HomeMy WebLinkAbout3655-10REDUCE PRESSURE BACKFLOW
PREVENTION
PRESSURE REGULATOR IF
REQUIRED. SET AS SHOWN
ON SITE DRAWING
STRAINER #40 MESH
MONEL
BACKFLOW ENCLOSURE
(SEE NOTE BELOW)
BRASS ELBOW
BRASS NIPPLE
BRASS BALL VALVE
BRASS PIPE
LOCKBOX
to
STAINLESS STEEL
"U" BOLT EMBEDDED
IN CONCRETE FOR `2
LOCKING FEATURE
NOTE: CONTRACTOR SHALL FORM ENCLOSURE BASE AND REQUEST INSPECTION PRIOR TO POURING.
CONTRACTOR SHALL USE 520-C-2500 CONCRETE.
IL
SCALE: N.T.S.
allwall
LEGEND:
1. POP-UP SPRAY HEAD, 3/4' ABOVE FINISH GRADE
IN LAWN AREAS AND 1 1/2" ABOVE FINISH GRADE
IN PLANTING AREAS.
2, WALK OR CURB,
3. PVC SCH. 80 NIPPLE - 4" MIN. LENGTH.
4, PVC TXT 90 DEG, ELL.
5. LATERAL LINE PIPE AND FITTING.
6. MARLEX 90 DEG, STREET ELL.
7, PVC SCH. 80 NIPPLE - 6" LONG.
& FINISH GRADE,
1 1/2" IN TURF AREAS.
3" IN PLANTING BEDS.
NOTE:
USE TEFLON TAPE OR TEFLON PIPE DOPE ON
ALL PVC TO PVC OR METAL TO PVC MALE PIPE
THREADS.
6" POP-UP SPRAY HEAD,
SCALE: N.T.S.
LEGEND:
1, 6' ROUND PLASTIC FULL BOX COVER BOLT DOWN TYPE.
2. FINISH GRADE LAWN AREAS.
3. FINISH GRADE SHRUB AREAS,
4, COMMUNICATION CABLE/CONTROL WIRE,
5, PEA GRAVEL. (MIN. 2' CU. FT.)
NOTE: REMOTE CONTROL BOX MAY BE USED IN LIEU OF SPLICE BOX.
SPLICE BOX ASSEMBLY
SCALE: N.T.S.
BRASS NIPPLE (4
DRAWN BY:
KPF
PLACES)
PROJECT: SYCAMORE HILLS
BRASS ELBOW
FOR MATERIAL 90% COMPACTION
BY: MPH
BRASS NIPPLE
REQUIRED\
/
BRASS UNION
SOURCE OF INFORMATION: PEGGY
A�
BRASS BALL VALVE
2. EXTEND ALL SLEEVES 12" BEYOND
SUPPLIER: WEST SAN BERNANDINO
BRASS PIPE
RELIEF
EDGE OF HARDSCAPING AT BOTH
POIN
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
HINGE (2 PLACES)
SE KE
PROVIDE 6" MIN. OF SAND
#4 REBAR CONTINUOUS LOOP
')E BIBB
3. ROUTE SLEEVING AROUND HANDICAP
BEDDING AND SHADDING
P.S.I. LOSS:
WATER METER SIZE:
2" @
44
GPM 1.50
PRESSURE REGULATOR:
2" @
PRESSURE SUPPLY LINE
GPM
(DISCHARGE)
2" @
44
GPM
FLOW SENSOR:
11/4" @
44
MALE ADAPTOR PVC SCH. 40
MASTER VALVE:
BRASS ELBOW (DO NOT ENCASE
GRAVEL
44
3/4" IN CONIC. STABILIZER
BRASS ELBOW
ADJACENT TO PRESSURE
CONS, STABILIZER
GPM
MAINLINE (CL. 315):
NOTE: BACKFLOW ENCLOSURE: LEMEUR GREEN CAGE
44
MODEL# BF -99 OR EQUAL I 8WX30LX30H:
AUTOMATIC VALVE SIZE:
HIGH & HINGED AT ONE END. SECURE
44
TO CONCRETE PAD -SIZE AS REQUIRED
LATERAL LINE SIZE:
W/4'"J'BOLTS. (EQUIPMENT TO BE
DDCQQf [Or- 011001 V I IhIr
CENTERED INSIDE HOUSING). WIRE
NOTE: CONTRACTOR SHALL FORM ENCLOSURE BASE AND REQUEST INSPECTION PRIOR TO POURING.
CONTRACTOR SHALL USE 520-C-2500 CONCRETE.
IL
SCALE: N.T.S.
allwall
LEGEND:
1. POP-UP SPRAY HEAD, 3/4' ABOVE FINISH GRADE
IN LAWN AREAS AND 1 1/2" ABOVE FINISH GRADE
IN PLANTING AREAS.
2, WALK OR CURB,
3. PVC SCH. 80 NIPPLE - 4" MIN. LENGTH.
4, PVC TXT 90 DEG, ELL.
5. LATERAL LINE PIPE AND FITTING.
6. MARLEX 90 DEG, STREET ELL.
7, PVC SCH. 80 NIPPLE - 6" LONG.
& FINISH GRADE,
1 1/2" IN TURF AREAS.
3" IN PLANTING BEDS.
NOTE:
USE TEFLON TAPE OR TEFLON PIPE DOPE ON
ALL PVC TO PVC OR METAL TO PVC MALE PIPE
THREADS.
6" POP-UP SPRAY HEAD,
SCALE: N.T.S.
LEGEND:
1, 6' ROUND PLASTIC FULL BOX COVER BOLT DOWN TYPE.
2. FINISH GRADE LAWN AREAS.
3. FINISH GRADE SHRUB AREAS,
4, COMMUNICATION CABLE/CONTROL WIRE,
5, PEA GRAVEL. (MIN. 2' CU. FT.)
NOTE: REMOTE CONTROL BOX MAY BE USED IN LIEU OF SPLICE BOX.
SPLICE BOX ASSEMBLY
SCALE: N.T.S.
LEGEND:
DRAWN BY:
KPF
CLEAN BACKFILL - SEE SPECS
PROJECT: SYCAMORE HILLS
SLEEVING NOTES:
FOR MATERIAL 90% COMPACTION
BY: MPH
STATIC PRESSURE HIGH: 108
REQUIRED\
/
LOW: 102
SOURCE OF INFORMATION: PEGGY
A�
15 6 2 4
2. EXTEND ALL SLEEVES 12" BEYOND
SUPPLIER: WEST SAN BERNANDINO
COUNTY WATER DISTRICT
PHONE NUMBER: (909) 875-1804
EDGE OF HARDSCAPING AT BOTH
& CONTROLLER LETTER ON LID
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
VALVE STATION/GPM: STATION:
1-3
PROVIDE 6" MIN. OF SAND
GPM: 44
ITEM:
3. ROUTE SLEEVING AROUND HANDICAP
BEDDING AND SHADDING
P.S.I. LOSS:
WATER METER SIZE:
2" @
44
GPM 1.50
PRESSURE REGULATOR:
2" @
44
GPM
BACKFLOW DEVICE:
2" @
44
GPM
FLOW SENSOR:
11/4" @
44
GPM
MASTER VALVE:
2" @
44
GPM
GATE VALVE(S):
ADJACENT TO PRESSURE
44
GPM
MAINLINE (CL. 315):
TO OTHER VALVESONSAME
44
GPM
AUTOMATIC VALVE SIZE:
r �S �LE �EV �IN
44
GPM
LATERAL LINE SIZE:
4•
0 + •
7
8
GPM
-9
1 roms W11 11M w Ms an Ems 10" 0 in wnf,
10. CONTROLICOMMON
11
GPM
11. PVC SCHEDULE
40 PIPE GYP.)
17
GPM
EG. ELL
1.76
44
GPM
IRRIGATION HEAD PRESSURE: 30.00
SYSTEM LOSSES SUBTOTAL: 56.97
FITTING LOSSES (10% OF SUBTOTAL): 5.70
(ESTIMATED) ELEVATION LOSSES/GAINS (ELEV. X.433) /,0.17
TOTAL SYSTEM LOSSES: 62.84
AVAILABLE PRESSURE (LOW): 102.00
DEFICIT OR (+) RESIDUAL PRESSURE: (+)39.16
*CONTRACTOR TO SET PRESSURE REGULAT()R TO A SYSTEM DESIGN
PRESSURE OF 78 PSI CONTRACTOR TO FIELr ADJUST REGULATOR AS
NECESSARY.
7�N PRESSURE LOSS CAI.CULATION'I'.
pSCALE: N/A
WHITE
BLUE
I
IRRIGATION CONTROLLER
RED
BLACK
PLASTIC VALVE BOX (CARSON OR
EQUAL) WITH PLASTIC INTEGRATED
LOCKING LID. PLACE AT GRADE IN
TURF AREAS AND 3" ABOVE IN
PLANT BED.
RED YELLOW
3w
3w a
PIG TAIL EXPANSION
LOOP (MIN. 24- LONG) UF
fPVC CONDUIT TO WIF
CONTROLL
PEDESTAL ER
BLUE -
WHITE w/ STII
(COMMON)
SNAP-TITE WATERPROOF
CONNECTOR OR EQUAL
PIGTAIL EXPANSION
LOOP (MIN. 24" LONG)
MASTER CONTROL
VALVE
I- DIAMETER SAME
SIZE AS FLOW
7 -DIAMETER SAME SIZE AS METER SIZE
FLOW METER SIZE
MINIMUM DISTANCE DOWNSTREAM OF
UNINTERRUPTED PIPE (5X DIAMETER
OF FLOW METER SIZE)
MINIMUM DISTANCE UPSTREAM OF
UNINTERRUPTED PIPE (10X DIAMEETER
OF FLOW METER SIZE)
NOTE: WATERPROOF -ALL WIRE CONNECTIONS,
�-FLOW METERNASTER VALVE
LEGEND: Nl-./
1, ROUND PLASTIC VALVE BOX & COVER MARKED 'IRRIGATION GATE'.
USE CHRISTY FL8 BOX & FL80 LID OR EQUAL.
2. FINISH GRADE,
3, GATE VALVE - SEE IRRIGATION LEGEND FOR MODEL#.
4. 3/4" WASHED CRUSHED AGGREGATE BASE, I CUBIC FOOT.
5. SCH, 40 PVC MALE ADAPTORS.
NOTE:
PLACE AGGREGATE PRIOR TO INSTALLATION OF VALVE BOX
GATE VALVE
'
SCALE: N.T.S. 32SCALE: N.T.S.
24"
2 0_1 4
28"
7
Cl)
0_1
g4
tt
7.
CE T
8
r;14t. 7\1
**,- FO
b 6 OTING r
4" LEGEND% 4
1D 10 �9.
1. RADIO ANTENNA - LOCATION PER CITY OR MANUFACTURER'S
RECOMMENDATIONS.
2. 24' FRONT ENTRY SATELLITE ASSEMBLY wl NEMA 3R STAINLESS 4'
STEEL RAINPROOF ENCLOSURE (UL LISTED), STRONGBOX
014
MODEL# SB-24SS/120V.
0 3. MASTER VALVE RELAY OR PUMP START RELAY, Ni%
%
13 4. RADIO REMOTE ACCESS.
z
5. 1 1/2" PVC CONDUIT FOR 120 VAC FROM METERED POWER 0
Be SUPPLY OR PER LOCAL ELECTRICAL CODES. 7/,o �wz
6. POWER SWITCHIGFI RECEPTACLE.
7 8 10
7. SATELLITE CONTROLLER,
U ULAU 8. 1 1/4" PVC CONDUIT FOR COMMUNICATION CABLE. CL
8" MIN. 9. PVC CONDUIT FOR CONTROL WIRES, SIZE AS REQUIRED.
E5
32" 10.1 " PVC CONDUIT FOR FLOW SENSOR CABLE. ..... ....
-------------
11.1 1/4" PVC CONDUIT FOR COMMUNICATION CABLE TO OTHER ..... ....
12 SATELLITES (IF APPLICABLE).
12.5/8' DIA. X 8' GROUND ROD W1#10 GROUND WIRE & CLAMP. 37'
FRONT VIEW 13. POURED CONCRETE FOOTING.
14. FILL VOIDS WITH CONCRETE,
NOTE: SEE MATERIALS UST LOCATED NEXT 15. 1"PVC CONDUIT FOR #10 GROUND WIRE,
TO CONTROLLER ON SHEET L-7, 16.1 1/4" PVC CONDUIT FOR FUTURE USE.
-SENTINEL CONTROLLER, RADIO, RADIO LINK,
POWER SUPPLY, & SENSOR INPUT BOARD NOTE: SEE MATERIALS LIST LOCATED NEXT
INSTALLED ON BACKBOARD. TO CONTROLLER ON SHEET L-7.
-CONTRACTOR TO THROW AWAY PEDESTAL
TEMPLATE AFTER USE. DO NOT LEAVE UNDER
CABINET.
IRRIGATION CONTROLLER - FRONT VIEW IRRIGATION CO
SCALE: N.T.S. SCALE: N.T.S.
TRENCHING:
FINISH GRADE TRENCHING NOTES:
S REQUIRE 1. BELOW PAVED AREAS A MINIMUM
6'41 OF 6' LAYER OF CLEAN EARTH 570 SERIES PCD SCREEN SELECTION CHAR
SHALL BE INSTALLED ABOVE AND
BELOW PIPING.
2. PROVIDE MINIMUM COVER OF 24"
NON -PRESSURE ON PRESSURE SUPPLY LINES 3"
LATERAL LINE AND LARGER.
3, WHEN USING RECLAIMED WATER,
CLEAN BACKFILL -,,PRESSURE SUPPLY LINE MAINTAIN MINIMUM 10' HORIZONTAL
90% COMPACTION SEPARATION BETWEENPOTABLE
AND RECLAIMED PRESSURE LINES.
MIN. 2" OF CLEAN EARTH WHERE LINES CROSS, PROVIDE PVC
CONTROL WIRES SLEEVE FOR POTABLE LINE MINIMUM
VEACH SIDE OF RECLAIMED
WATER LINE,
4. BUNDLE WIRES WITH TAPE EVERY 10'.
SLEEVING:
LEGEND:
DRAWN BY:
KPF
CLEAN BACKFILL - SEE SPECS
ul
SCALE: N.T.S.
SLEEVING NOTES:
FOR MATERIAL 90% COMPACTION
HARDSCAPING (SEE NOTE #4)
VALVE,
REQUIRED\
/
1. ALL SLEEVES TO BE SCH, 40 PVC,
A%
A�
15 6 2 4
2. EXTEND ALL SLEEVES 12" BEYOND
Xl
z
EDGE OF HARDSCAPING AT BOTH
& CONTROLLER LETTER ON LID
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
IN 2" HIGH CF
ENDS.
PROVIDE 6" MIN. OF SAND
0j,
3. 2" CLEAR SP
3. ROUTE SLEEVING AROUND HANDICAP
BEDDING AND SHADDING
6 ryp. 6- r
37
RAMPS.
:-
ITEM:
ITEM:
NON -PRESSURE LATERAL.---
5. PVC MALE A[
4. PIPING UNDER PAVEMENT SUSCEPTIBLE
LINE SLEEVE - SIZE TWICE
6
TO TRAFFIC LOADS REFER TO CITY
DIAMETER OF NON-
1.10
STD. (24" MIN. TO 36- MAX. DEPTH TO
PRESSURE LATERAL LINE
TO SPECIFIE1
TOP OF PIPE BELOW STRUCTURAL
PRESSURE SUPPLY LINE SLEEVE
CONTROL WIRE SLEEVE -
SIZE PER PLAN, INSTALL
SECTION).
SIZE TWICE DIAMETER OF
ADJACENT TO PRESSURE
3-K (4 REQUIRED).
PRESSURE SUPPLY LINE
SUPPLY LINE.
TO OTHER VALVESONSAME
FLOW SENSOR: 11/411 @
r�R E�N C�H
I
r �S �LE �EV �IN
�G �IN
MASTER VALVE: 211 @
SCALE: N.T.S.
SCALE:
LEGEND:
1. RADIO ANTENNA - LOCATION PER CITY OR
MANUFACTURER'S RECOMMENDATIONS.
2. 24" FRONT ENTRY SATELLITE ASSEMBLY w/ NEMA 3R STAINLESS
STEEL RAINPROOF ENCLOSURE (UL LISTED), STRONGBOX
MODEL # SB-24SS/120V.
3, CONTROLLERISATELLITE PER FRONT VIEW
CONTROLLER DETAIL.
4. METER SOCKET W17EST BLOCKS.
5, CLUSTER CONTROL UNIT OR SECOND
CONTROLLER/SATELLITE IF APPLICABLE.
6, LOAD CENTER
7. POURED CONCRETE BASE.
8. #10 GROUND WIRE AND SLEEVE TO GROUND ROD CLAMP,
9. CONDUIT(S) PER FRONT VIEW CONTROLLER
DETAIL,
10.5/8" DIA. X 10' DRIVEN GROUND ROD PER
ARTICLE 250-81 OF 1990 NEC.
11. METER WINDOW WITH METER BEHIND TO FACE STREET,
3/4" ABOVE FINISH GRADE IN LAWN, WHEN
LEGEND:
DRAWN BY:
KPF
NECESSARY, AND 3" ABOVE FINISH GRADE
ul
SCALE: N.T.S.
DESIGNED BY:
KPF
IN PLANTING AREAS.
1. ELECTRIC CONTROL
VALVE,
I
494M
BY: MPH
2. RECTANGULAR
VALVE BOX WGREEN
STAINLESS STEEL HOSE CLAMP. REQUIRED.
15 6 2 4
BOLT -DOWN
COVER. HEAT BRAND VALVE
STATION NO.
& CONTROLLER LETTER ON LID
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
IN 2" HIGH CF
ARACTERS.
PHONE NUMBER: (909) 875-1804
3. QUICK COUPLING VALVE, TOP OF VALVE SHALL
3. 2" CLEAR SP
CE.
VALVE STATION/GPM: STATION:GPM:
VALVE STATION/GPM: STATION: H-19
37
4. FINISH GRAD
:-
ITEM:
ITEM:
-IF _j z
5. PVC MALE A[
APTER (TYP.)
Q G 5
6
6. PVC PIPE TO
3PRINKLERS - ANGLE PIPE
1.10
11111500111P1111 ms"111111�111 MOICIMIFIM"Nowil
11154MMISOM. 10111115M.
TO SPECIFIE1
I DEPTH WITH 45 DEG. ELLS.
GPM
4.00
11154MIRION
GPM
7. COMMON BR
3-K (4 REQUIRED).
0 0
8, COMMON WIRE
TO OTHER VALVESONSAME
FLOW SENSOR: 11/411 @
37
0
CONTROLLER.
1150MMUMM 11=21156MV1111156mv.11 "In
MASTER VALVE: 211 @
37
4•
0 + •
7
9. 3/4'CRUSHED
ROCK, 8' DEEP.
-9
1 roms W11 11M w Ms an Ems 10" 0 in wnf,
10. CONTROLICOMMON
WIRES FROM CONTROLLER.
GPM
11. PVC SCHEDULE
40 PIPE GYP.)
14 10 69 8
12. PVC SXS 90 C
EG. ELL
1.76
13. WIRE CONNE4TOR.
AUTOMATIC VALVE SIZE: 2" @
37
14.MAINLINE F
ING W/SOLVENT-WELD OUTLET.
oreM-e M.11115111111111151 M-11111111131115STM
15. COIL WIRES FIER
SPECIFICATIONS AND WITH 24" LOOP,
NOTE:
USE TEFLON TAPE ON ALL PVC TO PVC OR METAL TO PVC MALE PIPE THREADS,
16, CHRISTY'S 1, 11.
TAG WNALVE STATION NO. &
INSTALL IN SHRUB PLANTING AREAS.
1 1
CONTROLLER�
LETTER
.10
17, UNION
11/211 10 L.F @
SCALE: N.T.S.
NOTE:
BLOCKS SHOULD BE FOR MAINLINE 21/2" AND
LARGER. DO NOT USE SLIP AND BELL PVC
PIPING, THRUST BLOCKS SHALL INCLUDE #3
REBAR AROUND PIPE AND INTO THRUST BLOCK.
NTROLLER - SIDE VIEW FHRUST BLOCK
SCALE T.S.
DRAWN BY:
KPF
2
ul
SCALE: N.T.S.
DESIGNED BY:
KPF
LEGEND:
CHECKED BY:
JRC
L_
Moo,
I
494M
BY: MPH
LO z
to
U'L
STATIC PRESSURE HIGH: 108
STAINLESS STEEL HOSE CLAMP. REQUIRED.
LOW: 102
r i-- OF INFORMATION: PEGGY
2. 1/2" 3
NTROLLER - SIDE VIEW FHRUST BLOCK
SCALE T.S.
DRAWN BY:
KPF
2
ul
SCALE: N.T.S.
DESIGNED BY:
KPF
LEGEND:
CHECKED BY:
JRC
L_
PROJECT: SYCAMORE HILLS
Ill 1211 1. 10" PLASTIC VALVE BOX WITH 2" LETTERS *Q,C."
-I AND BOLT LOCK LID,
f y
BY: MPH
LO z
to
U'L
STATIC PRESSURE HIGH: 108
STAINLESS STEEL HOSE CLAMP. REQUIRED.
LOW: 102
r i-- OF INFORMATION: PEGGY
2. 1/2" 3
LIERWEST SAN BERNANDINO COUNTY WATER DISTRICT
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
PMPENSATING DEVICE
PHONE NUMBER: (909) 875-1804
PHONE NUMBER: (909) 875-1804
3. QUICK COUPLING VALVE, TOP OF VALVE SHALL
-=111=1
VALVE STATION/GPM: STATION:GPM:
VALVE STATION/GPM: STATION: H-19
37
GPM: 46
1101MEMMINUMMIMM
ITEM:
ITEM:
-IF _j z
P.S.I. LQSS:
I nonIIIIP111rem. OPINE= mrsm. "Em
WATER METER SIZE: 2" @
WATER METER SIZE: 2" @
37
GPM
1.10
11111500111P1111 ms"111111�111 MOICIMIFIM"Nowil
11154MMISOM. 10111115M.
PRESSURE REGULATOR: 211 @
37
GPM
4.00
11154MIRION
GPM
BACKFLOW DEVICE: 2" @
37
GPM
11.75
GPM
FLOW SENSOR: 11/411 @
37
GPM
1.83
1150MMUMM 11=21156MV1111156mv.11 "In
MASTER VALVE: 211 @
37
GPM
.37
I M" I F= re M. 0 =_ 101.9 Mro M M KIT
-9
1 roms W11 11M w Ms an Ems 10" 0 in wnf,
GATE VALVE(S): 1 3" @
37
GPM
2.00
1154mo I
ii MAINLINE (CL. 315): 3,, 1,058 L.F. @
37
GPM
1.76
orsm. ffq
AUTOMATIC VALVE SIZE: 2" @
37
GPM
.37
oreM-e M.11115111111111151 M-11111111131115STM
I r# M.- � F MI. r, -me M F =_ 11IM1 961 M.,
LATERAL LINE SIZE: 3/411 60 L.F. @
5
GPM
.72
NOTM11111156199"K
ill 9 L.F. @
9
GPM
.10
IrIMM4111 MIS
11/211 10 L.F @
27
GPM
.14
NrImIffrelfff"W4119MIK MIKIMMIN011i
111110 M11511111110- "9011311111
211.03
30.00
orsvZ11111WEIrevaIIIIINIFIRrevaKm "41.1rem.
1 M07011MIC M Me
IRRIGATION HEAD PRESSURE:
60.74
9. #4 REBAR STAKE 36" LONG.
30.00
Im M-IM119 MEMO
1111".31KI51115M.
6.07
SYSTEM LOSSES SUBTOTAL:
ELEVATION LOSSES/GAINS (ELEV. X.433)
54.17
-0.21
FITTING LOSSES (10% OF SUBTOTAL):
10. BRASS 90 DEGREE STREET ELL.
5.42
orwroKmawn. K mmm- swomm. sonsm!
ELEVATION LOSSES/GAINS (ELEV. X.433)
Uj
# 0 =
2.90
11. BRASS 90 DEGREE ELL.
TOTAL SYSTEM LOSSES:
W CL
11 10
62.49
AVAILABLE PRESSURE (LOW):
TO A SYSTEM DESIGN
102.00
PRESSURE OF 82 PSI CONTRACTOR TO FIELD ADJUST REGULATOR AS
3mwaEOF-5 M-. HM
DEFICIT OR (+) RESIDUAL PRESSURE:
NECESSARY.
(+)39.51
=11SM MKIMM
1 M63SM9 MOMMISM3 =I MUM
*CONTRACTOR TO SET PRESSURE REGULATOR
TO A SYSTEM DESIGN
orsm. murem.
PRESSURE OF 78 PSI CONTRACTOR TO FIELD ADJUST REGULATOR AS
NO= MIRT13mror. 03mror-1111M
NECESSARY.
PCD SCREEN CHARTU _3
I :' Nk"I Ij
SCALE: N.T.S.
SCALE:
SCALE: N/A
1. HI -POP SHRUB HEAD BODY SET 11/2' MINIMUM
ABOVE FINISH GRADE.
2. FINISH GRADE.
3. SCH. 40 PVC 90 DEGREE STREET ELL.
4. MARLEX 90 DEGREE STREET ELL.
5. SCH. 80 PVC NIPPLE TYPICAL (2) PLACES. LANDSCAPE
6. MARLEX 90 DEGREE STREET ELL. ARCHITECTURE
7. NON -PRESSURE LATERAL FITTING. SITE PLANNING
8. NON -PRESSURE LATERAL LINE.
10221 -A Trademark Street
Rancho Cucamonga, CA 91730
Tel (909) 464-2800
Fax (909) 484-2802
1 .. I., Richard Krumwiede
12" POP-UP SPRAY HEAD
SCALE: N.T.S.
U4LIU. ffdtJ
34
AZ Lic. # 29115
W Lic. # 446
' TX Lic. #1864
04 09
1101,sC
APF
ftmw/o 4
44
-4
ignatur
C�wevlf Llate
S IL , V,
Date
0
(',j, IllIl,, QUICK COUPLING VALVE
SCALE T.S.
DRAWN BY:
KPF
2
SCALE:
AS SHOWN
DESIGNED BY:
KPF
LEGEND:
CHECKED BY:
JRC
L_
r ICY)
o) CO
Ill 1211 1. 10" PLASTIC VALVE BOX WITH 2" LETTERS *Q,C."
-I AND BOLT LOCK LID,
f y
LO z
to
U'L
STAINLESS STEEL HOSE CLAMP. REQUIRED.
SOURCE OF INFORMATION: PEGGY
2. 1/2" 3
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
PHONE NUMBER: (909) 875-1804
3. QUICK COUPLING VALVE, TOP OF VALVE SHALL
< o
F- 0)
-111111-111111
VALVE STATION/GPM: STATION: H-19
GPM: 46
111011111,
ITEM:
-IF _j z
P.S.I. LOSS:
WATER METER SIZE: 2" @
46
GPM
BE 2" BELOW VALVE BOX COVER,
tu
0
46
GPM
5.00
BACKFLOW DEVICE: 2" @
46
GPM
X
12
FLOW SENSOR: 11/4" @
46
GPM
4
4. BRASS NIPPLE, LENGTH AS REQUIRED.
MASTER VALVE: 2" @
6
EOLL
GPM
.70
GATE VALVE(S): 1 3" @
z
5, PRESSURE SUPPLY LINE.
2.00
tL CY)
Q co
MAINLINE (CL. 315): 3" 1276 L.F. @
46
GPM
2.55
AUTOMATIC VALVE SIZE: 2" @
46
00
.70
LATERAL LINE SIZE: 3/411 79 L.F. @
8
6 CoUj
6. PRESSURE LINE FITTING.
LuC.VFW-00
n t
15
0
•.0
.89
o
. . 0
11/4" 9 L.F. @
7. BRASS 90 DEGREE STREET ELL,
GPM
r,
C0
CL m
0%
0
04 4•.0, INIEN
211 4 L.F. @
0
. 4 . % 0
.0
8. BRASS NIPPLE, LENGTH AS REQUIRED.
.05
Lu (n CY)
0
cc
•
30.00
SYSTEM LOSSES SUBTOTAL:
60.74
9. #4 REBAR STAKE 36" LONG.
FITTING LOSSES (10% OF SUBTOTAL):
0
6.07
ELEVATION LOSSES/GAINS (ELEV. X.433)
0 w
z z
-0.21
10. BRASS 90 DEGREE STREET ELL.
0 0
66.60
Uj
# 0 =
11. BRASS 90 DEGREE ELL.
W CL
11 10
s a 7 6 12. PEA GRAVEL, 2 CUBIC FEET MIN.
CY)
LO
TO A SYSTEM DESIGN
PRESSURE OF 82 PSI CONTRACTOR TO FIELD ADJUST REGULATOR AS
v
NOTE:
NECESSARY.
PLACE PEA GRAVEL PRIOR TO INSTALLATION
PR ES SU �REL OS SCALCULATION ��H
OF VALVE BOX.
(',j, IllIl,, QUICK COUPLING VALVE
SCALE: N/A
V7 CITY OF FOrJTArdA, CALIFORMIA
SCALE T.S.
DRAWN BY:
KPF
SYCAMORE HILLS,,
TRACT. # 495/f�
COMMU IfY FA�CL. TIES DI
SCALE:
AS SHOWN
DESIGNED BY:
KPF
PROJECT: SYCAMORE HILLS
CHECKED BY:
JRC
L_
BY: MPH
STATIC PRESSURE HIGH: 108
LOW: 102
SOURCE OF INFORMATION: PEGGY
SUPPLIER: WEST SAN BERNANDINO COUNTY WATER DISTRICT
PHONE NUMBER: (909) 875-1804
VALVE STATION/GPM: STATION: H-19
GPM: 46
ITEM:
P.S.I. LOSS:
WATER METER SIZE: 2" @
46
GPM
1.60
PRESSURE REGULATOR: 2" @
46
GPM
5.00
BACKFLOW DEVICE: 2" @
46
GPM
12.00
FLOW SENSOR: 11/4" @
46
GPM
2.82
MASTER VALVE: 2" @
46
GPM
.70
GATE VALVE(S): 1 3" @
46
GPM
2.00
MAINLINE (CL. 315): 3" 1276 L.F. @
46
GPM
2.55
AUTOMATIC VALVE SIZE: 2" @
46
GPM
.70
LATERAL LINE SIZE: 3/411 79 L.F. @
8
GPM
2.25
ill 32 L.F. @
15
GPM
.89
11/4" 9 L.F. @
23
GPM
.18
211 4 L.F. @
46
GPM
.05
IRRIGATION HEAD PRESSURE:
30.00
SYSTEM LOSSES SUBTOTAL:
60.74
FITTING LOSSES (10% OF SUBTOTAL):
6.07
ELEVATION LOSSES/GAINS (ELEV. X.433)
-0.21
TOTAL SYSTEM LOSSES:
66.60
AVAILABLE PRESSURE (LOW):
102.00
(-) DEFICIT OR (+) RESIDUAL PRESSURE:
(+)35.40
*CONTRACTOR TO SET PRESSURE REGULATOR
TO A SYSTEM DESIGN
PRESSURE OF 82 PSI CONTRACTOR TO FIELD ADJUST REGULATOR AS
NECESSARY.
t
PR ES SU �REL OS SCALCULATION ��H
SCALE: N/A
V7 CITY OF FOrJTArdA, CALIFORMIA
DRAWN BY:
KPF
SYCAMORE HILLS,,
TRACT. # 495/f�
COMMU IfY FA�CL. TIES DI
SCALE:
AS SHOWN
DESIGNED BY:
KPF
7/x/04
CHECKED BY:
JRC
L_
APPROVED BY:
-AE)T+NG CITY ENGINEER R.C.E. 51152 EXP. DATE 12/31/05