Loading...
HomeMy WebLinkAbout3617-1 TRAFFIC SIGNAL GENERAL NOTES: 1, TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE PLANS, LEGEND: THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, THE STATE OF • DOLE SCHEDU E CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATE JULY ►o= - IMAGE SENSOR UNIT. L STANDARD MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT REMARKS 2002) THE 2003 MUTCD AND THE CALIFORNIA SUPPLEMENT TO 2003 MUTCD. 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIF'Y ALL CONDITIONS ON THE JOB - UNI-DIRECTIONAL , SINGLE CHANNEL OPTICAL DETECTOR T 26A-4-80 35' 35' 15' 250W B 8 S SV-1-T SP-1-CS San Bernardino Ave 12' 10' 1 SITE. HAND DIG FOUNDATINS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE UNDERGROUND '1 SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 2J 1A 10' - - - B 2 W TV-1-T SP-1-CS - 10' 4' 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS el - ADVANCE VIDEO DETECTION ZONE. �315' Jl 26A-4-80 35' 30' 250W B 2 W SV-1-T SP-1-CS Alder Ave 12' 5.5' 1 OTHERWISE SHOWN. }4`1\ 1A 10' - - - B 4 N TV-1-T SP-1-CS - 11 4' 4. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH 5 26A-4-80 35' 35' 15' 250W B 4 N SV-1-T SP-1-CS San Bernardino Ave 10' 11' 1 SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 6 1A I�' - - - B 6 E TV-1-T SP-1-CS - 11' 4' 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE ES-4C FOR POLE LOCATION DETAIL. �. 26A-4-80 35' 30' 15' 250W B 6 E SV-1-T SP-1-CS Alder Ave 13' 5.5' 1 Q 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA QBJ 1A 10' - - - B 8 S TV-1-T SP-1-CS - 14' 6' J ENGINEERING DIVISION AND COUNTY OF SAN BERNARDINO PUBLIC WORKS DEPARTMENT ■ ALL EQUIPMENT IS NEW. 1. MODIFY SIGNAL MASTARM BUTT PLATE TO FIT CL PRIOR TO COMMENCEMENT OF WORK. STANDARD TYPE 26A POLE MOUNTING. ' ED I 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND SIDEWALK I AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. w 0 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKERS SYSTEMS IF NECESSARY. g, THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE. HOWEVER, W ¢ Q WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE MINIMUM RADIUS OF 10 ' J ( BARRIER FEET. Z 10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN ' / Q HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES. W ! PHASE DIAGRAM • 84' Ir(. 11. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED FUTURE FUTURE J WITH NEW CONSTRUCTION. Q i 8 32' f 32' 1� 12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE O I % — — " PHASE 1 PHASE 2 PHASE 3 PHASE 4 TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY FURNISHED I 0 — J OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. 0 I R26(s) 13. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR �- FUTURE FUTURE -- Q POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS FOR THIS PROJECT. 1 PHASE 5 PHASE 6 PHASE 7 PHASE 8 14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE PER DETAIL ON THIS SHEET, AND SPECIAL PROVISIONS, SECTION E. SAN BERNARDINO • AVENUE v J I 15. TRAFFIC SIGN DIMENSIONS, COLOR, AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS • 6 SIGN SPECIFICATIONS SHEETS, THE 2003 MUTCD AND THE CALIFORNIA SUPPLEMENT TO 2003 �� MUTCD. SIGN CODES SHOWN HEREON ARE TO CONFORM TO THE SAME. TRAFFIC SIGN SIZE SHALLLL LLI 1 BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. I I VI , 1 16. ALL PEDESTRIAN AND VEHICLE INDICATIONS SHALL BE INSTALLED WITH L.E.D. MODULES. t4 O #i/I/ w C ,iii = , •� ,Rda\ Q Curb/Berm flow line "A" CC or edge of shoulder I\ O R2(35) �" vs-4 A01111 N R26(S) OMNI R30(MOD) R48 �- 1144�iO — R36(5) R26(S) „8. ' n 8 ---- ,ZNI . ' 0NW- "2 �2 ' ilk* m 02' R26(S) R26(S) / LLI r _. � � �ii. • ,> 6 ,to '�C I,' ' _. - - -- — -- - 200 TO�7 I''11 _ ��LIMIT LINE �A ,,,, QIll Ili _ /40 ,� ( !; r.; N — BCR 5 1,04! rf I I11111 I 211-00 _0 0 CITYIFONTANA + I 19+00 i I 20- 00 I1 ,� 1 / COUNTY OF SAN BERNARDINO 200' TO z i ;; ; I f A 04 I coQ ® LIMIT LINE z z 5 �J _ N A e w - N INSTALL 2" C. I I o a 4 EDWITH 2#6 (SIG.) e ,o `� I Q i _ � 3 i• 08 0 T A _ U ' / h .0. _c, 1. R26ZS) R26(S) N a..5-2::=1"1-'*. i! ilii al z :W9 p I IN OMNI IC *W4 2 nr - Aim�7i � R26(S) P �, \ X — — — x- 2 :ill", 1 � 3 1 lin 2 Li I ►� i O CONDUCTOR TABLE INSTALL 2" ,iV r : , RUNS ��'��'� _ _ ITIOTRAFFIC SIGNAL CONSTRUCTION NOTES: i N■ CIRCUIT OR WITH 2#10 (LUM.) i V _ r 0 AWG. POLE A A A A A A AAAA O ' ' ' I 11 O INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, 1 , , 1 POLE 10 1/1 1/1 1/1 1/1 1/1 1/1 5 SOLO PRO VIDEO DETECTION, BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER / O 0 w CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR ►r ,I m 6 I SHALL AL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE POLE 20 1/1 1/1 1/1 1/1 1/1 SIGNAL OPERATION AS SHOWN ON THE PLAN. I MA — ST ARMQo POLE O3 1/1 1/1 1/1 1/12INSTALL TYPE III-BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN re CALIFORNIA EDISON COMPANY REQUIREMENTS (SEE SPECIAL PROVISIONS). o POLE O 1/1 1/1 1/1 W ; Q FURNISH AND INSTALL 3" PVC CONDUIT WITH 1 4 POLY PULL ROPE PER SCE REQUIREMENTS. oz X12' O 32' i 12�L 3 / POLE0 1/1 1/1 A O ! /Q COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 AND CANERA MILES `� mil I + it2&( 909-357-6505). PC J O� 88' s CC POLE 60 1/1 4 I I �` CO POLE O7 1/1 1/1 4 INSTALL CTY FURNISHED IMAGE SENSOR ON LUMINARE MAST ARM AS DIRECTED BY THE ENGINEER. MAST—ARM MOUNTING ci I CLAMP FOR OPTICAL DETECTOR o POLE 80 1/1 1/1 1/1 - 5 I FURNISH AND INSTALL UNIDIRECTIONAL OPTICAL DETECTOR PER DETAILS SHOWN ON THIS SHEET I I AND AS DIRECTED BY THE ENGINEER (SEE SPECIAL PROVISIONS.) TOTAL 1/1 2/2 3/3 4/4 5/5 5/5 3/3 2/2 1/1 v Li 6 FURNISH AND INSTALL S.N.S ON CITY FURNISHED S.N.S. MAST ARM. v 1 r7 #10 LUMINAIRE 2 2 2 2 2 - - - 2 - VIDEO VIDEO CABLE 1 1 2 2 3 - 4 - 1 R�(40) __- N .' h-� DET. - l -- � - �� .__ j `� I I OPTICOM CABLE 1 1 2 2 3 - - 4 1 - �� I 20 10 0 20 40 60 CONDUIT SIZE 2" 3" 3" 4" 4" 4" 3" 4" 3" 2" � AUTOCAD FILENAME: SonBerdo�Jder TS.dwg SERVICE ADDRESS: 17687 San Bernardino Avenue COUNTY OF SAN BERNARDINO .o, O SHOULD CONSTRUCTION OF THE REQUIRED DEPARMENT OF PUBLIC WORKS Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA IMPROVEMENTS NOT COMMENCE WITHIN TWO ����oQR�FESS/SpN' ,/� TRAFFIC SIGNAL INSTALLATION PLAN DO ,\I-LAIL YEARS OF THE DATE OF APPROVAL SHOWN HEREON APPROVED: SCALE.W DRAWN BY:DIAL � Tw❑ w❑RKING AND CARRIED FORTH IN A DILIGENT MANNER, THE No. C6'�3$J RG SAN BERNARDINO AVENUE 1 "=20' — BEFORE I► DAYDUBEFORE CITY ENGINEER MAY REQUIRE REVISIONS TO THE * EXP. 6-30-07if ,�j`" DESIGNED BY: AT DATE: YOU DIG �� RG /621"/VENUE VENUE / REV. PLANS TO BRING THEM INTO CONFORMANCE WITH CIVIL lil 6/17 04 TOLL FREE 1-800-227-2600 �' 3 I. O s UJ9j Date :�p"{/yl CHECKED BY: APPROV ! • f DRAWING NO.: A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT. CHIEF, TRAFFIC DIVISION DATE FOF CAL�E�� d ►. / DATEl2'-frr 1 NAQEfiM SVC) R.C.E.�o4.38/ HC CITY ENGINEER R.C.E. 51152 3617 3