. FIBER OPTIC TERMINATIONS TO BE 13. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE COMPLETED IN A TIMELY MANNER IN ORDER TO KEEP FIBER OPTIC NETWORK DOWN TIME TO A MINIMUM. BORING METHOD, TRENCH REPAIRS SHALL BE PER CITY STANDARD, AND SPECIAL PROVISIONS, SECTION E. 14 FURNISH AND INSTALL DIMENSIONS BATTERY BACK UP UNIT PER MANUFACTURERS REQUIREMENTS. 14. AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF 15 RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTOCAD FILES TO CAP TENON FOR FUTURE SIGNAL HEAD. THE CITY ENGINEER.