GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ('GREEN
BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.'
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE 'GREEN BOOK', THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC
EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OFA UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER,
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE
LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO
AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL
UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND
SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES
PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED
DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME
OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN 'S' IN THE FACE OF THE CURB AT THE LOCATION OF THE
SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF
THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET
SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE
BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED
BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
BENCH MARK:
THE ELEVATION OF THE SOUTHERLY BCR OF THE CONSTRUCTED
CURB AT THE SOUTHEASTERLY CORNER OF CHERRY AVENUE AND
MEYER CANYON DRIVE, IN THE CITY OF FONTANA, STATE OF
CALIFORNIA WITH AN ELEVATION OF 1247.77 FEET PER STREET
IMPROVEMENT PLANS PREPARED BY HALL AND FOREMAN AND
ASSOCIATES PLAN NO 1432 - 3 AND DATED JANUARY 01, 1987.
BASIS OF BEARING:
THE BEARING OF NORTH 0015'40' EAST OF THE CENTERLINE OF
REDWOOD AVENUE AS SHOWN ON MAP OF TRACT NO. 13643, MAP
BOOK NO. 220/ 98-100, RECORDS OF SAN BERNARDINO COUNTY
HAS BEEN USED AS THE BASIS OF BEARINGS FOR THIS SURVEY.
I
lies
100111 104ol
STREET CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
TOLL FREE -800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
UNAUTHORIZED CHANGES AND USES
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR,
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
NOTES.
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE
CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST OF
THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE
CITY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT
SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO
THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE
PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS
SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S.
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
RELATIONS' "CONSTRUCTION SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS"
OF THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS".
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR
ENGINEER.
NO. REVISION DESCRIPTION DATE ENGR. CITY DATE
UTILITY PROVIDERS
ELECTRICITY
SOUTHERN CALIFORNIA EDISON
7951 REDWOOD AVENUE
FONTANA, CA 92336
909-357-6203
GAS
SOUTHERN CALIFORNIA GAS CO.
SAN DIMAS CA 91773
(800)427-2000
WA TER
FONTANA WATER CO.
15966 ARROW ROUTE
FONTANA, CALIFORNIA 92335
(909) 822-2201
CIVIL ENGINEER
HUI TT-ZOLLARS, INC
3990 CONCOURS, #330
ONTARIO, CA. 91761
PHONE (909) 941-7799
FAX (909) 941-7789
CONTACT: MAURICE MURAD
OWNER/DEVELOPER
OAKMONT INDUSTRIAL GROUP
3520 PIEDMONT ROAD, SUITE 100
ATLANTA, GA 30305
PH: 949-215-3796
CONTACT.• JOHN ATWELL
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
TELEPHONE
AT&T
3939 E CORONADO STREET
ANAHEIM, CA 92807
714-237-6155
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6632
SOILS ENGINEER/GEOTECH
SOUTHERN CALIFORNIA GEOTECHNICAL, INC.
22885 SAW RANCH PARKWAY, SUITE E
YORBA LINDA, CA 92887
PHONE (714) 685-1115
FAX (714) 685-1118
CONTACT: JOHN SEMINARA
QROFESS/ONq \�
H.
c� NO. 33366 =
cr-
EXPIRATION
'*'._ 6-30-2016 •: *,
ow
1 �% ' • CIVIv'•S�OF C0
ABBREVIATIONS
AC .____.. ASPHALT CONCRETE
VC __ VERTICAL CURVE
TP TOP OF PAVEMENT
TC TOP OF CURB
E'LY.____.. EASTERLY
EL . . ELEVATION
ELEC_._..... ELECTRIC
EXIST......_. EXISTING
FL .-___. FLOWLINE
FG __ _- FINISH GRADE
FS .____.. FINISH SURFACE
CF .____.. CURB FACE
GB GRADE BREAK
HP HIGH POINT
INV._.___..... INVERT ELEVATION
TG TOP OF GRATE
CB CATCH BASIN
RD _ ROOF DRAIN
LAT......._.__ LATERAL
LD _ _ LOCAL DEPRESSION
EP._..-..._.. EDGE OF PAVEMENT
COTG .__.. CLEANOUT TOP OF GRATE
SMH... SEWER MANHOLE
S/W SIDEWALK
R/W.-_.._... RIGHT OF WAY
RT. . RIGHT
PCC.__._.... PORTLAND CEMENT CONCRETE
P.I.P.._.._... PROTECT IN PLACE
PROP_._.. PROPOSED
TELE..__.... TELEPHONE
W'LY._._-. WESTERLY
CL .___-. CENTERLINE
DWY_......... DRIVEWAY
C&G CURB AND GUTTER
TB __ TOP OF BERM
TC._..__. TOP OF CURB
TW._____. TOP OF WALL
FL FLOWLINE
ECR.._.-. END CURB RETURN
EP ......... EDGE OF PAVEMENT
FS . FINISHED SURFACE
EG . EXISTING GROUND
TOP OF GRATE
INV... INVERT
GB.._._._. GRADE BREAK
R -.-._. RIDGE LINE
CB.___._. CATCH BASIN
PP . POWER POLE
BCR_.-. BEGIN CURB RETURN
BASELINE AVENUE LEGEND
PROJECT
y=
P
RD ACj�%CC7RjG, Bi
�F
MOLLER AVENUE
N
MEYER CANYON DR j
Lu
Y
V$ HILTON DR.
W
o =
FOO MILL BL VD
VICINITY MAP
NOT TO SCALE
SHEET INDEX MAP
SCALE: 1"=200'
SHEET INDEX
CONSTRUCTION NOTES
QUANTITIES
Oi
CONSTRUCT CONCRETE SIDEWALK PER CITY OF FONTANA STD. NO. 1006...............................................................7,592
2
SF
O2
CONSTRUCT 6.5" MIN. AC PAVEMENT PER DETAIL ON SHEET .2............................................................................
820
SF
O3
CONSTRUCT COMMERCIAL DRIVEWAY PER CITY OF FONTANA STD. NO. 1002..............................................................
3,606
SF
O
SAWCUT AND REMOVE EXISTING AC PAVING.................................................................................................
820
SF
O5
SAWCUT AND REMOVE EXISTING PCC CURB & GUTTER......................................................................................
410
LF
Os
SAWCUT AND REMOVE EXISTING PCC SIDEWALK.............................................................................................
591
SF
O7
REMOVE AND MODIFY EXISTING LANDSCAPE AND IRRIGATION...............................................................................
1
LS
O
RELOCATE EXISTING STREET LIGHT & APPURTENANCES.....................................................................................
1
EA
O9
RELOCATE EXISTING TRAFFIC SIGN, PROVIDE 4' MIN. UNOBSTRUCTED SIDEWALK CLEARANCE ..............................................
5
EA
toREMOVE
EXISTING TREE......................................................................................................................
7
EA
11
PROTECT IN PLACE (ITEM AS INDICATED ON PLAN).........................................................................................
-
12
CONSTRUCT DOUBLE 4' WIDE PARKWAY CULVERT PER SSPWC DWG. 151-2, INLET TYPE 1 ................................................
1
EA
t3
COLD PLANE EXISTING AC MINIMUM 0.15' DEPTH & AC OVERLAY TO MATCH EXISTING ....................................................
851
SF
t4
RELOCATE EXISTING IRRIGATION METER (BY FONTANA WATER COMPANY)..................................................................
1
EA
t5
RELOCATE EXISTING TELEPHONE PEDESTAL (BY OTHERS)...................................................................................
1
EA
16
REMOVE & CAP PVC RISER.................................................................................................................
1
EA
TOLL FREE -800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
UNAUTHORIZED CHANGES AND USES
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR,
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
NOTES.
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE
CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST OF
THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE
CITY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT
SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO
THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE
PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS
SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S.
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
RELATIONS' "CONSTRUCTION SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS"
OF THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS".
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR
ENGINEER.
NO. REVISION DESCRIPTION DATE ENGR. CITY DATE
UTILITY PROVIDERS
ELECTRICITY
SOUTHERN CALIFORNIA EDISON
7951 REDWOOD AVENUE
FONTANA, CA 92336
909-357-6203
GAS
SOUTHERN CALIFORNIA GAS CO.
SAN DIMAS CA 91773
(800)427-2000
WA TER
FONTANA WATER CO.
15966 ARROW ROUTE
FONTANA, CALIFORNIA 92335
(909) 822-2201
CIVIL ENGINEER
HUI TT-ZOLLARS, INC
3990 CONCOURS, #330
ONTARIO, CA. 91761
PHONE (909) 941-7799
FAX (909) 941-7789
CONTACT: MAURICE MURAD
OWNER/DEVELOPER
OAKMONT INDUSTRIAL GROUP
3520 PIEDMONT ROAD, SUITE 100
ATLANTA, GA 30305
PH: 949-215-3796
CONTACT.• JOHN ATWELL
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
TELEPHONE
AT&T
3939 E CORONADO STREET
ANAHEIM, CA 92807
714-237-6155
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-6632
SOILS ENGINEER/GEOTECH
SOUTHERN CALIFORNIA GEOTECHNICAL, INC.
22885 SAW RANCH PARKWAY, SUITE E
YORBA LINDA, CA 92887
PHONE (714) 685-1115
FAX (714) 685-1118
CONTACT: JOHN SEMINARA
QROFESS/ONq \�
H.
c� NO. 33366 =
cr-
EXPIRATION
'*'._ 6-30-2016 •: *,
ow
1 �% ' • CIVIv'•S�OF C0
ABBREVIATIONS
AC .____.. ASPHALT CONCRETE
VC __ VERTICAL CURVE
TP TOP OF PAVEMENT
TC TOP OF CURB
E'LY.____.. EASTERLY
EL . . ELEVATION
ELEC_._..... ELECTRIC
EXIST......_. EXISTING
FL .-___. FLOWLINE
FG __ _- FINISH GRADE
FS .____.. FINISH SURFACE
CF .____.. CURB FACE
GB GRADE BREAK
HP HIGH POINT
INV._.___..... INVERT ELEVATION
TG TOP OF GRATE
CB CATCH BASIN
RD _ ROOF DRAIN
LAT......._.__ LATERAL
LD _ _ LOCAL DEPRESSION
EP._..-..._.. EDGE OF PAVEMENT
COTG .__.. CLEANOUT TOP OF GRATE
SMH... SEWER MANHOLE
S/W SIDEWALK
R/W.-_.._... RIGHT OF WAY
RT. . RIGHT
PCC.__._.... PORTLAND CEMENT CONCRETE
P.I.P.._.._... PROTECT IN PLACE
PROP_._.. PROPOSED
TELE..__.... TELEPHONE
W'LY._._-. WESTERLY
CL .___-. CENTERLINE
DWY_......... DRIVEWAY
C&G CURB AND GUTTER
TB __ TOP OF BERM
TC._..__. TOP OF CURB
TW._____. TOP OF WALL
FL FLOWLINE
ECR.._.-. END CURB RETURN
EP ......... EDGE OF PAVEMENT
FS . FINISHED SURFACE
EG . EXISTING GROUND
TOP OF GRATE
INV... INVERT
GB.._._._. GRADE BREAK
R -.-._. RIDGE LINE
CB.___._. CATCH BASIN
PP . POWER POLE
BCR_.-. BEGIN CURB RETURN
BASELINE AVENUE LEGEND
PROJECT
y=
P
RD ACj�%CC7RjG, Bi
�F
MOLLER AVENUE
N
MEYER CANYON DR j
Lu
Y
V$ HILTON DR.
W
o =
FOO MILL BL VD
VICINITY MAP
NOT TO SCALE
SHEET INDEX MAP
SCALE: 1"=200'
SHEET INDEX
SHEET NO.
DESCRIPTION
1
TITLE SHEET
2
CROSS SECTION AND DETAILS
3
STREET IMPROVEMENT PLAN
s
w
E
G
T
LEGEND
CENTERLINE
RIGHT OF WAY
LOT LINE
EASEMENT
EXISTING SEWER
EXISTING WATER
EXISTING ELECTRICAL
EXISTING GAS
EXISTING TELEPHONE
CITY OF FONTANA, CALIFORNIA
.o
0
STREET OGS PROMC��i EHE PL AH12,
ul
Huitt-Zollars, Inc. Ontario
DRAWN BY:
PARCEL MAP NO. 19653
SCALE:
3990 CONCOURS, SUITE 330 * ONTARIO, CALIFORNIA 91764 * (909) 941-7799
HZ STAFF
CHERRY AVE, MEYER CANYON DRIVE & REDWOOD AVE
TITLE SHEET -CONSTRUCTION NOTES & QUANTITY ESTIMATE
AS SHOWN
W
DESIGNED BY:
DLW
CHECKED BY:PPRO,
M.H.M.
DATE:
11/2015
APPROVED BY MAURICE H. MURAD R.C.E. EXPIRES DATE
33366 6-30-16 3 g
D BY: /
3 -`
DWG. NO.:
5447
1
3
CI ENGINEER R.C.E. 51152 DATE: