HomeMy WebLinkAbout3639-1GENERAL NOTES
1, ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND
THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'. ALL REFERENCE SPECIFICATIONS AND STANDARDS
SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE
PRECEDENCE PROVISIONS IN THE 'GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER
FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER,
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING
DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO
THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS, CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF
CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES
AT All TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN
DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS CP.FATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF
THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF
CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT
PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE
PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE,
ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD
CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION,
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK
TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION
CONTROL STAKING DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION
TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS,
SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS
A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE
MAINTAINED AT ALL 11MES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
18, THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT
ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE
PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE
RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION
OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS,
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE
BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL
CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA
STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700.
26, NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS
IN ALIGNMENT.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS.
CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE
PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC
UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED
FROM THE UTILITY EASEMENT.
31, THE SEWER CONTRACTOR SHALL STAMP AN 'S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL.
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE
ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR
UPON COMPLETION OF PAVING.
37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL
DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS
TO THE CITY ENGINEER.
PREPAFM BY
FIRM: raab "sneering, im.
ADDRESS: 310 S, MAPLE ST., STE. D
CORONA, CA 92880
TELEPHONE: (96y) 27 72 FAX: ( 951) 272-0166
1 "a - ,I V'_ 29616
SIGNATURE RCE ATE
p�OFESSrpN
r� N0. 29616 r,
Of A
4L Exp. 3/31/07 4
VI
OF- CAL�F�
CITY OF FONTANA
SEWER IMPROVEMENT PLANS
FOR TRACT NO. 16597
LEGEND
BC
SEWER LINE
EC
END CURVE
SEWER LINE PER
CENTERLINE
OTHER SHEET
- --EX 5- -
EXIST. SEWER LINE
FINISHED SURFACE
STORM DRAIN LINE
FINISHED DIRT
EX
WATER ONE
--R W
EXIST. WATER LINE
0
SEWER MANHOLE
W
DIRECTION OF FLOW
ST
- -
RIGHT OF WAY
1_
EDGE OF PAVEMENT
MANHOLE
CENTERLINE
a�
WATER VALVE
f
FIRE HYDRANT
Q--
STREET LIGHT
®
HANDICAPPED ACCESS RAMP
BC
BEGIN CURVE
EC
END CURVE
CL
CENTERLINE
F.L.
FLOWLINE GUTTER
F.S.
FINISHED SURFACE
F.
FINISHED DIRT
EX
EXISTING
S
SEWERUNE
SD
STORM DRAIN LINE
W
WATERLINE
ST
STREET STATION
10+00.00
SEWER STATION
MH
MANHOLE
INT.
INTERSECTION
R/W RIGHT OF WAY
CONSTRUCTION NOTES
�1 CONSTRUCT 4' DIA. SEWER MANHOLE PER CITY OF FONTANA STD. NO. 109, 112, & 114
to CONSTRUCT 5' DIA. SEWER MANHOLE PER CITY OF FONTANA STD. NO. 109, 112, & 114
20 CONSTRUCT 4' DIA. (EXTRA STRENGTH) V.C.P. LATERAL WITH CLEAN-OUT AND
PLUG PER CITY OF FONTANA STD. NO. 125
REMODEL EXISTING SEWER MANHOLE
® CONSTRUCT 8' EXTRA STRENGTH V.C.P. SEWER MAIN
4A CONSTRUCT 8" D.I.P. SEWER MAIN
0 INSTALL SEWER BACKFLOW DEVICE
®Q CONST, SEWER MAIN SI1=EL ENCASEMENT PER DETAIL SHEET 1
NORTH
100 0 100
SCALE 1" = 100'
INDEX MAP
XDENOTES SEE SHEET NO.
OUANTITIES
6 EA.
1 EA.
1285 L.F.
2 EA.
727 LF.
962 LF.
11 EA.
55 LF
El 01
3' MAX. SIZE NATIVE
SOIL COMPACTED 95%
G' MIN. _
10' MAX.
6" MAX. SIZE
NATIVE SOIL -
COMPACTED 90%
1/2' CRUSHED STONE BEDDING
PER STD, SPECS FOR PUBLIC
WORKS CONSTRUCTION TABLE
200 1.2 [A] SHOWN
8' VCP/DIP
MIN.
10" MAX.
18'X3/8' WELDED
STEEL CASING
-L At V"V 1"#JrtUI RCUAVW aNUJ J LtAW
BEVELED BOTH ENDS (4) SKIDS PER
LENGTH OF PIPE TO BE STRAPPED
IN PLACE S FROM EACH END OF
PIPE. NOTCH SKID TO SEAT STRAP.
ORAL NOTES
1. ALL STEEL CASING PIPE FIELD JOINTS SHALL
BE WELDED FULL CIRCUMFERENCE.
2. REDWOOD SKIDS SHALL BE PROVIDED PER
DETAIL ABOVE.
3. CARRIER PIPE SHALL BE PRESSURE TESTED
PRIOR TO FILLING CASING WITH SAND.
4. CASING TO BE FILLED WITH AIR BLOWN SAND.
5. EACH END OF CASING SHALL BE SEALED WITH
CONCRETE.
6. CONTRACTOR SHALL FURNISH ALL NECESSARY
THRUST RESTRAINT DEVICES.
A\
STEEL CASING PIPE DET
N.T.S.
1' MAX. SIZE
SELECTED NATIVE
BEDDING COMPACTED
TO 90% -
TYPICAL BEDDING FOR 8" VCP/ DIP
* QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY AND ARE PROVIDED TO ASSIST THE CITY IN 1O' OR DEEPER
DETERMINING FEE & BOND AMOUNT ONLY NOT TO SCALE
* * THE CONTRACTOR SHALL VERIFY ALL QUANTITIES PRIOR TO START OF CONSTRUCTION.
O
o
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YDU DIG
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE
ENGR.
CITY
DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CON WITH CONDI110NS' AND
STANDARDS IN EFFECT.
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5467
SOUTHERN CALIFORNIA GAS COMPANY
UNDERGROUND SERVICE ALERT
ATTN: DENNIS FREEMAN
(800) 422-4133
1981 W. LUGONIA AVE.
0-5
REDLANDS, CA. 92374
COMCAST (CABLE TV)
(909) 335-7547
ATTN. JACK HAYES
EMERGENCIES: (800) 427-2200
1205 DUPONT AVE.
3
zftotp
SOUTHERN CALIFORNIA EDISON COMPANY
(909) 390-4738
300 N. PEPPER STREET
REV, SEWER CONNECTION AT BEECH AND MODM MAIN ALJGN
ALONG BASELINE AVE SHT. Z, ADDED ENCASEMENT DET. SHIT
T
306106
(9 09 820-5598 -- UNDERGROUND
ATTN: STEVE HOCK
1
0
ADDED LINE IN BASELINE AVE. BETWEEN AVOCADO AND BANYAN
CT, ELIMINATED ONE IN BASELINE W/O AVOCADO; CORRECTED
STREET NAMES, LOWERED AVOCADO CT CURBS AND PADS
1
1/09/06
ONTARIO, CA. 91766
3" MAX. SIZE NATIVE
SOIL COMPACTED 95%
6' MIN.
10' MAX. - -
- E
N
6" MAX. SIZE -
NATIVE SOIL
COMPACTED 90%
8' VCP/DIP
UTILITY NOTIFICATIONS
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: BRIAN WREN
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5467
SOUTHERN CALIFORNIA GAS COMPANY
UNDERGROUND SERVICE ALERT
ATTN: DENNIS FREEMAN
(800) 422-4133
1981 W. LUGONIA AVE.
0-5
REDLANDS, CA. 92374
COMCAST (CABLE TV)
(909) 335-7547
ATTN. JACK HAYES
EMERGENCIES: (800) 427-2200
1205 DUPONT AVE.
ONTARIO, CA 91761
SOUTHERN CALIFORNIA EDISON COMPANY
(909) 390-4738
300 N. PEPPER STREET
RIALTO, CA 92376
GENERAL TELEPHONE CO.
(9 09 820-5598 -- UNDERGROUND
ATTN: STEVE HOCK
(909 875-5100 -- TRANSMISSION
1400 E. PHILLIPS BLVD.
(213 637-1233 -- PIPELINES
ONTARIO, CA. 91766
(800) 422-4133
CRAWFORD CANYON MUTUAL WATER CO.
FONTANA WATER COMPANY
ATTN: BILL VANDERKIEFT, JR.
(619) 868-6040
ATTN: MICHAEL J. MCGRAW
8440 NUEVO AVE.
FONTANA, CA. 92235
(909) 822-2201
FAX (909) 823-5046
PRIVATE ENGINEER'S NOTES TO
CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR ANY STRUCTURES SHOWN ON THESE
PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES
TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND
RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR AGREES THAT HE/ SHE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CITY, THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR
LMLiTY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
BASIS OF BEARINGS
THE BEARING OF N 89'58'10' W FOR THE CENTERLINE OF FOXWORTH STREET, AS SHOWN ON A MAP OF TRACT NO. 14293,
RECORDED IN BOOK 255, PAGES 94-98, INCLUSIVE, OF MAPS, RECORDS OF SAN BERNARDINO COUNTY, CALIFORNIA, WAS
USED AS THE BASIS OF BEARINGS FOR THIS MAP.
BENCHMARK
CITY OF FONTANA BENCHMARK NO. 378, CIRCUIT NO. 67-5, 30D NAIL IN POWER POLE (NO NUMBER), SOUTHWEST CORNER
OF BEECH AND FOOTHILL BLVD., DATED SEPTEMBER 1967.
ELEVATION = 1267.84'
0 RECORD DRAWING 10 *_ Lss�q� F�
e
110. 29616 r„
L+ A
r
0 21 ICA
Exp. 3/31 /11 4
MARK L. RAAB RCE 29616 DATE
OF CAO
1' MAX. SIZE
SELECTED NATIVE
BEDDING COMPACTED
TO 90%
TYPICAL BEDDING FOR 8" VCP/DIP
LESS THAN 10' DEEP
NOT TO SCALE
MLR
DESIGNED BY:
MLR
CHECKED BY:
MLR
TABLE = 200 -12 [A]
SIEVE SIZE
PERCENTAGE PASSING SIEVES
1-1/2'
-
1'
-
3 4'
100
1/2'
90 - 100
3118,
20 - 60
NO.4
0-15
NO.8
0-5
ASTM C 131 TEST GRADING
B
no13rM
�
BASELINE
AVE
/`' PROJECT
SITE
FOOTHILL
AVE
VICINITY MAP
NOT TO SCALE
CITY OF FONTANA, CALIFORNIA
SEWER PLAN - TRACT 16597
Tr�_E SHEET
;V
TY ENGINEER R.'C.E. 511527. �WrK
SCALE:
DATE:
MAR. 20, 2006
DRAWING P40.: 1
3639 4