HomeMy WebLinkAbout5013-32+24VDC PUMP 1 1-10A PUMP 2 I -40A PUMP 3 I -40A PRIMARY START SEQUENCE 1-11G1-4 WATER START SEQUENCE — 24VDC PI RESET A I -IAN D AUTO CR7— I CR10-1 CR1-1 P1 START PI P2 RESET RESET A HAND CR14 P2 — START CRI4-3 RS2 I A P3 RESET CRI3 —2 RS SCADA SIGNAL "PUMP PI FA I LIJRE" 1 RESET CRI4 2 RS2-1 CR15-2 AND AUTO CRq I CR12-1 CR15-1 P3 START P3 CR28 LEAD PUMP WATER LEVEL. LAG PUMP WATER L_VEL ALTERNATOR CR4-2 I -I I GH WATER SCADA SIGNAL "I -41G1-1 WATER" CR5-2 CR5 SCALA SIGNAL "LOIA1 WATER" L LOW WATER CR5 1-4IGH WATER TIME DELAY RELAY HOLDING RELAY HIGH WATER TIME DELAY START Trii -1 SCADA SIGNAL "PUMP P2 FAILURE" SCADA SIGNAL "PUMP P3 FA I LURE" P3 RESET CRI6 —I CR2I —2 EMERGENCY STOP CRI7 —1 CRI8— I CRICt— 11, SCADA SIGNAL "LOSS OF CONTROL POWER" SCADA SIGNAL "ATS TRANSFER TO EMERGENCY POWER" SCADA SIGNAL "BU I LDI NG DOOR ENTRY ALARM SIGNAL SCAIDA SIGNAL "GENERATOR FAIL ALARM" CR20— I P2 EMERGENCY STOP CR2I LR I — I LR I —3 SCADA SIGNAL "AIR FLOW. ITCI-1 FAILURE ALARM" (EF1) SCADA SIGNAL "AIR FLOW SNITC FAILURE ALARM" (EF2) VENTILATION ALARM STATUS LIGI-IT RED EXTERIOR CR22— 1 R12 EMERGENCY STOP VENTILATION ALARM STATUS LIGHT GREEN EXTERIOR ,42gmeav=====oftw=emomommem SCADA SIGNAL "PRIMARY POWER LOSS" DPIAIL• ES: . PRIMARY SCI-1EMATIC IS DIAGRAMMATIC AND REPRESENTATIVE OF REQUIRED LOGIC; TI -4E LOGIC S1401AIN MAY BE IMPLEMENTED USING DISCRETE PARTS OR TI -ROUGH TI -IE USE OF PLC LOGIC; CONTRACTOR SHALL SUBMIT COMPLETE CONTROL WIRING DIAGRAM. 2. STARTER FAIL RELAY FROM RVSS UNIT; PUMP AS NOTED. 3. HAND MODE RELAY FROM I -40A SIAI I TCI -1 TO SIGNAL BYPASS LOW LEVEL SI-IUTDOkIN CIRCUIT; PROVIDE HAND MODE BYPASS FROM EACH STARTER; CONNECT EACH DEVICE IN PARALLEL. 4. N .0. CONTACT FROM PLC CONTROLLED BY PRESSUER TRANSDUCER; CLOSE UPON WATER REACHING DESIGNATED LEVEL; DESIGNATED LEVELS SET PER CIVIL ENGINEERS PLAN; ELECTRICAL CONTRACTOR SI-IALL ADJUST LEVEL SETTINGS PER CIVIL PLANS. 5. UPON 1-4IG4 WATER ALARM; ALL PUMPING IS CALLED AND SCADA SIGNAL SENT. 6. ALERNATOR; CALLS LEAD PUMPS, THEN CALLS LAG PUMP; AUTOMATICALLY ROTATES START SEQUENCE (PI —P2, P2 — P3, P3 — PI ); WI-IEN CALLED TO STOP PUMPING LEAD PUMP IS SI-IUT DOWN FIRST; LAG PUMP IS SHUTDOWN SECOND. 7. TIME DELAY ADJUSTABLE FROM 0-150 SECONDS SET AT 0 SECONDS 5. TIME DELAY ADJUSTABLE FROM 0-150 SECONDS SET AT 60 SECONDS. G1TIME DELAY ADJUSTABLE FROM 0-150 SECONDS SET AT 120 SECONDS. 0. AT LOIAI 1AIATER LEVEL, PUMP CONTROLS ARE ACTIVATED AND REMAIN ACTIVATED UNTIL LOW WATER RELAY OPENS. 1 1 . SEE VE2.2 FOR ALARM LOCATIONS. 12. N.0. CONTACT FROM AIR FLOIAI SWITCH; CLOSES UPON LOSS OF AIR FLOW; SEE CIVIL PLANS. 3. N.0. CONTACTS FROM DRY IAIELL FLOAT SIAI I TCH 4. N O. CONTACTS FROM INTRUSION ALARMS AT BUILDING DOOR; NUMBER OF DEV ICES PER PLANS; CONNECT EACI4 DEVICE IN PARALLEL; ALARM IS SENT UPON ANY DOOR OPENING; PROV I DE TERMINAL BLOCKS TO CONNECT UP TO 10 PARALLEL DEVICES. 15. EMERGENCY OFF PUSH BUTTON MOUNTED ADJACENT TO PUMP MOTOR. 1. SEE DETAIL 3/E2.3. 7. N.0. CONTACT FROM GENERATOR; CLOSES UPON GENERATOR FAILURE; SEE ELECTRICAL SPECIFICATION. 15. N.0. CONTACT FROM AUTOMATIC TRANSFER SIAI I TCI -1 CLOSES UPON LOSS OF POWER FROM UT L I TY POWER. (NORMAL POWER). l. N.0. CONTACT FROM MINI CAS UNIT; CLOSES UPON PUMP FAILURE; PUMP AS NOTED. 20. N .0. CONTACT FROM ATS CLOSES UPON TRANSFER TO EMERGENCY POWER SOURCE. 21. LIGHTING CONTACTOR TO CONTROL LOCAL VENTILATION AUDIBLE/VISUAL ALARMS; CONTACTOR RATING PER LOAD CONTROLLED; ASCO 'q181 SERI ES IAI I TI -1 TWO — IAI I RE CONTROL AND COMB I NAT ION NO/NC OR EQUAL. SCADA SIGNAL "DRY WELL FLOOD" LRI —2 VENTILATION ALARM/STROBE INTERIOR Prepared Under The Supervision Of S (JULE) CONSTRUCT (T\ OF THE REQU RED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF T E DATE OF APPROVAL SHOWN HEREON AND CARR ED FOPT- IN A DIL CENT MA \NEP, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE LANS TO BR NO THEM INTO CONFORMANCE WITH STANDARDS N EFECT. EFORE TWO WORK I NG DAYS BEFORE YOU DIG YOU DIG TOLL FR 00-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. heeler CONSULTING CIVIL ENGINEERS 870 M A • T STREET, SUITE 1278 SAN FRANCISCO, CA 94102 (415) 433-4848 No. 014906 SI EXP. 30 JUNE 13 TR\ REVISION DESCRIPTION DATE ENCR. CITY DATE CF FEHR ENGINEERING COMPAN, INC. 62—A HANGAR WAY wAisowiLLE, CAUFORNIA, 95076 PHONE: (831) 786-0373 FAX (831) 786-8523 Inc EMAIL: FEC,eFEHRINC.COM CONSULTING ELECTRICAL ENGINEERS FE JOB No. 11081.00 OF ONTANA, CALIFORNIA SANITARY SEWER PUMP STATION REPAIRS DRAWN BY: CL. DESIGNED BY: T.P. CONTROL DIAGRAM OUTHRIDGc„, PUMP STATION CHECKED BY: T.P. APPROV' " ENGINEER RC DATE: .E. 51152 if CALE: AS SHOWN DATE: 4/1/13 DP \51 NO.: 0 I 32 3