HomeMy WebLinkAbout4738-1rm
CONDUCTOR TABLE
AWG.
CIRCUIT OR
POLE
RUNS
LUMINAIRE
/;�
!
/J \
A
/5\\
/ U \
�
,A
A
/ I V \
m
POLE
PHASE 7
PHASE 8
O
C
TYPE**
HT.
SIG.
LUM.
H. P. S. V.
POLE
PHASE
QUAD
VEHICLE
PED.
MESSAGE
A
B
O
FON26A-4-100
35'
45'
15'
250W
B
2P
W
MAS,MAS,SV-1-T
SP -1 -CS
OA
8'
10'
0
j
POLE ❑3
FON1A 10
10
1 /1
-
1 /1
B
4P
N
TV -1-T
SP -1 -CS
-
13'
4'
❑
FON19A-4-100
35'
25'
15'
250W
B
4P
0
z
0
POLE ❑4
SP -1 -CS
D
1/1
6'
1/1
1/1
FON1A-10
10
N w
POLE ❑5
6P
E
TV -1-T
SP -1 -CS
-
1 /1
1 /1
❑
FON26A-4-100
m
40'
15'
250W
B
6P
E
MAS, MAS, SV- 1-T
SP -1 -CS
CC)
12'
6'
U
POLECK
FON1A-10
10
-
-
-
B
8P
S
TV -1-T
SP -1 -CS
-
POLE ❑7
8'
❑
FON19A-4-100
35'
1 /1
1 /1
1 /1
1 /1
8P
S
MAS,SV- 1-T
SP -1 -CS
DB
6.5'
8'
®
FOWA-10
10
n
POLE
2P
W
TV -1-T
SP -1 -CS
-
11'
4'
z
0
TOTAL
1/1
2/2
4/4
4/4
5/5
4/4
3/3
2/2
1/1
6 PR. #22
-
-
-
2
-
2
2
-
-
-
#10
LUMINAIRE
2
2
-
-
-
2
2
2
2
-
VIDEO
VIDEO CABLE
1
1
-
4
-
2
2
1
1
-
DET.
OPTICOM CABLE
1
1
-
4
-
2
2
1
1
-
CONDUIT SIZE
3"
3"(E)
4"
3"
4"
4"
4"(E)
4"
3"(E)
3"
(E) INDICATES EXISTING CONDUIT WITH PULL ROPE, ALL CONDUCTORS SHALL
BE NEW,
BARRIER
NOT
USED
AVE
F KNOX 5800
❑B
-
LUMINAIRE
PHASE 1
PHASE 2
PHASE 3
PHASE 4
NOT
USED
A
PHASE 5
PHASE 6
PHASE 7
PHASE 8
PHASE DIAGRAM
TRAFFIC SIGNAL GENERAL NOTES:
C
MOUNTING DETAIL
MODEL 711 OPTICAL DETECTOR
1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA
STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002).
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO WORKING DAYS
BEFORE DIGGING.
3. ALL TRAFFIC SIGNAL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID
METAL UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE
BROOKS TYPE P48 WITH EXTENSIONS (OR APPROVED EQUAL), PER SPECIAL PROVISIONS.
INTERCONNECT PULLBOX LIDS SHALL BE LABELED "COMMUNICATIONS".
4. ALL VEHICLE INDICATIONS SHALL BE 12". ALL VEHICLE AND PEDESTRIAN HEADS SHALL
HAVE L.E.D. MODULES AND BE PER SPECIAL PROVISIONS.
5. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING
WITH SOUTHERN CALIFORNIA EDISION COMPANY WELL IN ADVANCE OF NEED.
6. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING
IS OPERATIONAL PER SPECIFICATIONS.
7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT.
8. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
9. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKLER SYSTEMS IF NECESSARY.
10. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A
CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS
FOR THIS PROJECT.
11. AL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK.
12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS AND HARDWARE TO CONSTRUCT
THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXECPT AS NOTED TO
BE CITY FURNISHED, OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS.
13. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE
BORING METHOD, TRENCH REPAIRS SHALL BE PER DETAIL THIS SHEET, AND SPECIAL
PROVISIONS, SECTION E.
AFA File: 816.004 SUM-KNOX-SIG.DWG 9:34 AM 09/15/08
Curb/Berry
or edge of
POLE LOCATION DETAIL
CURB LINE
R/W LINE
EX. 1 1/ 2'C,
(1) EX. 6PR #22
SUMMIT AVE
10 CURB LINE CB
R/W LINE
SNS LEGEND
❑A
AVE
F KNOX 5800
❑B
SUMMIT AVE
F 15600
❑
AVE
F:N KNOX 5700
❑D
AVE
FM. SUMMIT 15500
LUMINAIRE
NEW STREET NAME SIGNS
POLE SCHEDULE
L
STANDARD
MAST ARMS
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
S.N.S.*
PLACEMENT
REMARKS
O
C
TYPE**
HT.
SIG.
LUM.
H. P. S. V.
TYPE
PHASE
QUAD
VEHICLE
PED.
MESSAGE
A
B
O
FON26A-4-100
35'
45'
15'
250W
B
2P
W
MAS,MAS,SV-1-T
SP -1 -CS
OA
8'
10'
F=20'
❑
FON1A 10
10
-
-
-
B
4P
N
TV -1-T
SP -1 -CS
-
13'
4'
❑
FON19A-4-100
35'
25'
15'
250W
B
4P
N
MAS,SV- 1-T
SP -1 -CS
D
13'
6'
®
FON1A-10
10
B
6P
E
TV -1-T
SP -1 -CS
-
9'
10'
❑
FON26A-4-100
35'
40'
15'
250W
B
6P
E
MAS, MAS, SV- 1-T
SP -1 -CS
CC)
12'
6'
F-17.5'
❑
FON1A-10
10
-
-
-
B
8P
S
TV -1-T
SP -1 -CS
-
11'
8'
❑
FON19A-4-100
35'
25'
15'
250W
B
8P
S
MAS,SV- 1-T
SP -1 -CS
DB
6.5'
8'
®
FOWA-10
10
-
B
2P
W
TV -1-T
SP -1 -CS
-
11'
4'
* S.N.S. SHALL BE INSTALLED ON SHAFT MOUNTED CANTILEVER MAST ARMS
** ALL POLES SHALL BE THE DECORATIVE TYPE AND SUPPLIED AND INSTALLED BY THE CONTRACTOR. SIGNAL POLES, DECORATIVE BASE COVER, SIGNAL AND LUMINAIRE
MAST ARM, ANCHOR BOLTS, MAS TENON, LUMINAIRE AND SNS CANTILEVER MAST ARMS SHALL BE PURCHASED BY THE CONTRACTOR FROM SOUTH COAST LIGHTING AND DESIGN
1391 CALLE AVANZADO, SAN CLEMENTE, CA 92673 (949) 276-8855.
34' 34' �k •kna ( Pole -t Y pL c�es� na-�I o n 5 0.� 4- a TRAFFIC SIGNAL CONSTRUCTION NOTES:
22' 22'
CURB LINE S o -for e co m-� 1 v f pole -5.
S-Fa.v� cl cur c�
J r avall4ble upon r'eques+ by ca�-Foc-��n� ❑ INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING
R W LINE d e
alts Q e TYPE "R" CABINET, SOLO PRO DETECTION, AND APPURTENANT EQUIPMENT.
/ �I pr Sou�-1-\ CocxS'F CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD
I
DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECT—
RONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON
THE PLAN.
❑2 INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND
SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS.
B ❑3 INSTALL CITY FURNISHED UNI—DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR,
I ; (MODEL 711 OR EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER.
CB
❑4 INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER DETAIL HEREON AND
AS DIRECTED BY THE ENGINEER.
O6
O z W 5 FURNISH AND INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N.
CB - � z ❑
06P --` --- " -_ -- --- 02 m N ❑6 CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S
-- Y -- 3 EX, 1 1/2 C,
_� ❑5 �/ - '' \ REQUIREMENTS.
Q I �� \ EX. P48 D o* (1) EX, 6PR #22
g 02 �8 (ol
-- _ — ❑7 FURNISH AND INSTALL 2" CONDUIT WITH 2 INTERCONNECT CABLES (6PR. #22).
02 -
- 8 REMOVE EXISTING PULL BOX AND INSTALL NEW #6E PULL BOX.
EX, P48 _ 6E 08� C -
5 EX. 1 1(2-C, - - --- __ __ .-__.._ - ___ _. ❑9 FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE
------ --
�_ -----�--U R3-4 ___ ___ ___ ___ ___ ___ ___ ___ REQUIREMENTS. COORDINATE SERVICE WITH SCE (BURNETTA QUAID 909-357-6121 &
------------------------- - ----------- (1) EX, #2-2 ---
-_ -__- _---_-__ CANERA MILES 909-357-6505, OR TWILA OTTO).
-------------------------
KNOX
- -__ -___ -_ - _ ----- - nJ----
RCP
10 FURNISH AND INSTALL 1 NEW -INTERCONNECT CABLE (6PR. #22) FROM NEW CONTROLLER AT
--- ---- ------------------- ---- v - --
CL RCP SD �8 �� " L -J I �- _12' _; KNOX TO EXISTING CONTROLLER AT LYTLE CREEK RD. (APPROX. 1340') IN NEW 2' CONDUIT
i� a0 I 'X -WALK �D 60 AND EXIST 1.5" CONDUIT. REMOVE EXISTING INTERCONNECT CABLE FROM KNOX AVE. TO
--- -- - - - -cY) - -- -- r (y) v -- LYTLE CREEK RD. AND REROUTE TO NEW CONTROLLER IN NEW 2" CONDUIT.
------------------ --- -------- ---- -- -- -
----------
0
--- -----
11. CITY FURNISHED EQUIPMENT SHALL BE REIMBURSED BY THE DEVELOPER.
07 1p
--------------------------------------------------
- - i
------ -- � R73-3 5
v �
M � Z ' ' 3 M-
4-
L R -m I 04 A
CB �-V D R3- ' 9 SERVICE FEED PONT
--------� � ijij ii 5 � - -- ------------- --- ---- -�--�----- ------1755x3-851- _
03 } 44 4
�0 1 i
--- - / _
— — w — 6P \ o4 w — —
w z �4P 1 8 9 02P
z J ® \ OJ z
J - - - r--- -- - J
6 �/ m
_ o'
LUMINAIRES 2 E--- -- --r- - 9 1
2"C, 2#10
2"C,2#6 ❑ 4 O
SIGNAL 3 5 2 CB
F6 -F1
" PER
CURB LINE R/W LINE PLAN
R/W LINE
22 22 HEADER CUT
(U CURB LINE
> 34' 34' 0.03' LIP
Q I
I
Z I 0.10' MIN. EXISTING
�� AC SURFACING
NEW A.C. ' -
TACK COAT 2 -SACK
ALL EDGES SLURRY BACKFILL
EXISTING CURB (INITIAL POUR TO BE FLUSH
OR - WITH SURROUNDING SURFACE)
CURB AND GUTTER
3" RIGID
METAL CONDUIT
SCALE 1"=20' (INSTALLED WITH 1' MIN. COVER)
CONDUIT RUN TRENCH REPAIR DETAIL
20 10 0 20 40 60 N.T.S.
CROSSINGS IN PAVED CONDITIONS
CITY OF FONTANA
TRAFFIC SIGNAL MAST ARM SIGN LOGO
1/4- Border
Handicap Blue_
2 %2 "
1/4" Black (Non -reflective)
t
LJ CITY OF
ONTANA
Handicap Blue
12"
Grey
(Non -reflective)
Parks
and
,\ Recreation
Brown
White
(Standard 01)
9/16"
3 %4"
12"