Loading...
HomeMy WebLinkAbout3702-4FINISH GRADE (LAWN) WATER SERVICE LINE (if applicable) 2X4 REDWOOD BLOCK CONTINUOUS AROUND GATE VALVE WATERPROOF ALL WIRE CONNECTIONS AS PER STD. RED BLACK VALVE BOX WHITE (COMI BLUE FLOW SENSOR DIAMETER SAME SIZE AS FLOW METER SIZE MINIMUM DISTANCE UPSTREAM 1OX DIAMETER OF FLOW METER SIZE GRADE ?D COVER) 7Pf tt LINE SIZE BRASS GATE VALVE PVC MALE ADAPTOR PVC IRRIGATION MAIN 1 CUBIC FOOT GRAVEL FILL OF 14 WIRES N.T.S. 19 MASTER CONTROL VALVE MINIMUM DISTANCE DOWNSTREAM 5X DIAMETER OF FLOW METER SIZE FLOW SENSOR/MASTER VALVE N.T.S. 110 1-W ZA;M au UNIUN 11* UK SERVICING ASSEMBLY REMOTE CONTROL VALVE 30—WH LINEAR LENGTH OF WIRE, COILED WATER PROOF CONNECTION (1 OF 2) ID TAG VALVE BOX WITH COVER: 12 X 18 FINISH GRADE/TOP OF MULCH REMOTE CONTROL. VALVE.- PVC ALVE:PVC SCH BD NIPPLE (CLOSE) PVC SCH 40 ELL PVC SCH e0 NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 4) SCH 80 NIPPLE 2—INCH LENGTH. HIDDEN) ANO SCH 40 ELL PVC MAINLINE PIPE PVC SCH 40 TEE OR ELL PVC SCH 40 MALE ADAPTER PVC LATERAL PIPE 3.0—INCH MINIMUM DEPTH OF 3/4—INCH WASHED GRAVEL CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD'S) 1. Toro Sentinel Model # SSAK48PS16NS1, 48 station field satellite controller. 2. Mount in Strong Box Model No. SB-24SS/12OV. (Stainless Steel) 3. Provide Rainmaster 32 PC 'Pigtail' for remote control) operation. 5. Provide Sensor Input Board (SIB) Model #995-63 to interface with flow meter and rain shut off device. 6. Provide Radio Link Kit #89-7611 to communicate with central command. All radio equipment shall be compatible with VHF. 7. Provide ground rod and surge protection for each satellite controller. Contact: Curtis Newman California Turf 619 520-6181 619 793-3999 Pager) 800 774-8873 Main Office) Park and Landscape Development Section. Engineering Division Community Development Department, City of Fontana (1/26/98) [..02,499 D= IJII1>m Cr SivaW WW eY CRY lMasum onwilaR me ❑ C0114111111111kcm NIIIE E1AE1frrIMBR 70 Xfr 11E 011111 1 OR N.T.S. 17 aQuaw 1g1Os; 36 ON mom 1IIHM mom= all onl�wroe. C 1l1eeI I lir 1111 o 1 WOOL L Pu SAL aollwlr Ileo. voMr CV= LOCM11101 /MID 1tIM1N1li1101t Ilea 1IRtt $X.L 00. swEEP CONDUIT FOR TIMOR TO 111eMclwle ELLS coNrROLLER WIRES CO1Ml1er Me M e11em ON NOIM11irm tc maw FRONT VIEW no 00111M ooleiIIJ11 oll1111 WM Inc ob##V11IM111' Nleuu m CLEAN BACK FILL SATURATE AND COMPACT TO 90% HARDSCAPING NATIVE BACKFILL 2" MINUS NON PRESSURE LATERAL UNE W/SLEEVE PRESSURE SUPPLY UNE W/SLEEVE CONTROL WIRE SLEEVE SAND BACK FILL L�L,LLd� •••, INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY UNE, SIZE PER SPEC. ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE LINE TO BE SLEEVED. * INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. SLEEVES SWILL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY INSPECTOR IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND PROVIDE A VERTICIL MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL SLEEVING PRESSURE REGULATOR SET AS SHOWN ON SITE DRAWING STRAINER 40 — MESH MO EL BRASS ELBOW VAR VE BALL BRASS PIPE i7ft!: PRESSURECONC. $UTPPPXLE) LINE TRUST ;6R_ RELIEF PORT LOOSE KEY ■ HOSE BIB 18 r FRONT N.T.S. 14 REDUCE PRESSURE BACKFLOW PREVENTER 'rASS NIPPLE 4 PLACES) -BRASS ELBOW -BRASS UNION BRASS PIPE BRASS BALL VALVE .LOCK BOX `#4 REBAR FOOTING/FOUNDATION EOEENCLOSURE BLL) RESENTBELOW) BRASS ELBOW BRASS UNION VALVES BALL } v Y /4 REBAR NOTE: BACKFLOW ENCLOSURE.LE MEUR OR EQUAL 24"X60'X36" HIGH E N D HINGED AT ONE END SECURE TO GRADE/TOP OF MULCH -COUPLING VALVE: N BIRD MODEL 33DRC BOX WITH COVER: NCH SIZE NIPPLE NGTH AS REQUIRED) H MINIMUM DEPTH OF �—INCH WASHED GRAVEL STREET ELL (1 OF 2) NIPPLE VGTH AS REQUIRED) STREET ELL SCH 40 TEE OR ELL VJNUNE PIPE ELL ,. 2- REDWOOD STAKE W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT NOTE: SUPPORT SYSTEM 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. QUICK -COUPLING VALVE N.T.S. 11 ANT MATERIAL DISH GRADE/TOP OF MULCH IP—UP SPRAY SPRINKLER: RAIN BIRD 1800 C SCH 80 NIPPLE (LENGTH AS REQUIRED) C SCH 40 ELL C SCH 40 STREET ELL C SCH 80 NIPPLE (LENGTH AS REQUIRED) C SCH 40 STREET ELL 6"X8" FOOTING W/4- J BOLTS EQUIPMENT HTO OUSING) BE CENTERED INSIDE HOUSINPVC SCH 40 TEE OR ELL GENERAL NOTES PVC LATERAL PIPE 1. CONTRACTOR SWILL FORM ENCLOSURE AND REQUEST INSPECTION PRIOR TO POURING FOOTING/FOUNDATION BACKFLOW PREVENTER N.T.S. 5 POP-UP SPRAY HEAD N.T.S. 2 GRADE 6" MIN FROM HARDSCAPES NON PRESSURE LATERAL LINE LATERAL LINE PRESSURE SUPPLY LINE CONTROLL WIRES LEAN BACKFILL R I C H A R D DC)Df Landscape Architecture Urban Design & Planning 181 N. 'E' Sheet. San Bernardino, CA 92401 phone: (909) 888-5568 fax (909) 384-9854 e-mail: rpa.la@vedzon.net Richard Pope, Landscape Architect CA# 2664 �,NDSC'4 Pe t9 ` tom^ \ i On OF CALF , Owner/Applicant: Stratham Homes, Inc. 2201 Dupont Drive, Suite 300 Irvine, CA 92112 (949) 833-1554 Atte: Mike Aller Nrs � REVISIONS: LA: C.2 ftswo 10 " 16 s~MIN FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES. NO 0IL o I z LO A IR MAM CONTROL BOARD METER FACES METER STREET LARGER THAN 1/2- INCH IN SIZE. THIS WILL BE PERMITTED IN THE INITIAL BACKFILL MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER OF TRENCH CAN BE FILL WITH ROCK SCREENED 2" MINUS. ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90% v � C E STRONG BOX MODEL NO. SB— 24SS/120V INSTALL ALL PVC PIPE WITH LABEL UP. SNAKE ALL PIPE IN TRENCH. •Clion O BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE SUPPLY UNE AND PROVIDE A SERVICE LOOP AT ALL 90 DEGREE CITY OF FO NTANA CALIFORNIA Ci » 6 CHANGES IN DIRECTION. / 0 i PRESSURE MAIN 2" AND LARGER SWILL BE P.V.C. CLASS 315 C C 0__y Drown By: LKD C.F.D. LANDSCAPE IMPROVEMENT PLANS for �T 1\ O. 16271 ll Scale: SWEEP CONDUIT FOR ELLS CONTROLLER WIRES END VIEW V415 SMALLER THAN 2" SWILL BE P.V.C. SCHEDULE 40. CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. CONTRACTOR SHALL PROVIDE 24" INCHES OF COVER OVER PIPE SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE 3" AND LARGER. Designed _ ,P, Date: 9/8/2004 AP Z Dwg. No. 3702 4 7 ACOW ENGINE E ICARDO SANDOVAL UC. 51152 "E)M:12/31/011 NOT USED N.T.S. 11 AUTOMATIC CONTROLLER N.T.S. 8 TRENCHING N.T.S. 16 1 NOT USED I N.T.S. 13 R I C H A R D DC)Df Landscape Architecture Urban Design & Planning 181 N. 'E' Sheet. San Bernardino, CA 92401 phone: (909) 888-5568 fax (909) 384-9854 e-mail: rpa.la@vedzon.net Richard Pope, Landscape Architect CA# 2664 �,NDSC'4 Pe t9 ` tom^ \ i On OF CALF , Owner/Applicant: Stratham Homes, Inc. 2201 Dupont Drive, Suite 300 Irvine, CA 92112 (949) 833-1554 Atte: Mike Aller Sheet De5crlption: Irrigation Details Date: September 8, 2004 RP*A Job No.: 04-33 Drawn by: LO JRO PCV15ion5: Sheet: L=4 O T r" LA: C.2 ftswo C 0IL A v � C E cc ~ Q, �_ •Clion O O L CL Ci aw C 0 i r E C C 0__y C3 U. J Sheet De5crlption: Irrigation Details Date: September 8, 2004 RP*A Job No.: 04-33 Drawn by: LO JRO PCV15ion5: Sheet: L=4