Loading...
HomeMy WebLinkAbout3628-7DHE 0 �I I I _ CITY O F 11 1 POINT OF CONNECTION1 RANCHOAT STATION 12+13, z NEW CONTROL WIRES CFROM CSTUB-OUTS MAINLINE OF EXISTING D '°` - A-28 I CITY 0� FON TAN A A-26 C U C A M O N G A a~ 140E 37G 140E 37G LJ U I 1 NEW CONTROL WIRESIRRIGATION SYSTEM; THROUGH EXISTINGNSTALL NEW SLEEVE140E 37G TO SERVICE NEW MEDIAN IRRIGATION SYSTEM. „ Q I 50mm 2" 50mm 2 50mm 2 II � Icy ci I (1) weseew -w .em www �w .aR wase Meese apse aww ow w- ,www mm "m on" wm- mm a®ee "m "m mm mm W" m" w�„ w�+ea�r�rr� .mowasoma �nm am¢ N� "m mm +tea w � mm wage w. "m 4ww" "m a w.ewe .wee waw r sew mea sear ern e e �w era wee o m esu e�.�e m ae�a e� w�ea .mer es�e� aa� e+� wee w� ems+ ..._..._ I 9 SPRINKLER HEAD LEGEND r . "10+00 rrr ,/o r• -'r SYMBOL DESCRIPTION 18G MNFTR. MODEL ARC P.S.I. BAR G.P.M. L.P.M. RADIUS REVIEWS ARE TO BE CONDUCTED WITHOUT THESE DRAWINGS. SHRUB POP-UP SPRAY TORO 57OZ-12P-COM 90 Q 30 2 .10 .36 5 FT. 1.53 M 8. AREAS RECEIVING AN IRRIGATION SYSTEM SHALL BE REVIEWED AND VERIFIED SHRUB POP-UP SPRAY TORO 57OZ-12P-COM 180 H 30 2 .20 .72 5 FT. 1.53 M 7 SHRUB POP-UP SPRAY TORO 570Z -12P -COM 180 H 30 2 .50 1.89 8 FT. 2.44 M 8 SHRUB POP-UP SPRAY TORO 570Z -12P -COM 90 Q 30 2 .40 1.51 10 FT. 3.05 M V SHRUB POP-UP SPRAY TORO 570Z -12P -COM 180 H 30 2 .71 2.68 10 FT. 3.05 M ® SHRUB POP-UP SPRAY TORO 57OZ-12P-COM 90 Q 30 2 .50 1.89 12 FT. 3.66 M m SHRUB POP-UP SPRAY TORO 57OZ-12P-COM 180 H 30 2 1.09 4.12 12 FT. 3.66 M CONTRACTOR SHALL CONNECT TO EXISTING STUB -OUTS FOR WATER AND CONTROL SHRUB POP-UP SPRAY TORO 570Z -12P -COM 90 Q 30 2 .85 3.25 15 FT. 4.57 M ® SHRUB POP-UP SPRAY TORO 570Z -12P -COM 180 H 30 2 1.65 6.24 15 FT. 4.57 M Underground Service Alert Call: TOLL FREE 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG i CITY OF FON TAN A A-29 69L 18G 50mm 2" A-30 132L 35G 50mm 2" 1'VViri1LL 1SVU11LVHI[LJ POINT OF CONNECTION -12 - AT STATION 15+47, CONNECT NEW MAINLINE PIPE AND NEW CONTROL WIRES FROM STUB -OUTS OF EXISTING IRRIrATI()N gYSTFM- INIRTAI I NFW MAIN[ INF ANn IRRIGATION NOTES: A-31 132L 35G 50mm 2" ,-0.254m S WITH CASING Q z a z n 7. AS -BUILT DRAWINGS AND SPECIFICATIONS SHALL BE MAINTAINED ON SITE AT ALL 0 0: TIMES. AS -BUILT DRAWINGS SHALL BE UPDATED ON DAILY BASIS. NO SITE REVIEWS ARE TO BE CONDUCTED WITHOUT THESE DRAWINGS. 1. INSTALL ALL PRESSURE AND NON -PRESSURE LINES AND ANY EQUIPMENT INSIDE PLANTING AREAS WHEREVER POSSIBLE. (ITEMS SHOWN OUTSIDE SUCH AREAS 8. AREAS RECEIVING AN IRRIGATION SYSTEM SHALL BE REVIEWED AND VERIFIED GENERAL IRRIGATION LEGEND FOR PURPOSES OF CLARITY ONLY.) BY THE INSTALLING CONTRACTOR FOR ACCURACY OF SIZE AND CONFIGURATION. 0 50mm (OR 2") WATER METERS POINT OF CONNECTION; VERIFY EXACT LOCATIONS IN FIELD. 2. ALL EQUIPMENT SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH IF DISCREPANCIESARE FOUND THAT WOULD PROVE DETRIMENTAL TO FINAL COVERAGE, THIS SHALL BE BROUGHT TO THE OWNER'S ATTENTION BEFORE MV SUPERIOR MASTER VALVE; 950 DW SERIES BRASS; SIZE AS NOTED ON PLAN. INSTALL HATH 50mm (OR 2") FLOW SENSOR; DATA INDUSTRIAL IR SERIES, BRASS. ® TORO NETWORK 8000 32 -STATION CONTROLLER "E". SPECIFICATIONS AND CONSTRUCTION DETAILS. SEE SHEET NO. LD -2. INSTALLATION. BY FAILING TO DO SO, THE CONTRACTOR MAY BE RESPONSIBLE 0 SUPERIOR REMOTE CONTROL VALVE; 950 DW SERIES BRASS; SIZE AS NOTED ON PLAN. VERIFY EXACT LOCATION WITH AGENCY S REPRESENTATIVE. CONTROLLER TO BE INSIDE STEEL ENCLOSURE BY V.I.T. STRONG BOX. 3. WHERE PRESSURE REGULATING VALVES ARE USED, VALVES ARE TO BE ADJUSTED FOR ANY ADJUSTMENTS REQUIRED. H NIBCO T-136 SERIES GATE VALVE. LINE SIZE. FOR OPTIMUM PRESSURE, OR AS NOTED ON DRAWING. g CONTRACTOR SHALL BE RESPONSIBLE FOR WATER AND ELECTRICAL Q CAMPBELL SCIENTIFIC INC. TE525 TIPPING BUCKET - HEAVY DUTY MODEL. TATION 11 4, ADJUST ALL SYSTEMS TO AVOID SPRAY ONTO WALLS, WALKS, AND ROADWAYS CONSUMPTION UNTIL THE AUTHORIZED CITY REPRESENTATIVE ACCEPTS PROJECT. 0 RAINBIRD 33DRC 19mm (OR 3/4") QUICK -COUPLING VALVE WITH LOCKING COVER, ALLONS PER MINUTE PIPE do SLEEVE SIZING BY INDIVIDUALLY ADJUSTING SPRINKLER HEADS AND CONTROL VALVES. 10, A, B, C IRRIGATION SYSTEMS ARE BASED ON CITY STA11C WATER PRESSURE OF 80 P.S.I. Rp FEBCO 825YA 50mm (OR 2") REDUCED PRESSURE BACKFLOW PREVENTER. INSTALL PER MANUFACTURER'S SPECIFICATIONS AND PER LOCAL CODE. ALVE SIZE - IMPERIAL A - 3 4" OR 19m / E� 2" OR 50mm MUTERS 5. AREAS THAT NEED TO BE DEFINED IN ORDER TO DETERMINE EXACT LOCATION AVERAGE PRESSURE DATA WAS OBTAINED FROM THE CUCAMONGA COUNTY WATER DISTRICT (FOR AREAS WEST OF CHERRY AVENUE). FOR EAST OF CHERRY AVENUE, THE INSTALL PATH VANDAL -RESISTANT STEEL ENCLOSURE BY LEMEUR OR EQUAL. ALVE SIZE - METRIC B - 1" OR 25npn = 2-1/2" OR 63mm I OF SPRINKLER HEADS ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR FONTANA WATER COMPANY HAVE PROVIDED CITY STATIC WATER PRESSURE OF 70 P.S.I. PER MINUTE C = 1-1/4" OR 32mM - 3" OR 75mm TO SEE THEY ARE DEFINED PRIOR TO INSTALLATION. CONTRACTOR IS TO VERIFY THIS INFORMATION BEFORE INSTALLATION IF DATA VARIES LASCO SCHEDULE 40 PVC MAINLINE 1-1/2" do SMALLER; CL. 315 PVC 2" & LARGER; SIZE AS NOTED ON PLAN. D - 1-1/2" OR 38mFp - 6" OR 150mm FROM THIS INFORMATION. CONTRACTOR IS TO NOTIFY OWNER FOR INSTRUCTIONS. g, CONTRACTOR SHALL CONNECT TO EXISTING STUB -OUTS FOR WATER AND CONTROL FAILURE TO DO SO COULD RESULT IN CONTRACTOR BEING RESPONSIBLE FOR CHANGES LASCO CLASS 200 PVC LATERAL UNE. BURY MINIMUM 305mm (OR 12") BELOW FINISH GRADE. WIRES AS SHOWN ON THESE PLANS. CONTRACTOR SHALL PROVIDE ALL LABOR THAT MIGHT OCCUR. (H150mm OR 6" OTA.) EXTEND 305mm (OR 12') BEYOND CL. 315EDGE AND EQUIPMENT AS NECESSARY TO PROVIDE PROPER CONNECTIONS. OFPAVING.N- GRAPHIC SCALE IN METERS 10 0 5 pm%110111m 6" 10 20 30 40 50 1 :500m i NOTE: ALL DIMENSIONS ARE IN METERS UNLESS SHOWN OTHERWISE.