Loading...
HomeMy WebLinkAbout3691-1GENERAL SEWER NOTES: 1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ('GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE GREEN BOOK" THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVE— LOPMENT DEPARTMENT ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON—METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT—OF—WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE COA TRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT—OF—WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21 A GEOTECHNIC4L ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE—WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON—ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V. C. P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR VC.P.. 26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2Z MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT—OF—WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT 31 THE SEWER CONTRACTOR SHALL STAMP AN 'S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLEC, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT 36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING 37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38 AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. APN 226-092-60 CITY OF FONTANA SUMMIT AVENUE SEWER IMPROVEMENT PLAN PA 6A/ PARK FONTANA UNIFIED SCHOOL DISTRICT L YTL E CREEK RD. KNOX AVE. /M PRO VEMENT PLAN REFERENCES EXISTING SEWER IMPROVEMENT PLANS PER DWG NO. 3390 AND 2773 FUTURE SEWER IMPROVEMENT PLANS PER DWG NO. 3220 PROPOSED STREET IMPROVEMENT PLANS PER DWG NO. 3211 EXISTING STREET IMPROVEMENT PLANS PER DWG NO. 3389 AND 2682 FUTURE STREET IMPROVEMENT PLANS PER DWG NO. 3219 PROPOSED STORM DRAIN IMPROVEMENT PLANS PER DWG NO. 3213 FUTURE STORM DRAIN IMPROVEMENT PLANS PER DWG NO. 3221 PROPOSED TRAFFIC SIGNAL AND INTERCONNECT IMPROVEMENT PLANS PER DWG NO. 3394 PRIVATE ENGINEER'S NOT/CE TO CON TRA C TORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS: TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,- INCLUDING SAFETY OF ALL PERSONS AND PROPERTY,- THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS. CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS. UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. " CA U TION: "THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. " NOTICE TO CONTRACTOR: UTILITIES SHOWN HEREON AS "PROPOSED" MAY IN FACT BE EXISTING AT THE TIME OF THIS CONSTRUCTION. THE CONTRACTOR SHALL DETERMINE IF ANY "FUTURE OR PROPOSED" UTILITY HAS BEEN CONSTRUCTED. TD Alf) 1 RR77 TD A//1 1 RRRO SUMMIT AVENUE TR. NO. 16427-5 TR. NO. 16427-5 PARKSIDE WA Y INDEX MAP SCALE: 1 "=250' rn 11^ 4 7A / I CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA PACIFIC BELL CO. ATTN: ANTHONY SALAM ATTN: NORMA GUILLOT 8353 SIERRA AVENUE 1265 N. VAN BUREN STREET FONTANA, CA 92335 SUITE 180 (909) 350-6632 ANAHEIM, CA 92807 18+50.00 (714) 666-5401 SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV) ATTN: GREG GASPAR ATTN: JACK HAYES 1205 16231 VALLEY BLVD. DUPONT AVENUE ONTARIO, CA. 91761 FONTANA, CA. 92335 (909) 390-4738 (909) 428-8411 SEWER LINE "A" FROM STA. EMERGENCIES.- (800) 427-2200 TO 45+10.00 AND LATERAL "C". "D" AND VERIZON SO. CALIFORNIA EDISON COMPANY ATTN: STEVE HOCK 7951 REDWOOD AVE. 1400 E. PHILLIPS BLVD. FONTANA, CA. 92335 POMONA, CA. 91766 (909) 820-5598 — UNDERGROUND (909) 469-6327 (909) 875-5100 — TRANSMISSIONS 7 3) NA WA (2 J57— 6233 — DISTRIBUTION 909 AT TNA MICHAEL C McGRA W 8440 NUEVO AVENUE FONTANA, CA 92335 (909) CRAWFORD CANYON MUTUAL WATER CO. 822-2201 FAX (909) ATTN. BASIL J. FABRIZIO 823-5046 (909) 463-9580 WEST SAN BERNARDINO WATER CO. UNDERGROUND SERVICE ALERT ATTN: LON TSAI (800) 422-4133 855 W. BASELINE ROAD RIALTO, CA 92377 INDEX OF SHEETS SHEET 1 SHEET 2 SHEET 3 SHEET 4 SHEET 5 SHEET 6 TITLE SHEET SIEVE SIZE PERCENTAGE PASSING SIEVES SEWER LINE "A" FROM STA. 10+00.00 TO 18+50.00 AND LATERAL "E" AND "F" 3/4" 100 SEWER LINE "A" FROM STA. 18+50.00 TO 28+50.00 AND LATERAL 'B" NO. 4 0-15 SEWER LINE "A" FROM STA. 28+50.00 TO 39+50.00 AND LATERAL "G" PL PROPERTY LINE SEWER LINE "A" FROM STA. 39+50.00 TO 45+10.00 AND LATERAL "C". "D" AND "H" STREET STATION DETAIL SHEET NO TE' LOCATIONS OF LINES AND LATERALS AND STREET CONNECTIONS HAVE NOT BEEN APPROVED. LOCAL STORM DRAIN LINE AND LATERAL CONNECTIONS MAY CHANGE UPON CITY/FIRE REVIEW OF TENTATIVES ONCE THEY ARE FORMALLY SUBMITTED FOR CITY REVIEW. RECORD DRA i c ,. THM i AMM DRAWOM HAVE BEEN PP EPAREO, N PHE±'i', ONTME I A816OF INFORMATION MAr- L9-0 AND FURNISHM BY OTHERS. THE ENGINEER WALL K^7 BE AL"MIAE FOR Aw ERRORS OR omIss!04S M*CH HAVE Bmf INCORPORY M INTOTHE DOCUMINTS AS A RESd,9i.TTHER OF. NO -36637 `J z p r_y RIA044-, V%0°G rn un 4--0-7e) CITRUS A VE. TABLE: 200-1.2 A SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1 2" — 1" — 3/4" 100 1 2" 90-100 J18" 20-60 NO. 4 0-15 NO. 8 0-5 ASTM C 131 TEST GRADING B O W v s, Q ' U (n O „ O z VIC/N/ T Y MAP NOT TO SCALE 6" MIN. 10" MAX. TOP OF STRUCTURAL PA YEMEN T SUBGRADE 3" MAX. SIZE NA TI VE SOIL COMPA C TED 95% 6" MAX. SIZE — NA Tl VE SOL COMPA C TED 909 V. C.P. 10' OR DEEPER USE 1/2" — CRUSHED STONE BEDDING PER S TD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A] CONSTRUCTION NOTES I O INSTALL 8- D.I.P. CLASS 350. 2O INSTALL 10" EXTRA STRENGTH VCP SEWER. O CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY STD. NO. 112 (0=48'). O INSTALL 8" VCP PLUG. O CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY STD. NO. 112 (0=60'). O INSTALL 10" VCP PLUG. O7 INSTALL 8" EXTRA STRENGTH VCP SEWER. -- j ► VARIES 6" MIN. I I 10" MAX. N + I I 7: 1 SL OPE OR FL A TTER OR ADEQUATE SHORING 1 " MAX. SIZE SEL EC TED NA TI VE BEDDING COMPACTED TO 90% u TYPICAL BEDDING DETAIL QUANTITIES: — 175 L. F. — 3317 L.F. 8 EA. 6 EA. 5 EA. 2 EA. 44 L.F. LEGEND CL CENTERLINE IRR IRRIGATION EX EXISTING TS TRAFFIC SIGNAL MH MANHOLE G GAS LINE INT INTERSECTION SD STORM DRAIN LINE PL PROPERTY LINE W WATER LINE R/W RIGHT OF WAY ST STREET STATION PROP PROPOSED Tl TRAFFIC INTERCONNECT 10+00.00 SEWER STA TION