Loading...
HomeMy WebLinkAbout5413-7 ROOF PENETRATION GALVANIZED SEE STRUCTURAL FLOW SWITCH REGISTER HVAC REQUIREMENTS SHEETS JOHNSON CONTROLS 10" ► MODEL F62 1. FAN WHEELS SHALL BE COMPLETELY WELDED ALUMINUM. INSTALL PER MFR 10" X 14" REDUCER INSTRUCTIONS 2. FANS SHALL MEET TYPE B CONSTRUCTION AS DEFINED IN AMCA STANDARD EXTEND MIN 12" 99-0401 CLASSIFICATION FOR SPARK RESISTANT CONSTRUCTION. ABOVE ROOF LINE �\ _ / -- _ --____, 3. FAN MOTORS SHALL BE EXPLOSION-PROOF RATED, OF THE HORSEPOWER SHOWN. VENTILATION FAN ,11.— TCB 2-GREENHECK 10 E HEC MOTOR 10"0 NG LVANIILED 4. FANS SHALL BE RATED TO PROVIDE 1300 CFM AT 0.25 IN-WG. MOUNT TO FLOORDUCTO BUILDING WALL 5. FANS SHALL BE MOUNTED TO FLOOR/WALL USING CALDYN TYPE HH VIBRATION ISOLATORS. OO DEFLECT DUCTING OJ +i IL TO BUILDING WALL o 6. DUCTING REGISTERS SHALL HAVE MINIMUM DIMENSIONS OF 12"X 12" FABRICATE TRANSITION FITTINGS FABRICATE FITTINGS AS •' AS REQUIRED TO CONNECT FAN TO DUCTING 7. PROVIDE DUCTING SUPPORT EVERY FIVE (5) FEET FOR VERTICAL AND REQUIRED TO TRANSITION -❑1 HORIZONTAL DUCTING. FROM (E) 2' x 2' INTAKE f 1 — fROUTE DUCTING TO FAN CONNECTION TO NORTHWEST 8. CONTRACTOR SHALL CALIBRATE HVAC SYSTEM (INTAKE AND EXHAUST FLOW BUILDING CORNER SYSTEMS) AFTER INSTALLATION, BUT PRIOR TO ACCEPTANCE. SYSTEM 843.75 843.75 SHALL BE ADJUSTED USING THE INSTALLED DAMPERS TO PROVIDE 1300 CFM 4 <-7n a _ _ _ ° ° �° a ° ° a ° 4 a a SUPPLY TO THE BUILDING WHILE MAINTAINING A POSITIVE PRESSURE WITHIN GALVANIZED �1 THE BUILDING. BUILDING PRESSURE SHALL NOT EXCEED 0.25 IN-WG. a REGISTER ---------------..— a a A 9. SEE ELECTRICAL SHEETS FOR ELECTRICAL SUPPLY AND FLOW SWITCH SECURE DUCTING TO — a CONNECTION REQUIREMENTS. CORE DRILL THROUGH A WALL SEE DETAIL <I FLOOR AS REQ'D FOR Q DUCT PENETRATION Q OJ ' a ° 14"0 GALVANIZED DUCTING a a d � a 14"0 GALVANIZED a 7 A INSTALL ADJUSTABLE Si DUCTING a DAMPER DOWNSTREAM Ii a a OF FLOW SWITCH a a ° ° ON 4 a a FLOW SWITCH JOHNSON CONTROLS MODEL F62 a a. ° INSTALL PER MFR INSTRUCTIONS i SEE ELECTRICAL SHEET FOR INSTALL ADJUSTABLE , WIRING AND ALARMS DAMPER (MEDIATELY a UPSTREAM OF ALL ° a REGISTERS AND O ° ° DUCTING INLETS EXHAUST FAN / ,v a4 GREENHECK MODEL 7 TCB-2-10 W/3/4 HP ► 4 a a 4 MOTOR MOUNT TO I ❑ GALVANIZED WALL REGISTER \ v 11 a ' a 1 d p N a a � 821.75 4 a a a a ' 4 a 4 a a 821.75 4 aA a a \ 4 A SOUTHRIDGE IMPROVEMENT SECTION D SOUTHRIDGE IMPROVEMENT SECTION SCALE: 1" =4' 7 SCALE: 1" =4' WALL 3/8" ALL-THREAD EMBED MIN 4" INTO 4_ CONC (TYP) GALV STEEL DUCT . A. 1/4" X 4" EPDXY ANCHOR El Ap o ° 4 CEILING A 4 A N 4 G - 4 t. N )611- 1/4" SS NUT& BOLT o , ' IM EACH SIDE 1" X 1/8" GALV STEEL III Z-BAR, LENGTH AS REQ'D STRAP BRACKET AS 4 1/4" SS NUT & BOLT MANUFACTURED BY DUCTMATE, OR APPROVED EQUAL a a a 18 GA GALV STEEL STRAP GALV STEEL DUCT 18 GA GALV STEEL STRAP d d a O VERTICAL DUCTING HORIZONTAL DUCTING DUCT MOUNTING DETAIL ) NO SCALE 7 RECORD DRAWING BASED ON FIELD INFORMATION PROVIDED BY HPS MECHANICAL, INC. Do Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA SHOULD CONSTRUCTION OF THE REQUIRED o•�' ssioNq�, MPROVEv1ENTS NOT COMMENCE WITHIN TwoSchaaf Wheeler has , SANITARY SEWER PUMP STATION REPAIRS LEI / • rn DRAWN BY: SCALE: CONSULTING CIVIL ENGINEERS 2 YEARS OF THE DATE OF APPROVAL SHOWN HEREON `� " m No.68813 GMA SOUTHRIDGE PUMP STATION AS SHOWN AND CARRIED FORTH IN A DILIGENT MANNER, THE DIAL TW❑ WORKING 870 MARKET STREET, SUITE 1278 * * DESIGNED BY: IMPROV ENT SECTIONS DATE: CITY ENGINEER MAY REQUIRE REVISIONS TO THE BEFORE I� DAYS BEFORE SAN FRANCISCO, CA 94102 �Q GMA 04/12/13 YOU DIG W YOU DIG (� CIV1� �� PLANS TO BRING THEM INTO CONFORMANCE WITH REV. RECORD DRAWINGS 5/6/15 BLS (415) 433-4848 9TFOF GA��F°� Dated! /� CHECKED BY: A...,. DRAWING NO.: TOLL FREE 1-800-227-2600 r'- i STANDARDS IN EFFECT. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REVISION DESCRIPTION DATE ENGR. CITY DATE BENJAMIN L. SHICK R.C.E. 68 13 `� DATE: C7 S BLS CI 1GINEER R.C.E. 51152 X413