HomeMy WebLinkAbout5413-31 CONTROL DIAGRAM 0 +24VDC -24VDC • H /I A -24VDC +2 V DC HAND • • • SYMBOL DETAIL NOTES: INTRINSICALLY • • DETAIL NOTES: PUMP 1 • �?_ I I. TIME DELAY ADJUSTABLE HOA I ___ I. PRIMARY SCHEMATIC IS DIAGRAMMATIC SAFE RELAY FROM 0-180 SECONDS SET AT ----- FIELD WIRING I CR6-1 CR8-I -1AND REPRESENTATIVE OF REQUIRED LOGIC; • I • CR151 • CRI5-3_71(... 0 SECONDS. A.TO _ • I-6— THE LOGIC SHOWN MAY BE IMPLEMENTED • SECONDARY CONTROL WIRING INSIDE MSB I �--• .�'' PI-1 START PI II USING DISCRETE PARTS OR THROUGH THE L J LOW WATER 2. TIME DELAY ADJUSTABLE CRI-I �.______I USE OF PLC LOGIC; CONTRACTOR SHALL I —I I--- NORMALLY OPEN CONTACT SUBMIT COMPLETE CONTROL WIRING FROM 0-180 SECONDS SET AT 180 SECONDS. CR20-I SCADA SIGNAL DIAGRAM. F52 A— NORMALLY CLOSED CONTACT CR20 • "PUMP PI IN 2. PUMP FAILURE RELAY FROM PUMP LOW HATER 3. SECONDARY CONTROLS 0 AUTOMATIC MODE" STARTER/RVSS; PUMP AS NOTED. INTENDED FOR USE WHEN TIMED CONTACT H r A HAND I PRESSURE TRANSDUCER USE ° NORMALLY CLOSED TIMED OPEN INTRINSICALLY • LS; 3. N.O. CONTACT FROM INTERLOCKED C.B. CRI5-1 SAFE RELAY TIMED CONTACT PUMP 2 • , I ° (MTS) CLOSES UPON TRANSFER TO DISCRETE COMPONENTS. NORMALLY OPEN TIMED CLOSED HOA I • I • CRI6 • CR16-21 I CR7-1 CRq-I SCADA SIGNAL "SECONDARY y EMERGENCY POWER SOURCE. T T TIMED CONTACT NcrL °�° ° AUTO • II • P2 P2-I START P2 II 4. N.O. CONTACT FROM PLC CONTROLLED BY L CONTROL; NIGH HATER" NORMALLY CLOSED TIMED CLOSED • PRESSURE TRANSDUCER; CLOSE UPON .-J CR2-1 �� ---- HATER REACHING DESIGNATED LEVEL; °sr° TIMED CONTACT I II DESIGNATED LEVELS SET PER CIVIL FS1 NORMALLY OPEN TIMED OPEN CR21-I SCADA SIGNALENGINEERS PLAN; ELECTRICAL HIGH HATER " " CR21 • "PUMP P2 IN CONTRACTOR SHALL ADJUST LEVEL CRI5-2 CRI6-1 O 4111) RELAY; TYPE AS INDICATED; XX T AUTOMATIC MODE" SETTINGS PER CIVIL PLANS. I I I • IS RELAY IDENTIFIER. • I 5. UPON HIGH HATER ALARM; ALL PUMPING CR17-1 0 ___ IS CALLED AND SCADA SIGNAL SENT. © � SELECTOR SWITCH; * INDICATES I- -I r 7 I I • TM4 • CONTACT SELECTION. G. ALTERNATOR; CALLS LEAD PUMP, THEN • 1--I I I I CRI • CALLS LAG PUMP; AUTOMATICALLY PRIMARY 4 ROTATES START SEQUENCE; WHEN CALLED • CR17 • I • ---- PILOT LIGHT; "X" INDICATES LENS START LEAD PUMP I I TO STOP PUMPING LEAD PUMP IS SHUT CR18-I © COLOR; R=RED, G=GREEN, SEQUENCE WATER LEVEL I DOWN FIRST; LAG PUMP IS SHUTDOWN T START PI A=AMBER. SECOND. _ • I • TM3-1 . --- 7. N.O. CONTACT FROM MAIN C.B. CLOSES • • • CR18 • • -___-i PILOT LIGHT WITH PUSH-TO-TEST; A -i OI I I L___J CR2 UPON DETECTING POWER LOSS FROM CRIq-� • © "X" INDICATES LENS COLOR; R=RED, LAG PUMP I UTILITY. START P2 G-GREEN, A=AMBER. L HATER LEVEL J ALTERNATOR O6 TM4-� CR1c1 • O 8. TIME DELAY ADJUSTABLE FROM 0-180 s • -----I II n-SCADA SECONDS SET AT 0 SECONDS.CR3 • CR3-2 SIGNAL —9 I o-- MOMENTARY CONTACT NORMALLY CLOSED O "HIGH WATER" q. TIME DELAY ADJUSTABLE FROM 0-180 4 p Lam____ SECONDS SET AT 60 SECONDS. SCHEMATIC CONTROL DIAGRAM (SECONDARY BARBEE & LOCUST) O o—_ MOMENTARY CONTACT HIGH WATER NORMALLY OPEN 10. AT LOW HATER LEVEL, PUMP CONTROLS NO SCALE 0 ____ ARE ACTIVATED AND REMAIN ACTIVATED HOA HAND-OFF-AUTOMATIC SWITCH. CR4-2 SCADA SIGNAL UNTIL LOW HATER RELAY OPENS. PLC PROGRAMMABLE LOGIC CONTROL. II CR4 • • „ II. SEE DETAIL I/E5.O. LOW HATER" DETAIL NOTES: O 4 NP HIGH PRESSURE. - 12. N.O. CONTACTS FROM INTRUSION ALARMS I. FLOAT SWITCH CABLE PART OF FLOAT SWITCH ASSEMBLY; COORDINATE CABLE LENGTH WITH VENDOR; CABLE TERMINATES IN CONTROL CR3-I p LOW HATER AT EACH PEDESTAL DOORS; NUMBER OF DEVICES PER PLANS; CONNECT EACH PULLBOX. HIGH WATER-< I II--• DEVICE IN PARALLEL; ALARM IS SENT START • 2. PRESSURE TRANSMITTER CABLE PART OF PRESSURE TRANSMITTER; COORDINATE CABLE LENGTH WITH VENDOR; CABLE TERMINATES IN SEQUENCE CR4-1 1 CR5-1H HATER TIME UPON ANY DOOR OPENING. CONTROL PULLBOX. 00 II— • • DELAY RELAY 13. N.O. CONTACT FROM PLC CONTROLLED BY 3. MINI CAS SIGNAL CONDUCTORS PART OF MOTOR POWER CABLE; SIGNAL CONDUCTORS TERMINATE IN PUMP RECEPTACLE; SEE 2/E2.3. PRESSURE TRANSDUCER; CLOSES UPON FAILURE OF TRANSDUCER 4. CONDUCTORS FROM PUMP RECEPTACLE TO MINI CAS TRANSCEIVER. • CR5 • HOLDING RELAY 14. N.O. CONTACTS FROM INTRUSION ALARMS 5. CONDUCTORS FROM CONTROL PULLBOX TO PEDESTAL CONTROL SECTION. PEDESTAL AT DRYWELL DOORS OR PANEL DOORS AS CONTROL TM1-1 APPLICABLE; NUMBER OF DEVICES PER G. INDEPENDENT REDUNDANT CONTROLS; SEE DETAIL 3/E6.0. SECTION • • . • CR6 • PLANS; CONNECT EACH DEVICE IN PARALLEL; ALARM IS SENT UPON ANY r HIGH HATER TIME DOOR OPENING; PROVIDE TERMINAL TM2-I DELAY START BLOCKS TO CONNECT UP TO 10 PARALLEL • • CR7 • DEVICES. r 7 r --1 O2 I 15. N.O. CONTACT FROM MINI CAS UNIT FOR; CR8-21 SCADA SIGNAL CLOSES UPON FAILURE OF PUMP; PUMP AS • •--) HCR8 • T "PUMP PI FAILURE" NOTED. O PLC 15 I L J L- _-J O 2 CRq-2 SCADA SIGNAL • .-11—• CRq • "PUMP P2 FAILURE" INTRINSIC I5 T I BARRIER r--- ---� --- ---� H H I MINI CAS MINI CAS SYSTEM SYSTEM • CR10-I SCADA SIGNAL C INTRINSIC CRIO • "LOSS OF CONTROL BARRIER POWER" 3 I • II CRIT • CRI I SIGNAL L T "TRANSFER TO - EMERGENCY POWER TO PUMP4 TO PUMP I STARTERS 5 O 1, 0 0 0 STARTERS CR12-I SCADA SIGNAL I IH CR12 r • • • 12 AL DE TA SILTRUSION 1 0 0 H H H CABLESPLICE P L SPLICE TYPICAL H II CONCRETE O GNAL T I L —-I —II— O .. 0 4 0 0 II I • I I CR13 • CR13-1 SCADA SIGNAL OVERHEAT OVERHEAT 13 PRIMARY CONTROLLER o 0SENSOR MOISTURE SENSOR T 'FAILURE' I PRESSURE SENSOR ■ • SENSOR ISTURE O FLOAT SWITCH TRANSMITTER (LOW WATER) 24VDC (FROM PLC) II (F52) • CRI • CR14-� SCADA SIGNAL T 0 POWER LOSS" FLOAT SWITCH- RECORD DRAWING I (FSH WATER) BASED ON FIELD INFORMATION PROVIDED BY HPS MECHANICAL, INC. SCHEMATIC CONTROL DIAGRAM (PRIMARY BARBEE & LOCUST) O CONTROL SYSTEM BLOCK DIAGRAM (BARBEE & LOCUST) FEHR ENGINEERING COMPANY, INC. 62—A HANGAR WAY 0 WATSONALLE, CALIFORNIA, 95076 1211? PHONE: (831) 786-0373 NO SCALE 0 NO SCALE FAX: (831) 786-8523 (Inc. EMAIL: FEC®FEHRINC.COM CONSULTING ELECTRICAL ENGINEERS S R-L-B FE JOB No. 11081.00 Du AT �O pROFESSIO,�,. Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA SHOULD CONSTRUCTION OF THE REQUIRED L `` «' 'IMPROVEMENTS NOT COMMENCE WITHIN TWO 1( 1) S chaaf Wheeler 4,��P� E. P/Asir , SANITARY SEWER PUMP STATION REPAIRS 11111 CONSULTING CIVIL ENGINEERS o DRAWN BY: SCALE: YEARS OF THE DATE OF APPROVAL SHOWN HEREON j No. 014906 C.L. CONTROL DIAGRAM AS SHOWN AND CARRIED FORTH IN A DILIGENT MANNER, THE DIAL PbTWO WORKING 870 MARKET STREET, SUITE 1278 DESIGNED BY: BARBEE & LOCUST STATIONS DATE: —� rBEFORE �1'`r � DAYS BEFORE EXP. 30 JUNE 13 rk CITY ENGINEER MAY REQUIRE REVISIONS TO THE YOU DIG 10 SAN FRANCISCO, CA 94102 F �, T.P. 5/6/15 YOU DIG FCTR\GP PLANS TO BRING THEM INTO CONFORMANCE WITH TOLL FREE 1-800-227-2600 REV. (415) 433-4848 `rTgpF E�F \P Date : 4-11-13 CHECKED BY: APP-'�'=�•� l :,' �� DATE/Z . / DRAWING No.: 31 STANDARDS IN EFFECT. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REVISION DESCRIPTION DATE ENGR. CITY DATE CM_If"' PINKERTON i3;!� D / Y- '�- E6.O T.P. CI ENGINEER R.C.E. 51152 33 54/3