IRRIGATION
IRRIGATION NOTES
1. THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN
CLARIFICATION ONLY AND SHALL BE INSTALLED IN ADJACENT PLANTING AREAS.
2. DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE DRAWINGS WHEN IT IS
OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE DIFFERENCES EXIST AND SHOULD BE
BROUGHT TO THE ATTENTION OF THE OWNERS AUTHORIZED REPRESENTATIVE. IN THE EVENT THAT THIS
NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR
REVISIONS NECESSARY.
3. SYSTEM DESIGN IS BASED ON MINIMUM OPERATING PRESSURE SHOWN AT EACH POINT OF CONNECTION
WITH MAXIMUM GPM DEMAND SPECIFIED. IRRIGATION CONTRACTOR SHALL VERIFY ALL PRESSURES ON
SITE, PRIOR TO CONSTRUCTION, TO OWNER'S CONSTRUCTION REPRESENTATIVE.
4. IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE
DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, CURBS, ETC. HE SHALL COORDINATE ALL HIS
WOR( WITH THE GENERAL CONTRACTOR AND OTHER SUB -CONTRACTORS FOR LOCATION OF PIPE
SLEEVES THROUGH WALLS, UNDER ROADS, PAVING AND STRUCTURES.
5. IN ADDITION TO THE SLEEVES SHOWN ON THE PLAN, THE IRRIGATION CONTRACTOR SHALL BE
RESPONSIBLE FOR THE INSTALLATION OF ADDITIONAL SLEEVES OF SUFFICIENT SIZE UNDER ALL PAVED
AREAS PRIOR TO PAVING UPON APPROVAL OF THE OWNER'S REPRESENTATIVE, IF REQUIRED TO OPERATE
SYSTEMS.
6. IRRIGATION CONTRACTOR SHALL FLUSH ALL LINES AND ADJUST ALL HEADS FOR MAXIMUM PERFORMANCE
AND TO PREVENT OVERSPRAY ONTO WALKS, STREETS, AND BUILDINGS AS MUCH AS POSSIBLE. THIS
SHALL INCLUDE SELECTING THE BEST NOZZLE RADIUS TO FIT UNUSUAL SITE CONDITIONS FOR APPROVAL
PURPOSES AT NO EXTRA CHARGE. CALL LANDSCAPE ARCHITECT 48 HOURS IN ADVANCE FOR ANY
COVERAGE TESTS.
7. QUALITY CONTROL OBSERVATION SEQUENCES ARE FOUND IN THE SPECIFICATIONS.
S. MAINLINE SHOWN FOR GRAPHIC CLARITY ONLY. CONTRACTOR TO PLACE MAINLINE IN ADJACENT
PLANTER. CONTRACTOR SHALL NOT INSTALL MAINLINE PIPING UNDER WALL FOOTINGS, COLUMN POST,
OR LIGHTING FOOTINGS. CONTRACTOR SHALL MAINTAIN A MIN. OF 12" CLEARANCE FROM ABOVE ITEMS.
9. CLEAN-UP ON A DAILY BASIS PER OWNER'S REPRESENTATIVE'S APPROVAL
Underground Service Alert
Cail: TOLL FREE
1-800
,b
422-4133
1 WO WORKING DAYS BEFORE YOU DIG
IRRIGATION LEGEND
2' DOMESTIC WATER METER BY SBCWD. DEVELOPER TO PAY ALL
MPW
FEES AND PERMITS. REFER TO TR. #116495 STREET UTILITY PLANS
,L MANUFACTURER
MODEL NUMBER
DESCRIPTION
RAQ1U$ G.P.M. EU
500 SERIES
_d RAINBIRD
1812 -SAM -PRS -50
POP -UP -SPRAY HEAD
5' .10
30
PROPOSED
0 RAINBIRD
1812 -SAM -PRS -5H
POP -UP -SPRAY HEAD
5' 20
30
33DNP/33DK
14 RAINBIRD
1812-SAM-PRS-6VAN
POP -UP -SPRAY HEAD
6' .40
30
H NIBCO
.� RAINBIRD
1812 -SAM -PRS -80
POP -UP -SPRAY HEAD
6 .30
30
10 WILKINS
• RAINBIRD
1812 -SAM -PRS -SH
POP -UP -SPRAY HEAD
6 .50
30
FEBCO_
X RAINBIRD
1812 -SAM -PRS -OF
POP -UP -SPRAY HEAD
8' 1.00
30
MAINLINE (CL. 315): 311 475 L.F. 0
RAINBIRD
1812-SAM-PRS-8VAN
POP -UP -SPRAY HEAD
8' .70
30
SUPERIOR
Is. RAINSIRD
1812 -SAM -PRS -10Q
POP -UP -SPRAY HEAD
10' .40
30
® DATA INDUSTRIAL
V RAINBIRD
1812-SAM-PRS-IOH
POP -UP -SPRAY HEAD
10' .80
30
® SUPERIOR
♦ RAINBIRD
1812 -SAM -PRS -10F
POP -UP -SPRAY HEAD
10' 1.60
30
21/2" 8 L.F. ®
38
GPM
,84
IRRIGATION HEAD PRESSURE:
0 RAINBIRD
�j►, RAINBIRD
1812-SAM-PRS-10VAN
POP -UP -SPRAY HEAD
10' .80
30
FITTING LOSSES (100/6 OF SUBTOTAL):
3.53
(ESTIMATED) ELEVATION LOSSES/GAINS (ELEV. X.433)
00.61
RAINBIRD
1812 -SAM -PRS -120
POP -UP -SPRAY HEAD
12' .70
30
TORO
RAINBIRD
1812 -SAM -PRS -12H
POP -UP -SPRAY HEAD
12' 1.30
30
APPROVED
O RAINBIRD
1812 -SAM -PRS -12F
POP -UP -SPRAY HEAD
12' 2.60
30
NECESSARY.
RAINBIRD
1812-SAM-PRS-12VAN
POP -UP -SPRAY HEAD
12' .70
30
APPROVED
At RAINBIRD
1812 -SAM -PRS -150
POP -UP -SPRAY HEAD
15' .90
30
• • • • • • - APPROVED
* RAINBIRD
1812 -SAM -PRS -15H
POP -UP -SPRAY HEAD
15' 1.90
30
APPROVED
CD RAINBIRD
1812 -SAM -PRS -15F
POP -UP -SPRAY HEAD
15' 3.70
30
'i' RAINBIRD
1812SAM-PRS-15VAN
POP -UP -SPRAY HEAD
15' .90
30
0 HUNTER
PGJ-00N6-A-V
STREAM ROTOR
19-20 .85
30
m HUNTER
PGJ-OW6-A-V
STREAM ROTOR
22-25 1.70
30
0 HUNTER
PGJ-OW6-A-V
STREAM ROTOR
29-34 3.70
30
NOTES@
1. CONTRACTOR TO ADJUST THE RADIUS TO PROVIDE 100% COVERAGE AND TO REDUCE OVERTHROW ONTO WALLS AND WALKS.
2. CONTRACTOR TO INSTALL PCS SCREENS WHEREVER REQUIRED TO ADJUST THE RADIUS TO PROVIDE 100%
COVERAGE TO REDUCE OVERTHROW ONTO WALLS AND WALKS.
3. ALL HEADS LOCATED IN TURF AREAS TO BE INSTALLED ON 6" POP -UPS. USE RAINBIRD 1806 BODIES.
4. LANDSCAPE CONTRACTOR TO VERIFY ALL EXISTING
LINES ON JOBSITE PRIOR TO START OF CONSTRUCTION.
CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED BY HIS WORK. CONTRACTOR IS ALSO RESPONSIBLE
FOR REPAIRING ANY IRRIGATION LINES/SPRINKLER HEADS & EXISTING LANDSCAPE AREAS THAT ARE DAMAGED
DURING CONSTRUCTION
VALVE SIZING KEY
GPM--• 10 VALVE #
3/4■ VALVE SIZE
I
J POINT OF CONNECTION
CONTRACTOR TO MAKE POINT OF CONNECTION IMMEDIATELY DOWNSTREAM
"J OF PROPOSED 2' DOMESTIC WATER METER (BY OTHERS). 2" BACK FLOW,
11/4" FLOW SENSOR, 2" MASTER VALVE, AND LINE SIZE GATE VALVE. REFER
W TO UTILITY PLANS FOR MORE INFORMATION. EXTEND PRESSURE MAINLINE
J TO VALVES AS SHOWN.
EXISTING STATIC PRESSURE: 102-108 P.S.I.
Z SYSTEM DESIGN PRESSURE: 75 P.S.I.
MAXIMUM G.P.M. DEMAND: 50 G.P.M.
AUTOMATIC CONTROLLER MATERIALS LIST:
• TORO'SENTINAL' MODEL NO. SSAK48PS16NS1, 48 STATION FIELD SATELLITE
CONTROLLER
• PROVIDE SENSOR INPUT BOARDSHUT-FF((FFSIB MODEL #995-63 (TO INTERFACE WITH
FLOW METER AND RA• GROUND ROD & SURGIE PROTECTION FOR EACH SATELLITE CONTROLLER
• ALL RADIO EQUIPMENT MUST BE COMPATIBLE WITH VHF
• PROVIDE RAINMASTER 32 PC "PIGTAIL" FOR REMOTE CONTROL OPERATION
PLAN CROSS REFERENCE
FOR NOTES AND LEGENDS, SEE THIS SHEET
FOR CORRESPONDING CONSTRUCTION PLAN, SEE SHEET L-2
FOR CORRESPONDING PLANTING PLAN, SEE SHEET L-8
FOR IRRIGATION DETAILS, SEE SHEET L-7
r -rd
2' DOMESTIC WATER METER BY SBCWD. DEVELOPER TO PAY ALL
MPW
FEES AND PERMITS. REFER TO TR. #116495 STREET UTILITY PLANS
STATIC PRESSURE HIGH: 108
FOR SERVICE LINE LOCATION
T-113
LINE -SIZE GATE VALVE
500 SERIES
2" PRESSURE REGULATOR DEVICE
825Y -BV -200
V REDUCED PRESSURE BACKFLOW, BACKFLOW ENCLOSURE:
STRONG BOX MODEL #ESBBC-45SS - SEE PLAN FOR LOCATION.
950 SERIES
BRASS ELECTRIC REMOTE CONTROL VALVE, SIZE AS SHOWN
FM1.25B
1.1/4" FLOW METER
3000 SERIES
2" NORMALLY CLOSED ELECTRIC GLOBE (MASTER VALVE)
33DNP/33DK
QUICK COUPLING VALVE (SUPPLY (2) KEYS TOTAL)
SENTINEL
TORO'SENTINEL' 48 STATION CONTROLLER
CL. 315 PVC
MAINLINE, SIZE AS SHOWN. PROVIDE MIN. 18" COVER IN LANDSCAPED
GPM
AREAS. PROVIDE MIN. 24" COVER BELOW PAVING SUB -BASE.
SCH. 40 PVC
LATERAL LINE, SIZE AS SHOWN. 12" MIN. COVER
SCH. 40 PVC
SLEEVES, SIZED 2X LARGER THAN PIPE TO BE INSERTED, MIN.
FLOW SENSOR: 11/4" 0
COVER AS REQUIRED OR AS SHOWN.
SCH. 40 PVC
4' ERWISE VES,NOTMIN. COVER AS REQUIRED UNLESS
POINT OF
CONNECTION
VALVE SIZING KEY
GPM--• 10 VALVE #
3/4■ VALVE SIZE
I
J POINT OF CONNECTION
CONTRACTOR TO MAKE POINT OF CONNECTION IMMEDIATELY DOWNSTREAM
"J OF PROPOSED 2' DOMESTIC WATER METER (BY OTHERS). 2" BACK FLOW,
11/4" FLOW SENSOR, 2" MASTER VALVE, AND LINE SIZE GATE VALVE. REFER
W TO UTILITY PLANS FOR MORE INFORMATION. EXTEND PRESSURE MAINLINE
J TO VALVES AS SHOWN.
EXISTING STATIC PRESSURE: 102-108 P.S.I.
Z SYSTEM DESIGN PRESSURE: 75 P.S.I.
MAXIMUM G.P.M. DEMAND: 50 G.P.M.
AUTOMATIC CONTROLLER MATERIALS LIST:
• TORO'SENTINAL' MODEL NO. SSAK48PS16NS1, 48 STATION FIELD SATELLITE
CONTROLLER
• PROVIDE SENSOR INPUT BOARDSHUT-FF((FFSIB MODEL #995-63 (TO INTERFACE WITH
FLOW METER AND RA• GROUND ROD & SURGIE PROTECTION FOR EACH SATELLITE CONTROLLER
• ALL RADIO EQUIPMENT MUST BE COMPATIBLE WITH VHF
• PROVIDE RAINMASTER 32 PC "PIGTAIL" FOR REMOTE CONTROL OPERATION
PLAN CROSS REFERENCE
FOR NOTES AND LEGENDS, SEE THIS SHEET
FOR CORRESPONDING CONSTRUCTION PLAN, SEE SHEET L-2
FOR CORRESPONDING PLANTING PLAN, SEE SHEET L-8
FOR IRRIGATION DETAILS, SEE SHEET L-7
r -rd
PROJECT: SYCAMORE HILLS PARK
• ' . TO VALVES
MPW
SYCAMORE HILLS BARK
STATIC PRESSURE HIGH: 108
LOW: 102
TRA 916495-240T 106
•
r
m:
DESIGNED BY:
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
PHONE NUMBER: (909) 875-1804
12/13/04
CHECKED BY:
VALVE STATION/GPM: STATION: 13
GPM: 38
P.S.I. LOSS:
DOMESTIC SERVICE
ITEM:
WATER METER SIZE: 2" 0
38
TO RESTROOM ,
B
�
FACILITY AND
GPM
D
BACKFLOW DEVICE: 2" 0
DRINKING FOUNTAIN
GPM
12.00
FLOW SENSOR: 11/4" 0
38
�0
3.30
POINT OF
CONNECTION
DETAIL
PROJECT: SYCAMORE HILLS PARK
BY:
MPW
SYCAMORE HILLS BARK
STATIC PRESSURE HIGH: 108
LOW: 102
TRA 916495-240T 106
SOURCE OF INFORMATION: PEGGY
DATE:
DESIGNED BY:
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
PHONE NUMBER: (909) 875-1804
12/13/04
CHECKED BY:
VALVE STATION/GPM: STATION: 13
GPM: 38
P.S.I. LOSS:
6
ITEM:
WATER METER SIZE: 2" 0
38
GPM
1.90
PRESSURE REGULATOR: 2" 0
38
GPM
4.00
BACKFLOW DEVICE: 2" 0
38
GPM
12.00
FLOW SENSOR: 11/4" 0
38
GPM
3.30
MASTER VALVE: 2" 0
38
GPM
.82
GATE VALVE(S): 2 3" 0
38
GPM
2.00
MAINLINE (CL. 315): 311 475 L.F. 0
38
GPM
1.37
AUTOMATIC VALVE SIZE: 2110
38
GPM
.82
LATERAL LINE SIZE: 3/4" 85 L.F. 0
8
GPM
4.37
1" 18 L.F. 0
11
GPM
.73
11/4" 85 L.F. 0
21
GPM
2,12
11/2" 53 L.F.0
28
GPM
1,06
21/2" 8 L.F. ®
38
GPM
,84
IRRIGATION HEAD PRESSURE:
30.00
SYSTEM LOSSES SUBTOTAL:
35.33
FITTING LOSSES (100/6 OF SUBTOTAL):
3.53
(ESTIMATED) ELEVATION LOSSES/GAINS (ELEV. X.433)
00.61
TOTAL SYSTEM LOSSES:
68.86
AVAILABLE PRESSURE (LOW):
102.00
(-) DEFICIT OR (+) RESIDUAL PRESSURE:
(+)33.14
`CONTRACTOR TO SET PRESSURE REGULATOR
TO A SYSTEM DESIGN
PRESSURE OF 65 PSI CONTRACTOR TO FIELD ADJUST REGULATOR
AS
NECESSARY.
CITY OF FONTANA, CALIFORNIA
°a"wN BY:
SYCAMORE HILLS BARK
SCALE
N.A.
TRA 916495-240T 106
DATE:
DESIGNED BY:
12/13/04
CHECKED BY:
APPROVED BY:
DATE:75
DING. NO.:
6
CITY ENGI R.C.E. 51152 EXP. DATE 1 /05
12
LANDSCAPE
ARCHITECTURE
SITE PLANNING
10221-A Trademark St.
Rancho Cucamonga, CA 91730
(909) 484-2800
Fax [909)484-2802
Richard Krunwiede
CA Lic. *2834
AZ Lic. $ 29115
W Lic. # 446
TX. Lic. #1884
L�
12/28/04
1"=20'
0328-4B
L-6
B OF 12 SHTS.