Loading...
HomeMy WebLinkAbout5373-11. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK, THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND THE ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES, A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTORS SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE C, SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE 0-1 w SWALES ENTERING OR LEAVING IMPROVEMENTS. m REV. REVISION DESCRIPTION ENGR. DATE CITY DATE Q � N 0 O Dr,",o DIAL TWO WORKING BEFORE DAeq) YS YOU DIG TOLL FREE 1-800-227-2600 o I A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT J Q_ 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34. MINIMUM D -LOAD FOR ALL RCP IS 1350. CITY OF FONTANA, UTILITY NOTIFICATION UST CITY OF FONTANA AT&T 8353 SIERRA AVE 22311 BROOKHURST ST SUITE 203 FONTANA, CA 92335 HUNTINGTON BEACH, CA 92646 (909) 350-6632 (714) 963-7964 SO. CALIF. GAS COMPANY SPRINT 1981 W. LUGONIA AVE 2592 DUPONT DR REDLANDS, CA 92374 IRVINE, CA 92612 (909) 335-7967 (800) 659-9698 EMERGENCIES: (800) 427-2200 TIME WARNER CABLE SO. CALIF. EDISON COMPANY 1500 AUTO CENTER DR 300 N. PEPPER AVE ONTARIO, CA 91761 RIALTO, CA 92376 (909) 975-3439 CITY OF FONTANA STORM DRAIN IMPROVEMENT PLANS TRACT N0. 18939.2 ------- . ......`4,h 1909 820-5598 - UNDERGROUND SUNESYS, LLC 909 875-5100 - TRANSMISSION 1325 PICO ST J106 I 213)637-1233 - PIPELINES CORONA, CA 92881 909 357-6505 -DISTRIBUTION (951) 278-0400 FONTANA WATER COMPANY UNDERGROUND SERVICE ALERT 15966 ARROW BOULEVARD (800) 422-4133 FONTANA, CA 92335 (909) 822-2201 DEVELOPER SOILS ENGINEER LENNAR HOMES OF CALIFORNIA, INC. LEIGHTON AND ASSOCIATES, INC. 980 MONTECITO DRIVE, SUITE 302 17781 COWAN CORONA, CA 92879 IRVINE, CA 92614 TEL (951) 817-3545 TEL (949) 250-1421 FAX 951) 817-3650 FAX (949) 250-1114 LEGEND: INDICATES PROPOSED A.C. PAVEMENT ._ - - - INDICATES CENTERLINE --- INDICATES RIGHT-OF-WAY LINEERY - - - - INDICATES EXISTING IMPROVEMENTS -(1300)--- INDICATES EXISTING CONTOUR LINE AVENUE DIRECTION OF FLOW I L.U.A. LIMITED USE AREA L.O.C. LENGTH ON CURVE L.O.S. LINE OF SIGHT PRIVATE ENGINEER'S NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR / STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE I' OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. UNAUTHORIZED CHANGES AND USES: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. CONSTRUCTION STAKING NOTICE THESE IMPROVEMENT PLANS HAVE BEEN PREPARED WITH THE INTENT THAT THE FIRM OF ALLARD ENGINEERING INC. WILL BE PERFORMING THE CONSTRUCTION STAKING FOR THE COMPLETE PROJECT. HOWEVER, IF ANOTHER ENGINEERING AND/OR SURVEYING FIRM SHOULD BE EMPLOYED TO USE THESE PLANS FOR THE PURPOSE OF CONSTRUCTION STAKING, NOTICE IS HEREBY GIVEN THAT THE FIRM OF ALLARD ENGINEERING INC. WILL NOT ASSUME ANY RESPONSIBILITY FOR ERRORS OR OMISSIONS, WHICH COULD HAVE BEEN AVOIDED, CORRECTED OR MITIGATED IF ALLARD ENGINEERING INC. HAD PERFORMED THE STAKING WORK. SHOULD CONSTRUCTION OF REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT 0 Id 11 E 0 0 WQMP WN #1 t 41 24UNE Ti 40 i -0w 'TRACT BOUNDARY °, \ 1 WQMP .. E� S { 49 50, 26 7 38 ff i i 37 � � N LE 28 - f 43 i 3620 In 29 A4 3 e 35 3 12 { 19 � � � 30 � 45 ° I 34 16 13 i 31 a i t 46 33 r 14 l 16 15 48 47 27 49 50 € _ � i 52 \ t 1 106 55 f 3 a�a . �....4 TRACT BOUNDARY € \ , Prepared For: L ENNAR 980 MONTECITO DRIVE, SUITE 302 CORONA, CA 92879 (951) 817-3545 FAX (951) 817-3650 INDEX MAP SCALE: 1"=80' SHEET INDEX SHEET 1 TITLE SHEET SHEET 2 UNE "B" & "LAT B-1" BASIS OF BEARINGS: THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF SIERRA AVENUE, PER TRACT 17634, M.B. 340/72-73, BEING: N 00'00'12" BENCHMARK: 2" BRASS CAP LOCATED ON THE TOP OF CURB AT THE EASTERLY END OF THE CURB RETURN AT THE NE CORNER OF SIERRA AVE. AND MILLER AVE. ELEVATION: 1364.32 VICINITY MAP NTS THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE THEIR OWN QUANTITIES AND BID A COMPLETE JOB. CONSTRUCTION NOTES• W BWm- TES 1 INSTALL 24" RCP (D -LOAD PER PROFILE) 338 LF 2 INSTALL 12 PVC (SDR -35) 190 LF 3 CONSTRUCT MODIFIED CATCH BASIN PER DETAIL ON SHEET 2 & PER CITY STD. 3004 (WIDTH SHOWN ON PLAN) 2 EA 4 CONSTRUCT MANHOLE PIPE TO PIPE PER CITY STD. 3013 2 EA 5 CONSTRUCT HEADWALL WING TYPE PER CITY STD. 3020 1 EA 6 CONSTRUCT TRASH RACK PER CITY STD. 3021 1 EA 7 INSTALL RIP -RAP PER CALL OUT SHOWN ON PLAN 2.37 CF 8 CONSTRUCT STANDARD TRENCH REPAIR PER CITY STD. 1008 SF 9 CONSTRUCT JUNCTION STRUCTURE PIPE TO RCB PER STANDARD PLANS FOR PUBLIC WORKS CONSTRUCTION STD. PLAN NO. 333-1 HEREON (OR APPROVED EQUAL) 1 EA 10 MANHOLE FRAME AND COVER PRESSURE TYPE PER CITY STD. 3016 1 E Prepared By: ALLARD ENGINEERING Civil Engineering in9 - Land Surveying 9- Land Planning 16866 Seville Avenue Fontana, California 92335 (909) 356-1815 Fax (909) 356-1795 Raymond J. Allard, A.C.E. 36052 Date (expires 6/30/2016) RpFESS/� CITY OF FONTANA CALIFORNIA ��� �o�o �' q<<�� �, STORM DRAIN IMPROVEMMENT PLAN DRAWN BY: TRACT NO. 18939i-2 SCALE: No. 36052 � _ AS NOTED °G Exp. 6/30/16 � DESIGNED BY: MU SPIFFY DATE: _ March, 2016 C ► V i � ��P CHECKED BY: AP OV B : DRAWING NO.: 1 F OF CAt-�F� � DATE: 5 2 CITY E (NEER R.C.E. 51152 Filename: I:\Inland Construction - Gabriella\DWG's\FINAL DESIGN\STORM DRAIN\Phase 2\SD TR -18939-2 SHT 01.dwg