HomeMy WebLinkAbout3691-1GENERAL SEWER NOTES:
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA
STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION ('GREEN BOOK'). ALL REFERENCE
SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT
CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE GREEN
BOOK" THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY
ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVE—
LOPMENT DEPARTMENT ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION
COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF
ANY WORK IN PUBLIC RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST
NON—METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK
FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION
OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS
PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE
OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
THE POTENTIAL EXISTS FOR GROUND MOVEMENT
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT—OF—WAY WITHOUT
OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO.
THE COA TRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600
TWO WORKING DAYS BEFORE EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL
STAKING DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT
TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED
CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE
DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR
SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL
TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION
AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS
TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT—OF—WAY
DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21 A GEOTECHNIC4L ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE
TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE—WORKING OF THAT PORTION
OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE
TEMPORARY NON—ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH
TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE
A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE
DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE
VITRIFIED CLAY PIPE (V. C. P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS
OF THE ASTM DESIGNATION C700 FOR VC.P..
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL
OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE
WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND
VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS
TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS
SHOWN ON THE PLANS.
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2Z MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12"
BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE
STREET RIGHT—OF—WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS
MEASURED FROM THE UTILITY EASEMENT
31 THE SEWER CONTRACTOR SHALL STAMP AN 'S" IN THE FACE OF THE CURB AT THE
LOCATION OF THE SEWER LATERAL.
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED
IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED
AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLEC, TESTED AND APPROVED PRIOR
TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED
TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING,
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION
OF THE CITY TRAFFIC ENGINEER.
38 AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
APN 226-092-60
CITY OF FONTANA
SUMMIT AVENUE
SEWER IMPROVEMENT PLAN
PA 6A/ PARK
FONTANA UNIFIED SCHOOL DISTRICT
L YTL E CREEK RD. KNOX AVE.
/M PRO VEMENT PLAN REFERENCES
EXISTING SEWER IMPROVEMENT PLANS PER DWG NO. 3390 AND 2773
FUTURE SEWER IMPROVEMENT PLANS PER DWG NO. 3220
PROPOSED STREET IMPROVEMENT PLANS PER DWG NO. 3211
EXISTING STREET IMPROVEMENT PLANS PER DWG NO. 3389 AND 2682
FUTURE STREET IMPROVEMENT PLANS PER DWG NO. 3219
PROPOSED STORM DRAIN IMPROVEMENT PLANS PER DWG NO. 3213
FUTURE STORM DRAIN IMPROVEMENT PLANS PER DWG NO. 3221
PROPOSED TRAFFIC SIGNAL AND INTERCONNECT IMPROVEMENT PLANS PER DWG NO. 3394
PRIVATE ENGINEER'S NOT/CE TO CON TRA C TORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS: TO THE BEST OF OUR
KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY
LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND
RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON
THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE
JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,- INCLUDING
SAFETY OF ALL PERSONS AND PROPERTY,- THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY,
AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR
ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL
DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DISCREPANCIES.
BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
UNDERGROUND UTILITIES & STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS. "
CA U TION:
"THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR,
UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST
BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. "
NOTICE TO CONTRACTOR:
UTILITIES SHOWN HEREON AS "PROPOSED" MAY IN FACT BE EXISTING AT THE TIME
OF THIS CONSTRUCTION. THE CONTRACTOR SHALL DETERMINE IF ANY "FUTURE OR
PROPOSED" UTILITY HAS BEEN CONSTRUCTED.
TD Alf) 1 RR77
TD A//1 1 RRRO
SUMMIT AVENUE
TR. NO. 16427-5 TR. NO. 16427-5
PARKSIDE WA Y
INDEX MAP
SCALE: 1 "=250'
rn 11^ 4 7A / I
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: ANTHONY SALAM
ATTN: NORMA GUILLOT
8353 SIERRA AVENUE
1265 N. VAN BUREN STREET
FONTANA, CA 92335
SUITE 180
(909) 350-6632
ANAHEIM, CA 92807
18+50.00
(714) 666-5401
SO. CALIFORNIA GAS COMPANY
COMCAST (CABLE TV)
ATTN: GREG GASPAR
ATTN: JACK HAYES 1205
16231 VALLEY BLVD.
DUPONT AVENUE ONTARIO, CA. 91761
FONTANA, CA. 92335
(909) 390-4738
(909) 428-8411
SEWER LINE "A" FROM STA.
EMERGENCIES.- (800) 427-2200
TO 45+10.00
AND LATERAL "C". "D" AND
VERIZON
SO. CALIFORNIA EDISON COMPANY
ATTN: STEVE HOCK
7951 REDWOOD AVE.
1400 E. PHILLIPS BLVD.
FONTANA, CA. 92335
POMONA, CA. 91766
(909) 820-5598 — UNDERGROUND
(909) 469-6327
(909) 875-5100 — TRANSMISSIONS
7 3)
NA WA
(2 J57— 6233 — DISTRIBUTION
909
AT TNA MICHAEL C McGRA W
8440 NUEVO AVENUE
FONTANA, CA 92335 (909)
CRAWFORD CANYON MUTUAL WATER CO.
822-2201 FAX (909)
ATTN. BASIL J. FABRIZIO
823-5046
(909) 463-9580
WEST SAN BERNARDINO WATER CO.
UNDERGROUND SERVICE ALERT
ATTN: LON TSAI
(800) 422-4133
855 W. BASELINE ROAD
RIALTO, CA 92377
INDEX OF SHEETS
SHEET 1
SHEET 2
SHEET 3
SHEET 4
SHEET 5
SHEET 6
TITLE SHEET
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
SEWER LINE "A" FROM STA.
10+00.00
TO 18+50.00
AND LATERAL "E" AND "F"
3/4"
100
SEWER LINE "A" FROM STA.
18+50.00
TO 28+50.00
AND LATERAL 'B"
NO. 4
0-15
SEWER LINE "A" FROM STA.
28+50.00
TO 39+50.00
AND LATERAL "G"
PL
PROPERTY LINE
SEWER LINE "A" FROM STA.
39+50.00
TO 45+10.00
AND LATERAL "C". "D" AND
"H"
STREET STATION
DETAIL SHEET
NO TE'
LOCATIONS OF LINES AND LATERALS AND STREET CONNECTIONS HAVE NOT
BEEN APPROVED. LOCAL STORM DRAIN LINE AND LATERAL CONNECTIONS
MAY CHANGE UPON CITY/FIRE REVIEW OF TENTATIVES ONCE THEY ARE
FORMALLY SUBMITTED FOR CITY REVIEW.
RECORD DRA i c ,.
THM i AMM DRAWOM HAVE BEEN PP EPAREO, N
PHE±'i', ONTME I A816OF INFORMATION MAr- L9-0 AND
FURNISHM BY OTHERS. THE ENGINEER WALL K^7 BE
AL"MIAE FOR Aw ERRORS OR omIss!04S M*CH
HAVE Bmf INCORPORY M INTOTHE DOCUMINTS AS
A RESd,9i.TTHER OF.
NO -36637 `J z
p r_y
RIA044-,
V%0°G
rn un 4--0-7e)
CITRUS A VE.
TABLE: 200-1.2 A
SIEVE SIZE
PERCENTAGE
PASSING SIEVES
1 1 2"
—
1"
—
3/4"
100
1 2"
90-100
J18"
20-60
NO. 4
0-15
NO. 8
0-5
ASTM C 131
TEST GRADING
B
O
W
v
s,
Q
' U
(n
O
„
O
z
VIC/N/ T Y MAP
NOT TO SCALE
6" MIN.
10" MAX.
TOP OF STRUCTURAL
PA YEMEN T SUBGRADE
3" MAX. SIZE
NA TI VE SOIL
COMPA C TED 95%
6" MAX. SIZE —
NA Tl VE SOL
COMPA C TED 909
V. C.P.
10' OR DEEPER USE 1/2" —
CRUSHED STONE BEDDING
PER S TD. SPECS. FOR
PUBLIC WORKS CONSTRUCTION
TABLE 200 1.2 [A]
CONSTRUCTION NOTES
I O INSTALL 8- D.I.P. CLASS 350.
2O INSTALL 10" EXTRA STRENGTH VCP SEWER.
O CONSTRUCT PRECAST CONCRETE MANHOLE PER
CITY STD. NO. 112 (0=48').
O INSTALL 8" VCP PLUG.
O CONSTRUCT PRECAST CONCRETE MANHOLE PER
CITY STD. NO. 112 (0=60').
O INSTALL 10" VCP PLUG.
O7 INSTALL 8" EXTRA STRENGTH VCP SEWER.
-- j ►
VARIES 6" MIN.
I I 10" MAX.
N + I I 7: 1 SL OPE OR FL A TTER
OR ADEQUATE SHORING
1 " MAX. SIZE
SEL EC TED NA TI VE
BEDDING COMPACTED
TO 90%
u
TYPICAL BEDDING DETAIL
QUANTITIES:
— 175 L. F.
— 3317 L.F.
8 EA.
6 EA.
5 EA.
2 EA.
44 L.F.
LEGEND
CL
CENTERLINE
IRR
IRRIGATION
EX
EXISTING
TS
TRAFFIC SIGNAL
MH
MANHOLE
G
GAS LINE
INT
INTERSECTION
SD
STORM DRAIN LINE
PL
PROPERTY LINE
W
WATER LINE
R/W
RIGHT OF WAY
ST
STREET STATION
PROP
PROPOSED
Tl
TRAFFIC INTERCONNECT
10+00.00
SEWER STA TION