HomeMy WebLinkAbout5407-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK, INSPECT70N COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OF GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS
THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO
AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL
UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXIS77NG SURVEY MONUMENTS MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED
LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED
DENSITY IS OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECT70N OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL
CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE,
SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE
VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE
ASTM DESIGNAT70N C700 FOR V.C.P.
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE
CITY ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO
ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY
ELEVATION AND LOCAT70N OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES
DOES NOT IMPLY CORRECTNESS OF ELEVAT70NS OR LOCATIONS SHOWN ON THE PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE
GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE
LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN 'S" IN THE FACE OF THE CURB AT THE LOCA77ON OF
THE SEWER LATERAL.
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
34. ALL UNDERGROUND U77LI77ES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
37. UPON COMPLET70N OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
RLT
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE I W_i 1-800-227-2600
A PUBLIC SERVICE BY
UNDERGROUND SERVICE ALERT
BASIS OF BEARINGS
THE BEARING OF NORTH 00'08'00" EAST
ALONG THE CENTERLINE OF REDWOOD
AVENUE AS SHOWN ON PARCEL MAP NO.
17634, WAS TAKEN AS THE BASIS OF
BEARINGS SHOWN UPON THIS SURVEY.
LEGEND
- -
EXISTING R/W
- -
PROPOSED R/W
----
LOT LINE
-
CENTER LINE
J�
FIRE HYDRANT
.........
PROPERTY LINE
R/W ..........
RIGHT OF WAY
T. .........
CENTERLINE
BOT. .......
BOTTOM
SD .......
STORM DRAIN
SMH .........
SEWER MANHOLE
STD .........
STANDARD
SEW .........
SEWER
TYP...........
TYPICAL
IMP...........
IMPROVEMENT
P.I.P..........
PROTECT IN PLACE
DWG .........
DRAWING
EXIST..........
EXISTING
RW ..........
RECYCLED WATER
INV .........
INVERT OF PIPE
UT .........
UTILITY
CVWD .........
CUCAMONGA VALLEY
O9
WATER DISTRICT
SPPWC.........
STANDARD PLANS FOR
5
PUBLIC WORKS CONSTRUCTION
-
PROPOSED STORM DRAIN
S
EXISTING SEWER
W
EXISTING WATER
EXISTING RECYCLED WATER
EXISTING STORM DRAIN
G
EXISTING GAS
T
EXISTING TELEPHONE
E
EXISTING ELECTRICAL
EASEMENT
NOTICE TO CONTRACTOR
�2 i WIVEDPRI 1plo mi0ji l*pmjjvslTffp'lvl0jEk4 mlValpffn
NOTE:
11IFFIFAIRN"M 'L "Nv.
CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
A. CONTRACTOR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
AFTER FINAL PAVING HAS BEEN INSTALLED.
CiINSTALL
SHT NO.
8"
(EXTRA STRENGTH) VCP SEWER LINE (BEDDING & BACKFILL PER
CITY OF FONTANA STD. 1008) ..........1189
LF
O2
INSTALL
SEWER CLEANOUT PER CITY OF FONTANA STD. 2006 & 2009.............................................................2
MALLORY DR
EA
O3
INSTALL
4'
SEWER MANHOLE PER CITY OF FONTANA STD. 2001.......................................................................5
EA
O
CONSTRUCT
MIN. 5.5" AC PAVEMENT OVER 12" OF 95% COMPACTED NATIVE
SUBGRADE PER CITY STD. 400....... 12,160
SF/418 TONS
50
ADJUST
RIM
TO GRADE AFTER FINAL PAVING IS INSTALLED............................................................................5
VALLEY
EA
s0INSTALL
ST
6"
VCP SEWER LATERAL PER CITY OF FONTANA STD. 2009...............................................................63
LF
70
GRIND 0.17'
MIN. OF EXIST. AC PAVEMENT AND OVERLAY 0.17' MIN. OF AC
PAVEMENT PER DETAIL A .................4850
SF
Os
REPLACE
EXISTING PAVEMENT STRIPING AND MARKINGS IN KIND...................................................................
1
LS
O9
TIE -OUT
&
RESET EXISTING SURVEY MONUMENT.......................................................................................
5
EA
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS
ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE THERE ARE NO
EXIS77NG UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUT70NARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOW OR NOT SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB
SITE CONDITIONS DURING THE COURSE OR CONSTRUCT70N OF THIS PROJECT, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY. THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMINIFY, AND HOLD THE OWNER
HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECT70N WITH THE PERFORMANCE OF
WORK ON THIS PROJECT.
CONTRACTOR SHALL VERIFY ALL CONDIT70NS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO
THE OWNER PRIOR TO THE COMMENCEMENT OR WORK.
SHEET INDEX
SHT NO.
DESCRIPTION
1
TITLE SHEET
2
SEWER IMPROVEMENT PLAN STA. 1+19.73 TO 8+00.00
3
SEWER IMPROVEMENT PLAN STA. 8+00.00 TO 13+27.16
BENCHMARK
CHISELED SQUARE AT THE EAST END OF THE
NORTHEAST CURB RETURN OF SAN BERNARDINO
AVENUE AND REDWOOD AVENUE. SAN BERNARDINO
COUNTY SURVEY BOOK 4015, PAGE 1843.
ELEVATION: 1085.081
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED. IN
PART, ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO THESE DOCUMENTS
AS A RESULT THEREOF.
I !I'EGORO 01FAWING5
NO. REVISION DESCRIPTION
'122114, M PA. 't • !'
DATE ENGR. I CITY DATE
SHEET-, 21
UTILITY CONTACTS
ELECTRI C1 TY
SOUTHERN CALIFORNIA EDISON CO.
300 N. PEPPER AVE.
RIALTO, CA. 92376
UNDERGROUND (909) 357-6233
TRANSMISSIONS: (909) 875-5100
PIPELINES: (213) 657-1233
DISTRIBUTION: (909) 357-6233
GAS
SOUTHERN CALIFORNIA EDISON CO.
1981 LUGONIA AVE
REDLANDS, CA. 92374
EMERGENCIES: (800) 427-2200
WA TER
FONTANA WATER CO.
15966 ARROW ROUTE
FONTANA, CALIFORNIA 92335
(909) 822-2201
CIVIL ENGINEER
HUI TT-ZOLLARS, INC
3990 CONCOURS, 11330
ONTARIO, CA. 91761
PHONE (909) 941-7799
FAX (909) 941-7789
CONTACT.• MAURICE MURAD
LEGEND
PROJECT.
LIMITS' {
VERIZON
4025 LA PALMA STREET
ANAHEIM, CA 92807
(714) 237-6146
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
P.O. BOX 518
FONTANA, CA 92335
(909) 350-6632
ATTN: CARLOS NAVARRO
TIME WARNER CABLE
1500 AUTO CENTER DR.
ONTARIO, CA 91761
(800) 892-2253
SOILS ENGINEER/GEOTECH
RANDALL AVE AkT
w 1�
>
a
0
3 >
o a
Ld
SAN BERNARDINO AVEuj
-
> EL MOLINO ST
a
I
a
MALLORY DR
O
aOf
w }
r-
ROSEMARY D
Z
J
a Of
IRIS DR
m
a
=
HUNTER ,
VALLEY
BLVD
ST
SOUTHERN CALIFORNIA GEOTECHNICAL, INC.
22885 SAW RANCH PARKWAY, SUITE E
YORBA LINDA, CA 92887
PHONE (714) 685-1115
FAX (714) 685-1118
CONTACT.• JOHN SEMINARA
'�I�Il�TII
SAN BERNARDINO FWY �
(INTERSTATE 10)
VICINITY MAP
2' TRENCH WIDTH 2'
MIN.) 10' MAX. (MIN.
O GRIND 0.17' MIN. O
EXIST. PAVEMENT AND
OVERLAY 0.17' MIN.
NOT TO SCALE
10
EXISTING PAVEMENT EXISTING PAVEMENT
NEW PAVEMENT O
PROPOSED SEWER
DETAIL A
NOT TO SCALE
SHEET 3
PROPOSED 8" SEWER
I
c'�✓ 12"wr is w' „- 12-W 1 12"r1�1 � 121W 12'W 1"gid=
G G G G \ G REDWOOR�_AVENUE
at
A
1.4
a
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
SHEET INDEX MAP
N. T. S.
C + _
A ,!
T�
� W
12
8`S -
G G
CITY OF FONTANA, CALIFORNIA
QROFESS/pNTr_ -ZOLLNPS
'l
H. yG� ul 3MVIER ORPROWIENIEH7 PLAHS
k s Huitt-Zollars, Inc. Ontario DRAWN BY: SCALE:
W N0. 33366 m 3990 CONCOURS, #330 * ONTARIO, CALIFORNIA 91761 * (909) 941-7799 H -Z STAFF 9 9 8 8 REDWOOD AVENUE AS SHOWN
EXPIRATION
* 6-30-2016 * DESIGNED BY: TITLE SHEET DATE:
Jl CIVIV NT
4-2016
'lF OF Cp��EAPPROVED BY MAURICE H. MURAD R.C.E. EXPIRES DATE M.H.M.
CHECKED BY: AP R ED Y: DWG. NO.
733366 6-30-16 �_ ICo M.H.M. 5407 : �/3