HomeMy WebLinkAbout5413-21 GENERAL SINGLE LINE NOTES ( ) FEEDER SCHEDULE PANELBOARD SCHEDULE 0 SHEET NOTES A. ALL ELECTRICAL SHOWN IS NEN, U.O.N. FDR No. CONDUIT AND CONDUCTORS REMARK I. COORDINATE WITH UTILITY TO RECONNECT (N) I. NEMA I BUS GOA, 30 VOLT120/208 SWITCHBOARD WITH THE (E) UTILITY SERVICE. 16. 3#8 $ I#10 GROUND CONDUCTORS PART OF POWER B. ALL CIRCUIT BREAKERS ARE 3-POLE, U.O.N. SF01 2"C., 4#3/0. I#6 GND. SP1 CIRCUIT AND 2#I0 CONDUCTORS PART OF CONTROL MOUNT ® MAINS 60A CB CONNECTED LOAD 2. RATE CIRCUIT BREAKERS MCP'S AT 25KAIC CIRCUIT. SF02 2"C., 4#3/0. 1#6 GND. NQOD MINIMUM. 17. CIRCUIT TO SPI; SEE PANEL SCHEDULE. C. VOLTAGE DESIGNATIONS: (U.O.N.) A. I .C. 10,000 FEED A A KV7.3 20.2 240-1 = 240/120V-IPH-3WIRE SF03 2"C., 3#3/0. I#6 GND. 480-I = 480V-IPH-2WIRE VOLT-AMPS VOLT—AMPS 3. MOUNTED WITHIN SWITCHBOARD. SF04 I„C., 3#8, 1#10 GND. $ 2#10T T 18. CABLE SUPPORT GRIP, HEAVY DUTY STAINLESS 208Y = 205/120V-3PH-4 WIRE USE A 8 C TRIP TRIP A B C USE 4. CORE DRILL THROUGH FLOOR TO MAKE WAY FOR STEEL, OFFSET EYE SPLIT MESH. ROD CLOSING 480Y = 480/277V-3PH-41A1IRE SF05 I"C., 3#8, 1#10 GND. $ 2#10 0N CONDUIT RUN; SEE I/E2.2. "KELLUMS" OR APPROVED EQUAL 480 A = 480V-3PH-3 WIRE ELECTRICAL ROOM LIGHTING 856 20/1 I 2 20/I 540 RECEPTACLES ( ) SF06 31110, 1#10 GND. CONTROLS 500 3 4 360 „ Iq. COORDINATE FS MOUNTING HEIGHT WITH CIVIL D. "KA” AT CIRCUIT BREAKERS DENOTES MINIMUM REQUIRED INTERRUPTING SF07 4#6, 1#10 GND. GEN. HEATER 1200 5 G 500 PUMP RM. LIGHTS 5. HAZARDOUS DUTY RECEPTACLE WITH MATCHING CAPACITY IN AMPS (x 1000). 3 „ GEN. BATT. 800 „ 7 8 300 EXT. LIGHTS t FAN PLUG TO MOTOR CONNECTION; 60A, 480V, 3 POLE PLANS. SF08 /4 C., 3#12, 1#12 GND. AND EQUIPMENT GROUND; PROVIDE 2 SPACE ONLY IPSP c1 10 200 SUMP PUMP REC. AUXILIARY/PILOT CONTACTS FOR SIGNAL 20. FLOAT SWITCH; MECHANICAL TILT FLOAT SW ITCH; E. SPO AT BREAKER DENOTES: PROVIDE MOUNTING SPACE $ HARDWARE SFOs %"C., 3#12, 1#12 GND. I1 12 1000 MCC SPACE HEATER, CONNECTION; MOUNT TO NALL BOX WITH 70° ENM-I0 LEVEL REGULATOR BY ITT FLYGT. PROVIDE FOR FUTURE 3-POLE BREAKER OF RATINGS INDICATED. SFIO 1"C., 3#8, I#10 GND. +1 2#10 0. 13 14 �,, 1000 A/C UNIT REC. WITH INTRINSICALLY SAFE CONTROLS. INCLINED INLET/WALL BOX; CLASS I DIVISION 2; IS IG IPSP SPACE ONLY POLYESTER HOUSING; MELTRIC DXN SERIES OR SFII 3/4"C., 3#10, 1#10 GND. GENERATOR HEATER 4 BATTERY CHARGER 17 15 APPROVED EQUAL; LOCATE RECEPTACLE ADJACENT 21. SIGNAL CIRCUIT THROUGH WETWELL NALL; SF12 %"C., 4#12 GENERATOR START SIGNAL 4 FAIL ALARM H 1 20 TO PUMP CONTROLLED. PENETRATE NALL AS SHOWN FOR POWER CORD. 21 22 SSOI 3/4"C.O. TELEPHONE „, 23 24 „ %, G. FLEXIBLE CABLE PART OF MOTOR; I CABLE WITH 22. SUBMERSIBLE PRESSURE TRANSDUCER; GE 5502 I"C.O. 6 �� 1686 500 1200 CONNECTED LOADS 1640 560 1500 �� 3#6 POWER CONDUCTORS, 2#10 CONTROL "PTX-1280" SERIES; 4-20mA OUTPUT; PROVIDE WITH CONDUCTORS; 1#8 EQUIPMENT GROUND CONDUCTOR; INTRINSICALLY SAFE CONTROLS; COORDINATE CABLE 5503 2"C.O• 1#10 "GROUND COMPLETE CONDUCTOR" IS NOT USED; LENGTH WITH FIELD CONDITIONS; SEE CIVIL PLANS SSO4 I"C., 2#14 PRESSURE TRANSDUCER CONNECT CABLE TO (N) PLUG. FOR INSTALLATION REQUIREMENTS. SSO5 2"C., 4#14 FLOAT SWITCH CABLES 7. DIESEL FUEL POWERED EMERGENCY GENERATOR SET 23. CONTROLS PULLBOX; SEE DETAIL 2/E2.4. 100KN; SEE ELECTRICAL SPECIFICATION. 24. COMBINATION MOTOR STARTER (NEMA 00); SEE 8. SUMP PUMP; SEE 2/E2.2. DETAIL 6/E5.0. ci. 1#4 B.C. TO GROUNDING ELECTRODE; SEE DETAIL 25. SEE CIVIL PLANS FOR NET WELL PENETRATION 4/E5.0. REQUIREMENTS. 10. TOTAL CONNECTED LOAD IS 78KVA OR 94 AMP AT 26. CONDUIT FOR TRANSDUCER CABLE; SEE DETAIL 480V, 30. I/E6.2. -(5) SCE PRIMARY SERVICE II. START SIGNAL; SEE DETAILS 3/E2.3 + I/E6.2. 27. CONDUIT FOR FLOAT SWITCH CABLES; SEE DETAIL I/E6.2. 12. SCHEMATIC DIAGRAM ILLUSTRATES CONCEPTUAL WIRING; CONTRACTOR SHALL ADHERE TO EQUIPMENT MANUFACTURERS SPECIFIC INSTALLATION �` J < (E) SCE TRANSFORMER INSTRUCTIONS; PROVIDE WIRING DIAGRAM SUBMITTAL FOR REVIEW +4 APPROVAL PRIOR TO INSTALLATION. n - — 7 13. FANS RUN CONTINUOUSLY TO MAINTAIN AIR CHANGE 1 K (5) PULLBOX PBl , ,, REQUIREMENTS; SEE DETAIL I/E5.0 SIMILAR. L _ Isc=25KAIC (INCLUDING 14. EMERGENCY OFF PUSH BUTTON; MUSHROOM HEAD; MOTOR CONTRIBUTION) RED WITH "EMERGENCY SHUT OFF" ENGRAVED IN 0 / 10 / HEAD; 41MM DIAMETER; 2 POSITION MANUAL 1 ,( SEE 2/E2.4 FOR PUSH/PULL SNITCH; TWO N.O. CONTACTS 120V, 3 0 CONDUIT AMPS MINIMUM; NON-ILLUMINATED; MOUNTED IN 4” X 1.._ REQUIREMENTS 4" X 2"D. NEMA 4X STAINLESS STEEL ENCLOSURE ( Q AT 48" AFF. LABEL SNITCH WITH NAME OF PUMP .► © ( (N) MCC i__ RNUMBER!"PUMP PX" WHERE "X" IS SPECIFIC (N) MSB 480/277V, 30, 4W, NET WELL NEMA I RATED CLASS I, PUMP r- _ _ s DIVISION 1 15. 1 5/8" X 1 5/8" STAINLESS STEEL STRUT; SECURED )200 LOCATION TO PUMP PEDESTAL. 25KAIC / I'\ — 21 MCP 7 Lc) rTh TI o I.< SF02 / 2) n STARTER T2-- i _ 480V ® - 7 - •• 3P1-1200 ® �1 T3--J U.0.N. Aft n DRY WELL ; 40 TYPICAL FOR +24VDC ‘41 • /- k ALL CORDS (FROM MCC (N) ATS, 200A, 3�; F CONTROLS CTION ^ 25KAIC MINIMUM IN WET WELL GM • NEMA 1 ) r SOLID STATE EMERGENCY Q L STARTER CONTROL GENERATOR BOARD TYPICAL I �_ - - l� SECONDARY — O2 o 2 - E6.2 CONTROL RELAY 1 24VDC 7 `i Q OC F 10; TYPICAL • -I f--- + I I I I I I TYPICAL EACH MOTOR 0 6----I I--- LI- 13 3 50 50 50 ) 30 (N) MCC, 200A MINIMUM, INPUTS IMCP MCP CB CB CB CB 480V, 30, 3W, NEMA I TYPICAL EACH MOTORO PRIMARY 2 24VDC ONLY 0 0C F'2 CONTROL RELAY 0 3 >L ® ® 0 m PUMP MOTOR > -- - I ---• f- 4 480 p O RESET CONTROL 13 J TRANSFORMER X5P1 TYPICAL _ ) I RELAY 14 IN-BYPASS c[!;1 : . (y '•y 15KVA; 4.8%Z (MIN.) / L@/ Er1GN-FJ+TOR 14 I I208Y � � q5o . ■111 . .15 ) 96 - FAULT NCn ^ r-Th (� '�ECE q8 - I-- FAULT (NO) LL U `_ o 0 o I -- I O u 'u u 'u I i I -- SRI LC )_! 0 0 0 I AM PUMP FAILURE SRI-1 • • 0 ) SEE PANEL SCHEDULE / TO CONTROLS T EFI EF2 PUMP PI PUMP P2 PUMP P3 I 480V, 30, S--- - • 480V, 30 480V, 30 480V, 3�, 480V, 30, 20HP - 3/4HP 3/4HP 2OHP 2OHP - - (1.6FLA) (1.6FLA) (27FLA) (27FLA) (27FLA) I — 13 13 RECORD DRAWING PANEL SPI CS) RVSS SCHEMATIC DIAGRAM BASED ON FIELD INFORMATION CO (N) SINGLE LINE DIAGRAM (SOUTH RIDGE) 2 NO SCALE PROVIDED BY HPS MECHANICAL, INC. SOUTHRIDGE IMPROVEMENT SECTION FEHR ENGINEERING COMPANY, INC. Y NO SCALE NO SCALE 62—A HANGAR WAWATSOhmLLE, CALIFORNIA,WA 95076 PHONE: (831) 786-0373 FAX: (831) 786-8523 C Inc. EMAIL: FEC©FEHRINC.COM CONSULTING ELECTRICAL ENGINEERS -�/ C SR-L-B FE JOB No. 11081.00 Do SHOULD CONSTRUCTION OF THE REQUIRED A LENT ��oQaOFESSIpHq� � Prepared Under The Supervision Of : CITY Of FONTANA, CALIFORNIA IMPROVEMENTS NOT COMMENCE WITHIN TWO Schaaf P Wheeler ��`) P5 E P,N�� �? SANITARY SEWER PUMP STATION REPAIRS YEARS OF THE DATE OF APPROVAL SHOWN HEREON `� CONSULTING CIVIL ENGINEERS o DRAWN BY: SCALE. I No. 014906 z SOUTHRIDGE IMPROVEMENT AS SHOWN AND CARRIED FORTH IN A DILIGENT MANNER, THE DIAL I�� TWO WORKING 870 MARKET STREET, SUITE 1278 C.L./ PLAN DATE: BEFORE �� ' I� DAYS BEFORE - EXP. 30 JUNE 13 DESIGNED BY: CITY ENGINEER MAY REQUIRE REVISIONS TO THE SAN FRANCISCO CA 94102 YOU DIG Y� YOU DIG F`FCTR1GP T.P. _ 5/6/15 PLANS TO BRING THEM INTO CONFORMANCE WITH TOLL FREE 1-800-227-2600 ® (415) 433-4848 sTq �P ,(11141 Date : 4-11-13 CHECKED BY: APPR� • / DRAWING No.: 21 STANDARDS IN EFFECT. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REVISION DESCRIPTION DATE ENGR. CITY DATE °F CP``F THOMAS PINKERTON � � DATE(Z'• Yr E2.3 T.P. CITY ENGINES R.C.E. 51152 33