STOR.KA [DRAIN I-M--PROVEMENT PLAN
STORM DRAW IEMVEMBff GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'. ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL 110/CIT U S [DIST I UTION C N
BE.THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO
PRECEDENCE PROVISIONS IN THE "GREEN BOOK% THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER
FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION
PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE
START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF
CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT
ALL TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH
FROM ,THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE
GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF
CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT
PURPOSE
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE
PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT UMTTED TO, GAS, TELEPHONE,
ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD
CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15.ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK
TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION
CONTROL STAKING DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION
TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS,
SHALL BE DONE BY A REGISTERED CML ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A
RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE
MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20.THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE
PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
21.NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22.A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE
RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
23.CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF
THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
24.ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
25.NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
26.PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS.
CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE
PLANS.
27.IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE
ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28.NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
29.ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
30.APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31.ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR
UPON COMPLETION OF PAVING.
32.UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES AND OTHER TRAFFIC CONTROL
DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
33.AS-BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS
TO THE CITY ENGINEER.
STORM DRAIN CONSTRUCTION NOTES
O CONSRUCT TRANSITION STRUCTURE PER S.P.P.W.C. STD. PLAN NO. 340-2.
1
CONSTRUCT 24" R.C.P. BEDDING PER LAC.D.P.W. STD PLAN NO. 3080-2 CASE 3
223
SEE DETAIL ON SHEET 1, TRENCH REPAIR PER CITY OF FONTANA STD 1008.
3O CONSTRUCT 30" R.C.P. BEDDING PER LAC.D.P.W. STD PLAN NO. 3080-2 CASE 3
SEE DETAIL ON SHEET 1, TRENCH REPAIR PER CITY OF FONTANA STD 1008.
4O CONSTRUCT CONCRETE COLLAR PER S.P.P.W.C. STD. PLAN NO. 380-4.
5O CONSTRUCT CURB OPENING CATCH BASIN PER S.P.P.W.C. STD. PLAN
NO. 300-3, V AND "W" PER PLAN, WITH LOCAL DEPRESSION PER S.P.P.W.C.
STD. PLAN NO. 313-3 CASE or.
O CONSTRUCT MONOLITHIC CONNECTION PER S.P.P.W.C. STD. PLAN NO. 308-2.
O REMOVE EXISTING CMP RISER.
8O. BRICK AND MORTAR END OF PIPE
QUANTITIES
1 EA.
142 LF.
24 LF.
5 EA.
3 EA.
1 EA.
2 EA.
3 EA
PREPARED FOFO SOILS ENGWEER.
LIT INDUSTRIAL LIM/TED PARTNERSHIP NORCAL ENGINEERING
2201 E. CAMELBACK ROAD, SUITE 225B SOILS & GEOTECHNICAL CONSULTANTS
PHOENIX, AZ 85016 10641 HUMBOLT STREET
PHONE: (602) 337-8730 LOS ALAMITOS, CA 90720
FAX: (770) 373-4940 PHONE: (562) 799-9469
..r.+f. I
UNTANA, CA IFO NIA
UTLITY C WrACTS
SAN BERNARDINO COUNTY FLOOD CONTRnl
825 E. THIRD STREET, ROOM 140
SAN BERNARDINO, CA 92415-0835
PHONE: (909) 387-8256
ATTN: TOM WILLIAMS
FONTANA WATER COMP,
15966 ARROW ROUTE
FONTANA, CA 92355
PHONE: (909) 822-2201
ATTN: BRENDA FOWLER
1981 W. LUGONIA AVE.
REDLANDS, CA
PHONE: (909) 335-7965
ATTN: ED SANTILLAN
AT&T
1265 VAN BUREN ST. #180
ANAHEIM, CA 92807
PHONE: (714) 666-5614
ATTN: LEE QUEST
SOUTHERN CALIFORNIA EDISON
7951 REDWOOD AVENUE
FONTANA, CA 92336
PHONE: (909) 549-5345
ATTN: JEFF HUDSON
TIME WARNER
17777 CENTER COURT DR. 8TH FLOOR
CERRITOS, CA 90703
PHONE: (562) 677-0263
ATTN: JOHN CHRISTIANSEN
FONTANA UNITED SCHOOL DISTRICT
9680 CITRUS AVENUE
FONTANA, CA 92335
PHONE: (909) 357-5000 X 29455
ATTN: SHERRI WHITTEN
INLAND EMPIRE UTILITY AGENCY
(FOR SEWER)
6075 KIMBALL AVENUE
CHINO, CA 91708
PHONE: (909) 993-1696
ATTN: LIZA MUNOZ
TOLL FREE -qftwm"'- 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT �V
A.B.
-AGGREGATE BASE
M.H.
A.C.
-ASPHALT CONCRETE
N.G.
B.C.R.
-BEGINNING OF CURVE
Ik
BLDG
-BUILDING
PB
B.O.W.
-BOTTOM OF WALL
P.P.
B.W.
-BACK OF WALK
R/W
C.L.F.
-CHAIN LINK FENCE
R.D.
CONC.
-CONCRETE TRANS PAD
C.F.
-CURB FACE
T.B.
C.B.
-CATCH BASIN
S =
q
-CENTERLINE
S.D.
E.C.R.
-END OF CURVE
S.L
EXIST.
-EXISTING
ST.LT.
E.P.
-EDGE OF PAVEMENT
T.G.
F.G.
-FINISH GRADE
T.C.
F.F.
-FINISH FLOOR
TOP
F.L
-FLOW UNE
TOE
F.S.
-FINISH SURFACE
WM
F.H.
-FIRE HYDRANT
WV
G.B.
-GRADE BREAK
H.C.
-HANDICAP
H.P.
-HIGH POINT
INV.
-INVERT
-MANHOLE
-NATURAL GRADE
-PROPERTY LINE
-PULL BOX
-POWER POLE
-RIGHT OF WAY
-ROOF DRAIN
-TRANSFORMER PAD
-TOP OF BERM
-SLOPE
-STORM DRAIN
-SIGHT LINE
-STREET LIGHT
-TOP OF GRATE
-TOP OF CURB
-TOP OF SLOPE
-TOE OF SLOPE
-WATER METER
-WATER VALVE
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTIUTY PIPES, CONDUITS,
OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED
TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTIUTIES SHOWN ON
THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND
RESPONSIBIUTY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN ON
THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBIUTY
FOR JOB SITE CONDITIONS DURING COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT
THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE COUNTY OF SAN
BERNARDINO, THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGUGENCE OF THE OWNER OR THE
ENGINEER.
i�
INDEX MAP
SCALE: 1 " - 100'
TOP OF BEDDING 8 UNLESS
OTHERWISE NOTED IN THE
SPECIFICATIONS
BEDDING 13
BEDDING MATERIAL BELOW BOTTOM
OF RCP SHALL 8E .0830' FOR PIPES
97$mm 4391 AND LARGER 114 01AMETER.
AND 100mm 440) RCP LESS THAN 975mm
(39') IN DIAMETER. IN NO CASE SHALL
IT 13E LESS THAN 30mm (11) BELOW ANY
BELL. OR COt.LM
t
SAN BERNARDINO FRWY
W
15-08
I
TITLE SHEET - CONSTRUCTION NOTES
& QUANTITY ESTIMATES
2
PROPOSED PUBLIC STORM DRAIN AND
CATCH BASIN
CITY OF FONTANA, CALIFORNIA
STORM DRAIN IMPROVEMENT PLAN
SO
A ANA
AVENUE
m'""
HF.
SEEFRIED FONTANA P.M.19659s�OwN
AS
JURUPA
CITRUS AVENUE & CATAWBA AVENUE
cr
� k•
AVENUE
OF
Alm.
VICINITY MAP
N.T.S.
BACKFILL AS SPECIFIED
EXCAVATED BANK OR SHEETING
BEDDING A
mm EXCAYATION TO THIS
100
loo m h. LINE PERMITTED
CASE 3
REINFORCED CONCRETE PIPE
NOTES.
CASE 3 BEDDING 8 BACKFILL AROUND RCP tLOA0 FACTOR 1.13)
Tal W AT SPRING LINE SHALL /� NOT BE .ESS THAN THE FOLLOWING- 150mm
(6'1 FOR RCP 1500mm (60') OR LESS IN DIAI`IETER, 250mm 110') FOR RCP
1575mm (639) TO 2700mm (108.) INCLUSIVE IN DIAMETER, AND 300mm (12.1
FOR PIPE LARGER THAN 2700mm Q08') IN DIAMETER. THESE DIMENSIONS
MAY INCL -UDE THE THICKNESS OF ANY SHEETING.
(b] WHERE COVER IS 3M 410'-0'l OR LESS, W MEASURED AT THE TOP OF THE
RCP MAY BE ANY DIMENSION GREATER THAN THE ABOVE SPECIFIED MINIMUM
UNLESS OTHERWISE SPECIFIED ON THE PROJECT DRAWINGS.
Cc) WHERE COVER 18 GREATER THAN 3m (10'-00). W MEASURED AT TOP OF PIPE
SHALL NOT BE GREATER THAN 250mm (1041 FOR RCP 2700mm (logo) IN DIAMETER
OR LESS. OR 300man 1112.1 FOR RCP OVER 2700mm (106.) IN DIAMETER UNLESS
THE CONTRACTOR AT HIS OWN EXP HSE PROVIDES CAS I BEDDING OR STRONGER
RCP. THESE 01MCNSIONS INCLUDE HE THICKNESS 4F NY SHEETING.
(d) SCREED BEDDING A TO FIT CURVATURE AND GRADE OF RCP. TYPE OF SCREE()
AND THE METHOD OF USE T4 BE APPROVED BY THE ENGINEER.
SAC FILL AS
SPECIFIED
C
s
EXCAVATED "
BANK OR 1141
SHEETING "
ROUGHEN a
SURFACE-----�
SACKFILL AS
SPECIFIED
43' ANCE
M a
s 200 -C -I5 EXCAVATED 6ANK
(420-C-2000) OR SHEETING
CONCRETE
EXCAVATION
.3750' TO THIS LINE
JOINT PERMITTED---
:.,_._ �., � ...., ...,... 1
GRADE ADJUSTMENTCONO
PIPE
RETE IS AIO.AIMLBE AND K NOURS L
D ISEFORE
SHALL BE SPECIFIED ON
THE PROJECT DRAWINGS OR 8Y THE ENGINEER
CASE 4.
NOTlrs
CASE 4 SEDOING 4LOAD FACTOR 3.01
WHERE REQUIRED BY THE E14GINEER AS
AN ALTERNATIVE TO CASE I OR CASE 3
TO MEET CONDITIONS ARISING DURING
CONSTRUCTION.
200-C-13
(420-C-2000)
CONCRETE
i
E
In oa
CASE 5
IVO TEt
CASE 3 BEDDING (LOAD FACTOR 2.7)
SHALL BE USED WHERE SPECIFIED ON
THE PROJECT DRAWINGS. CASE 4
BEDDING SHALL BE USED INSTEAD OF
CASE 5 AGAIKST SHEETING OR UNSTABLE
TRENCH WALLS IF SO REQUIRED BY THE
ENGINEER.
LOS ANGELES COUNTY DEPARTMENT -OF PUBLIC WORKS
STANDARO PLAN
PIPE BEDDING IN TRENCHESMETRIr,
3080--2
SHEET 2 OF 3
i
BAW OF BEAF04M
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA STATE PLANE
COORDINATE SYSTEM (CCS83), ZONE 5, NORTH AMERICAN DATUM 1983 (NAD83)
BASED LOCALLY ON CONTINUOUSLY OPERATING REFERENCE STATIONS (CORS)
"LORS" AND "EWPP" AS SHOWN HEREON (BASIS OF BEARINGS: S 81'29'26" E).
ALL BEARINGS SHOWN HEREON ARE GRID BEARINGS.
BENO-I MARK:
CITY OF FONTANA 8ENCHMARK NO. '289"
FOUND RAILROAD SPIKE IN THE NORTHWEST SIDE OF POWERPOLE NUMBER 61319 AT THE
NORTHEAST CORNER OF THE INTERSECTION OF SANTA ANA AVENUE AND CATAWBA AVENUE
E &A77ON = 1032.22'
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
REn0N DESCRIPTION DAZE ENM CITY DATE STANDARDS IN EFFECT.
�tOFESS/0�, l
* R.C.E. NO. 56155' *
12-31-16
9�F CIV 1\- o��
0F C A��F
Prepared Under The Supervision Of
Thienes Engineering, Inc.
CML ENGINEER/NG • LAND SURVEYING
14.349 f7RESTONE BOULEVARD
LA M/IR4LL(, CALIMRN14 906.38
PN.(714)521-4811 FA.V144V-417.1
SHEE7 NM
15-08
I
TITLE SHEET - CONSTRUCTION NOTES
& QUANTITY ESTIMATES
2
PROPOSED PUBLIC STORM DRAIN AND
CATCH BASIN
CITY OF FONTANA, CALIFORNIA
STORM DRAIN IMPROVEMENT PLAN
AVENUE
m'""
HF.
SEEFRIED FONTANA P.M.19659s�OwN
� k•
AVENUE
OF
Alm.
VICINITY MAP
N.T.S.
BACKFILL AS SPECIFIED
EXCAVATED BANK OR SHEETING
BEDDING A
mm EXCAYATION TO THIS
100
loo m h. LINE PERMITTED
CASE 3
REINFORCED CONCRETE PIPE
NOTES.
CASE 3 BEDDING 8 BACKFILL AROUND RCP tLOA0 FACTOR 1.13)
Tal W AT SPRING LINE SHALL /� NOT BE .ESS THAN THE FOLLOWING- 150mm
(6'1 FOR RCP 1500mm (60') OR LESS IN DIAI`IETER, 250mm 110') FOR RCP
1575mm (639) TO 2700mm (108.) INCLUSIVE IN DIAMETER, AND 300mm (12.1
FOR PIPE LARGER THAN 2700mm Q08') IN DIAMETER. THESE DIMENSIONS
MAY INCL -UDE THE THICKNESS OF ANY SHEETING.
(b] WHERE COVER IS 3M 410'-0'l OR LESS, W MEASURED AT THE TOP OF THE
RCP MAY BE ANY DIMENSION GREATER THAN THE ABOVE SPECIFIED MINIMUM
UNLESS OTHERWISE SPECIFIED ON THE PROJECT DRAWINGS.
Cc) WHERE COVER 18 GREATER THAN 3m (10'-00). W MEASURED AT TOP OF PIPE
SHALL NOT BE GREATER THAN 250mm (1041 FOR RCP 2700mm (logo) IN DIAMETER
OR LESS. OR 300man 1112.1 FOR RCP OVER 2700mm (106.) IN DIAMETER UNLESS
THE CONTRACTOR AT HIS OWN EXP HSE PROVIDES CAS I BEDDING OR STRONGER
RCP. THESE 01MCNSIONS INCLUDE HE THICKNESS 4F NY SHEETING.
(d) SCREED BEDDING A TO FIT CURVATURE AND GRADE OF RCP. TYPE OF SCREE()
AND THE METHOD OF USE T4 BE APPROVED BY THE ENGINEER.
SAC FILL AS
SPECIFIED
C
s
EXCAVATED "
BANK OR 1141
SHEETING "
ROUGHEN a
SURFACE-----�
SACKFILL AS
SPECIFIED
43' ANCE
M a
s 200 -C -I5 EXCAVATED 6ANK
(420-C-2000) OR SHEETING
CONCRETE
EXCAVATION
.3750' TO THIS LINE
JOINT PERMITTED---
:.,_._ �., � ...., ...,... 1
GRADE ADJUSTMENTCONO
PIPE
RETE IS AIO.AIMLBE AND K NOURS L
D ISEFORE
SHALL BE SPECIFIED ON
THE PROJECT DRAWINGS OR 8Y THE ENGINEER
CASE 4.
NOTlrs
CASE 4 SEDOING 4LOAD FACTOR 3.01
WHERE REQUIRED BY THE E14GINEER AS
AN ALTERNATIVE TO CASE I OR CASE 3
TO MEET CONDITIONS ARISING DURING
CONSTRUCTION.
200-C-13
(420-C-2000)
CONCRETE
i
E
In oa
CASE 5
IVO TEt
CASE 3 BEDDING (LOAD FACTOR 2.7)
SHALL BE USED WHERE SPECIFIED ON
THE PROJECT DRAWINGS. CASE 4
BEDDING SHALL BE USED INSTEAD OF
CASE 5 AGAIKST SHEETING OR UNSTABLE
TRENCH WALLS IF SO REQUIRED BY THE
ENGINEER.
LOS ANGELES COUNTY DEPARTMENT -OF PUBLIC WORKS
STANDARO PLAN
PIPE BEDDING IN TRENCHESMETRIr,
3080--2
SHEET 2 OF 3
i
BAW OF BEAF04M
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA STATE PLANE
COORDINATE SYSTEM (CCS83), ZONE 5, NORTH AMERICAN DATUM 1983 (NAD83)
BASED LOCALLY ON CONTINUOUSLY OPERATING REFERENCE STATIONS (CORS)
"LORS" AND "EWPP" AS SHOWN HEREON (BASIS OF BEARINGS: S 81'29'26" E).
ALL BEARINGS SHOWN HEREON ARE GRID BEARINGS.
BENO-I MARK:
CITY OF FONTANA 8ENCHMARK NO. '289"
FOUND RAILROAD SPIKE IN THE NORTHWEST SIDE OF POWERPOLE NUMBER 61319 AT THE
NORTHEAST CORNER OF THE INTERSECTION OF SANTA ANA AVENUE AND CATAWBA AVENUE
E &A77ON = 1032.22'
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
REn0N DESCRIPTION DAZE ENM CITY DATE STANDARDS IN EFFECT.
�tOFESS/0�, l
* R.C.E. NO. 56155' *
12-31-16
9�F CIV 1\- o��
0F C A��F
Prepared Under The Supervision Of
Thienes Engineering, Inc.
CML ENGINEER/NG • LAND SURVEYING
14.349 f7RESTONE BOULEVARD
LA M/IR4LL(, CALIMRN14 906.38
PN.(714)521-4811 FA.V144V-417.1
SHEE7 NM
15-08
I
TITLE SHEET - CONSTRUCTION NOTES
& QUANTITY ESTIMATES
2
PROPOSED PUBLIC STORM DRAIN AND
CATCH BASIN
�u ate • 3 (O I IO
EINHARD STENZ L RCE NO. 56155
WDEV 8-436C375148 OR
15-08
CITY OF FONTANA, CALIFORNIA
STORM DRAIN IMPROVEMENT PLAN
m'""
HF.
SEEFRIED FONTANA P.M.19659s�OwN
AS
CITRUS AVENUE & CATAWBA AVENUE
DESIGN
T SHEET
DATE.
RH
---aNSTRUCTION NOTM& QUANTITY ESTIMATES
10-26-2015
CHECKED Ery.
AP VED //
3
DRAWING NO.:
MR
�P
54 5 3OZ
IA2
'CITY ENGINEER DATE: