3752-10
DRAWING NOTES I. SITE LIGHTING WIPING SHALL BE # 10 TN- WTHWN-CU. UNLESS OTHERWISE NOTED. M"AJM 3/4" PVC SCHEDULE 40 UNDERGROUND CONDUIT INCLUDED A GREEN GROUND WIRE. SIZE PER NEC TABLE 250-95. INSTALL ALL UNDERGROUND CONDUIT PER NEC TABLE 300-5. 2. OVERSIZING OF WIRE AND DUCTS ACCOUNTS FOR VOLTAGE DROP AND FUTURE USE. EA(DELTA) IS VOLTAGE DROP. 3. SPLICES AND TAPS SHALL BE MADE ONLY N PULL BOXES OR LIGHT FIXTURES. CONNECTIONS AT OR NEAR GROUND LEVEL AND UP TO I FT. ABOVE FOOTINGS SHALL BE COVERED WITH 3M tt3570 OR #2210 VINYL MASTIC INSULATION PADS OR BUC14ANAN-BCAP WATER RESISTANT WIRE CONNECTOR. 4. EXTERIOR EQUPMENTS, J -BOXES AND RECEPTACLES SHALL BE WEATHERPROOF. ALL COVERS SHALL INSTALL N UP POSITION WHEN OPEN. 5. SITE UTILITY DISTRIBUTION FOR SERVING ELECTRIC IS TO BE NSTAI I PER CONSTRUCTION DRAWINGS ENGINEEPED AND PROVIDED BY THE UTLITY CONSULTANTS. 6. CONTRACTOR RESPONSIBLE FOR ANY AND ALL INSPECTIONS. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PEPMTS AND INSPECTIONS THAT ARE REQUIRED FOR COMPLETION OF THE CONSTRUCTION. 7. UNDERGROUND PULL BOXES ARE BES CONCRETE PRODUCTS #C9E 00-5/8"X 17-V4' X 17 HIGM, WITH J -I BOLTS TEL, (888) 783-5055 CONCRETE PULL BOX WITH C90 (SOLID CONCRETE LID WITH LIFT HOLE) MARKING ON COVER IS 'ELECTRIC'. PROVDE 6' GRAVEL BELOW BOX FOR DRAINAGE. PULL BOXES MAY BE ADDED TO FACLITATE WIRE PULLING LOCATE N PLANTER AREAS. (SEE DETAL- I, ON SKEET E-2) 8. REFER TO "CONTROL WIRNG SCHEMATIC - OUTDOOR LIGHTING" 9. ALL EQUIPMENT SHALL BE MOUNTED AND SUPPORTED ACCORDING TO THE OSHA REG UREMENTS. 10. PROVIDE ALL MATERIALS, LABOR, AND PERFORM ALL TASKS NECESSARY TO ACHIEVE A PROPERLY OPERATING ELECTRICAL SYSTEM. II. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (I )YEAR AFTER DATE OF ACCEPTANCE BY OWNER. ANY WORK, MATERIAL OR E XJDMEN'T FOUND TO BE FALLTY DURING THAT PERIOD SHALL BE CORRECTED AT THE EXPENSE OF THE ELEC. CONTRACTOR. 12. PROVIDE THE OWNER WITH ONE (D SET OF COMPLETE ELECTRICAL "AS BUILT" AT THE COMPLETION OF THE JOB. 13. THE WORK COVERED ON THESE DRAWINGS SHALL INCLUDE THE FURNIISHNG OF ALL LABOR, MATERIALS, TRANSPORTATION, TOOLS, FEES AND PERMITS REQUIRED FOR THE INSTALLATION OF A COMPLETE AND OPERATING F9 ECTOCAL SYSTEM DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EVERY DETAIL. 14. ALL WORK SHALL COMPLY WITH THE APPLICABLE RULES OF THE 1999 NATIONAL ELECTRICAL CODE, NATIONAL FIRE CODES AND LOCAL ELECTRICAL CODES AS ADOPTED BY THE GOVERNING MUNMCPAUTY. 15. CONDUCTORS SHALL BE INSTALLED N CODE APPROVED RACEWAYS. IMC AND RMC MAY BE USED INDOORS AND OUTDOORS. EMT MAY BE USED IN INDOOR DRY LOCATIONS. TAPE WRAPPED IMC OR SCHEDULE 40 PVC (WITH CODE SIZED GROUND WIRE SHALL BE USED BELOW GRADE OR N CONCRETE SLAB. TRANSITION FROM BELOW GRADE PVC SHALL BE TAPE WRAPPED IMC OR RMC. 16. ALL ELECTRICAL EQUIPMENT, BREAKER, AND SWITCH DRECTORES SHALL BE PROPERLY LABELED. M ALL EXPOSED PARTS OF ELECTRICAL EQUIPMENT SHALL BE COMPLETELY AND THOROUGHLY LY CLEANED AND FREE FROM CEMENT, PLASTER, PANT, ETC. ALL SCRATCHES ARE TO BE REFINISHED N AN ACCEPTABLE MANNER. 18. ALL LIGHTING FIXTURES SHALL BE NEW AND NSTAIIED WITH THE NECESSARY FITTING AND MOUNTING ATTAC11401ENTS FOR COMPLETE INSTALLATION. 19. ELECTRICAL SYSTEM LAYOUT'S ARE GENE -RALLY DIAGRAMMATIC. EXACT ROUTING OF WIRING, OUTLETS, AND ECNT TO BE COVERED BY STRUCTURAL CONDITIONS AND OBSTRUCTION. 20. ALL OPERATING MANUAL, BROCHURES, CATALOGS, ETC. SHALL BE TURNED OVER TO THE OWNER AT JOB COMPLETION. 21, ELECTRICAL CONTRACTOR MUST DISCONNECT CIRC UT BREAKERS BEFORE MAINTENANCE OR LAND CHANGING FOR U'LIGHT OR NGROUND FIXTURES. 22. ELECTRICAL CONTRACTOR SHALL INSTALL A 3/16" POLYROPYLENE PULL LINE N ALL EMPTY SPARE CONDUITS. FOR SITE LI(5HTIN6 ^IRINC7 L= -61= -ND 010 THHN/THIN GROUNZP SYMBOL NUMBER OF METALLIC �-METALLIG CONDUIT CIRC. BRKR• COPPER BOND pgRE CONDUIT CONNECT TO RE -BAR GON XTOR5 CONDUIT AMPS HIRE # EMERGENCY POWER 2 3/4" #10 3/4" 15 14 EMT 3 3/4" #10 3/4" 20 12 WIRING CONCEALED IN Eo VOLTAGE DROP 30 10 15A -IP 4 3/4" #10 3/4" i� ® FLOURESCENT DOWNLC4T -- - - EXPOSED WRING WP WEATI-E12PROOF 40 10 Q 5 1" #10 1" o AUTO n® WITH ALUMINUM BASE COVER (PANEL PI,CKTS 2 E 4) 60 10 41 444/ 6 I" #10 111 100 8 LOW VOLTAGE 7 1 #10 I " 200 6 AN g 1 #10 1„ 400 2 8 EARLY OFF KIM# G632-42PL24OV.-* �-- �� 600 1 1-1/4" CONDUIT) * COLOR SELECT BY OWNER PL-T42W/ SINGLE RECEPTACLE (+15") 800 O 2OA-2P QUANTITY OF CONDUC- DIAGRAM SYMBOLS O3811. 1000 00 UNDERGROUND GONDUIT MIN. 3/4" CAP STUB -LP SUCH THAT TOP OF CAP IS FLUSH WITH FINISHED GRADE TURF GROUND COVER�j )V f V )V V FIV.SI-ED GRADE �- DRIVEN VT X 18* NIPPLE RIGID GAVAN17FD CONDUT CONDUT CAP--�� UNDERGROUND NTS STUB -LOCATOR -�- POLE HAND HOLE WITH ALUM BASE COVER GROUND LUGS (3)#3 TIES N TOP (4) ANCHOR BOLTS a 5' OF POST BASE W/ DRYPACK BY LIGHT POLE MANUFACTURER T 30' FINISHED GRADE 711".. 1 IIII ISI III II ` ni III nl nI CONDUIT AS REQUIRED REFER TO DETAIL 0 ON p SHEET L5 24' 2 POLE BASE FIXTURE sA E-2 J NTS S.C.E. 3' C.O. LANDING LUGS COMBINATION ROGATION CONTROLER EPI ELECTRICAL SERVICE PEDESTAL 24.75' W. X 26' D. X 48" H. TEL': (800) 860-6157 rWN PUP tt USP -IL -F2200 -124 -TB -SD -STAN -ESS STEEL - PHOTOCELL, TEST SWITCH, TIME SWITCH 1 #4 CU TO DRIVEN 14.4 PI -8 14.4 4 E 6 POLE RELAYS -20 AMPS GROUND ROD 5/8" DIA. X 12'& PI -12 200A -2P BUSSMANN # JJN 200AF. 120/240V. PH.,3W. - 200 AMPS. FUSE SWITCH 42,000 AJ.0 CONNECT TO RE -BAR H.O.A. CONCRETE 2 VVRNG CONCEALED IN J K L EMERGENCY POWER ®LIGHTING A Q IRRIGATION CONTROLERj O CELNG OR WALL EMT 20A -P L H PI -4 CHANDELIERS 0 WIRING CONCEALED IN Eo VOLTAGE DROP EXIT 15A -IP FLR, OR UNDERGROUND TB PI -2 eDETAIL Y i� ® FLOURESCENT DOWNLC4T -- - - EXPOSED WRING WP WEATI-E12PROOF 40 DRAWING NOTE Q OUTSIDE WALL LIGHT PI -24 CIRCUIT IDENTIFICATION AL o AUTO n® WITH ALUMINUM BASE COVER (PANEL PI,CKTS 2 E 4) CO TEST Q DRAWING REVISION �� BATHROOM WALL LIGHT 20A -2P WIRE E CONDUT LV LOW VOLTAGE 123 PILI 8 �1 CU -1.25' (3 CONDUCTORS COPPER AN I WITH ALUMINUM BASE GOVER 0 FLOURESCENT LIGHT PI -3 8 EARLY OFF KIM# G632-42PL24OV.-* �-- �� FLOURESCENT LIGHT 1-1/4" CONDUIT) * COLOR SELECT BY OWNER PL-T42W/ SINGLE RECEPTACLE (+15") Q SMOKE DETECTOR 2OA-2P QUANTITY OF CONDUC- DIAGRAM SYMBOLS O3811. DUPLEX RECEPTACLE (+15") Q PI -5 8 PANEELBOARD(OR BREAKDOWN OF CIRCUIT BREAKERS SHOWN) 6.E. LAMP #F38/2D/827/4P/38VA RECEPTACLE, 208 OR 240V. 3 I --3 � STUB -OUT ® CONTROLLER(OR BREAKDOWN PI -7 8 1 Ov TELEVISION ANTENNA OUTLET 0 STUB -UP OR DOWN OF COL CONTACTS SHOWN) u MOUNTED TO POLE LI6HT AT 32' CAST AULh4N ILM SUB BASE ROUND ALL I/2' AIR SPACE EXPOSED EDGES 6' FINS -ED GRADE • ' ANCHOR BOLTS 18' Ott 4 VERTICAL CONDUIT AS REQ'D 3tt 3 TES X ❑ 9 9" OF CENTER 9" ROUND 3 BOLLARD FIXTURE (i) E-2 M5 PI -6 14.4 PI -8 14.4 PI -10 14.4 PI -12 14.4 3OA-2P 30A -2P T- 0 NUMBER ID ON RELAY 8 SOCKET 1 2 IG O 3 5 6 - 7 2 I 4 Z 7 9 xi -D - I 161181 I 1 „ 31 i 2 b 3 5 6 1 SELECTOR SWITCH LABEL 'COUlRTtt2' H.O.A. J K L A 0 i H O N T PARK LIGHTS II PUSH BUTTON PILOT LIGHT (FLASHING) 3 # 14 TW NN/THWN-CU-1/2" MUSCO BI MUSCO 82 11 �- PUSH BUTTON PILOT LIGHT (FLASHING) 3 14 TNI-N/THWN-CU-1/2' GENERAL SELECTOR LIGHTING & MISC• LAMP SWITCH CU COPPER LABEL. 'coupTar EQUIPMENT IDENTIFIER 0 H.O.A. CONCRETE 2 VVRNG CONCEALED IN J K L EMERGENCY POWER ®LIGHTING A Q WALL ® DOWNLIGHT O CELNG OR WALL EMT ELEC. METALLIC TUBING L H i 2 b 3 5 6 1 SELECTOR SWITCH LABEL 'COUlRTtt2' H.O.A. J K L A 0 i H O N T PARK LIGHTS II PUSH BUTTON PILOT LIGHT (FLASHING) 3 # 14 TW NN/THWN-CU-1/2" MUSCO BI MUSCO 82 11 �- PUSH BUTTON PILOT LIGHT (FLASHING) 3 14 TNI-N/THWN-CU-1/2' ITIRR� DESIGN~GROUP L A N D S C A P E ARCH ITECTUR E SITE PLANNING -Ict:rc t,jvncc: Cf OCCUPANCY SWITCH CD T NOTE: TO MAINTAIN A COMFORTABLE NATURAL FEEL FOR RESIDENTIAL ENVIRONMENT, LAMP SUPPLIER MUST PROVIDE CORRECT LAMP COLOR < to TEMPERATURE PER SPECIFICATIONS. NO FIELD CHANGES SHALL BE MADE WITHOUT CORRECTION(S) SUBMITTED TO AND APPROVED BY THE BUILDING OFFICIAL. ORDER LIGHTING FIXTURES 5 WEEKS N ADVANCE BEFORE INSTALLATION. LDB, INC. WILL NOT RESPONSIBLE AND APPROVE FOR SUBSTITUTION OF LIGHTING FIXTURES. LIGHTING FIXTURE SCHEDULE GENERAL DESCRIPTION LIGHTING & MISC• LAMP WIRING CU COPPER O EQUIPMENT IDENTIFIER 0 CELING (A- SWITCH CIRCUIT) CONCRETE 2 VVRNG CONCEALED IN E EMERGENCY POWER ®LIGHTING FIXTURE DEN- Q WALL ® DOWNLIGHT LI6HTIN6 DISTRIBUTION, 24OV. CELNG OR WALL EMT ELEC. METALLIC TUBING TIFIE12 (X- FIXTURE TYPE Y- QUANTITY N GROUP) ® CHANDELIERS WIRING CONCEALED IN Eo VOLTAGE DROP EXIT FLR, OR UNDERGROUND TB TELEPHONE BACKBOARD eDETAIL Y REFERENCE (X- DETAIL v, Y- SHEET a) ® FLOURESCENT DOWNLC4T -- - - EXPOSED WRING WP WEATI-E12PROOF 40 DRAWING NOTE Q OUTSIDE WALL LIGHT PI -24 CIRCUIT IDENTIFICATION AL ALUMINUM WITH ALUMINUM BASE COVER (PANEL PI,CKTS 2 E 4) CO CONDUIT ONLY Q DRAWING REVISION �� BATHROOM WALL LIGHT 3tt2THW- WIRE E CONDUT LV LOW VOLTAGE 123 ROOM v IDENTIFIER LI6HTIN(5DISTRIBUTION, 240V. * COLOR SELECT BY OWNER CU -1.25' (3 CONDUCTORS COPPER AN ALL NIGHT WITH ALUMINUM BASE GOVER 0 FLOURESCENT LIGHT =2-AWG,THW INSULATION EO EARLY OFF KIM# G632-42PL24OV.-* RECEPTACLES �� FLOURESCENT LIGHT 1-1/4" CONDUIT) * COLOR SELECT BY OWNER PL-T42W/ SINGLE RECEPTACLE (+15") Q SMOKE DETECTOR S QUANTITY OF CONDUC- DIAGRAM SYMBOLS O3811. DUPLEX RECEPTACLE (+15") Q THERMOSTAT (+48") 0.30 TORS IN CONDUIT. (BOND WIRE EXCLUDED) PANEELBOARD(OR BREAKDOWN OF CIRCUIT BREAKERS SHOWN) 6.E. LAMP #F38/2D/827/4P/38VA RECEPTACLE, 208 OR 240V. 3 COMBINATION FAN O FAN/LIGHT --3 � STUB -OUT ® CONTROLLER(OR BREAKDOWN DUPLEX RECEPTACLE Ov TELEVISION ANTENNA OUTLET 0 STUB -UP OR DOWN 0.5-7 OF COL CONTACTS SHOWN) MOUNTED TO POLE LI6HT AT MOUNT# MH34-A MED ❑T TIME SWITCH YL 1 RED- E ELECTRICAL UTILITY GFI CSPLIT EPTACLE a'�'° CEILING FAN HADGO# W53-*-HF-N-1005-6-240V. PRIMARY FEEDER (T- TELEPHONE) O MOTOR QUAD C4) RECEPTACLE V TELEPHONE OUTLET - - BOUNDARY LINE WO UTILITY METER (WH-WATTHOUR,KVAR, ETC) ® FLOOR RECEPTACLE DISTRIBUTION ABBREVIATIONS LENS# MN32 NDICATOR OR PILOT LAMP ® CEILING RECEPTACLE 0 JUNCTION OR PULL BOX AFCI-CB ARC -FAULT CIRCUIT o 1 o UTTON ITCH NORMALLY OPEN INTERLIPT- CIRCUIT SWITCHES 0 TRANSFORMER BREAKER PUSHBUTTON SWITCH SINGLE POLE SWITCH NORMALLY CLOSED (+46', A- SWITCH LEG tt) DISCONNECT SWITCH FBO FURNISHED BY OTHERS CONTACTS NORMALCLOSED DOUBLE POLE SWITCH (DPST) (A: AMP RATING AND POLE) ELECTRICAL PL FMC FLEX. METAL CONDUIT I I CONTACTS NORMALLY OPEN THREE-WAY SWITCH (SPDT) SERVICE >~ IMC INTERMEDIATE METAL CONDUIT •�• COI- (REI -AY) JL SERVICE CENTER 4 FOUR-WAY SWITCH (DPDT) s PANEL OR LOADCENTER LFC LIQUID7r44T FLEXIBLE �• CIRCUIT BREAKER MOTOR SWITCH CONDUIT °\, DISCONNECT OR TOGGLE ALARMS NEC NATIONAL ELEC. CODE SWITCH (3P- 3POLES) DIMMER SWITCH E] MANUAL PULL STATION NL NIGHTUGHT LNSWITCHED) SPRING WOUND TIME SW lJ✓UJ BQ BELL (CHINE) RMC RIGID METAL CONDUIT (YYY•) TRANSFORMER KEY OPERATED SWITCH HEAT DETECTOR 12NMC RIGID NONMETALLIC II- UFER GROUND PLOT LIGHTED SWITCH FLOW SWITCH CONDUIT O PUSHBUTTON SWITCH NMC NONMETALLIC CABLE HAND -OFF -AUTO SWITCH D SENSOR SWITCH ° ITIRR� DESIGN~GROUP L A N D S C A P E ARCH ITECTUR E SITE PLANNING -Ict:rc t,jvncc: Cf OCCUPANCY SWITCH CD T NOTE: TO MAINTAIN A COMFORTABLE NATURAL FEEL FOR RESIDENTIAL ENVIRONMENT, LAMP SUPPLIER MUST PROVIDE CORRECT LAMP COLOR < to TEMPERATURE PER SPECIFICATIONS. NO FIELD CHANGES SHALL BE MADE WITHOUT CORRECTION(S) SUBMITTED TO AND APPROVED BY THE BUILDING OFFICIAL. ORDER LIGHTING FIXTURES 5 WEEKS N ADVANCE BEFORE INSTALLATION. LDB, INC. WILL NOT RESPONSIBLE AND APPROVE FOR SUBSTITUTION OF LIGHTING FIXTURES. LIGHTING FIXTURE SCHEDULE SYM DESCRIPTION MFG. & PART # LAMP 1AMPS1 MOUNTING SA 15011. H.P.S. 20FT. POLE LIGHT HADGO*k PA3-5-S-*-2-15OS-6-V-24OV (1)LU150/D 0.83 CONCRETE 2 CHECKED BY: ALUMINUM BASE COVER, TYPE II POLE# P2G5-20FT. MED BASE E_2 3 %s 2 LI6HTIN6 DISTRIBUTION, 24OV. * COLOR SELEGT BY OWNER WITH ALUMINUM BASE COVER 5A1 15011. H.P.S. 20FT. POLE LI6HT HADGO# PA3-5-5-*-3-1505-6-V-24OV. (I)LU150/1? 0.83 CONGRETE 2 ALUMINUM BASE COVER, TYPE III POLE# P2G5-20FT. MED BA5E E-2 LI6HTIN6 DISTRIBUTION, 24OV. * COLOR SELECT BY OWNER WITH ALUMINUM BASE COVER SA 15011. H.P.S. 20FT. POLE LI6HT HADGO# PA3-5-5-*-4-1505-6-V-24OV. (1)LU150/D 0.83 CONCRETE ALUMINUM BASE COVER, TYPE IV POLE# P2G5-2OFT. MED BASE 2 LI6HTIN(5DISTRIBUTION, 240V. * COLOR SELECT BY OWNER E-2 WITH ALUMINUM BASE GOVER SB 4211. FLUORESCENT BOLLARD, 24OV. KIM# G632-42PL24OV.-* PHILLIPS # 0.22 CONCRETE 3 *" COLOR SELECT BY OWNER * COLOR SELECT BY OWNER PL-T42W/ BASE 30/4P/42VA E-2 O3811. FLUORESGENT POLYGARBONATE RUPP# 550238 -UL -J -240V. INCLUDED 0.30 SURFACE TRANSLUCENT LENS, SURFACE 6.E. LAMP #F38/2D/827/4P/38VA 38VA. MOUNT, .240V. TEL : ( 800) -236--1000 SD 10011. H.P".S. FLOOD LI6HT HADGO# WB3-*-HF-N-1005-6-24OV. (I)LUIOO/D 0.5-7 CANOPY MOUNTED TO POLE LI6HT AT MOUNT# MH34-A MED +15FT. AFF, WITH CANOPY LENS# MN32 MOUNTIN6 AND VANDAL LENS, 24OV. 5D1 10011. H.P.S. FLOOD LI6HT HADGO# W53-*-HF-N-1005-6-240V. (I)LU100/D 0.57 CONCRETE MOUNTED ON 15FT. POLE WITH POLE# PTI`15-I5-A MED BASE VANDAL LENS, 240V. ARM# PT22A LENS# MN32 I 30A -2P I PI -14 14.4 I MUSCO B3 PI -16 14.4 - 3OA-2P PI -18 14.4 iT� MUSCO I B 4 PI -20 14.4 6OA-2P Eo I.7% PI -21 30 00 ;- " k'i < ;• VERIFY LOCATION AND ACTUAL AI°. L LOAD WITH ARCHITECTUAL PLANS PI -23 30 ; 3tt VO TNHN/THIN-CU L1 n6 CU-GND-2" (=31OFT) NOTE: L SERIES CONNECTED 12ATNG OF BREAKERS MAY BE USED. ALL OF BREAKERS MUST BE SAME MANUFACTURER AND UL LISTED. SERIES CONNECTED SHORT CIRCUIT C�RENT RATING FOR THAT VOLTAGE. 2. FIELD MARKED ON ALL EOUIPMENT. SHALL READ 'CAUTION SERIES RATED SYSTEM 42.000A AVAILABLE IDENTIFIED REPLACEMENT COMPONENT REQUIRED. * 3. PLR TO ATTACH SINGLE LINE DIAGRAM AND TENNIS COURT CONTROL SETTINGS TO INSIDE OF CUSTOMER SECTION OF THE SERVICE PEDESTAL. SINGLE LINE DIAGRAM NITS OI PHOTO CELL 120V. NTERMATIC ttK4021C-12OV. MOUNT N © CONTROL MODULE SQUARE-Dtt8903-FORM R6 -PI CONTROL CABINET. PROVIDE GLASS EYE ON NEMA -3R ENCLOSURE TO ALLOW LIGHT INTO CONTROL CABINET 7O SELECTOR SWITCH TEST - AUTO. 20A -P t�2 TIME SWITCH 12OV. MOTOR - SPST ® OFF DELAY TIMER. SOUARE-Du JCK29-V20 12OV. COL INTERMATIC ttETI00C SPST-120V. TIMER RANGE 1.2 MIN. TO 120 MIN. (TIMER SET AT 60 MIN.) O LIGHTING CONTACTORS 20AMPS. RATED 120V. COL O ON DELAY TIMER. SQUARE -Du JCK19-V20 12OV. COIL SQUARE -D u8903-LG40 TIMER RANGE 1.2 MIN. TO 120 MIN. (TIMER SET AT 50 MIN) ® SELECTOR SWITCH HAND - OFF - AUTO. SQUARE -Da 900KYO LIGHTING CONTACTOR 20 AMPS RATED 120V. COIL 2PDT SOUARE-Dtt KPI2-V20 O 4 POLE MECHANNCCALY HELD CONTACTOR, 30AMP RATED 120 VOLTS COIL, SQUARE -D #8903-SMG12-12OV. Il CONTROL MODULE SQUARE-Dtt 9001-KY2 PUSH BUTTONtt 9001 -KRB E 9001-KAI AND PLOT LIGHT# 9001-KPF 1231 24.75 26 i HINGED TOP METER UTILITY AND SECTIO TEST n 1g• SECTK n l I \ I u W 48 � PUP p� 0 I� FRONT 27.5 ( U I CUSTOMER jlll� SECTION I UTLIT•Y PULL u I SECTION • FINISHED GRADE m v • • ;�'• r CONDUIT AS ELEC. SERVICE PEDESTAL NTS ELEVATION BES CONCRETE PRODUCTS =C9E m J z Jam J 10 LL CLCD w 1` CE r - 6t! w Q w W • Z ��4)o co EL c �3 CC ° a� a� t 0 0 E c 0 a 3 Qs a � C a :v c W SLOPE CONCRETE c AWAY FROM EQUIPMENT 3 v_ Wz c c WITH CD9 (SOLID CONCRETE LID WITH LIFT HOLE) MARKING ON COVER IS 'ELECTRIC" (10 5/8" X 17 1/4" X 12" HIGH) TEL: (888) 783-5055 J-1 BOLTS (TYPICAL) r. FNISHED GRADE CONDUIT AS REQUIRED, SHOWN ON PLANS FOR FUTURE PHASE AT PHASE LINE. (2) 2' C.O. -� STUB -OUT 6' GRAVEL FOR DRANAGE FROM PEDESTAL PULL BOX DETAIL NTS E-2 LDB# 24023 LIGHTING DESIGNERS ELECTRICAL ENGINEERS 3051 EDINGER AVE. TUSTIN, CA 92780-7204 TEL: (949) 733-8038 INCORPORATED FAX: (949) 733-8058 XCITY OF FONTANA, CALIFORNIA DRAWN BY- SCALE: ORE H S PARK TRAC # 164 -2, LOT 106 NONE DESIGNED BY. DATE. 9/7/04 CHECKED BY: APPROVED BY: DWG NO.' 1 O CIT*ZWGINEER R . 51152 EXP DATE lV311M 3 %s 2 12 v z c z c ., z msco D CWF , c M, q'?A-o(o * 1LQ 91-L-1 z A c C c c t .Q A c c a c Ac c A / ` c i � Z LDB INC. U= ' J 917/04 17 0 1 I NONE 1 �SHEET�'�UM@ER � Eml 4 09-08-04