Loading...
HomeMy WebLinkAbout5434-1U V) w F- I N Z N La Z Q � w I N \ w U w N � \ I o X w I 8d Of U Iw Iw VALLEY 16' 12' I 17' EX. R/W EX. C&G I I 7=7 ---------------- -- o i F IMPROVEMENTS � /'S 0 I I � OF RECORD �I N (' II 11 � EX. R/W EX. 2-1/2"C.-12 PR #22 S.I.C. TO VALLEY/INLAND CENTER X' W L 16' 12' I 12' 1I' 1 10 1 110' Ill' I 12' I 13' 75' 7' TRAFFIC SIGNAL INTERCONNECT/COMMUNICATION GENERAL NOTES U 1. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL 7. w CONFORM TO THESE PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND CITY'S SPECIAL PROVISIONS, SECTION E, THE STANDARD PLANS AND SPECIFICATIONS 0 OF THE STATE OF CALIFORNIA, DATED 2010, AND THE CALIFORNIA MANUAL OF 10 FURNISH AND INSTALL P48 PULLBOX AND SPLICE CANISTER. TRAFFIC CONTROL DEVICES, DATED 2014. 8. N L� U \ U� 2. U � 20 U FONTANA ENGINEERING DIVISION PRIOR TO COMMENCENT OF WORK. 9. WHEN PULLBOXES AND SPLICE VAULTS ARE INSTALLED WITHIN SIDEWALK, THE W DEPTH SHALL BE ADJUSTED SO THAT THE TOP IS FLUSH WITH THE TOP OF THE 3. a a: SIDEWALK. WHEN INSTALLED IN UNIMPROVED AREAS, THE DEPTH SHALL BE w � cx I w CITY FURNISHED OR PROVIDED AS NOTED IN SECTION E. W CL o_ co 4. LOCATION OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE. CONTRACTOR SEALING COMPOUND. ALL GROUND CONNECTIONS SHALL BE COATED WITH PULL EXISTING 96 STRAND SMFO CABLES TO NEW P48 PULLBOX SHALL BE RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING 9Li I FACILITIES WITHIN THE AREA OF CONSTRUCTION. THE CITY ENGINEER SHALL BE SEALED AFTER ALL CONDUIT ENTRANCES HAVE BEEN MADE. 17' EX. R/W EX. C&G I I 7=7 ---------------- -- o i F IMPROVEMENTS � /'S 0 I I � OF RECORD �I N (' II 11 � EX. R/W EX. 2-1/2"C.-12 PR #22 S.I.C. TO VALLEY/INLAND CENTER X' W L 16' 12' I 12' 1I' 1 10 1 110' Ill' I 12' I 13' 75' 7' PROP. R/W PROP. C&G EX. R/W EX. C&G wN O - i �r- wro ( \ `- o N 4 EX. C&G EX. R/W BOULEVARD EX.2-1 /2"C.-12 PR #22 S.I.C. Tr P, / — — — O VALLEY/VINEYARD VALLEY TRAFFIC SIGNAL INTERCONNECT/COMMUNICATION GENERAL NOTES 1. ALL WORK, MATERIALS, EQUIPMENT AND TEMPORARY TRAFFIC CONTROL SHALL 7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY ENGINEER FOR EXACT CONFORM TO THESE PLANS, THE CITY OF FONTANA STANDARD SPECIFICATIONS, THE EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET AND CITY'S SPECIAL PROVISIONS, SECTION E, THE STANDARD PLANS AND SPECIFICATIONS SECTION E. OF THE STATE OF CALIFORNIA, DATED 2010, AND THE CALIFORNIA MANUAL OF 10 FURNISH AND INSTALL P48 PULLBOX AND SPLICE CANISTER. TRAFFIC CONTROL DEVICES, DATED 2014. 8. PULLBOXES AND SPLICE VAULTS SHALL NOT BE INSTALLED WITHIN THE BOUNDARIES L� OF NEW OR EXISTING WHEEL CHAIR RAMPS. 2. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF 20 CUT/DISCONNECT THE 96 STRAND SMFO AND 12 STRAND SMFO CABLE FROM SPLICE CANISTER. REMOVE P48 PULLBOX COMPLETE. FONTANA ENGINEERING DIVISION PRIOR TO COMMENCENT OF WORK. 9. WHEN PULLBOXES AND SPLICE VAULTS ARE INSTALLED WITHIN SIDEWALK, THE W DEPTH SHALL BE ADJUSTED SO THAT THE TOP IS FLUSH WITH THE TOP OF THE 3. CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO SIDEWALK. WHEN INSTALLED IN UNIMPROVED AREAS, THE DEPTH SHALL BE CONSTRUCT THE INTERCONNECT CIRCUIT AS SHOWN ON THE PLANS, EXCEPT ANY ADJUSTED SO THAT THE TOP IS 1" ABOVE GRADE. EXTEND ALL OF THE CONDUITS TO THE NEW P48 PULLBOX. NOTE THAT CONDUITS MAY NEED TO BE LOWERED. CITY FURNISHED OR PROVIDED AS NOTED IN SECTION E. W 10. WITHIN EACH PULLBOX AND SPLICE VAULT, ALL CONDUITS SHALL BE SEALED WITH 4. LOCATION OF ALL UNDERGROUND FACILITITES ARE APPROXIMATE. CONTRACTOR SEALING COMPOUND. ALL GROUND CONNECTIONS SHALL BE COATED WITH PULL EXISTING 96 STRAND SMFO CABLES TO NEW P48 PULLBOX SHALL BE RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING OXIDATION PROHIBITING COMPOUND. PULLBOXES AND SPLICE VAULTS SHALL BE FACILITIES WITHIN THE AREA OF CONSTRUCTION. THE CITY ENGINEER SHALL BE SEALED AFTER ALL CONDUIT ENTRANCES HAVE BEEN MADE. NOTIFIED OF ANY DISCREPENCIES OR CONFLICTS PRIOR TO COMMENCING WORK. Z CONTRACTOR SHALL RELOCATE AND/OR REPLACE ANY LANDSCAPING OR 11. CONTRACTOR SHALL SUPPLY AND INSTALL J" MULE TAPE IN ALL EMPTY CONDUITS. SPRINKLERS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY AND TERMINATE TO 96 STRAND SMFO CABLE IN P48 SPLICE VAULT PER SPLICE SCHEDULE. TERMINATE 12 STRAND SMFO CABLE TO WIC W ENGINEER. 12. THE CONTRACTOR SHALL REPAIR/REPLACE ANY AND ALL DAMAGED LANDSCAPING, INSIDE CONTROLLER CABINET PER SPLICE SCHEDULE. ALL REMAINING FIBERS OF THE NORTH AND SOUTH RUNNING 96 STRAND SMFO CABLES 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING IRRIGATION, SIDEWALK, PAVEMENT OR ROADWAY STRIPING TO THE SATISFACTION OF SURVEY MONUMENTS OR MARKERS DURING CONSTRUCTION. SHALL BE SPLICED. THE ENGINEER. 6. ALL PULL BOXES SHALL BE No. 6E AND CONDUIT SHALL BE 2" GALVANIZED RIGID METAL 13. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT INSTALL 2" CONDUIT RUNNING FROM PULLBOX TO PULLBOX TO CABINET AS SHOWN. PULL INTERCONNECT CABLE OUT OF ORIGINAL CONDUIT, UNLESS OTHERWISE SHOWN. ALL SPLICE VAULTS SHALL BE TYPE P48 48.5"x30.5"x30" DEEP OR POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS FOR THIS © (INSIDE), FIBERGLASS, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS". PULL PROJECT. BOXES AND SPLICE VAULTS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT DETAILS FOR PULL BOX AND SPLICE VAULT INSTALLATION. PROP. R/W PROP. C&G EX. R/W EX. C&G wN O - i �r- wro ( \ `- o N 4 EX. C&G EX. R/W BOULEVARD EX.2-1 /2"C.-12 PR #22 S.I.C. Tr P, / — — — O VALLEY/VINEYARD VALLEY TRAFFIC SIGNAL INTERCONNECT/COMMUNICATION CONSTRUCTION NOTES 10 FURNISH AND INSTALL P48 PULLBOX AND SPLICE CANISTER. L� 20 CUT/DISCONNECT THE 96 STRAND SMFO AND 12 STRAND SMFO CABLE FROM SPLICE CANISTER. REMOVE P48 PULLBOX COMPLETE. W 30 EXTEND ALL OF THE CONDUITS TO THE NEW P48 PULLBOX. NOTE THAT CONDUITS MAY NEED TO BE LOWERED. U PULL EXISTING 96 STRAND SMFO CABLES TO NEW P48 PULLBOX FURNISH AND INSTALL 2" CONDUIT RUNNING FROM P48 PULLBOX TO CONTROLLER CABINET. FURNISH AND INSTALL 12 STRAND SMFO CABLE I= Q AND TERMINATE TO 96 STRAND SMFO CABLE IN P48 SPLICE VAULT PER SPLICE SCHEDULE. TERMINATE 12 STRAND SMFO CABLE TO WIC `V INSIDE CONTROLLER CABINET PER SPLICE SCHEDULE. ALL REMAINING FIBERS OF THE NORTH AND SOUTH RUNNING 96 STRAND SMFO CABLES SHALL BE SPLICED. INSTALL 2" CONDUIT RUNNING FROM PULLBOX TO PULLBOX TO CABINET AS SHOWN. PULL INTERCONNECT CABLE OUT OF ORIGINAL CONDUIT, x © PULL THROUGH NEW CONDUIT TO CABINET. TERMINATE CABLE IN CABINET. co RELOCATE EXISTING AT&T PHONE CABLE AND DEMARCATION BOX TO NEW SIGNAL CONTROLLER CABINET AND TERMINATE PER ORIGINAL w 7Q CONFIGURATION. CONSULT WITH AT&T ON PROPER SPLICING REQUIREMENTS IF NECESSARY TO EXTEND CABLE. REWORK EXISTING CONDUIT \ AS NECESSARY TO EXTEND TO NEW SIGNAL CONTROLLER CABINET. cr- w FR C] REMOVE COMPLETE SEE DRAWING 5141 FOR STREET IMPROVEMENT PLAN SEE DRAWING 5433 FOR TRAFFIC SIGNAL PLAN SEE DRAWING 5435 FOR SIGNING/STRIPNG PLAN