HomeMy WebLinkAbout3686-3NOTES: 1. WHERE THE BASIN IS TO BE CONSTRUCTED WITHIN THE LIMITS OF EXISTING OR PROPOSED SIDEWALK OR IS CONTIGUOUS TO SUCH SIDEWALK, THE TOP SLAB OF THE BASIN MAY BE POURED EITHER MONOLITHIC WITH THE SIDEWALK OR SEPARATELY, USING THE SAME CLASS OF CONCRETE AS IN THE BASIN. WHEN POURED MONOLITHICALLY. THE SIDEWALK SHALL BE PROVIDED WITH A WEAKENED PLANE ORA 25 mm(I') DEEP SAWCUT CONTINUOUSLY AROUND THE EXTERNAL PERIMETER OF THE CATCH BASIN WALLS. INCLUDING ACROSS THE FULL WIDTH OF THE SIDEWALK. SURFACE OF ALL EXPOSED CONCRETE SHALL CONFORM IN SLOPE, GRADE, COLOR, FINISH. AND SCORING TO EXISTING OR PROPOSED CURB AND WALK ADJACENT TO THE BASIN. 2. ALL CURVED CONCRETE SURFACES SHALL BE FORMED BY CURVED FORMS, AND SHALL NOT BE SHAPED BY PLASTERING. 3. FLOOR OF BASIN SHALL BE GIVEN A STEEL TROWEL FINISH AND SHALL HAVE A LONGITUDINAL AND LATERAL SLOPE OF 1. 12 MINIMUM AND I: 3 MAXIMUM, EXCEPT WHERE THE GUTTER GRADE EXCEEDS 8 PERCENT, IN WHICH CASE THE LONGITUDINAL SLOPE OF THE FLOOR SHALL BE THE SAME AS THE GUTTER GRADE. SLOPE FLOOR FROM ALL DIRECTIONS TO THE OUTLET. 4. DIMENSIONS: B = 970 mm(3'-2') V = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF THE CATCH BASIN AT THE OUTLET = 1.35 m(4.51. VU = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT AT THE UPSTREAM END OF THE BASIN, AND SHALL BE DETERMINED BY THE REQUIREMENTS OF NOTE 3. BUT SHALL NOT BE LESS THAN CURB FACE PLUS 300 mm(121. V I = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF THE INLET. NOTED ON THE PROJECT PLANS. H = NOTED ON THE PROJECT PLANS. W = NOTED ON THE PROJECT PLANS. A = THE ANGLE, IN DEGREES, INTERCEPTED BY THE CENTERLINE OF THE CONNECTOR PIPE AND THE CATCH BASIN WALL TO WHICH THE CONNECTOR PIPE IS ATTACHED. 5. PLACE CONNECTOR PIPES AS INDICATED ON THE PROJECT PLANS. UNLESS OTHERWISE SPECI- FIED, THE CONNECTOR PIPE SHALL BE LOCATED AT THE DOWNSTREAM END OF THE BASIN. WHERE THE CONNECTOR PIPE IS SHOWN AT A CORNER, THE CENTERLINE OF THE PIPE SHALL INTERSECT THE INSIDE CORNER OF THE BASIN. THE PIPE MAY BE CUT AND TRIMMED AT A SKEW NECESSARY TO. INSURE MINIMUM 80 mm(3') PIPE EMBEDMENT, ALL AROUND, WITHIN THE CATCH BASIN WALL, AND 75 mm(3') RADIUS OF ROUNDING OF STRUCTURE CONCRETE, ALL AROUND. ADJACENT TO PIPE ENDS. A MONOLITHIC CATCH BASIN CONNECTION SHALL BE USED TO JOIN THE CONNECTOR PIPE TO THE CATCH BASIN WHENEVER ANGLE 'A'S LESS THAN 70 DEGREES OR GREATER THAN 110 DEGREES, OR WHENEVER THE CONNECTOR PIPE IS LOCATED IN A CORNER. THE OPTIONAL USE OF A MONOLITHIC CATCH BASIN CONNECTION IN ANY CASE IS PERMITTED. MONOLITHIC CATCH BASIN CONNECTIONS MAY BE CONSTRUCTED TO AVOID CUT- TING STANDARD LENGTHS OF PIPE. 6. STEPS SHALL BE LOCATED AS SHOWN. IF THE CONNECTOR PIPE INTERFERES WITH THE STEPS, THEY SHALL BE LOCATED AT THE CENTERLINE OF THE DOWNSTREAM END WALL. STEPS SHALL BE SPACED 300 mm(12') APART. THE TOP STEP SHALL BE 175 mm(7') BELOW THE TOP TO THE MANHOLE AND PROJECT 65 mm(2-1/2'). ALL OTHER STEPS SHALL PROJECT 130 mrn(5'). 7. DOWELS ARE REQUIRED AT EACH CORNER AND AT 2 m(71 ON CENTER (MAXIMUM) ALONG THE BACKWALL. 8. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN: 308 MONOLITHIC CATCH BASIN CONNECTION 309 CATCH BASIN REINFORCEMENT 310 CATCH BASIN FACE PLATE ASSEMBLY AND PROTECTION BAR 312 CATCH BASIN MANHOLE FRAME AND COVER 635 STEEL STEP 636 POLYPROPYLENE PLASTIC STEP 9. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING BARS SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 300 - 2 SHEET 2 OF 2 CURB OPENING CATCH BASIN 11. THE FOLLOWING CRITERIA SHALL BE USED FOR THIS MANHOLE: A. MAIN LINE = 825 mm (33') INSIDE DIAMETER OR LESS. (EXCEPTION IF THE MAIN LINE RCP DOWNSTREAM OF THE MANHOLE IS 900 mm (36') TO 1050 mm (42') INSIDE DIAMETER AND THE MAIN LINE RCP UPSTREAM IS 825 mm (339 OR LESS.) STANDARD PLAN 320 OR STANDARD PLAN 322 IS NOT APPLICABLE WHERE THE MAIN LINE CONDUIT IS LESS THAN 900 mm (36') IN DIAMETER. B. SEE SECTION A - A. THE MAXIMUM SIZE LATERAL THAT MAY BE CONNECTED TO THIS MANHOLE IS SUCH THAT THE DISTANCE FROM THE OUTSIDE (TOP) OF THE LATERAL TO THE BOTTOM OF THE 200 mm (8") THICK TOP OF THE MANHOLE CHAMBER, MEASURED VERTICALLY FROM THE END OF THE RCP, SHALL BE A MINMUM OF 150 mm (6'). N C. IF THE SIZE OF THE LATERAL IS SUCH THAT THE ABOVE-SPECIFIED N MINIMUM DISTANCES CANNOT BE MAINTAINED, THEN ONE OF THE FOLLOWING ALTERNATE SOLUTIONS MUST BE USED. ° I. PROVIDE A SPECIAL STRUCTURE. O 2. PROVIDE TWO STANDARD STRUCTURES, CONSISTING OF THIS MANHOLE PLACED UPSTREAM OR DOWNSTREAM FROM THE APPLICABLE JUNCTION STRUCTURE OR TRANSITION STRUCTURE. 0 12. MANHOLE FRAME AND COVER SHALL CONFORM TO STANDARD PLAN 630 UNLESS OTHERWISE SHOWN. 13. MANHOLE SHAFT SHALL CONFORM TO STANDARD PLAN 324 UNLESS n OTHERWISE SHOWN. ri 14. WHERE A MANHOLE SHAFT - 900 mm (36") WITHOUT REDUCER IS SPECIFIED REFER TO STANDARD PLAN 336. a 0 15. WHERE A PRESSURE MANHOLE SHAFT - WITH ECCENTRIC REDUCER IS SPECIFIED REFER TO STANDARD PLAN 328. :v 16. WHERE A PRESSURE MANHOLE SHAFT - 914 mm (36') WITHOUT REDUCER iz IS SPECIFIED REFER TO STANDARD PLAN 329. 17. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES, EXCEPT REINFORCING n Lo IF ENGLISH UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. ENGLISH UNITS. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN: 324 MANHOLE SHAFT - WITH ECCENTRIC REDUCER z 326 MANHOLE SHAFT - 900 mm (360) WITHOUT REDUCER g 328 PRESSURE MANHOLE SHAFT - WITH ECCENTRIC 329 PRESSURE MANHOLE SHAFT - 914 mm (36') WITHOUT REDUCER z 630 610 mm (244) MANHOLE FRAME AND COVER 633 914 mm (36') MANHOLE FRAME AND COVER > 635 STEEL STEP 636 POLYPROPYLENE PLASTIC STEP i 0 / / J AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN MANHOLE PIPE TO PIPE (ONE OR BOTH MAIN LINE METRIC ID'S 825mm 3311OR SMALLER 321 - 1 SHEET 3 OF 3 z 1 Q REV :F DIG ALERT J DIAL TOLL FREE D 1-800-227-2600 z AT LEAST TWO DAYS BEFORE YOU DIG I Y UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA l z 0 v 0 J FACE PLATE SCORING LINE - 2 EXTRA 15M( 4) ON 2 SIDES OF MANHOLE FRAME AND COVER CATCH BASIN (I E MANHOLE FRAME AND COVER o 15M O 300 mm(#40121) FACE PLATE EACH WAY ASSEMBLY STREET GUTTER I co I 5 mm(I/4 )R STANDARD PLAN METRIC COMMITTEE 1984 OR LOCAL DEPRES- SION SURFACE 00 - ^ 300-2 2 REV. 1998 100 mm USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION REV 1996 SHEET 1 OF 3 [ 3' 2 w (4')R PLAN 324 PAVED STREETS, 0 SLOPE 900 mm (3'-0') 650 mm (2'-2') FLOW LINE �_ -75 mm It (3')R DOWEL E E E SCALE: --- (5') 125 mm x 50 mm (5'x2') PIPE SEAT (TYPA o X75 mm (3') T DESIGNED BY: JC --1 _ o CURB LINE c a - +> OF INLETS STEPS `- 25 mm (51 ROUND EDGES 9F \ a STEPS F EW in LN IU u _ m - z DOWEL (TYP.) U PLAN 0 i^ wa N o� _ oz o: JS a-, zF 0-0 0 H = 00 t 100 mm (4')MIN. 300 mm 75 mm 021MAX_ (3')R - % U. m X U OPTIONAL SUBGRADE CONNECTOR PIPE OR MONOLITHIC CATCH BASIN B CONNECTION SECTION A -A 200 mm(8') IOM(*4) 90° � j E: tiv DOWEL DETAIL AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE PUBLIC WORKS STANDARDS INC. GREENBOOK C U R B, -OPENING CATCH BASIN STANDARD PLAN METRIC COMMITTEE 1984 EXISTING STORM DRAINS 00 - ^ 300-2 2 REV. 1998 SHEET 1 OF 2 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CONC. PIPE UNDISTURBED EARTH -k MAIN LINE EXISTING RCP STORM DRAIN EXISTING RC BOX STORM DRAIN 1 P LAN CHIP PIPE TO SURFACE OF CONCRETE AND ROUND EDGES MORTAR �/N I PC. IPE SUPPORT PIPE ACROSS �„ TRENCH WITH 265 Kg -C-14 Mpa (450-C-2000) CONCRETE BACKFILL. SEE NOTE 3 MINIMUM BEARING SURFACE = OD/2 SECTION B - B CASE I PLAIN CONCRETE PIPE 100 mm U E z VARIES TO SUIT E CONDITIONS 0 0 v PLAN CASE 2 SECTION SADDLE CONNECTION SECTION C - C MIN. CLASS C MORTAR Ea E3 ^Q NN M ,-- 200 mm (8') MAX. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE PIPE CONNECTIONS TO STANDARD PLAN PUBLICREENRKSSTANDARDS MM117EINC., GREENBOOK COMMITTEE EXISTING STORM DRAINS METRIC 335-1 1964 ^ e F REV 1996 SHEET 1 OF 3 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION E B o ♦' - EDGES TO BE ROUNDED TO 75 mm (31 R i� At m I +A R = I D OF SPUR t 150 mm (6') MIN. )- ALL STEEL REINF. 15M O 100 mm (94 O 41) OC +C E- I' DETA i L "N" PLAN B (RINGS AND COVER NOT SHOWN) PLAN SEE NOTE I (SHAFT NOT SHOWN) STREET GRADE MANHOLE FRAME CONCRETE RINGS AND COVER PER PER STD. PLAN 324 STREET GRADE STD. PLAN 630 25 mm x 25 mm 610 mm OMIT THIS STEP (5'x1'1 w (24') IN PAVED STREETS RING SEAT I .. co -__ (24') MANHOLE CID MAIN LINE ID'S 825mm 33" OR SMALLER T 1050 mm (3'-61 SHAFT 225 mm (9 ^ e F USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION PER STD. 400 mm (16') FOR E w (1/2' PLAN 324 PAVED STREETS, 0 v' E 900 mm (3'-0') 650 mm (2'-2') 0 ^ STREETS FOR mm PAVED STREETS TRACT NO. 1 6317 SCALE: --- (5') 125 mm x 50 mm (5'x2') PIPE SEAT ^ X75 mm (3') T DESIGNED BY: JC DATE: 1 1 /29/04 o 1 50 mm (3'-6' ROUND EDGES - OF INLETS `- 25 mm (51 ROUND EDGES APPROVED Y: /R.C.E DWG N0. 3686 J I�col� Dp,AWIN�aS SfZI�p1 � •�. CITY ENGINEER 5� 52 15 mm N ET 2 610 mm -__ (24') 121 5nn(5' PUBLIC WORKS STANDARDS INC., GREENBOOK ITTEE MAIN LINE ID'S 825mm 33" OR SMALLER T 1050 mm (3'-61 T ^ e �9 175 mm (T) USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION E E x 15 mm N (1/2' (1/2' APPLIES AT THIS SECTION C -C POINT SECTION A -A STATION LINE 900 mm (3'-0') 200 mm (81 STEPS T 450 mm 08') 75 mm (3') x II L I 100 mm (4') 11 1 L+2T-200 mm (8') 100 mm (4') 200 mm (81 200 mm (8' OPTIONALBOTTOM GRADE POINTS, SEE NOTE 5 SECTION B -B TABLE OF VALUES FOR M (SEE NOTE 1) SECTION PAVED STREET UNPAVED STREET MAX. MIN. MAX. I MIN. A -A 1867 mm (2'-10 1/21 11060 mm (3'-61) C -C 282 mm 011 1217 mm (8 1/2') 410 mm 06') 1 380 mm (151) ww W J Nm a N W W J I - m 0 Q Z zw a W >N AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE MANHOLE PIPE TO PIPE (ONE OR BOTH STANDARD PLAN METRIC PUBLIC WORKS STANDARDS INC., GREENBOOK ITTEE MAIN LINE ID'S 825mm 33" OR SMALLER 321 - 1 1992 REV 1996 BENCH MARK: AT THE NEC FOOTHILL BLVD. AND EAST AVE., 43 FEET NORTH OF CL FOOTHILL BLVD. 60 FEET EAST OF EAST AVE., SET DRIVE PIN W/C.S. TAG IN APPROX. CENTER TOP OF EAST WINGWALL FOR BRIDGE #54-379 OVER ETIWANDA FLOOD CHANNEL. 4 ELEVATION: 1194.630 SHEET 1 OF 3 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 4L MAIN LINE EXISTING RCP STORM DRAIN I RCP -� CSP OR RCP- IN - UNDISTURBED EARTH SUPPORT PIPE ACROSS TRENCH WITH 265 Kq-C-14 MPo (450-C-2000) CONCRETE BACKFILL. SEE NOTE 3 PLAN I I EXISTING RC BOX STORM DRAIN r - F., r'41 I tw V4lwas E CLASS C MORTAR CSP OR RCP RCP `- CORRUGATED STEEL (CS BAND CONNECTOR BAND CONNECTOR NOT NEEDED FOR RCP) BURN OR CUT PIPE TO SURFACE OF CONCRETE AND ROUND EDGES OF RCP SECTION E - E OPTIONAL RECTANGULAR COLLAR DIA. OF C S P MIN. GAGE 375 mm (15') - 525 mm (21') 16 00 MINIMUM BEARING 600 mm (24') 14 SURFACE = OD/2 0 SECTION F - F CASE 3 RCP OR CSP D = 600 mm (241) MAX. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN METRIC 335 - 1 SHEET 2 OF 3 PIPE CONNECTIONS TO EXISTING335-1 STORM DRAINS NOTES I. WHEN DEPTH M FROM STREET GRADE TO THE TOP OF THE BOX IS LESS THAN 867 mm (2'-10 1/2') FOR PAVED STREETS OR 1060 mm (3'-6') FOR UNPAVED STREETS, CONSTRUCT SHAFT PER SECTION C -C AND DETAIL "N'. DEPTH M MAY BE REDUCED TO AN ABSOLUTE LIMIT OF 150 mm (6') WHEN LARGER VALUES OF M WOULD REDUCE H IN SECTION C -C TO 1060 mm (3'-6') OR LESS. 2. H (IN SECTION A -A AND B -B) SHALL NOT BE LESS THAN 1.2 m (4'-0'), BUT MAY BE INCREASED PROVIDED THAT THE VALUE OF M SHALL NOT BE LESS THAN THE MINIMUM SPECIFIED AND THAT THE REDUCER SHALL BE USED. FOR H (IN SECTION C -C) SEE NOTE I. 3. L SHALL BE 1.2 m (4'-0') UNLESS OTHERWISE SHOWN. L MAY BE IN- CREASED OR LOCATION OF MANHOLE SHIFTED TO MEET PIPE ENDS, BUT ANY CHANGE IN LOCATION OF THE SPUR MUST BE APPROVED BY THE ENGINEER. 4. T SHALL BE 200 mm (8') FOR VALUES OF H UP TO AND INCLUDING 2.4 m (8'-0") AND 250 mm (10') FOR VALUES OF H OVER 2.4 m (8'-0*). 5. STATIONS OF MANHOLES SHOWN ON PROJECT DRAWINGS APPLY AT CENTER LINE OF SHAFT. ELEVATIONS ARE SHOWN AT CENTER LINE OF SHAFT AND REFER TO THE PROLONGED INVERT GRADE LINES. SEE NOTE 3. 6. REINFORCEMENT SHALL CONFORM TO ASTM A 615M, GRADE 300(ASTM A 615, GRADE 40), AND SHALL TERMINATE 40 mm (1 1/2') CLEAR OF CONCRETE SUR- FACES UNLESS OTHERWISE SHOWN. 7. FLOOR OF MANHOLE SHALL BE STEEL TROWELED TO SPRING LINE. 8. BODY OF MANHOLE SHALL BE POURED IN ONE CONTINUOUS OPERATION EXCEPT THAT A CONSTRUCTION JOINT WITH A LONGITUDINAL KEYWAY MAY BE PLACED AT SPRING LINE. 9. THICKNESS OF THE DECK SHALL VARY WHEN NECESSARY TO PROVIDE A LEVEL SEAT BUT SHALL NOT BE LESS THAN 200 mm (8'). 10. STEPS SHALL CONFORM TO STANDARD PLAN 635 OR 636. UNLESS OTHERWISE SHOWN, STEPS SHALL BE UNIFORMLY SPACED 350 mm (14") TO 375 mm (15') OC. THE LOWEST STEP SHALL NOT BE MORE THAN 600 mm (24') ABOVE THE LEDGE AT THE SIDE OF THE MANHOLE. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 1 SHEET 2OF3 MANHOLE PIPE TO PIPE (ONE OR BOTH MAIN LINE321RIC ID'S 825mm 33 OR SMALLER) GENERAL NOTE I. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES, EXCEPT REINFORCING BARS SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. NOTES CASE I AND CASE 3 I. OUTSIDE DIAMETER OF THE CONNECTOR PIPE SHALL NOT BE GREATER THAN 1/2 THE INSIDE DIAMETER OF THE RCP MAIN LINE. 2. INSIDE DIAMETER D OF THE CONNECTOR PIPE SHALL NOT BE GREATER THAN 600 mm (24'). 3. THE MINIMUM OPENING INTO THE EXISTING STORM DRAIN SHALL BE THE OUTSIDE DIAMETER OF THE CONNECTING PIPE PLUS 30 mm (11. THE CONCRETE BACKFILL SUPPORTING THE CONNECTING PIPE MAY BE OMITTED IF THE PIPE IS LAID ON UNDISTURBED EARTH TO STORM DRAIN WALL. 4. ALL CSP AND FITTINGS SHALL BE GALVANIZED. BAND CONNECTORS MAY BE 2 GAGES LIGHTER THAN THE PIPE. BUT WITH A MINIMUM GAGE OF 16. THEY SHALL BE CONNECTED AT THE ENDS BY ANGLES HAVING MINIMUM DIMENSIONS OF 50 mm x 50 mm x 5 mm (2"x2'x3/16') AND 140 mm (5 1/2') BOLTS. 5. WHEN JOINING A RCP CONNECTOR PIPE TO A CSP CONNECTOR PIPE, THE INSIDE DIAMETER D OF THE CSP SHALL BE AT LEAST EQUAL TO BUT NOT MORE THAN 75 mm (3') GREATER THAN THAT OF THE RCP. 6. CONNECTOR PIPES SHALL BE NOT MORE THAN 1.5 m (51 ABOVE THE INVERT. 7. CONNECTOR PIPES SHALL ENTER MAIN LINE RCP RADIALLY. 8. WHEN CONNECTING TO A RCB, STANDARD PLAN 333 SHALL BE USED IF THE TOP OF THE CONNECTOR PIPE IS LESS THAN 300 mm 021 BELOW THE SOFFIT OF THE RCB OR THE FLOW LINE OF THE PIPE IS LESS THAN 330 mm (131 ABOVE THE FLOOR OF THE RCB AT THE INSIDE FACE. CASE 2 9. SADDLE CONNECTIONS SHALL BE USED WHEN CONNECTING TO PIPES 525mm (21') OR LESS IN DIAMETER WITHOUT THE USE OF JUNCTION STRUCTURES OR PRECAST Y BRANCHES. 10. TRIM OR CUT SADDLE TO FIT SNUGLY OVER THE OUTSIDE OF THE MAIN PIPE SO ITS AXIS WILL BE ON THE LINE AND GRADE OF THE CONNECTING PIPE. II. THE OPENING INTO THE PIPE SHALL BE CUT AND TRIMMED TO FIT THE SADDLE SO THAT NO PART WILL PROJECT WITHIN THE BORE OF THE SADDLE PIPE. 12. THE CONNECTOR PIPE SHALL BE SUPPORTED AS SHOWN IN CASE I AND CASE 3. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN PIPE CONNECTIONS TO EXISTINGMETRIC STORM DRAINS 335 - 1 SHEET 3 OF 3 REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONTSTRUCTION OF REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH INA DILIGENT MANNER THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO COMFORMANCE WITH CONDITIONS AND STANDARDS IN AFFECT ? PREPARED FOR: FIELDSTONE COMMUNITIES, INC. 2 ADA, SUITE 200 IRVINE, CA. 92618 (949) 790-5400 BENCH MARK: AT THE NEC FOOTHILL BLVD. AND EAST AVE., 43 FEET NORTH OF CL FOOTHILL BLVD. 60 FEET EAST OF EAST AVE., SET DRIVE PIN W/C.S. TAG IN APPROX. CENTER TOP OF EAST WINGWALL FOR BRIDGE #54-379 OVER ETIWANDA FLOOD CHANNEL. 4 ELEVATION: 1194.630 PREPARED BY: 10390 Commerce Center Dr., Ste. zoo Q�oFESs,otiq Rancho Cucamonga, California 91730 �o < �� ��e��� Fc Phone (909) 581-0678 No. 04,255 m FAX (909) 581-0696 W m Civil Engineers Land Surveyors ¢ Exp. 12/31/05 � Job Dumber: 855.0101 srq � P��"12, Soo- rE 0` �IYIFo C"� /I °A`STEVE L. ELLIS DATE CITY O F FO NTANA STORM ®RAIN IMPROVEMENT PLANS DRAWN BY: SC TRACT NO. 1 6317 SCALE: DESIGNED BY: JC DATE: 1 1 /29/04 - CHECKED BY: '��'� LJ APPROVED Y: /R.C.E DWG N0. 3686 OF 3 3 I�col� Dp,AWIN�aS SfZI�p1 � •�. CITY ENGINEER 5� 52