Loading...
HomeMy WebLinkAbout5013-28FEHR ENGINEERING COMPANY, INC. 62—A HANGAR WAY WATSONVILLE, CALIFORNIA, 95076 PHONE: (831) 786-0373 FAX: (831) 786-8523 EMAIL: FEC FEHRINC.COM CONSULTING ELECTRICAL ENGINEERS FE JOB No. 11081 00 cT OF FONTANA, CALIFORNIA SCALE: AS SHOWN A. ALL ELECTRICAL SHONN 13 NEN, U .0.N . ft ALL CIRCUIT BREAKERS ARE 3 -POLE, U.O.N. C. VOLTAGE DESIGNATIONS: (U.O.N.) 240 - 1 = 240/120V - 1 PH -31^1 I RE 450-1 = 450V - I PH -2IN I RE 205Y = 205/120V -3PI4 -4 1A1 I RE 450Y = 450/277V - 3 PH - I RE 480 A = 450V - 3 PH -3 N I RE D. "KA" AT CIRCUIT BREAKERS DENOTES MINIMUM REQUIRED CAPACITY IN AMPS (x 1000). E. SPO AT BREAKER DENOTES: PROVIDE MOUNTING SPACE * FOR FUTURE 3 -POLE BREAKER OF RATINGS INDICATED, INTERRUPTING I-IARDINARE FR No. BFO I 13F02 B F03 CONDUIT AND C NDUCTCRS %'c., 34110, 1#10 GN 2#14 VC., 34410, 11110 GN 2#14 3zt10, Iwo GN 2#14 REMARK PUMP BP -2 B502 (E) UTILITY TRANSFORMER /2 AIN ARBEE PEDESTAL BPI; 30A 240-1 PUMP BP -1 240V, 30, 2.7 HP (7.5 FLA) PUMP BP -2 240V, 30, 2.7 HP (7,5 FLA) CONTROLS SECTION BPI TYPE NEMA 3R 30A, 0, 3N LT240-1 MOUNT PEDESTAL MA NS 0/2 C.13. CONNECTED LOAD A I C 10, 000 FEED BOTTOM KVA 7.0 A ® USE VOLT -AMPS A B TRIP P-1 VF: 560 25 560 2 BP -2 VFD 1 SPACE ONLY 560 25 AillE1 3120 1560 2 7 IPSP I I 3120 * TANDEM CI RCU IT BREAKER 2@20/1 3 5 TRIP VOLT -AMPS A B USE 20/1 550 PEDESTAL LTS I-ITRS 4 200 CONTROLS SPARE 10 12 14 16 TED LO 550 200 LT. SW. L L LJ r UTIUTY M R PUMP STARTERS MAINTENANCE 4 - FLEX RECEPTACLE. TYPICAL CIRCUIT BREAKERS CONDUITS TO LOADS; SEE SITE PLAN I/64.1 FOR EXACT NUMBER REQUIRED. 1,11,111., 1 . (E) SECONDARY SERVICE; CCX)RDI NATE IN I TH UTILITY TO RECONNECT (N) PUMP PEDESTAL INIT1.4 (E) UTILITY SERVICE. 2. INTRUSION ALARM DEVICE AT EAG4 PEDESTAL DOOR; CLEARWATER TECI-I 2500 SERI ES MAGNETIC POSITION SENSOR OR APPROVED EQUAL; PROVIDE APPROPRIATE MOUNT I NG HARDWARE FOR EACH DOOR TYPE; SEE CONTROL DIAGRAM AND MAKE APPROPRIATE CONNECT ION VIA 21:t14. 3. SEE PANELBOARD SCHEDULE FOR ALL PEDESTAL LOADS. 4. SECTION HEATER; 250N MINIMUM 120V; PROVIDE SINGLE THERMOSTAT CONTROL CENTRALLY LOCATED IN PEDESTAL. 5. GENERATOR PLUG MOUNTED ON EXTERIOR OF PEDESTAL; PROVIDE IA I TH ANGLE ADAPTER; 240V, 30A, 10; RUSSELLSTOLL "MAXGARII OR EQUAL; CONFIRM COMPLIANCE WITH CITY'S GENERATOR AND PROVIDE EQUIPMENT SUBMITTAL PRIOR TO PURCHASE. . CONTROL PLC; SEE DETAILS 1/E60 21E6.0. 7. CONCRETE EQUIPMENT PAD PROVIDED * INSTALLED BY CONTRACTOR, SEE CIVIL PLANS; COORDINATE EXACT REQUIREMENTS FOR ELECTRICAL EQUIPMENT BEING INSTALLED. 5. TOTAL CONNECTED LOAD IS 7.0kVA OR 29 AMPS AT 240V, 10; DEMAND IS 5% OR 1.6 AMPS AT 240V, 10. . ONLY BP -1 OR BP -2 RUNS SIMULTANEOUSLY. 10. BACKUP CELLULAR AUTQDIALER; SEE ELECTRICAL SPECI FICAT ION . 1 I . CONDUIT FOR FLOAT SN ITCH CABLES; CONTRACTOR SHALL.. DETERMINE FLOAT SW ITCH CABLE LENGTH AS REQUIRED BY F I ELD CONDITIONS. 2. FLOAT SN ITCH INTRINSICALLY SAFE CONTROLS; ONE FOR EACH FLOAT Ski I TCH; WARRICK SERI ES 27 BY GEMS SENSORS. 13. INTERLOCKED CIRCUIT BREAKERS MANUAL LOAD TRANSFER; CIRCUIT BREAKERS SHALL BE PERMANENTLY INTERLOCKED SO T1 -IAT ONLY ONE CIRCUIT BREAKER MAY BE CLOSED SIMULTANEOUSLY. 14. AUTODIALER; SEE ELECTRICAL SPECIFICATION. 15. VFD INPUT 240V, 10 TO DRIVE 240V, 30 MOTOR; 3I -4P RATED VFD; DISABLE PHASE LOSS PARAMETER. CONDUIT FOR PRESSURE TRANSDUCER CABLE; SEE DETAIL 2/E6.0. 17. SERVICE GROUND ROD WITHIN PEDESTAL ENCLOSURE; SEE DETAIL 41E5.0 SIMILAR. 15. CABLE SPLICE; SEE 2/E4.l. 19. PUMP CABLE SUPPLIED IN ITI-4 PUMP. 20. MINI CAS UN ITS PROVIDED NITH PUMPS. SHOULD CONSTRUCT 00 OF THE REQUIRED IMPROVEMENTS , NOT COMMENCE WITH 0 TWO YEARS OF THE DATE 0- ,APPROVAL SHOWN ERRON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENCIHNEEP, MAO REQUIRE REV S0HS TO THE IDLAhlS TO BR q.\.] G THEM I \ITO CON FOR v A 1 CE 11/ STANDARDS IJ EFFECT. DIAL BEFO YOU DIG TWO WORKING YS BEFORE YOU DIG TOLL FREE 180O2272600 A PUBLIC SERVICE BY UNBERGRI. 0 SERVICE ALERT M111111111111•11111111 11111M IN =•111 1111111111111111111 REVISION DESCRIPTION DATE ENGR. CITY DATE S h a heeler CONSULTING CIVIL ENGINEERS 870 A T STREET, SUITE 1278 SAN FRANCISCO, CA 94102 (415) 433-4848 Prepared Under The Supervision Of Dote', THOMAS PINKERTON SANITARY SE ER PUMP STATION REPAIRS DRAWN BY: C.L. DESIGNED BY: T.P. CHECKED BY: T.P. BARBEE IMPROVEMENT DATE: 4/1 /1 3 DRNMNG NO: