HomeMy WebLinkAbout4077-16 , i PROTECTIVE BARRIER ! FOR UNDERGROUND DISTRIBUTION STRUCTURES i iTSTK IONARRIER NOTES; ARCHITECTURE,INC. ! I _ 1, Structures will normally be installed only in non- traffic areas. Barriers to be used where +---f-- '� construction hos exposed equipment to traffic. 1 2, Top of bafflers to be smooth cut and top edges to be rounded. r i _®4/7ki - —_ `POLE OR t + 3'� VENT 3, One barrier to be removable when overhead obstacles prevent equipment removal by ' j M//y0" I crane. �..--i-- t — i _ d OUNDAENT/ �_ \ 4. Adequate clearance must be provided for doors, cooling coils, eta 12575 San Jacinto Ave,San Jacinto,aallfomla 92583-5318 —� - — FOUNDATION 5. Barricades, as shown, Indicate typical requirements. Field conditions will necessitate Phone:951.925;2504 Fax:951.925.0244.Email:stk@stkinc.com VERIZON Telephone Service Requirements for New Construction 4'-' I24• Vz // ,k )V changes for adequate equipment protection. Approval in the field from the underground 24T I I inspector is required for all barricade installations. MIN ' 6, When specified on working drawing, a 6' (minimum height) curb may be Installed In TYPIC-®�—q� SEE — I 4.-6"--•-1 place of barriers. This curb must be at least 6' thick and its front face located 36' CONSULTANT: VERIZON Representative: Frank Angustain Telephone No. (760) 245 —0330 (7/11/2005) •-4'-sem- NOTE 7 IMAX. I minimum (or as specified on drawing) from the equipment foundation. MAX. 7. Increase to 36- minimum when any pad 1s being installed (door side only). Owner/Developer: Fire Station#79(Duncan Cyn. Road) PLAN PLAN POLE OR VENT C/o Carol Greska EQUIPMENT FOUNDATION VERIZON California,inc. requests your cooperation in providing the items checked below to insure timely service REF. UGS 830 DECAL 91 delivery of all your telephone service needs at the following address:TBD 14168-91 NEW 1/85 VERIZON WORK ORDER: 520-9PRO2GR- 074 Please provide the items checked below as requested by your VERIZON Representative: [X] Backboard Size: W:4" L:8" D: 3/4 BARRIER [X]Ground Gauge(AWG):�6 TO BE ONE OF THE FOLLOWING: 30' 1) Provide and place a solid copper ground wire from the telephone protector box to the electrical ground 1)4' GALV. STEEL PIPE (1/4" MIN. WALL) source,providing a common bond with a separate clamp.Clamp to be accessible and to be installed by FILLED WITH CONCRETE a licensed electrical contractor(See NEC Article 250-81 a or c,250-115a,250-117), 2)RAILROAD RAIL (90 LB MIN), OR 51 14.75 GRADE Underground Service Feed AMERICAN STD. BEAM (5' x 3' x 1/2") i��it ��i y�Nno.N [X]Conduit Size:2-4" 3)a" x 8' REINF. CONCRETE 1)PVC conduit GTS8342 (Non-Corrugated)or equivalent. 4)S EEACO OVAL PRIOR 2)Conduit to be buried to a minimum covered depth of 24"from final grade on private property. Minimum of 30" 12"separation from power when in joint trench. _1- 3)All conduits to be left clean,dry,and free of debris or any other obstructions. Unusable conduits shall be replaced at the developers/owners expense. –sd H6- 4)All conduit bends shall have a minimum radius of 24"for 2"duct and 48"for 4"duct. Condulets not accepted. BARRIER 5)%"Polypropylene pull line or equivalent required. DETAIL 6)Conduit to be placed from telco room to P/I (NIA)Utility Box(s) Size: [ ]Other: [X]See attached diagram; 2-4"conduit from property-line to MPOE/Primary Demarcation Point UDERGROUND LEGEND: Aerial Service FeedA UNDERGROUND "SERVICE CONNECTION - COMMON" [N/A]Weather Head -CONDUIT - DEVELOPER TO PROVIDE CONDUIT 1) Weather head to be placed approximately 20"above final grade. 2) Separation of VERIZON and power attachments at buildings shall be at a minimum of 12". MATERIAL AND CONSTRUCT. VERIZON TO REIMBURSE [N/A) Utility Box(s) Size: [ 1 Other: DEVELOPER FOR CONDUIT MATERIAL AT VERIZON'S (N/A)See attached diagram FINAL GRADE CURRENT COSTS. TO BE DEEDED TO VERIZON BY BILL OF SALE. Upon completing the above items,please complete the bottom portion of this form and return it to your VERiZON representative two(2)weeks prior to requesting telephone service to the above address. Should z 12" Min. well Tamped UNDERGROUND "SERVICE CONNECTION-SEPERATE" PROJECT FOR: you have any additional questions or are interested in other VERIZON products or services,please contact p • - -CONDUIT - DEVELOPER TO PROVIDE MATERIAL AND your VERIZON representative. .L o Earth free of rock CONSTRUCT. Please complete and return to: Mand debris or 3" CITY OF • Min, Concrete, VERIZON California, inc. 1 } :..,...,:..:•,...:- Iy. ...:.. TELEPHONE TERMINAL CABINET - PROVIDED AND C^16071 Mojave Drive,Bldg.A Select Material INSTALLED BY DEVELOPER. SEE NOTE 2. i ONTANA Victorville,CA 92362Attn:Network Engineering&Planning-CASI4NTD well tamped Earth FAX (760)245-0330 free of rock and debris TELEPHONE PULL BOX - PROVIDED AND INSTALLED Owner/Developer: Telephone Number -�- 4'*:tom'•'•.• '• BY DEVELOPER. Address: City; State: Zip Code: 4*�' TELEPHONE MANHOLE PROVIDED AND INSTALLED PROJECT NAME: PER S.C. EDISON SPEC 0 BY DEVELOPER. * Not completing or providing the above checked items may delay service to the above address VERTICAL SEPERATION 0 DEVELOPER TO PLACE PULL ROPE. FIRE STATION FINAL GRADE Q LOT NUMBER. # 79 Wl NM NOTES: 1. CONDUIT TO HAVE NOT MORE THAN (2) 90' BENDS IN ANY 5075 DUNCAN CANYON RD. 5 ONE SECTION. FONTANA, CA. 0 M 2. TELEPHONE TERMINAL CABINET, 14 1/2" W x 25" L } y..CDO• :''. 1)0x 6" D. MULTi-METAL HOUSING (WITH LOCK HASP 1.'' . : i ' �-Bedding FOR GTE PROVIDED LOCK). MOUNTED FLUSH o ' i o_ W 12" OR NON FLUSH ON THE EXTERIOR OF BUILDING >- z ~ I- I=- --� 4" �--- Min. well Tamped 1- W z Q o VERIZON NOTES PER S.C. EDISON SPEC Earth free of rock WITH 3/4" PLYWOOD BACK BOARD. USE ONLY Q W oce and debris or 3" WEATHER PROOF HOUSING. MINIMUM GA. STEEL ce a o o m Min. Concrete. FOR BOX 14 GA. FOR LID 16 GA. < no z o HORIZONTAL SEPERATiON rrrr�* Ri�9 •imi ii— °z °� VERIZON CALIFOA 0 o a O FINAL GRADE LOCATION �e o v zo Z Ca EXCHANGE C.O. >O < - — Z ISSUE DATE APPROVALS CL = Q W CCI UQ o O m W F- N m I Z W Z • DWGA SIZE AREA GENERAL MANAGER C Lip Q, U = rn I • Select Material DWG NO. RELATED DWG'S. w)RK ORDER = i– LL ` well tamped Earth AT o co o z • ' ��� 4- free of rock and debris w co � W I- < �, co W M -� 4 �-- Bedding ce Z a Q W SERVICE ENTRANCE Q Q z 0 a W TELEPHONE ONLY P. 1- < �- D-< oce (A) (2) 4' PVC CONDUIT SCI-IEDULE 40 OR GT-42 Si) c� o 8 o_ DETAIL A TYPICAL TRENCH (B) MINIMUM 30" OF COVER. VERIZON CALFORNIA (C) PROVIDE PULL LINE IN ENTRANCE CONDUIT LOCATION 3/8" PULL ROPE. ISSUE INFORMATION: EXCHANGE Co ISSUE DATE APPROVALS (D) ENTRANCE CONDUIT MUST BE 12' FROM DATE: INFORMATION: POWER IN SAME TRENCH. 11/16/05 PLAN CHECK DM1G SIZE (E) ENTRANCE CONDUIT SHOULD NOT EXCEED n2 IAD 2006 PLVISIOCHECK ECK AREA GENERAL MANAGER A DWG NO. RELATED DWG's WORK ORDER 150' OR CONTAIN MORE THAN TWO (2) 90' AT PLAN CHECK SWEEP BANDS WITHOUT A PULL BOX - AMAY 2006 REVISION OR AS SHOWN ON PRINT. MAY 18,2006 REVISION CHECK (F) (I) PULL BOX 3'x5'x4' QUICKSET, BROOKS, OR EQUIVALENT (PROVIDE TRAFFIC COVER). REVISION V2-- p.s5 t3u iN_"T CONTRACTOR NOTES TYPICAL INTERNAL REQUIREMENTS I. All conduit sweeps and bends with a radius of less than 50 feet (A) ADEQUATE WORKING SPACE - PROPER LIGHTING, CLEAN AND ACCESSIBLE WITH will be encased in concrete. A MINIMUM OF 30' WORKING SPACE IN FRONT 2. Conduit bends in trench line that is to be provided and placed OF EQUIPMENT. by the developer will not have less than 12 feet 6 inch radius (B) 4'x8'x3/4" OR SIZE AS REQUIRED, PLYWOOD SHEET INFORMATION: (unless otherwise specified). Conduit which enters a building BACKBOARD MOUNTED ON WALL, OR AS will not have a radius of less than 36 Inches. MARKED ON PRINT. PROJECT NO.: - 3. Place ground rod provided by Verizon Telephone Company at riser (C) INDIVIDUALLY 20 AMP FUSED, 120 VOLT SCALE: AS NOTED pole (only if schedule 40 PVC is used). 60 CYCLE A.C. DOUBLE OUTLET LOCATED DATE: DECEMBER 2, 2005 4. Verizon Telephone approved material may be ordered from the AT TELEPHONE BACKBOARD. PLOT DATE: following manufacturers) (D) PROVIDE ACCESS TO UFER OR METALLIC COLD DRAWING NAME: WATER PIPE GROUND WITH #6 WIRE OR ACCESS MANHOLE, PULL BOXES, E PADS GT 42 CONDUIT TO EARTH DRIVEN GROUND RODS. SEAL: Associated Concrete Products Calpipe 4301 W. Macarthur Street 515 E. 88th. Place g15-7-:;iESSanta Ana, CA 92704 Los Angeles, Ca. 90003 I 714/549-3111 800-778-8086 ,!-i„.,4 - i, calpipeeaol.com ,t Jensen Precast, Incorporated N°'C22977 14221 San Bernardino Avenue d,� REN. :s:- Fontana, CA 92335 714/350-4111 6” 6" 94,OF CAL"? Utility Vault Company, Inc. P.O. Box 1390 -------n _ _O — a - O_ — M------ - Fontana, CA 92335 �t .zr 714/350-2675 ------- ----' SHEET TITLE: ----'° - -° - �° — ° - -- VERIZON I16 1/2" I 12" I I 12' I 16 I/2" I t f f f f NOTES/DETAILS AND PLAN TYP. PULL BOX RACKING 5. Developer or Developer's contractor to provide all manhole 3' X 5' X 4' racking. SHEET NO.: A0.3 VERIZON PLAN VERIZON NOTES AND DETAILS DRAWING NUMBER 4077 16 of 66