Loading...
HomeMy WebLinkAbout5413-3 A 4 I / f B 1 4 SHEET NOTES: THE AREA WITHIN THE EXISTING BLOCK WALL IS AVAILABLE -7-4 FOR USE BY THE CONTRACTOR FOR CONSTRUCTION ,' .M21 1 ,'� (E) AC PAVEMENT (E) POWER PULL BOX STAGING AND STORAGE . NO EQUIPMENT OR MATERIALS Oi��'`: `2 j SHALL BE STORED OUTSIDE OF THE WALLS WITHOUT \ WRITTEN P RMI I N FROM THE CITY. •���•�� l (E) TRANSFORMER E S O O �`�r:♦di REMOVE (E) LIMITS OF (E) AND CONCRETE et ELBOW (TYP OF 3)FLARED ROOF PAD TO REMAIN ,� i/— , ir �gii J1 l / ��•�,/r I `� TEST& PATCH (E) PVC • EDGE OF (E) PAVEMENT N. ♦./� ' WETWELL LINING N 1 ���� SEE SPECIFICATION F -1 F _ _1 ���� EXHIBIT B FOR PHOTOS C._ (E) MH COVER4. TO REMAIN,TYP if .i �� El 41 �� 1....:. •/ (E) GRAVEL SURFACE v �•7 \... (E) AC PAVEMENT �• 0 �< <0 c r� o, �� (E) VACUUM RELIEF ASSEMBLY TO REMAIN f (E) WETWELL REMOVE (E) GENERATOR SOUTHRIDGE PUMP ROOM DEMOLITION PLAN SCALE:1" =4' (E) CONC. PAD TO REMAIN (E) HOSE BIB TO REMAIN iLci_I l'zf ,; 1--- f- r _ _ _____ _., (E) BLOCK WALL TO A SAWCUT& REMOVE ,REMAIN (E) CONC PAD AS A AI REMOVE (E) MOTORS REQ'D TO INSTALL �I�� AND CONCRETE PAD, J /I 0 BYPASS CONNECTION , Q /�SEE DETAIL VØ ® / REMOVE (E) FAN - :''-- - ij:: M A & DUCTING REMOVE AND REPLACE (E) AC 0 PAVEMENT. GRADE AND SLOPE (E) SSMH, ADJUST RIM AS 7 TO DRAIN THROUGH ENTRANCE "/// / NECESSARY TO BE FLUSH r GATES, SEE DETAIL 10 �/ 4 i WITH FINAL GRADE NEP :! f0 f f f / s 1,:; REMOVE (E) CONTROL I w i PANELS, SEE (E) WATER SERVICE0 TO REMAIN ELECTRICAL SHEETS — — , / / ? ) R , '' (EADJUFOST RIM ASCEMAIN NECESSARYMANHOLETO T T BE FLUSH WITH FINAL GRADE CONFORM TO CITY STANDARD I DETAILS L _ _I (E) CONCRETE SIDEWALK A (E) ACCESS HATCH0 TO REMAIN 4 ‘,4 U) U)(� U) SOUTHRIDGE DEMOLITION SITE PLAN SCALE:1" =4' MCC ROOM DEMOLITION PLAN SCALE:1"=4' RECORD DRAWING BASED ON FIELD INFORMATION PROVIDED BY HPS MECHANICAL, INC. Do 0 Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA SHOULD CONSTRUCTION OF THE REQUIRED LE's o,v0FE /04/ IMPROVEMENTS NOT COMv1ENCE WITHIN TWO Schaaf P wheeler Q� SANITARY SEWER PUMP STATION REPAIRS r� YEARS OF THE DATE OF APPROVAL SHOWN HEREON *' CONSULTING CIVIL ENGINEERS ri ���� DRAWN BY. SCALE. m .0.68813 rn GMA SOUTHRIDGE PUMP STATION As SHOWN AND CARRIED FORTH IN A DILIGENT MANNER, THE DIAL TWO WORKING 870 MARKET STREET, SUITE 1278 �° DESIGNED BY: DATE: CITY ENGINEER MAY REQUIRE REVISIONS TO THE BEFORE Ik DAYS BEFORE SAN FRANCISCO CA 94102 * * DEMOLITION PLAN YOU DIG w YOU DIG d>, CIV1� a GMA 77 04/12/13 PLANS TO BRING THEM INTO CONFORMANCE WITH TOLL FREE 1-800-227-2600 REV. 1 RECORD DRAWINGS 5/6/15 BLS (415) 433-4848 97F OF cA��FOP Date 'CHECKED BY: �AP2RCI D B% �`� DRAWING NO.: 3 A PUBLIC SERVICE BY UNDERGROUNDDATE: PI.`'- STANDARDS IN EFFECT. SERVICE ALERT REVISION DESCRIPTION DATE ENGR. CITY DATE B NJAMIN L. SHICK R.C.E. 68 13 BLS CITY i WEER R.C.E. 51152 C3 3 DI •nA• 54/3