Loading...
HomeMy WebLinkAbout5458-2AIR -QUALITY -MITIGATION -NOTES BACM AQ -1 • ALL CLEARING, GRADING, EARTH -MOVING, OR EXCAVATION ACTIVITIES SHALL CEASE WHEN WINDS EXCEED 25 MPH PER SCAQMD GUIDELINES IN ORDER TO LIMIT FUGITIVE DUST EMISSIONS. • THE CONTRACTOR SHALL ENSURE THAT ALL DISTURBED UNPAVED ROADS AND DISTURBED AREAS WITHIN THE PROJECT ARE WATERED AT LEAST THREE (3) TIMES DAILY DURING DRY WEATHER. WATERING, WITH COMPLETE COVERAGE OF DISTURBED AREAS, SHALL OCCUR AT LEAST THREE TIMES A DAY, PREFERABLY IN THE MID-MORNING, AFTERNOON, AND AFTER WORK IS DONE FOR THE DAY. • THE CONTRACTOR SHALL ENSURE THAT TRAFFIC SPEEDS ON UNPAVED ROADS AND PROJECT SITE AREAS ARE REDUCED TO 15 MILES PER HOUR OR LESS. BACM AQ -2 THE CALIFORNIA AIR RESOURCES BOARD, IN TITLE 13, CHAPTER 10, SECTION 2485, DIVISION 3 OF THE OF THE CALIFORNIA CODE OF REGULATIONS, IMPOSES A REQUIREMENT THAT HEAVY DUTY TRUCKS ACCESSING THE SITE SHALL NOT IDLE FOR GREATER THAN FIVE MINUTES AT ANY LOCATION. THIS MEASURE IS INTENDED TO APPLY TO CONSTRUCTION TRAFFIC. GRADING PLANS SHALL REFERENCE THAT A SIGN SHALL BE POSTED ON-SITE STATING THAT CONSTRUCTION WORKERS NEED TO SHUT OFF ENGINES AT OR BEFORE FIVE MINUTES OF IDLING (41). MM AQ -1 DURING GRADING ACTIVITY, THE CONTRACTOR SHALL ENSURE THAT ALL RUBBER TIRED DOZERS, SCRAPERS, AND GRADERS SHALL BE CAUFORNIA AIR RESOURCES BOARD (CARE) TIER 3 CERTIFIED OR BETTER. ADDITIONALLY, DURING GRADING ACTIVITY, THE CONTRACTOR SHALL ENSURE THE TOTAL HORSEPOWER -HOURS PER DAY FOR ALL EQUIPMENT SHALL NOT EXCEED 18,560 HORSEPOWER -HOURS PER DAY. MM AQ -2 IN ORDER TO REDUCE PRO ECT -RELATED AIR POLLUTANT AND GREENHOUSE GAS (GHG) EMISSIONS, AND PROMOTE SUSTAINABILITY THROUGH CONSERVATION OF ENERGY AND OTHER NATURAL RESOURCES, BUILDING AND SITE PLAN DESIGNS SHALL ENSURE THE PROJECT ENERGY EFFICIENCIES SURPASS (EXCEED) APPUCABLE (2014) CALIFORNIA TITLE 24 ENERGY EFFICIENCY STANDARDS BY A MINIMUM OF 5 PERCENT. VERIFICATION OF INCREASED ENERGY EFFICIENCIES SHALL BE DOCUMENTED IN TITLE 24 COMPLIANCE REPORTS PROVIDED BY THE APPLICANT, AND REVIEWED AND APPROVED BY THE CITY PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT. MM AQ -3 TO REDUCE ENERGY DEMAND ASSOCIATED WITH POTABLE WATER CONVEYANCE, THE PROJECT SHALL IMPLEMENT THE FOLLOWING: • U.S. EPA CERTIFIED WATERSENSE LABELED OR EQUIVALENT FAUCETS, HIGH -EFFICIENCY TOILETS (NETS), AND WATER -CONSERVING SHOWER HEADS • 4.2-1A: ALL CONSTRUCTION EQUIPMENT SHALL BE MAINTAINED IN GOOD OPERATION CONDITION SO AS TO REDUCE EMISSIONS. THE CONSTRUCTION CONTRACTOR SHALL ENSURE THAT ALL CONSTRUCTION EQUIPMENT IS BEING PROPERLY SERVICED AND MAINTAINED AS PER THE MANUFACTURER'S SPECIFICATION. MAINTENANCE RECORDS SHALL BE AVAILABLE AT THE CONSTRUCTION SITE FOR CITY VERIFICATION. [GPEIR MM AQ -1] • 4.2-1B: PRIOR TO THE ISSUANCE OF ANY GRADING PERMITS, ALL APPLICANTS SHALL SUBMIT CONSTRUCTION PLANS TO THE CITY OF FONTANA DENOTING THE PROPOSED SCHEDULE AND PROJECTED EQUIPMENT USE. CONSTRUCTION CONTRACTORS SHALL PROVIDE EVIDENCE THAT LOW EMISSION MOBILE CONSTRUCTION EQUIPMENT WILL BE UTILIZED, OR THAT THOR USE WAS INVESTIGATED AND FOUND TO BE INFEASIBLE FOR THE PROJECT. CONTRACTORS SHALL ALSO CONFORM TO ANY CONSTRUCTION MEASURES IMPOSED BY THE SCAQMD AS WELL AS CITY PLANNING STAFF. [GPEIR MM AQ- 2] • 4.6-1C: ALL PAINTS AND COATINGS SHALL MEET OR EXCEED PERFORMANCE STANDARDS NOTED IN SCAQMD RULE 1113. [GPDR MM AQ -3] • 4.2-11): PROJECTS THAT RESULT IN THE CONSTRUCTION OF MORE THAN 19 SINGLE-FAMILY RESIDENTIAL UNITS, 40 MULTIFAMILY RESIDENTIAL UNITS, OR 45,000 SQUARE FEET OF RETAIL/COMMERCIAL/INDUSTRIAL SPACE SHALL BE REQUIRED TO APPLY PAINTS ETHER BY HAND OR HIGH VOLUME, LOW PRESSURE (HVLP) SPRAY. [GPEIR MM AQ -4] • 4.2-1E ALL ASPHALT SHALL MEET OR EXCEED PERFORMANCE STANDARDS NOTED IN SCAQMD RULE 110& [GPDR MM AQ -5] • 4.2-1F PRIOR TO THE ISSUANCE OF GRADING PERMITS OR APPROVAL OF GRADING PLANS FOR FUTURE DEVELOPMENT PROJECTS WITHIN THE ADDED AREA, FUTURE DEVELOPMENTS SHALL INCLUDE A DUST CONTROL PLAN AS PART OF THE CONSTRUCTION CONTRACT STANDARD SPECIFICATIONS. THE DUST CONTROL PLAN SHALL INCLUDE MEASURES TO MEET THE REQUIREMENTS OF SCAQMD RULES 402 AND 403. • 4.2-2A ALL LARGE-SCALE' PROJECT APPLICANTS SHALL PROVIDE INCENTIVES TO USE MASS TRANSIT INCLUDING THE PLACEMENT OF BUS STOP SHELTERS ALONG MAJOR THOROUGHFARES IF NOT SO EQUIPPED. (CITY STAFF SHALL DETERMINE WHAT DENOTES A 'LARGE-SCALE' PROJECT.) [GPER MM AQ -71 • 4.2-2B: ALL 'LARGE-SCALE' PROJECT APPLICANTS SHALL INCORPORATE A BIKE/WALKING PATH BETWEEN THESE SHELTERS, THE PROPOSED RESIDENTIAL AREAS, AND THE PROPOSED COMMERCIAL AREAS. THESE PATHS SHALL BE UT AND CONFIGURED SO AS TO AVOID POTENTIAL CONFLICT WITH ROADWAYS AND RAILROAD ACTIVITIES. [GPEIR MM AQ -81 • 4.2-2C: ALL INDUSTRIAL AND COMMERCIAL FACILITIES SHALL POST SIGNS REQUIRING THAT TRUCKS SHALL NOT BE LEFT IDLING FOR PROLONGED PERIODS PURSUANT TO TITLE 13 OF THE CAUFORNIA CODE OF REGULATIONS, SECTION 2485, WHICH LIMITS IDLE TIMES TO NOT MORE THAN FIVE MINUTES [GPER MM AQ -9] • 4.2-21): THE CITY SHALL REQUIRE THAT BOTH INDUSTRIAL AND COMMERCIAL USES DESIGNATE PREFERENTIAL PARKING FOR VANPOOLS. [GPEIR MM AQ -10] • 4.2-2E THE PROPOSED COMMERCIAL AND INDUSTRIAL AREAS SHALL INCORPORATE FOOD SERNCE. [GPDR MM AQ -11] • 4.2-2F: ALL INDUSTRIAL AND COMMERCIAL SITE TENANTS WITH 50 OR MORE EMPLOYEES SHALL BE REQUIRED TO POST BOTH BUS AND METROUNK SCHEDULES IN CONSPICUOUS AREAS. [GPEIR MM AQ -12] • 4.2-2G: ALL INDUSTRIAL AND COMMERCIAL SITE TENANTS WITH 50 OR MORE EMPLOYEES SHALL BE REQUESTED TO CONFIGURE THEIR OPERATING SCHEDULES AROUND THE METROUNK SCHEDULE TO THE EXTENT REASONABLY FEASIBLE. [GPEIR MM AQ -13] • 4.2-2H: ALL RESIDENTIAL AND COMMERCIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE HIGH EFFICIENCYAOW POLLUTING HEATING, AIR CONDITIONING, APPLIANCES, AND WATER HEATERS. [GPDR MM AQ -14] • 4.2-21: ALL RESIDENTIAL AND COMMERCIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE THERMAL PANE WINDOWS AND WEATHER-STRIPPING. [GPDR MM AQ -15] • 4.2-2J: ALL RESIDENTIAL, COMMERCIAL, AND INDUSTRIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE LIGHT COLORED ROOFING MATERIALS. [GPDR MM AQ -16] • 4.2-2K: PRIOR TO APPROVAL OF FUTURE DEVELOPMENT PROJECTS WITHIN THE 2010 ADDED AREA, THE CITY OF FONTANA REDEVELOPMENT AGENCY SHALL CONDUCT PROJECT -LEVEL ENVIRONMENTAL REVIEW TO DETERMINE POTENTIAL VEHICLE EMISSION IMPACTS ASSOCIATE) WITH THE PROJECT(S). MITIGATION MEASURES SHALL BE DEVELOPED FOR EACH PROJECT AS IT IS CONSIDERED TO MITIGATE POTENTIALLY SIGNIFICANT IMPACTS TO THE EXTENT FEASIBLE POTENTIAL MITIGATION MEASURES MAY REQUIRE THAT FACILITIES WITH OVER 250 EMPLOYEES (FULL OR PART-TIME EMPLOYEES AT A WORKSITE FOR A CONSECUTIVE SIX-MONTH PERIOD CALCULATED AS A MONTHLY AVERAGE), AS REQUIRED BY THE AIR QUALITY MANAGEMENT PLAN, IMPLEMENT TRANSPORTATION DEMAND MANAGEMENT (TDM) PROGRAMS 18" FINISH 8" CURB PER GRADE CITY OF FONTANA STANDARD PLANS STD. 1000 FS • aD LO • '. AC PAVING 8" PERVIOUS CONCRETE 36" DEEP MINIMUM CRUSHED WASHED STONE (1/2" TO 3/4" NOMINAL SIZE ROCK) PERMEABLE FILTER FABRIC PER SECTION 88-1.03 OF CALTRANS 24" STANDARD SPECIFICATIONS 12" COMPACTED NATIVE (959) n 8' CURB & 18' PERVIOUS GUTTER NOT TO SCALE Z Q t0 } Q�N 0311 Q 311 11 owW �� c00 Li1ob (V - - w �j SIA +O04 � MSN o� N U 3 rr N U 3 N U 3 FLS N U J N t(1 00 <L N N LJi LO 00 M O N M 0 0 78 Oi 06 ai Oi 78 6 00 78 O O 00 N04 N 00 0.97% - I - -7"'00 CONSTRUCT 6" AC PAVEMENT I` L) OVER NATIVE, JOIN EXIST. � 0 GRADE AT R/W ao O PROPERTY LINE DETAIL A SCALE: 1"=10' BENCH MARK: CITY OF FONTANA BENCHMARK NO. 289 O NGVD29, ELEVATION=1032.22' FOUND RAILROAD SPIKE IN POWER POLE, NE CORNER DC7A2a jaT CATAWBA AVENUE & SANTA ANA AVENUEA,A,.&IDAYS DIALWO WORKING BASIS OF BEARING: BEFORE BEFORE THE BEARINGS SHOWN HEREON ARE BASED ONYOU DIGYOU DIG THE CENTERLINE OF CATAWBA AVENUE BEING TOLL FREE 1-800-227-2601[ NORTH 00' 15' 00" EAST PER R.S.B. 79/56. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALER' FUTURE 5' E�� U) U- SIDEWALK I w O 00 0 0 Oi O I / NO. I REVISION DESCRIPTION RECORD ORAWWIN& (1020.14 EG) FUTURE 5' EXIST. R/W CONSTRUCT 6" AC PAVEMENT SIDEWALK OVER NATIVE, JOIN EXIST. GRADE AT R/W A ETAIL B 3 Ts�l7 DATE ENGR. I CITY DATE RECORD DRAWINGS 1 THESE RECORD DRAWINGSHAVE BEEN PREPARED. IN PART, ON THE BASIS OF INFORMATION CO:APILED AND FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE DOCUMENTS AS A RESULT THEREOF SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. Lu w uj w w N tun O' n 0 N Cq O O0 O EXIST. AC� I DRIVEWAY •�,. 11112-T A•■ A QROFESSlo; \l 416, Fy�I Q q•••c i NO. 33366 - EXPIRATION I* : 6-30-2016 : */ I1 JI9J . • CIVIL . •���Qi OF CAS\F�� SCALE: 1 "=10' EXIST. WLY EXIST R/W CL 33' 34' 11' 22' 30' 11' 11' 22' PAVEMENT REPLACEMENT LIMITS PER STORM DRAIN PLANS, DWG. NO. 5414 I 1.5%-2.7% 1.4 2.8�y EX. SW I V F EX. C&Gl1 (140 s CATAWBA AVENUE (COLLECTOR) - TYPICAL SECTION FROM STA 31+40.00 TO STA 36+68.59 HORIZ.: 1"=10', VERT.: 1"=2' EXIST. W'LY EXIST R/W CL 33' 34' 30' 11' 11' 11' 22' FUT. WIDENING 24' 9' PAVEMENT REPLACEMENT LIMITS PER STORM DRAIN PLANS, DWG. NO. 5414 2.8%_ _ 2.8%,� �I-T �- EDGE OF PAVEMENT-___ 9 CATAWBA AVENUE (COLLECTOR) - TYPICAL SECTION FROM STA 24+32.26 TO STA 31+40.00 HORIZ.: 1"=10', VERT.: 1"=2' PROP. S'LY R/W 6' I I 2X2% IL_ 1 I I I I I CONSTRUCT 6" AC PAVEMENT M i OVER NATIVE, JOIN EXIST. GRADE AT R/W PROPERTY LINE SIACIK [mms-I11C�L�;lI:1:Z'� EXIST S'LY R/W EXIST CL EXIST. PROP. E'LY E'LY R/W R/W I a'lI EXIST. PROP. E'LY E'LY R/W R/W I .• I 21' 12' 1 � fio SAWWT I I a I ww �-UMITS w x X I MiTs w I 24 3.1% ----_ EX. AC `EX. GROUND P.I.P. to SANTA ANA AVENUE (SECONDARY) - TYPICAL SECTION FROM STA 10+00.00 TO STA 16+60.04 HORIZ.: 1"=10', VERT.: 1"=2' T.I.=9.6 STREET CONSTRUCTION NOTES O CONSTRUCT 8" CONCRETE CURB AND 18" PERVIOUS GUTTER PER DETAIL ON SHEET Z SEE CITY OF FONTANA STD. NO. 1000 FOR NOTES 5 CONSTRUCT CONCRETE SIDEWALK PER CITY OF FONTANA STD. NO. 1006 9 CONSTRUCT OVER 12" MIN 95% COMPACTED NATIVE SUBGRADE PER CITY OF FONTANA STD. NO. 400 to CONSTRUC 6.5" MIN.AG PAI_WCAI OVER 12" MIN. 95% COMPACTED NATIVE SUBGRADE PER CITY OF FONTANA STD. N0. 400 t5 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY OF FONTANA STD. NO. 1002 32 CONSTRUCT RESIDENTIAL DRIVEWAY PER CITY OF FONTANA STD. NO. 1002 so SAWCUT AND REMOVE EXISTING AC PAVING 61 SAWCUT AND REMOVE EXISTING PCC CURB & GUTTER 7e RELOCATE EXIST. MAILBOX PER USPS STANDARDS too COLD PLANE EXISTING AC MINIMUM 0.15' DEPTH & AC OVERLAY TO MATCH EXISTING Huitt-Zollars, Inc. Ontario DRAWN BY: 3990 CONCOURS, SUITE 330 • ONTARIO, CALIFORNIA 91764 • (909) 941-7799 HZ STAFF DESIGNED BY: APPROVED BY MAURICE H. MURAD R.C.E. EXPIRES DATE DLW CHECKED BY: 33366 6-30-16 T$ / M.H.M. CITY OF FONTANA, CALIFORNIA 15971 SANTA ANA AVENUE CATAWBA & SANTA ANA AVENUE TYPICAL ,SECTIONS AND DETAILS t0 D BY: �• ENGINEER R.C.E. 51152 DATE: EXIST. N'LY SCALE: AS SHOWN DATE: 3/2016 DWG. NO.: 2 5458 5r I 61 I I o�� N (0 O) N ri 00 O) N I` n n + 00 O N iv v I 110& [GPDR MM AQ -5] • 4.2-1F PRIOR TO THE ISSUANCE OF GRADING PERMITS OR APPROVAL OF GRADING PLANS FOR FUTURE DEVELOPMENT PROJECTS WITHIN THE ADDED AREA, FUTURE DEVELOPMENTS SHALL INCLUDE A DUST CONTROL PLAN AS PART OF THE CONSTRUCTION CONTRACT STANDARD SPECIFICATIONS. THE DUST CONTROL PLAN SHALL INCLUDE MEASURES TO MEET THE REQUIREMENTS OF SCAQMD RULES 402 AND 403. • 4.2-2A ALL LARGE-SCALE' PROJECT APPLICANTS SHALL PROVIDE INCENTIVES TO USE MASS TRANSIT INCLUDING THE PLACEMENT OF BUS STOP SHELTERS ALONG MAJOR THOROUGHFARES IF NOT SO EQUIPPED. (CITY STAFF SHALL DETERMINE WHAT DENOTES A 'LARGE-SCALE' PROJECT.) [GPER MM AQ -71 • 4.2-2B: ALL 'LARGE-SCALE' PROJECT APPLICANTS SHALL INCORPORATE A BIKE/WALKING PATH BETWEEN THESE SHELTERS, THE PROPOSED RESIDENTIAL AREAS, AND THE PROPOSED COMMERCIAL AREAS. THESE PATHS SHALL BE UT AND CONFIGURED SO AS TO AVOID POTENTIAL CONFLICT WITH ROADWAYS AND RAILROAD ACTIVITIES. [GPEIR MM AQ -81 • 4.2-2C: ALL INDUSTRIAL AND COMMERCIAL FACILITIES SHALL POST SIGNS REQUIRING THAT TRUCKS SHALL NOT BE LEFT IDLING FOR PROLONGED PERIODS PURSUANT TO TITLE 13 OF THE CAUFORNIA CODE OF REGULATIONS, SECTION 2485, WHICH LIMITS IDLE TIMES TO NOT MORE THAN FIVE MINUTES [GPER MM AQ -9] • 4.2-21): THE CITY SHALL REQUIRE THAT BOTH INDUSTRIAL AND COMMERCIAL USES DESIGNATE PREFERENTIAL PARKING FOR VANPOOLS. [GPEIR MM AQ -10] • 4.2-2E THE PROPOSED COMMERCIAL AND INDUSTRIAL AREAS SHALL INCORPORATE FOOD SERNCE. [GPDR MM AQ -11] • 4.2-2F: ALL INDUSTRIAL AND COMMERCIAL SITE TENANTS WITH 50 OR MORE EMPLOYEES SHALL BE REQUIRED TO POST BOTH BUS AND METROUNK SCHEDULES IN CONSPICUOUS AREAS. [GPEIR MM AQ -12] • 4.2-2G: ALL INDUSTRIAL AND COMMERCIAL SITE TENANTS WITH 50 OR MORE EMPLOYEES SHALL BE REQUESTED TO CONFIGURE THEIR OPERATING SCHEDULES AROUND THE METROUNK SCHEDULE TO THE EXTENT REASONABLY FEASIBLE. [GPEIR MM AQ -13] • 4.2-2H: ALL RESIDENTIAL AND COMMERCIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE HIGH EFFICIENCYAOW POLLUTING HEATING, AIR CONDITIONING, APPLIANCES, AND WATER HEATERS. [GPDR MM AQ -14] • 4.2-21: ALL RESIDENTIAL AND COMMERCIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE THERMAL PANE WINDOWS AND WEATHER-STRIPPING. [GPDR MM AQ -15] • 4.2-2J: ALL RESIDENTIAL, COMMERCIAL, AND INDUSTRIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE LIGHT COLORED ROOFING MATERIALS. [GPDR MM AQ -16] • 4.2-2K: PRIOR TO APPROVAL OF FUTURE DEVELOPMENT PROJECTS WITHIN THE 2010 ADDED AREA, THE CITY OF FONTANA REDEVELOPMENT AGENCY SHALL CONDUCT PROJECT -LEVEL ENVIRONMENTAL REVIEW TO DETERMINE POTENTIAL VEHICLE EMISSION IMPACTS ASSOCIATE) WITH THE PROJECT(S). MITIGATION MEASURES SHALL BE DEVELOPED FOR EACH PROJECT AS IT IS CONSIDERED TO MITIGATE POTENTIALLY SIGNIFICANT IMPACTS TO THE EXTENT FEASIBLE POTENTIAL MITIGATION MEASURES MAY REQUIRE THAT FACILITIES WITH OVER 250 EMPLOYEES (FULL OR PART-TIME EMPLOYEES AT A WORKSITE FOR A CONSECUTIVE SIX-MONTH PERIOD CALCULATED AS A MONTHLY AVERAGE), AS REQUIRED BY THE AIR QUALITY MANAGEMENT PLAN, IMPLEMENT TRANSPORTATION DEMAND MANAGEMENT (TDM) PROGRAMS 18" FINISH 8" CURB PER GRADE CITY OF FONTANA STANDARD PLANS STD. 1000 FS • aD LO • '. AC PAVING 8" PERVIOUS CONCRETE 36" DEEP MINIMUM CRUSHED WASHED STONE (1/2" TO 3/4" NOMINAL SIZE ROCK) PERMEABLE FILTER FABRIC PER SECTION 88-1.03 OF CALTRANS 24" STANDARD SPECIFICATIONS 12" COMPACTED NATIVE (959) n 8' CURB & 18' PERVIOUS GUTTER NOT TO SCALE Z Q t0 } Q�N 0311 Q 311 11 owW �� c00 Li1ob (V - - w �j SIA +O04 � MSN o� N U 3 rr N U 3 N U 3 FLS N U J N t(1 00 <L N N LJi LO 00 M O N M 0 0 78 Oi 06 ai Oi 78 6 00 78 O O 00 N04 N 00 0.97% - I - -7"'00 CONSTRUCT 6" AC PAVEMENT I` L) OVER NATIVE, JOIN EXIST. � 0 GRADE AT R/W ao O PROPERTY LINE DETAIL A SCALE: 1"=10' BENCH MARK: CITY OF FONTANA BENCHMARK NO. 289 O NGVD29, ELEVATION=1032.22' FOUND RAILROAD SPIKE IN POWER POLE, NE CORNER DC7A2a jaT CATAWBA AVENUE & SANTA ANA AVENUEA,A,.&IDAYS DIALWO WORKING BASIS OF BEARING: BEFORE BEFORE THE BEARINGS SHOWN HEREON ARE BASED ONYOU DIGYOU DIG THE CENTERLINE OF CATAWBA AVENUE BEING TOLL FREE 1-800-227-2601[ NORTH 00' 15' 00" EAST PER R.S.B. 79/56. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALER' FUTURE 5' E�� U) U- SIDEWALK I w O 00 0 0 Oi O I / NO. I REVISION DESCRIPTION RECORD ORAWWIN& (1020.14 EG) FUTURE 5' EXIST. R/W CONSTRUCT 6" AC PAVEMENT SIDEWALK OVER NATIVE, JOIN EXIST. GRADE AT R/W A ETAIL B 3 Ts�l7 DATE ENGR. I CITY DATE RECORD DRAWINGS 1 THESE RECORD DRAWINGSHAVE BEEN PREPARED. IN PART, ON THE BASIS OF INFORMATION CO:APILED AND FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THESE DOCUMENTS AS A RESULT THEREOF SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. Lu w uj w w N tun O' n 0 N Cq O O0 O EXIST. AC� I DRIVEWAY •�,. 11112-T A•■ A QROFESSlo; \l 416, Fy�I Q q•••c i NO. 33366 - EXPIRATION I* : 6-30-2016 : */ I1 JI9J . • CIVIL . •���Qi OF CAS\F�� SCALE: 1 "=10' EXIST. WLY EXIST R/W CL 33' 34' 11' 22' 30' 11' 11' 22' PAVEMENT REPLACEMENT LIMITS PER STORM DRAIN PLANS, DWG. NO. 5414 I 1.5%-2.7% 1.4 2.8�y EX. SW I V F EX. C&Gl1 (140 s CATAWBA AVENUE (COLLECTOR) - TYPICAL SECTION FROM STA 31+40.00 TO STA 36+68.59 HORIZ.: 1"=10', VERT.: 1"=2' EXIST. W'LY EXIST R/W CL 33' 34' 30' 11' 11' 11' 22' FUT. WIDENING 24' 9' PAVEMENT REPLACEMENT LIMITS PER STORM DRAIN PLANS, DWG. NO. 5414 2.8%_ _ 2.8%,� �I-T �- EDGE OF PAVEMENT-___ 9 CATAWBA AVENUE (COLLECTOR) - TYPICAL SECTION FROM STA 24+32.26 TO STA 31+40.00 HORIZ.: 1"=10', VERT.: 1"=2' PROP. S'LY R/W 6' I I 2X2% IL_ 1 I I I I I CONSTRUCT 6" AC PAVEMENT M i OVER NATIVE, JOIN EXIST. GRADE AT R/W PROPERTY LINE SIACIK [mms-I11C�L�;lI:1:Z'� EXIST S'LY R/W EXIST CL EXIST. PROP. E'LY E'LY R/W R/W I a'lI EXIST. PROP. E'LY E'LY R/W R/W I .• I 21' 12' 1 � fio SAWWT I I a I ww �-UMITS w x X I MiTs w I 24 3.1% ----_ EX. AC `EX. GROUND P.I.P. to SANTA ANA AVENUE (SECONDARY) - TYPICAL SECTION FROM STA 10+00.00 TO STA 16+60.04 HORIZ.: 1"=10', VERT.: 1"=2' T.I.=9.6 STREET CONSTRUCTION NOTES O CONSTRUCT 8" CONCRETE CURB AND 18" PERVIOUS GUTTER PER DETAIL ON SHEET Z SEE CITY OF FONTANA STD. NO. 1000 FOR NOTES 5 CONSTRUCT CONCRETE SIDEWALK PER CITY OF FONTANA STD. NO. 1006 9 CONSTRUCT OVER 12" MIN 95% COMPACTED NATIVE SUBGRADE PER CITY OF FONTANA STD. NO. 400 to CONSTRUC 6.5" MIN.AG PAI_WCAI OVER 12" MIN. 95% COMPACTED NATIVE SUBGRADE PER CITY OF FONTANA STD. N0. 400 t5 CONSTRUCT COMMERCIAL DRIVEWAY PER CITY OF FONTANA STD. NO. 1002 32 CONSTRUCT RESIDENTIAL DRIVEWAY PER CITY OF FONTANA STD. NO. 1002 so SAWCUT AND REMOVE EXISTING AC PAVING 61 SAWCUT AND REMOVE EXISTING PCC CURB & GUTTER 7e RELOCATE EXIST. MAILBOX PER USPS STANDARDS too COLD PLANE EXISTING AC MINIMUM 0.15' DEPTH & AC OVERLAY TO MATCH EXISTING Huitt-Zollars, Inc. Ontario DRAWN BY: 3990 CONCOURS, SUITE 330 • ONTARIO, CALIFORNIA 91764 • (909) 941-7799 HZ STAFF DESIGNED BY: APPROVED BY MAURICE H. MURAD R.C.E. EXPIRES DATE DLW CHECKED BY: 33366 6-30-16 T$ / M.H.M. CITY OF FONTANA, CALIFORNIA 15971 SANTA ANA AVENUE CATAWBA & SANTA ANA AVENUE TYPICAL ,SECTIONS AND DETAILS t0 D BY: �• ENGINEER R.C.E. 51152 DATE: EXIST. N'LY SCALE: AS SHOWN DATE: 3/2016 DWG. NO.: 2 5458 5r