GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK-). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK, THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK, INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
Z THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OF GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS
THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES AND TO EXERCISE PROPER PRECAUTION TO
AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL
UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENTTIES
OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED
LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL N077FY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
I& THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DIST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED
DENSITY IS OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL
CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE,
SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE
VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE
ASTM DESIGNATION C700 FOR V.C.P.
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE
CITY ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO
ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY
ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACIU71ES
DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2Z MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE
GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE
LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF
THE SEWER LATERAL
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL 714E FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTIUTES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
DIC�LEKT
DIALTWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
raLL FREE I -SO 227-26Do
A PUBLIC SERVICE BY
UNDERGROUND SERVICE ALERT
BASIS OF BEARINGS
THE BEARINGS SHOWN HEREON ARE
BASED ON THE CENTERLINE OF
CATAWBA AVENUE BEING NORTH
00'15'00" EAST PER R.S.B. 79/56.
E ER IMPROVEMENT PLAN
LEGEND
- - -
EXISTING R/W
DESCRIPTION
PROPOSED R/W
- - - -
- - - -
LOT UNE
-
CENTER UNE
J�
FIRE HYDRANT
fl .........
PROPERTY LINE
R/W ..........
RIGHT OF WAY
(L .........
CENTERLINE
BOT. .......
BOTTOM
SD .......
STORM DRAIN
SMH .........
SEWER MANHOLE
STD .........
STANDARD
SEW .........
SEWER
TYP...........
TYPICAL
IMP...........
IMPROVEMENT
P.I.P.........
. PROTECT IN PLACE
DWG .........
DRAWING
EXIST..........
EXISTING
RW ..........
RECYCLED WATER
INV .........
INVERT OF PIPE
UT .........
UTILITY
CVWD .........
CUCAMONGA VALLEY
WATER DISTRICT
SPPWC.........
STANDARD PLANS FOR
PUBLIC WORKS CONSTRUCTION
PROPOSED STORM DRAIN
-
EXISTING SEWER
S
EXISTING WATER
W
RW
EXISTING RECYCLED WATER
- EXISTING STORM DRAIN
EXISTING GAS
G
EXISTING TELEPHONE
T
E
EXISTING ELECTRICAL
EASEMENT
NOTE:
���-�7�SANTA ANA�A�VENfUE
CITY OF FONTANA
SEWER CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
A. CONTRACTOR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
AFTER FINAL PAVING HAS BEEN INSTALLED.
O INSTALL 8" (EXTRA STRENGTH) VCP SEWER LINE (BEDDING PER CITY OF FONTANA STD. 1008) .....................1396 LF
sla INSTALL SEWER CLEANOUT PER CITY OF FONTANA STD. 2006 & 2009 .......................................................1 EA
s15 INSTALL 4' SEWER MANHOLE PER CITY OF FONTANA STD. 2001................................................................4 EA
ssaINSTALL 8" VCP PLUG....................................................................................................................1 EA
81ADJUST RIM TO GRADE AFTER FINAL PAVING IS INSTALLED PER CITY OF FONTANA STD. 2000 .........................4 EA
sas INSTALL 6" VCP SEWER LATERAL PER CITY OF FONTANA STD. 2009........................................................42 LF
sso TRENCH AND BEDDING PER CITY OF FONTANA STD. 1008...................................................................1412 LF
AIR -QUALITY -MITIGATION -NOTES
BACM AQ -1
• ALL CLEARING, GRADING, EARTH -MOVING, OR EXCAVATION ACTIVITIES SHALL CEASE WHEN WINDS
EXCEED 25 MPH PER SCAQMD GUIDELINES IN ORDER TO LIMIT FUGITIVE DUST EMISSIONS.
• THE CONTRACTOR SHALL ENSURE THAT ALL DISTURBED UNPAVED ROADS AND DISTURBED AREAS
WITHIN THE PROJECT ARE WATERED AT LEAST THREE (3) TIMES DAILY DURING DRY WEATHER.
WATERING, WITH COMPLETE COVERAGE OF DISTURBED AREAS, SHALL OCCUR AT LEAST THREE TIMES
A DAY, PREFERABLY IN THE MID-MORNING, AFTERNOON, AND AFTER WORK IS DONE FOR THE DAY.
• THE CONTRACTOR SHALL ENSURE THAT TRAFFIC SPEEDS ON UNPAVED ROADS AND PROJECT SITE
AREAS ARE REDUCED TO 15 MILES PER HOUR OR LESS.
BACM AQ -2
THE CALIFORNIA AIR RESOURCES BOARD, IN TITLE 13, CHAPTER 10, SECTION 2485, DIVISION 3 OF THE OF
THE CALIFORNIA CODE OF REGULATIONS, IMPOSES A REQUIREMENT THAT HEAVY DUTY TRUCKS ACCESSING
THE SITE SHALL NOT IDLE FOR GREATER THAN FIVE MINUTES AT ANY LOCATION. THIS MEASURE IS
INTENDED TO APPLY TO CONSTRUCTION TRAFFIC. GRADING PLANS SHALL REFERENCE THAT A SIGN SHALL
BE POSTED ON-SITE STATING THAT CONSTRUCTION WORKERS NEED TO SHUT OFF ENGINES AT OR BEFORE
FIVE MINUTES OF IDLING (41).
MM AQ -1
DURING GRADING ACTIVITY, THE CONTRACTOR SHALL ENSURE THAT ALL RUBBER TIRED DOZERS,
SCRAPERS, AND GRADERS SHALL BE CALIFORNIA AIR RESOURCES BOARD (CARB) TIER 3 CERTIFIED OR
BETTER. ADDITIONALLY, DURING GRADING ACTIVITY, THE CONTRACTOR SHALL ENSURE THE TOTAL
HORSEPOWER -HOURS PER DAY FOR ALL EQUIPMENT SHALL NOT EXCEED 18,560 HORSEPOWER -HOURS PER
DAY.
MM AQ -2
IN ORDER TO REDUCE PROJECT -RELATED AIR POLLUTANT AND GREENHOUSE GAS (GHG) EMISSIONS, AND
PROMOTE SUSTAINABILITY THROUGH CONSERVATION OF ENERGY AND OTHER NATURAL RESOURCES,
BUILDING AND SITE PLAN DESIGNS SHALL ENSURE THE PROJECT ENERGY EFFICIENCIES SURPASS (EXCEED)
APPLICABLE (2014) CALIFORNIA TITLE 24 ENERGY EFFICIENCY STANDARDS BY A MINIMUM OF 5 PERCENT.
VERIFICATION OF INCREASED ENERGY EFFICIENCIES SHALL BE DOCUMENTED IN TITLE 24 COMPLIANCE
REPORTS PROVIDED BY THE APPLICANT, AND REVIEWED AND APPROVED BY THE CITY PRIOR TO THE
ISSUANCE OF THE FIRST BUILDING PERMIT.
MMA -
TO REDUCE ENERGY DEMAND ASSOCIATED WITH POTABLE WATER CONVEYANCE, THE PROJECT SHALL
IMPLEMENT THE FOLLOWING:
• U.S. EPA CERTIFIED WATERSENSE LABELED OR EQUIVALENT FAUCETS, HIGH -EFFICIENCY TOILETS
(NETS), AND WATER -CONSERVING SHOWER HEADS.
NERAL EIR MITIGATION MEASURES FROM SWIP-SPECIFIC PLAN DRAFT ENVIRONMENTAL IMPACT REPOR
• 4.2-1A: ALL CONSTRUCTION EQUIPMENT SHALL BE MAINTAINED IN GOOD OPERATION CONDITION SO
AS TO REDUCE EMISSIONS. THE CONSTRUCTION CONTRACTOR SHALL ENSURE THAT ALL CONSTRUCTION
EQUIPMENT IS BEING PROPERLY SERVICED AND MAINTAINED AS PER THE MANUFACTURER'S
SPECIFICATION. MAINTENANCE RECORDS SHALL BE AVAILABLE AT THE CONSTRUCTION SITE FOR CITY
VERIFICATION. [GPEIR MM AQ -1]
• 4.2-16: PRIOR TO THE ISSUANCE OF ANY GRADING PERMITS, ALL APPLICANTS SHALL SUBMIT
CONSTRUCTION PLANS TO THE CITY OF FONTANA DENOTING THE PROPOSED SCHEDULE AND
PROJECTED EQUIPMENT USE. CONSTRUCTION CONTRACTORS SHALL PROVIDE EVIDENCE THAT LOW
EMISSION MOBILE CONSTRUCTION EQUIPMENT WILL BE UTILIZED, OR THAT THEIR USE WAS
INVESTIGATED AND FOUND TO BE INFEASIBLE FOR THE PROJECT. CONTRACTORS SHALL ALSO
CONFORM TO ANY CONSTRUCTION MEASURES IMPOSED BY THE SCAQMD AS WELL AS CITY PLANNING
STAFF. [GPEIR MM AQ- 2]
• 4.6-1C: ALL PAINTS AND COATINGS SHALL MEET OR EXCEED PERFORMANCE STANDARDS NOTED IN
SCAQMD RULE 1113. [GPEIR MM AQ -3]
• 4.2-1D: PROJECTS THAT RESULT IN THE CONSTRUCTION OF MORE THAN 19 SINGLE-FAMILY
RESIDENTIAL UNITS, 40 MULTIFAMILY RESIDENTIAL UNITS, OR 45,000 SQUARE FEET OF
RETAIL/COMMERCIAL/INDUSTRIAL SPACE SHALL BE REQUIRED TO APPLY PAINTS EITHER BY HAND OR
HIGH VOLUME, LOW PRESSURE (HVLP) SPRAY. [GPEIR MM AQ -4]
• 4.2-1E: ALL ASPHALT SHALL MEET OR EXCEED PERFORMANCE STANDARDS NOTED IN SCAQMD RULE
BENCHMARK 289 ELEV.1032.22
LOCATION: CITY OF FONTANA
FOUND RAILROAD SPIKE IN POWER
POLE #61319, NE CORNER CATAWBA
AVENUE & SANTA ANA AVENUE.
1 1 RaORD GRAwrNv
NO. I REVISION DESCRIPTION
C/(A//7 -)M. TZ5
DATE ENGR. CITY
1108. [GPEIR MM AQ -51
• 4.2-1F PRIOR TO THE ISSUANCE OF GRADING PERMITS OR APPROVAL OF GRADING PLANS FOR
FUTURE DEVELOPMENT PROJECTS WITHIN THE ADDED AREA FUTURE SHA DEVELOPMENTS IN A
E LL INCLUDE
DUST CONTROL PLAN AS PART OF THE CONSTRUCTION CONTRACT STANDARD SPECIFICATIONS. THE
DUST CONTROL PLAN SHALL INCLUDE MEASURES TO MEET THE REQUIREMENTS OF SCAQMD RULES
402 AND 403.
• 4.2-2A: ALL 'LARGE-SCALE' PROJECT APPLICANTS SHALL PROVIDE INCENTIVES TO USE MASS
TRANSIT INCLUDING THE PLACEMENT OF BUS STOP SHELTERS ALONG MAJOR THOROUGHFARES IF NOT
SO EQUIPPED. (CITY STAFF SHALL DETERMINE WHAT DENOTES A 'LARGE-SCALE' PROJECT.) [GPEIR
MM AQ -7]
• 4.2-29: ALL 'LARGE-SCALE' PROJECT APPLICANTS SHALL INCORPORATE A BIKE/WALKING PATH
BETWEEN THESE SHELTERS, THE PROPOSED RESIDENTIAL AREAS, AND THE PROPOSED COMMERCIAL
AREAS. THESE PATHS SHALL BE UT AND CONFIGURED SO AS TO AVOID POTENTIAL CONFLICT WITH
ROADWAYS AND RAILROAD ACTIVITIES. [GPEIR MM AQ -8]
• 4.2-2C: ALL INDUSTRIAL AND COMMERCIAL FACILITIES SHALL POST SIGNS K REQUIRING THAT TRUCKS
CS
SHALL NOT BE LEFT IDLING FOR PROLONGED PERIODS PURSUANT TO TITLE 13 OF THE CALIFORNIA
CODE OF REGULATIONS, SECTION 2485, WHICH LIMITS IDLE TIMES TO NOT MORE THAN FIVE MINUTES.
[GPEIR MM AQ -9]
• 4.2-21): THE CITY SHALL REQUIRE THAT BOTH INDUSTRIAL AND COMMERCIAL USES DESIGNATE
PREFERENTIAL PARKING FOR VANPOOLS. [GPEIR MM AQ -10]
• 4.2-2E: THE PROPOSED COMMERCIAL AND INDUSTRIAL AREAS SHALL INCORPORATE FOOD SERVICE.
[GPEIR MM AQ -11]
• 4.2-2F: ALL INDUSTRIAL AND COMMERCIAL SITE TENANTS WITH 50 OR MORE EMPLOYEES SHALL BE
REQUIRED TO POST BOTH BUS AND METROLINK SCHEDULES IN CONSPICUOUS AREAS. [GPEIR MM
AQ -12]
• 4.2-2G: ALL INDUSTRIAL AND COMMERCIAL SITE TENANTS WITH 50 OR MORE EMPLOYEES SHALL BE
REQUESTED TO CONFIGURE THEIR OPERATING SCHEDULES AROUND THE METROUNK SCHEDULE TO THE
EXTENT REASONABLY FEASIBLE. [GPEIR MM AQ -13]
• 4.2-2H: ALL RESIDENTIAL AND COMMERCIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE HIGH
EFFICIENCY/LOW POLLUTING HEATING, AIR CONDITIONING, APPUANCES, AND WATER HEATERS. [GPEIR
MM AQ -14]
• 4.2-21: ALL RESIDENTIAL AND COMMERCIAL STRUCTURES SHALL BE REQUIRED TO INCORPORATE
THERMAL PANE WINDOWS AND WEATHER-STRIPPING. [GPEIR MM AQ -15]
• 4.2-2J: ALL RESIDENTIAL, COMMERCIAL„ AND INDUSTRIAL STRUCTURES SHALL BE REQUIRED TO
INCORPORATE LIGHT COLORED ROOFING MATERIALS. [GPEIR MM AQ -16]
• 4.2-2K: PRIOR TO APPROVAL OF FUTURE DEVELOPMENT PROJECTS WITHIN THE 2010 ADDED AREA,
THE CITY OF FONTANA REDEVELOPMENT AGENCY SHALL CONDUCT PROJECT -LEVEL ENVIRONMENTAL
RENEW TO DETERMINE POTENTIAL VEHICLE EMISSION IMPACTS ASSOCIATED WITH THE PROJECT(S).
MITIGATION MEASURES SHALL BE DEVELOPED FOR EACH PROJECT AS IT IS CONSIDERED TO MITIGATE
POTENTIALLY SIGNIFICANT IMPACTS TO THE EXTENT FEASIBLE. POTENTIAL MITIGATION MEASURES MAY
REQUIRE THAT FACILITIES WITH OVER 250 EMPLOYEES (FULL OR PART-TIME EMPLOYEES AT A
WORKSITE FOR A CONSECUTIVE SIX-MONTH PERIOD CALCULATED AS A MONTHLY AVERAGE), AS
REQUIRED BY THE AIR QUAUTY MANAGEMENT PLAN, IMPLEMENT TRANSPORTATION DEMAND
MANAGEMENT (TDM) PROGRAMS.
i•ao.n
DATE
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
OQ0.0�65�rpv� .
.�F. OrhMY icy ��
o V512 t� ,
rq CIVIL
�"'t OF CAL�"?�/
UTILITY CONTACTS
ELECTRICITY TELEPHONE
SOUTHERN CALIFORNIA EDISON AT&T
7951 REDWOOD AVENUE 3939 E CORONADO STREET
FONTANA, CA 92336 ANAHEIM, CA 92807
(909) 357-6203 (714) 237-6155
WATER SEWER
FONTANA WATER CO. CITY OF FONTANA
15966 ARROW ROUTE 8353 SIERRA AVENUE
FONTANA, CALIFORNIA 92335 FONTANA, CA 92335
(909) 822-2201 (909) 350-6632
GAS CABLE
SOUTHERN CALIFORNIA GAS CO. TIME WARNER CABLE
1981 W. LUGONIA AVENUE 1500 AUTO CENTER DRIVE
REDLANDS, CA 92374 ONTARIO, CA 91761
(800) 427-2200 (800) 892-2253
CIVIL ENGINEER OWNER/DEVELOPER
HUITT-ZOLLARS, INC RIDGE DEVELOPMENT COMPANY
3990 CONCOURS, #330 2211 MICHELSON DRIVE SUITE 650
ONTARIO, CA. 91761 IRVINE, CA 92612
PHONE (909) 941-7799 PH: 949-751-5721
FAX (909) 941-7789 CONTACT: DENNIS RICE
CONTACT: MAURICE MURAD
o _ t
SH EET 2
Emm
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED. IN
PART, ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO THESE DOCUMENTS
AS A RESULT THEREOF.
SOILS ENGINEER/GEOTECH
SOUTHERN CALIFORNIA GEOTECHNICAL, INC.
22885 SAVI RANCH PARKWAY, SUITE E
YORBA LINDA, CA 92887
PHONE (714) 685-1115
FAX (714) 685-1118
CONTACT. JOHN SEMINARA
SHEET 3
�i
CATAflB� AVENUE
J
�I
SHEET INDEX MAP
SCALE. 1"=500'
SHEET INDEX
SHT NO.
DESCRIPTION
1
TITLE SHEET
2
CATAWBA AVENUE STA. 15+44.30 TO 22+50.00
3
CATAWBA AVENUE STA. 22+50.00 TO 29+56.00
NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS
ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE. THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PR07ECT THE UTILITY LINES SHOWN ON THESE DRAWINGS THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOW OR NOT SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB
SITE CONDITIONS DURING THE COURSE OR CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY. THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMINIFY, AND HOLD THE OWNER
HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
WORK ON THIS PROJECT.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO
THE OWNER PRIOR TO THE COMMENCEMENT OR WORK.
�tOFES SIOp4 HUITFZOLLARS
SCE H. yG� Fyc
., Huitt-Zollars, Inc. Ontario
NO. 33366 m 3990 CONCOURS, X1330 • ONTARIO, CALIFORNIA 91761 • (909) 941-7799
IX01RATI011 a
6-30-2016
CME APPRovED BY MAURICE H. MURAD R.C.E. EXPIRES
OF CAE�F�
33366 6-30-16
CITY OF FONTANA, CALIFORNIA
BEMIn CEGB ONPROO MC Gid E 4 PLAMn S
DRAWN STAFF TITLE SHEET SCALE:
H -Z STAS SHOWN
DESIGNED BY: 15971 SANTA ANA AVENUE DATE:
DATE
M.H.M. 3-2016
CHECKED BY: APP `/ED DWG. NO.: 1
C�((P M.H.M. \ 5459
CITY EN INEER R.C.E. 51152 DATE: 3