Loading...
HomeMy WebLinkAbout3658-10 t 24" NOTE: - C1:0_ `AN1ISI;gp�. ' —'r ALL POWER WIRES, GROUND WIRES ETC. O FINISHED GRADE 1nN $�' y. 0SHALL BE I 1 � 2 ► SEPARATELY SLEEVED AND SWEPT THROUGH 2 6" ROUND �'`' �I • 2 EXACT LOCATION OF CONTROLLER SHALL BE AGREED ENCLOSED PAD WITH SCH 40 RIGID CONDUIT — 0 O VALVE BOX UPON BY EDISON, CITY LANDSCAPE INSPECTOR AND ALL SLEEVING SHALL BE A MINIMUM OF 18" BELOW 3 TORO DL2000 AIR/VACUUM • it CONTRACTOR PRIOR TO ANY TRENCHING OR — — FINISHED GRADE. ALL SLEEVING IS A GRAPHIC REPRESENTATION 0 RELIEF VALVE (YD-500-34) 36" WIRE PLACEMENT E _ OF A TYP. INSTALLATION. 4 © - O 1/2" PVC COUPLING (TxT) ( > � IRRIG. -111111 ' CONT. _ O 1/2" SCH. 80 NIPPLE i't', ' _ SIZE OF EQUIPMENT = 46"W X 18"D X 54" HIGH O (LENGTH AS REQUIRED) AND O PEA GRAVEL SUMP (6") E SIZE OF CONC. SLAB = 52"W X 24"D X 8" THICK -- - I. —�- W/#4 REBARS AT 12" O.C. TYP 0 0 — 0 BRICK SUPPORTS i k s E ,4.• 0� ': .• • 8 PVC PIPING AND FITTING 1 2" GENERAL NOTES: - _ , ' e•..• * , , ,•• 1. 1,41•1141-04• l�4,��!+�!t f:A�� rit--:* . •• . 0/• 4 • 011-.1-411"4"-•4,4 ►t 167 :�o ak% m L PROVIDE 100A METER AND 50A/2P MAIN C/B WHERE INDICATED _0 , soo • I 4 o . ON DRAWINGS NOTES i' co II . ., ,�. : 8" DIA. X 12" D. ...,: z co , ' • '` PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS. u L BOTTOMLESS GROUND WELLI 11 1. AIR/VACUUM RELIEF VALVE 0 311, WITH PARKWAY COVER, LOWER THAN DRIPLII CANNOT BE NE CONNECTED t ' U PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED FILL WITH PEA GRAVEL MI LATERALS. Q Q 90 ON DRAWINGS. _ I 2. USE ONE FOR EACH geV 0 Z SWEEP CONDUIT FOR ` . a d i" I I I I I I INCREMENT OF 7 GPM. ELLS TERMINATE AT EXISTION HANDHOLE. PER S.C.E. COMPANY RE I, a • a2 a 'a' • °a a0 oW CONTROLLER Q• p WIRES VERIFY EXACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO. #4 REBARS 1 n- V PRIOR TO TRENCHING TYP. 0 5/8"DIA X 10' DRIVEN GROUND o M t� a ROD PER ARTICLE 250-81 E 0 ` °' FRONT VIEW CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALLEC CONDUIT SECTION/ELEVATION V �, AND COPPER CONDUCTORS WITH TYPE "THHN/THWN" INSULATION. OF 1990 NEC kb _ NTS Ci) ( o a. AIR RELIEF VALVES w w8 1 11 1611 PUMP CONCRETE ® 2 V w TEMPLATE EXTRA MOUNTING 0 U U � STRONG BOX SIGNAL SLAB t ' , _ � J E IRRIGATION CONTROL MODEL NO. SB- 24SS/1 20V POWER ,i4.1111. 141 X O J BOARD — - PROVIDE 20 AMP �+� ' -u 00 METER FACES 2 POLE BREAKER Mj ► OrEE: �-- U Q 4"-------- FOR NEW PUMPS O �r� � TORO-FT-050 u z Q _ STREET WHERE APPLICABLE ������� �-� W Z o � A 0 ®TOP OF MULCHMETERU U N 36" • 50 A1" CONDUIT FOR N CITY OF FONTANA obwairipw-- GROUND ROD3 PRESSURE-COMPENSATING "�2PINSTALLATION OIN-LINE EMITTER IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICT (CFD'S) 120/240 rr TUBING:TORO I 2 EXTRA 1 CONDUITS RPG-418 0 3W R SENTINEL MODEL* ESB48U-24SM-0S1-V 48STATION 12 CIR O TIE DOWN STAKE - �� 1. FIELDIESATELLITE CONTROLLER. PANEL CITY OF FONTANA 0 © © 0 I 2. MOUNT IN STRONG BOX MODEL NO. SB-24SS/120V - IRRIGATION CONTROLLER STANDARD r', 1 FINISH GRADE FOR COMMUNITY FACILITIES DISTRICTS �'J (STAINLESS STEEL). (CFD'S) 1 2" 3. PROVIDE GROUND ROD AND SURGE PROTECTION FORF 7 t. G n SATALLITE CONTROLLER. 1. Toro Network 8000 Model # 132-86-08, 32 station field ll ll satellite controller. :` Contract: Mike Dobis FINISHED GRADEfl 1 2. Mount in Strong Box Model No. SB-24SS/120V. I�IJf TO FLUSH VALVE o • �: + : II • • '•II•• �� :� Turf Star \1/4 (Stainless Steel) �. 4?•3 ` 3. Provide Ralnmaster 32 PC 'Pigtail' for remote control) ,`/ `� `� `� `� `� v `� v `/ `� `� '� 0.: (800) 774-8873 (main office) �; : II . ' ' . a. g \/\/\/\/\/\//\�/\�/\�/\�/\�/\�/\%�� operation. ` //\//i A /.\/%/i//i//i//%/\\/j� I Park and Landscape Development Section, -� • • ° / • 4 4. Provide Cambell Scientific Inc,TE525 tipping bucket90a • r� Hea Dut Model '� CI Engineering Division Community Development, ( vy y ) , D t SWEEP City of Fontana (6/26/04) 5. Provide Sensor Input Board (SIB) Model #995-63 toELLS CONDUIT FOR GROUND FOR ELECTRICAL / interface with flow meter and rain shut off device. c AIL' UCONTROLLER /�WIRES 6. Provide Radio Link Kit #89-7611 to communicate with ICincentral command. All radio equipment shall be , -a-iEND VIEW 3/4 C, 1#6 compatible with VHF. ai) ,7. Provide ground rod and surge protection for each n,NTS satellite controller. ICD , . (f)Contact: Curtis Newman Z ;' STAR Turf 2 (619) 520-6181 7 (619) 793-3999 (Pager) His-18"-H (800) 774-8873 (Main Office) i 0 ELECTRIC METER & IRRIGATION CONTROLLER ENCLOSURE Park and Landsca a Development Section, EngineeringDivision1 p p �' ' ' `' 44 PRESSURE-COMPENSATING ■ Community Development Department, City of Fontana (1/26/98) O © IN-LINE EMITTER . = TUBING:TORO1 0 , ,, RPG-418 1 14 i 14 14 �� 4 ®EMITTER(PREiNSTALLED) F ® I IN TUBING € i '_ 1O FINISH GRADE �\ �18^� 1....1„..... 110111 ORM---) I (--- 2 7O ONE CUBIC FOOT 3/4" \� ____\ O PLANT MATERIAL Z IL O 1 ELECTRICAL CONDUIT CRUSHED ROCK \ �� -.. O ,'� 4 TORO-FT 050 7', a w 8 8 DIA. CL. 160 PVC SLEEVE w/ O Vtl 3 PLASTIC VALVE BOX, / O i 0 , O locking cover branded "GV" flared bottom contacting supply line // \ )11 > t 4 FLOW SENSOR. refer to plans and O BELDEN #9883 CABLE (sensor leads \\ ,� "___ PLAN VIEW ., ��� O specifications to data decoder. / © Z I ;....„4# 1� < , PVC MAIN LINE / © \ s '` io, - ..,... 1 ►��'- �' PVC MALE ADAPTOR (2 req.) I I ` ,' 1+ ,,.� � - i',,,.'1;. ;: U F ,‘l..._ TYP. CONCRETE TO REST ELEVATION 1 \� / I ‘5":41.Y641006,..,_ I. AGAINST UNDISTURBED 3 / rat • SOIL .:::::'.:::::::'.::::: . O O \ / v . . . . . . . A . t . t . \ C'7 Ea, , F , , . . ._ . . . . . 014.....W . . . . . . . . . . . . A / Q o f f f r t f f i f f f f , oo_ . . . . . . . . E . . . • v� �/ r F- Z J • r f r r z • r f I- all )14.1111) Pta 0 •;.../......'.,...`, 1111111111, a'� TYP. CONCRETEC) i: 0 H ' THRUST BLOCKS - � Z 1114.01NF CD4 k+4.144.4 r: C) 0 I nn .. goo iiiii Iiiiiiiiiiii 44 REBAP.DETAIL O + «« « -�I +;:;*: :$4 �t.M. +•x Cl) .«e + +' ++++° . h1.�iim+++++• LANDSCAPE DRIPLINE W/ EMITTERS NOTE:THRUST BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH PIPE C) :*+^'4%. * +*+ p I + ++t++y+*++ '* + Vi t; l JOB NUMBER MANUFACTURER'S RECOMMENDATION FOR SIZE OF PIP --•-ji wiiiil IL) miiiIIIIIL --•.-tNG REQUIRED. +=+a.•1 0 UTILIZED IN ALL (2 1/2^ AND LARGER MAINLINE PIPE #3 REBAR TO BE PLACED AROUND PIPE INTO THRUST BLOCK TYP. - 1 ,. CEN-305.01 t s V Ox.i. dia.min. x.i.: .ia.min. ` ll'r DATE upstream downstream 41) apAorlsri,,4, APPROVED BY: CITY OF FONTANA 0 0 O TORO DL2000 AUTOMATIC FLUSH t 12-08-03 ,e, .-....i, 7�= * Gu •e . `{z&At, NOTE: Install valve box so that top of cover is 2" above finish grade in �� VALVE (FCH-H) PLUMBED TO t' d wa t5,16 C1TYENGINEEt2 DATE: THRUST 55 LBLOCK ground cover areas and 1/2" in turf areas. 0• TUBING (TYP.) `, [ DRAWN ROBERT W.WEDDLE * O.12p1/Ot a. DRAWN BY: TIMOTHY RASTEDT. It • ' ' • O PVC FLUSH MANIFOLD I' CH N .44*or cot �! DATE OF LAST REVISION: STD,PLAN NC1 san I cur I r cl O TORO DL2000 MANIFOLD-TO- O I ELBOW CONNECTION (TYP.) 13 CHECKED J THRUST BLOCK ASSEMBLY0 FLOW SENSORO a I I I I 04 POINT OF CONNECTION RB F- 1 1 0 1 1 1 I O © O BACKFLOW PREVENTER , fl SHEET TITLE m 1 1 1 O REMOTE CONTROL VALVE t IRRIGATION n I I a I O WITH FILTER AND CO PRESSURE REGULATOR DETAILS & LEGEND I• r _ J O7 PVC SUPPLY MANIFOLD C SCALE V 1 1 "oI 0 80 TORO DL2000 MANIFOLD-TO- 1/8"=1'-0° j TEE CONNECTION I I I I OTORO DL2000 DRIPLINE LATERAL f El REVISIONS I 0 (RGP-418-10) 0 I I I I e AIR/VACUUM RELIEF LATERAL 1 etz-o{?..Q OQ1kw► O 1 1 1 O TORO DL2000 BLANK TUBING (A710) €', (INT) 03•Z•6-dR O CENTERED ON MOUND OR BERM 1FI�-A A'e M*0' I I I 11 TORO DL2000 AIR/VACUUM �\ 411� J • Q 1 I RELIEF VALVE (YD-500-34) I 1 I 1 PLUMBED TO TORO DL2000 A 1- BLANK TUBING (A710) AT e g 1r, • I -0?6 I• 0 EACH HIGH POINT n m �� 12 PERIMETER LATERALS € Cl) ® 2" TO 4" FROM EDGE A ›. 13 AREA PERIMETER /� F_ ® TORO DL2000 OPERATION L / U 14 G PLAN INDICATOR (DL-MP9) n I z N A .. 1 • CITY OF FONTANA ® CENTER-FEED DRIP LAYOUT �\ 9 I r . DRAWN BY: SCALE: COYOTE CANYON SHEET N IV DESIGNED BY: SREET S -3APE HASE 1 DATE: ; F= , / '7 I n CHECKED BY:- APPROV•• BY: DWG N0. L ®8 Cl) ,Ix,/ k ' 7�Y t �' #3658 CITY ENGINEER ' R.C.E. 51152 , - } U